Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

Similar documents
Operating Instructions OPTISWITCH 3100 C with transistor output

Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

Operating Instructions KSR-TF 611 with transistor output

Operating Instructions KSR-TF 633 with transistor output

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

Operating Instructions VEGASWING 63 - double relay (DPDT)

Operating Instructions VEGASWING 63 - transistor (NPN/PNP)

DC Disconnect with remote control and arc fault detection PVREM-...-AF1

ELECTRIC UNDERFLOOR HEATING

Electrorad Digi-Line. Installation, Operating & Instruction Manual. After Sales Service:

Instruction Manual September 2010 SITRANS LVL200S

Operating Instructions Indicating and adjustment module PLICSCOM

MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL. heatingthroughinnovation. APRIL 2013

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

Instruction Manual September 2010 SITRANS LVL200S

Thermo shaker PHMP/ PHMP-4

Think FATI for Hot Solutions

AUTOMATIC MARINE AND RV TOILETS

Thermo shaker PHMP/ PHMP-4

Fire Alarm Panel - User Manual

General terms and conditions... F-7 Glossary of terms... P.1455~ panasonic.net/id/pidsx/global

Mica insulated band heaters

ORDER GUIDE. 5 m ft cable length type. Accessories. Robust Photoelectric Sensor RX SERIES

Ceramic insulated band heaters

HAZARDOUS AREA. The very best in high pressure water jetting systems SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING

Small is beautiful and useful anywhere... Electric "Point of Use" Water Heaters "Open-Outlet" for single outlet "Unvented" for one or more outlets

SKYSTAR water cassette Main components:

ANCILLARY DEVICES. Contents. Fire System Document Box. EN54-4 Approved Power Supply Units. Transformer Rectifier 24v Door Retainer Power Supply Units

Mica insulated flat heaters

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - two-wire With SIL qualification

BC80A compact product catalog.

Clean and simple waste water removal

Operating Manual. Model Coolant Exchanger

ANALOGUE FIRE DETECTION SENTRI SYSTEM

Globo H. Ball valves Gunmetal ball valve

List of Contents Air Top 2000 NOTE

DETERGENT & RINSE AID INJECTION

ARG 1

Operating Instructions 11/2016

PRODUCT CATALOG MEDICAL AUTOCLAVE.

INSTRUCTION MANUAL AND WARRANTY

Caleo Neonatal incubator Software 2.n Instructions for Use Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care

INDIA S MOST POWER SAVING INVERTER AC

iii. Compatible Loop Devices and Panel Responses 27 IMPORTANT NOTE: Read the instructions carefully before commencing installation and commissioning.

Operating Instructions VEGASWING 63. Vibrating level switch with tube extension for liquids. - two-wire. Document ID: 29232

Turbosteam iron steam/spray/steam boost

a guide to watering your garden

Spray Etching Device

Undercounter Dishwasher

Nexus 1-8 Loop (A1557) Analogue Addressable Control Panel Application Guide

30 and 36 m Sealed Burner

Underc Dishwasher. IMPORTANT: Read and save these instryctions. 8

Vibrating Switches SITRANS LVL200S TRANSISTOR (NPN/PNP) Operating Instructions 11/2016. Siemens Contro

Take control with... Energy Efficient Controls

UseAndCare. -. wh H 01. nawtouua*naur~- I Call our Comumw Aubtmnca Center with quwiion* cf ccmmonb. AIR CONDITIONERS

ComfiGrip iron steam/spray/shot/press

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Operating Instructions 11/2016

PRODUCT CATALOG MEDICAL REFRIGERATOR. LABSTAC LTD, Kemp House, 152 City Road, London EC1V 2NX, United Kingdom. labstac.

. Ev d & AUTOMATIC WASHER

Operating Instructions 11/2016

INUI-LEDSDL10 Specification

MANUAL DE INSTALACIÓN

VRV AURORA AIR-COOLED SYSTEMS

CONVENTIONAL FIRE DETECTION

EPLE Air-Cooled. Chillers. EUWA*5-24KZ / EUWY*5-24KZ Hydronic systems

Classic ECO. Eco Series -86 C Ultra-low Freezer KM-DU34H1E

ASPIRATING SMOKE DETECTION SYSTEMS

Our home standard. Your home is where our heart is...

