SEIH7KTS1,SEIH9KTS1 SEIH11KTS1. Installation Manual. Issue STROM- ELECTRICAL.

Similar documents
Installation Manual SEIHTP1, SEIHTM1. Issue SEIHTM1 Model Shown STROM- LIMITED.

ELECTRIC WATER HEATER HT382E55

Operating and assembly manual: Electric instantaneous flow heater Admiral

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

Tankless Electric Water Heater MS-C2PSU Series

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

CONTENTS. Important Safety Instructions page 2

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Installation and Operation Guide

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Powerflow Unvented water heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

HW3 Handwash Installation and Operating Instructions

Automatic Infrared Tap TAPIFR. Instruction Manual

Flow Factor ~

SCHWAN INSTALLATION GUIDE

SEALED THERMAL STORE

INSTANTANEOUS ELECTRIC SHOWER

Installation and Operation Guide

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

INSTALLATION & TECHNICAL MANUAL

Eliminator TotalGuard Installation Manual

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

PolyMax H2-24 Dutch Bucket System

ADVANCE ECB ELECTRIC COMBINATION BOILER

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

OPERATING AND INSTALLATION MANUAL

TH100 Three in One Instant Hot Water Tap

INSTALLATION & TECHNICAL MANUAL

PURE 7.5/8.5/9.5/10.5kW

Installation and Operation Guide

Friwa Compact. Operating instructions EN

OPERATION & INSTALLATION MANUAL

Zen Boiling Tap Range

SUBMERSIBLE WATER PUMPS

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

PJ130S High Pressure Cleaner

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

Sanitary Water Tank INSTALLATION & SVC MANUAL

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - HW

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Instant Hot Water Dispenser Owner s Manual

OPERATING AND INSTALLATION MANUAL

Unvented Electric Water Heater 10/15 litre Undersink

Pump WaterVISE, FloVISE

APW-VAP-150P High Pressure Cleaner Operator Manual

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

ADVANCE ELECTRIC THERMAL STORE

Installation and User Instructions HS10U, HS15U.

ELECTRIC SHOWER INSTALLATION and USER INSTRUCTIONS

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

O Pro electric storage water heater

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

USER INSTRUCTION MANUAL. Autofill Water Boiler

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

ZIP VARIPOINT II Direct unvented water heaters.

Installation Instructions and User Guide. Heritage Fixed Riser Kit. Models Covered: STC03 (Chrome) STA03 (Gold)

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

HS&S Alert No: 103 Date: 9 March 2017

COPPER FREESTANDING TUB

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Mira Sport Max with Airboost

SCHWAN INSTALLATION GUIDE

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Stored Water District Heating Interface Units. Heat Interface Units

Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Dene Bath Shower Mixer

Autofill Wall Mount Boilers

Owner s Guide and Installation Manual

VERONA INSTALLATION GUIDE

Owner s Guide and Installation Manual

Installation and User Instructions

T550i power shower pump Installation and operating instructions

Water Distillation System Instruction Manual Nutriteam TC-501

TRONIC 6000C. Tankless electric whole house water heaters. Models: WH17 / WH27. [en] Installation Manual and Operating Instructions

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Hydraulic rock drill

NON-SUBMERSIBLE WATER PUMP

Owner s Guide and Installation Manual

Grant Vortex Pro Boiler House Range 26/36, 36/46, 46/58 and 58/70

Transcription:

SEIH7KTS1,SEIH9KTS1 SEIH11KTS1 Installation Manual Issue 1 2015 STROM- ELECTRICAL www.strom-electrical.com