Installation and Operating Instructions

INSTALLATION INSTRUCTION

Operating Instructions 11/2016

Undercounter Dishwasher

36 Electric Modular Downdraft Cooktop

SSimdex and Power-Limited Fire Alarm Systems Operating and Installation Instructions

Buderus. Quality Doesn t Cost It Saves! Comfortable. Efficient. Intelligent Heating. GA124 GA244 Gas Boilers Sealed Combustion Draft Induced.

DESIGN AND APPLICATION GUIDE VISUAL ALARMS

Motion & Presence Detectors

SECTION 6: page. by Honeywell. Section 6: Vigilon Loop Devices

ASPIRATING SMOKE DETECTION SYSTEMS

Instructions for Installation and Use 50cm Free Standing Electric Cooker

REFRIGERANTS. Refrigerants

UseAndCare I 301 Call our Consumer Assistance Center with questions or comments. 22 TO 25 NO-FROST TOP FREEZER REFRIGERATOR

Air Vents AV-406. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Machinery Space Fire Protection System from an Approved Product Portfolio

REFRIGERATOR-FREEZER 8ET17NK 3ET16NK. Use And Care Guide. ~qq

UseAndCare I 301 NO-FROST REFRIGERATOR-FREEZER

INSTRUCTIONS FOR OPERATION AND CARE OF

NO-FROST REFRIGERATOR-FREEZERS Ell8DK Ell8RK

SELF-CLEANING DESIGNERSTYLE ELECTRIC SET-IN RANGE


UseAndCare. TLidl Call our Consumer Assistance Center with questions or comments.

UseAndCare. T&f1 HOme Appliances 01. A Note To You. Important Safety Instructions. Parts And Features. Using Your. Refrigerator. Caring For Your 15

REQUIRED CONDITIONS FOR OPTIONAL OPERATION OF AN AIR-CONDITIONING SYSTEM

50cm Free Standing Electric Cooker. Instructions for installation and use KD3C1/G KD3C11/G

by Honeywell THE VIGILON SYSTEM BROCHURE

''HEAT TRANSFER STUDIES"

l SEE INSTALLATION w 1 INSTRUCTIONS. Our Consumer Assistance Center number, I 301, is toll-free, 24 hours a day.

Take control with... 1

Transcription:

Operating Instructions OPTISWITCH 3100 C with contactess eectronic switch

Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symboism used... 4 2 For your safety 2.1 Authorised personne... 5 2.2 Appropriate use.... 5 2.3 Warning about misuse... 5 2.4 CE conformity... 5 2.5 SIL conformity... 6 2.6 Safety instructions for Ex areas... 6 3 Product description 3.1 Configuration.... 7 3.2 Principe of operation.... 7 3.3 Operation... 8 3.4 Storage and transport... 9 4 Mounting 4.1 Genera instructions.... 10 4.2 Mounting instructions.... 11 5 Connecting to votage suppy 5.1 Preparing the connection... 15 5.2 Connection steps.... 15 5.3 Wiring pan, singe chamber housing.... 16 6 Set up 6.1 Genera.... 19 6.2 Adjustment eements... 19 6.3 Function chart... 20 7 Maintenance and faut rectification 7.1 Maintenance... 22 7.2 Rectify fauts... 22 7.3 Exchange the eectronics... 23 7.4 Instrument repair... 24 8 Dismounting 8.1 Dismounting procedure... 25 8.2 Disposa... 25 2 OPTISWITCH 3100 C - with contactess eectronic switch

Contents 9 Suppement 9.1 Technica data.... 26 9.2 Dimensions... 29 Suppementary operating instructions manuas Information: OPTISWITCH 3100 C is avaiabe in different versions. Depending on the seected version, suppementary operating instructions manuas may aso come with the shipment. The suppementary operating instructions manuas are isted in section "Product description. Operating instructions manuas for accessories and repacement parts Tip: To ensure reiabe setup and operation of your OPTISWITCH 3100 C, we offer accessories and repacement parts. The associated documents are: Operating instructions manua "Osciator" OPTISWITCH 3100 C - with contactess eectronic switch 3

About this document 1 About this document 1.1 Function This operating instructions manua has a the information you need for quick setup and safe operation. Pease read this manua before you start setup. 1.2 Target group This operating instructions manua is directed to trained, quaified personne. The contents of this manua shoud be made avaiabe to these personne and put into practice by them. 1.3 Symboism used Information, tip, note This symbo indicates hepfu additiona information. Caution: If this warning is ignored, fauts or mafunctions can resut. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can resut. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can resut. Ex appications This symbo indicates specia instructions for Ex appications. à List The dot set in front indicates a ist with no impied sequence. Action This arrow indicates a singe action. 1 Sequence Numbers set in front indicate successive steps in a procedure. 4 OPTISWITCH 3100 C - with contactess eectronic switch

For your safety 2 For your safety 2.1 Authorised personne A operations described in this operating instructions manua must be carried out ony by trained speciaist personne authorised by the operator. For safety and warranty reasons, any interna work on the instruments must be carried out ony by personne authorised by the manufacturer. 2.2 Appropriate use OPTISWITCH 3100 C is a sensor for eve detection. Detaied information on the appication range of OPTISWITCH 3100 C is avaiabe in chapter "Product description". 2.3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to appication-specific hazards, e.g. vesse overfi or damage to system components through incorrect mounting or adjustment. 2.4 Genera safety instructions OPTISWITCH 3100 C is a high-tech instrument requiring the strict observance of standard reguations and guideines. The user must take note of the safety instructions in this operating instructions manua, the country-specific instaation standards (e.g. the VDE reguations in Germany) as we as a prevaiing safety reguations and accident prevention rues. 2.5 CE conformity OPTISWITCH 3100 C is in CE conformity with EMC (89/336/ EWG), fufis NAMUR recommendation NE 21 and is in CE conformity with LVD (73/23/EWG). Conformity has been judged according to the foowing standards: EMC: - Emission EN 61326/A1: 1998 (cass B) - Susceptibiity EN 61326: 1997/A1:1998 LVD: EN 61010-1: 2001 The instrument is designed for industria use. OPTISWITCH 3100 C - with contactess eectronic switch 5

For your safety 2.6 SIL conformity OPTISWITCH 3100 C fufis the requirements of functiona safety according to IEC 61508/IEC 61511. You can find further information in the suppementary instructions manua "Safety Manua - Functiona safety (SIL) OPTISWITCH 3XXX". 2.7 Safety instructions for Ex areas Pease note the Ex-specific safety information for instaation and operation in Ex areas. These safety instructions are part of the operating instructions manua and come with the Exapproved instruments. 6 OPTISWITCH 3100 C - with contactess eectronic switch

Product description 3 Product description 3.1 Configuration Scope of deivery Components The scope of deivery encompasses: OPTISWITCH 3100 C eve sensor Documentation - this operating instructions manua - Suppementary instructions manua "Pug connector for eve sensors" (optiona) - Ex specific safety instructions (with Ex versions), if necessary further certificates OPTISWITCH 3100 C consists of the foowing components: Housing cover Housing with eectronics process fitting with tuning fork 1 2 3 Fig. 1: OPTISWITCH 3100 C with pastic housing 1 Housing cover 2 Housing with eectronics 3 Process fitting 3.2 Principe of operation Area of appication OPTISWITCH 3100 C is a eve sensor with tuning fork for eve detection. It is designed for industria use in a areas of process technoogy and is preferaby used for buk soids. Typica appications are overfi and dry run protection. Thanks to its simpe and robust measuring system, OPTISWITCH 3100 C is virtuay unaffected by the chemica and physica properties of the buk soid. OPTISWITCH 3100 C - with contactess eectronic switch 7