INTRODUCTION Thank you for purchasing your Strom-Electrical instaneous water heater, we are very proud of our products and we are sure that you will be happy with the years of service you get from your model. This product has been designed to operate at mains pressure and deliver instant hot water. SPECIFICATION MODEL SEIH7KTS1 SEIH9KTS1 SEIH11KTS1 Body Material High Quality Glossy IMD Cover Voltage 220-240v Rated Frequency 50-60Hz Power 7.5kW 9.0kW 11.0kW Rated Current 32.7A 39.2A 47.9A Supplied Cable Size 6.0mm 2 6.0mm 2 10.0mm 2 Overheat Protection 67 o C Thermal Cut-Out 90 o C Control Mode Touch Screen Controls Temperature Range 30 o C - 55 o C Water Connections G1/2 Working Pressure 0.02-0.6mPa IMPORTANT NOTICE For your satisfaction and safety, read all instructions before installing or using this instant hot water heater. This appliance should be connected to a public mains water feed. This water heater may not be suitable for children or some elderly operators unattended due to the risk of scalding should the unit be incorrectly operated. Your Strom-Electrical water heater MUST be installed and maintained regularly by a qualified

professional in accordance with current electrical and plumbing regulations. If the chloride content exceeds 200ppm a filtration system should be fitted, failure to do so may invalidate your warrenty. This device has been designed for internal use only, if the system may be exposed to frost please drain down the system completely, and DO NOT attempt to use the device if you suspect it is frozen. Always ensure that the flow temperature is not excessive before use. If the water is too hot please increase the flow at the tap and wait for the temperature to reduce. As part of the product maintenance regularly clean the filter washer provided at the heater, failure to do so may reduce your flow rate over time. The heater is not designed for modification in any way, please do not fit anything to the unit unless otherwise recommended. When comissioning the water valve should be adjusted to increase or decrease the water flow to the unit, this in turn will control the temperature of water from the unit, slower increases the temperature, faster decreases the temperature. Each unit is tested at our factory before its departure, a little residual water is normal, and the product should be flushed through before use. Never try to operate this device if your water supply is blocked or turned off, doing so could cause premature failure of your device. Any damage to the wiring or integrity of your device should be assessed by a qualified electrician, and the device should not be used until the unit or wiring has been repaired. The minimum water supply available at the point of install is 0.02mPa. The unit must be installed in a vertical position with the connections facing downwards and should not be installed in an area with high magnetic interference. BEFORE INSTALLATION This installation must only be carried out by qualified professionals and installed to all relevent national and local electrical and plumbing regulations. Failure to do this could render the install both illegal and dangerous. Before installation please ensure the following: 1. Your Strom-Electrical appliance is intact, and the fittings are supplied & complete. 2. Please make sure the mains power supply, water pressure, earthing condition, and cabling reach the standards required for installation as required by all relevent regulations & laws. 3. The appliance must be properly earthed in accordance with all current regulations and laws. 4. If the unit is not to be used for a prolonged period of time please drain down and isolate the electrical supply of the product. 5. Position the unit upright with all plumbing connections at the bottom of the unit. 6. During the installation please test water flow is achieved at the tap before connecting the power supply. If the heater is activated without water supply the unit may be damaged. 7. This water heater may cause a small amount of water expansion due to residual heat after operation. In most systems this is easily accommodated by the distribution pipework and water supply system. In instances where problems may occur such as the existence of upstream non return valves close to the heater then it is recommended that a small shock arrestor/expansion vessel is fitted.

PRODUCT STRUCTURE WIRING SCHEMATIC SEIH9KTS1 & SEIH11KTS1 Only This diagram is provided for your reference of the internal wiring of your Strom-Electrical water heating product. No attempt should be made to change the internals of your water heater, doing so may be dangerous and will invalidate your warranty. Your product MUST always be wired by a qualified electrician in accordance with all the relevent regulations and laws in place at the time of installation.