Product description It functions even when exposed to strong externa vibration or changing products. Soid detection in water If OPTISWITCH 3100 C was ordered for detection of soids in water, the tuning fork is adjusted to the density of water. In the air or when covered by water (density: 1 g/cm³/0.036 bs/in) OPTISWITCH 3100 C signas "uncovered". Ony if the vibrating eement is aso covered with soids (e.g. sand, sudge, grave etc.) wi the sensor signa "covered". Faut monitoring The eectronics of OPTISWITCH 3100 C continuousy monitors the foowing criteria: Correct vibrating frequency Line break to the piezo drive If one of the stated mafunctions is detected or in case of power faiure, the eectronics takes on a defined switching condition, i.e. the contactess eectronic switch opens (safe condition). Physica principe Power suppy The tuning fork is piezoeectricay energised and vibrates at its mechanica resonance frequency of approx. 150 Hz. When the tuning fork is submerged in the product, the vibration ampitude changes. This change is detected by the integrated osciator and converted into a switching command. OPTISWITCH 3100 C is a compact instrument, i.e. it can be operated without externa evauation system. The integrated eectronics evauates the eve signa and outputs a switching signa. With this switching signa, a connected device can be directy activated (e.g. a warning system, a PLC, a pump etc.). The exact range of the power suppy is stated in the "Technica data" in the "Suppement". 3.3 Operation With the factory setting, products with a density of >0.02 g/cm³ (>0.0008 bs/in³) can be measured. The instrument can aso be adapted to products with ower density >0.008 g/cm³ (>0.0003 bs/in³). On the eectronics modue you wi find the foowing indicating and adjustment eements: signa amp for indication of the switching condition (green/ red) 8 OPTISWITCH 3100 C - with contactess eectronic switch

Product description potentiometer for adaptation to the product density Mode switch for seecting the switching condition (min./ max.) 3.4 Storage and transport Packaging Storage and transport temperature Your instrument was protected by packaging during transport. Its capacity to hande norma oads during transport is assured by a test according to DIN 55439. The packaging of standard instruments consists of environment-friendy, recycabe cardboard. In addition, the sensor is provided with a protective cover of cardboard. For specia versions PE foam or PE foi is aso used. Dispose of the packaging materia via speciaised recycing companies. Storage and transport temperature see "Suppement - Technica data - Ambient conditions" Reative humidity 20 85 % OPTISWITCH 3100 C - with contactess eectronic switch 9

Mounting 4 Mounting 4.1 Genera instructions Switching point Moisture In genera, OPTISWITCH 3100 C can be mounted in any position. The instrument must be mounted in such a way that the vibrating eement is at the height of the requested switching point. Use the recommended cabes (see chapter "Connecting to power suppy") and tighten the cabe gand. You can give your OPTISWITCH 3100 C additiona protection against moisture penetration by eading the connection cabe downward in front of the cabe entry. Rain and condensation water can thus drain off. This appies mainy to mounting outdoors, in areas where moisture is expected (e.g. by ceaning processes) or on cooed or heated vesses. Fig. 2: Measures against moisture penetration Transport Do not hod OPTISWITCH 3100 C on the vibrating eement. Especiay with fange and tube versions, the sensor can be damaged by the weight of the instrument. Remove the protective cover just before mounting. Pressure/Vacuum The process fitting must be seaed if there is gauge or ow pressure in the vesse. Before use, check if the sea materia is resistant against the measured product and the process temperature. The max. permissibe pressure is stated in the "Technica data" in the "Suppement" or on the type abe of the sensor. 10 OPTISWITCH 3100 C - with contactess eectronic switch

Mounting Handing The vibrating eve switch is a measuring instrument and must be treated accordingy. Bending the vibrating eement wi destroy the instrument. Warning: The housing must not be used to screw in the instrument! Appying tightening force on the housing can damage its interna mechanica parts. To screw in, use the hexagon above the thread. 4.2 Mounting instructions Socket Fiing opening The vibrating eement shoud protrude into the vesse to avoid buidup. For that reason, avoid using mounting bosses for fanges and screwed fittings. This appies particuary to use with adhesive products. Mount the instrument in such a way that the tuning fork does not protrude directy into the fiing stream. a. b. 20 Fig. 3: Horizonta mounting a Convex mounting b Concave mounting If such an instaation ocation shoud be necessary, mount a suitabe protective sheet above or in front of the vibrating eement - see iustration a.). OPTISWITCH 3100 C - with contactess eectronic switch 11

Mounting In abrasive soids, mounting according to iustration b. has proven. A spout forms in the concave protective sheet preventing wear of the protective sheet. Horizonta mounting To achieve a very precise switching point, you can insta OPTISWITCH 3100 C horizontay. However, if the switching point can have a toerance of a few centimeters, we recommend mounting OPTISWITCH 3100 C approx. 20 incined to the vesse bottom to avoid buidup. a. b. 20 Fig. 4: Horizonta mounting a Protective sheet b Concave protective sheet for abrasive soids Infowing medium Fows If OPTISWITCH 3100 C is mounted in the fiing stream, unwanted switching signas may be generated. Mount OPTI- SWITCH 3100 C at a ocation in the vesse where no disturbing infuence from e.g. fiing openings, agitators etc. can occur. To minimise fow resistance caused by the tuning fork, OPTISWITCH 3100 C shoud be mounted in such a way that the surfaces of the bades are parae to the product movement. 12 OPTISWITCH 3100 C - with contactess eectronic switch

Mounting 1 2 Fig. 5: Orientation of the tuning fork in case of fow 1 Marking with screwed version 2 Direction of fow Adhesive products In case of horizonta mounting in adhesive products, the surfaces of the tuning fork shoud be vertica in order to reduce buidup on the bades. On the screwed version you wi find a marking on the hexagon. With this, you can check the position of the tuning fork when screwing it in. When the hexagon touches the sea, the thread can be sti turned by approx. haf a turn. This is sufficient to reach the recommended instaation position. With fange versions, the fork is directed to the fange hoes. 1 Baffe protection against faing rocks Fig. 6: Vertica instaation - marking 1 Marking on top with screwed version In appications such as grit chambers or setting basins for coarse sediments, the vibrating eement must be protected against damage with a suitabe baffe. This baffe must be manufactured by you. OPTISWITCH 3100 C - with contactess eectronic switch 13

Mounting >125 Fig. 7: Baffe protection against damages 14 OPTISWITCH 3100 C - with contactess eectronic switch

Connecting to votage suppy 5 Connecting to votage suppy 5.1 Preparing the connection Note safety instructions Take note of safety instructions for Ex appications Seect power suppy Seecting the connection cabe Generay not the foowing safety instructions: Connect ony in the compete absence of ine votage In hazardous areas you shoud take note of the appropriate reguations, conformity and type approva certificates of the sensors and power suppy units. Connect the power suppy according to the foowing diagrams. Osciator WE60C is designed in protection cass 1. To maintain this protection cass, it is absoutey necessary that the ground conductor be connected to the interna ground termina. Take note of the genera instaation reguations. As a rue, connect OPTISWITCH 3100 C to vesse ground (PA), or in case of pastic vesses, to the next ground potentia. On the side of the housing there is a ground termina between the cabe entries. This connection serves to drain off eectrostatic charges. In Ex appications, the instaation reguations for hazardous areas must be given priority. The data for power suppy are stated in the "Technica data" in the "Suppement". OPTISWITCH 3100 C is connected with standard cabe with round cross-section. An outer cabe diameter of 5 9 mm (0.2 0.35 in) ensures the sea effect of the cabe entry. If cabe with a different diameter or wire cross section is used, exchange the sea or use an appropriate cabe connection. In hazardous areas, ony use approved cabe connections for OPTISWITCH 3100 C. Seect connection cabe for Ex appications Take note of the corresponding instaation reguations for Ex appications. 5.2 Connection steps With Ex instruments, the housing cover may ony be opened if there is no exposive atmosphere present. Proceed as foows: OPTISWITCH 3100 C - with contactess eectronic switch 15

Connecting to votage suppy 1 Unscrew the housing cover 2 Loosen compression nut of the cabe entry 3 Remove approx. 10 cm (4 in) of the cabe mante, strip approx. 1 cm (0.4 in) insuation from the ends of the individua wires 4 Insert the cabe into the sensor through the cabe entry 5 Lift the opening evers of the terminas with a screwdriver (see foowing iustration) 6 Insert the wire ends into the open terminas according to the wiring pan 7 Press the opening ever of the terminas downward, you wi hear the termina spring cosing 8 Check the hod of the wires in the terminas by ighty puing on them 9 Tighten the compression nut of the cabe entry, the sea ring must competey encirce the cabe 10 If necessary, carry out a fresh adjustment 11 Screw the housing cover back on The eectrica connection is hence finished. Fig. 8: Connection steps 5 and 6 5.3 Wiring pan, singe chamber housing The foowing iustrations appy to the non-ex as we as to the EEx d version. 16 OPTISWITCH 3100 C - with contactess eectronic switch