PRODUCT MOUNTING Please remove the hanger bracket from the back of the water heater, and position on the wall in the orientation shown below. Drill three 6.00mm holes in accordance with the hanger bracket, these holes should be 100mm apart as shown below. Using wall plugs and suitably long screws secure the hanger bracket to the wall. Once the hanger bracket is installed and secure the heater unit can be mounted to the bracket. INSTALLATION Once your product has been sited in accordance with the diagrams above please connect your product to the mains water supply using a 1/2 tap hose to the blue connection of the unit, NOTE: a check valve should be fitted before your electrical water heater. Fit the supplied filter between the unit and the hose. We suggest fitting an isolation valve and ball valve before the unit to facilitate removal of the tap and servicing. Once the cold mains has been fitted you may use another 1/2 tap hose to connect your heater to the properties hot pipework circuit (this circuit could be 1 outlet or multiple outlets, please ensure your unit is capable of heating the number of outlets you are asking it to). REMEMBER: Before turning off the water supply to the unit you must isolate its electric supply, operating the unit while there is no water can cause premature failure and invalidate your warrenty. DO NOT turn on your electric supply at this time.

COMISSIONING 1. Please flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater. Allow all air, and debris to pass before closing the hot tap. 2. Turn on the power supply to the heater. 3. Using the button please turn the heater up to 45 o C. 4. When set, open as many hot outlets as likely to be used at once on the circuit, and adjust the ball valve until the temperature output at the taps matches that on the display of the unit. Increase or decrease the flow until just before the temperature drops, increasing the flow will make the target harder to achieve, decreasing the flow makes it easier to achieve. 5. This optimises the flow rate for 45 o C, if you wish to optimise for a different temperature, please set the device at the required temperature and repeat step 4. REMEMBER: Adjusting the flow to the unit up or down controls the flow at the tap which makes it easier or harder to achieve the set temperature. This may require some balancing to achieve the best results for your scenario. 6. The comissioning of your system is now complete. GENERAL USE Operation of this unit is simple: The heater automatically detects flow, so as soon as a tap is opened the heater will instantly begin to heat the flow of water in accordance with the settings provided to the heater. To control the output temperature of the heater use and buttons to set the target temperature. The LED display will show you the target temperature that has been set on the device. TOP TIP: If the unit is installed in a cupboard once the temperature has been set the cupboard can be locked, this prevents the temperature from being changed and makes the product safer for children. MAINTENANCE Always turn off the power supply before servicing your unit To ensure a long lasting and efficient product we recommend the following maintenance regime: The filter washer supplied and fitted should be cleaned to reduce any debris build up and ensure good consistent flow rates.

TROUBLESHOOTING SYSTEM ISSUE LIKELY CAUSE POSSIBLE SOLUTION Inlet or Outlet are leaking Fittings not tight enough Tighten the fittings Rubber seals have worn out Replace rubber seals There is no LED display The power supply is not live Get electrician to check supply LED Screen is damaged Have the LED Screen replaced Function keys not working There is no water flow Open a tap to allow flow Water is too hot Water is too cold Outlet flow rate is getting slower Water pressure is too low Key or PCB is damaged Temperature is set too high The water flow is too slow Temperature is set too low The water flow is too fast Inlet strainer is clogged Increase water pressure Replace the PCB Using the function keys reduce the target temperature Increase the flow to the unit Using the function keys increase the target temperature Reduce the flow to the unit Clean the filter washer out LED display shows E1 Outlet temperature is over 67 o C Reduce the set temperature Increase the water flow rate LED display shows E2 There is electricity leakage Please contact your electrician LED display shows E3 Temperature Sensor Failure Please contact Strom-Electrical GUARANTEE Your Strom-Electrical water heater is guaranteed for a period of 12 months from the date of purchase. The unit is only guaranteed if the water heater has been installed and maintained in accordance with these instructions. Full guarantee information can be found at: www.strom-electrical.com/guarantee The guarantee specifically excludes: Corrosion by incorrect maintenance of the water heater, or incorrect installation. Limscale build up. Consequential losses, including labour charges and damages to fittings. Any water heater that has not been maintained and installed in accordance with this manual.

www.strom-electrical.com STROM- ELECTRICAL www.strom-electrical.com