Connecting to votage suppy Housing overview 4 4 4 1 2 3 Fig. 9: Materia versions, singe chamber housing 1 Pastic (not with EEx d) 2 Auminium 3 Stainess stee (not with EEx d) 4 Fiter eement for pressure compensation (not with EEx d) Eectronics and connection compartment 1 5 2 4 3 Fig. 10: Eectronics and connection compartment 1 Potentiometer for switching point adaptation (covered) 2 DIL switch for mode adjustment 3 Ground termina 4 Screwed terminas 5 Contro amp Wiring pan We recommend connecting OPTISWITCH 3100 C in such a way that the switching circuit is open when there is a eve signa, ine break or faiure (safe condition). The contactess eectronic switch is aways shown in nonoperative condition. The instrument is used for direct contro of reays, contactors, magnet vaves, warning ights, horns etc. It must not be operated without an intermediatey connected oad, because OPTISWITCH 3100 C - with contactess eectronic switch 17

Connecting to votage suppy the eectronics woud be destroyed if connected directy to the mains. It is not suitabe for connection to ow votage PLC inputs. Domestic current is temporariy owered beow 1 ma after switching off the oad so that contactors, whose hoding current is ower than the constant domestic current of the eectronics, are reiaby switched off. 1 Fig. 11: Wiring pan 1 Screen 18 OPTISWITCH 3100 C - with contactess eectronic switch

Set up 6 Set up 6.1 Genera The numbers in brackets refer to the foowing iustrations. Function/Configuration On the eectronics modue you wi find the foowing indicating and adjustment eements: Potentiometer for switching point adaptation (1) DIL switch for mode adjustment - min./max. (2) Signa amp (5) Note: As a rue, aways set the mode with mode switch (2) before starting the setup of OPTISWITCH 3100 C. The switching output wi change if you set the mode switch (2) afterwards. This coud possiby trigger other connected instruments or devices. 6.2 Adjustment eements 5 1 2 4 3 Fig. 12: Osciator WE60C - Contactess eectronic switch 1 Potentiometer for switching point adaptation 2 DIL switch for mode adjustment 3 Ground termina 4 Screwed terminas 5 Contro amp OPTISWITCH 3100 C - with contactess eectronic switch 19

Set up Switching point adaptation (1) Mode adjustment (2) Signa amp (5) With the potentiometer you can adapt the switching point to the soid. It is aready preset and must ony be modified in specia cases. By defaut, the potentiometer of OPTISWITCH 3100 C is set to the right stop (>0.02 g/cm³ or >0.0008 bs/in³). In case of very ight-weight soids, turn the potentiometer to the eft stop (>0.008 g/cm³ or >0.0003 bs/in³). OPTISWITCH 3100 C wi thus be more sensitive and can detect ight-weight soids more reiaby. For instruments detecting soids in water, these vaues are not appicabe. The potentiometer is preset and must not be changed. With the mode adjustment (min./max.) you can change the switching condition of the output. You can set the required mode acc. to the "Function chart" (max. -max. detection or overfi protection, min. -min. detection or dry run protection). We recommend connecting acc. to the quiescent current principe (contactess eectronic switch is open when the switching point is reached) because the contactess eectronic switch takes on the same (safe) condition if a faiure is detected. Contro amp for indication of the switching condition. green = switch cosed red = switch open red (fashing) = faiure 6.3 Function chart The foowing chart provides an overview of the switching conditions depending on the adjusted mode and eve. Mode max. Overfi protection Leve Switching status Contro amp 1 2 Mode max. Overfi protection Switch cosed 1 2 Switch open Green 20 OPTISWITCH 3100 C - with contactess eectronic switch red

Set up Mode min. Dry run protection Leve Switching status Contro amp 1 2 Mode min. Dry run protection Switch cosed Green 1 2 Faiure of the suppy votage (min./max. mode) any Switch open red 1 2 Switch open Faiure any 1 2 Switch open fashes red OPTISWITCH 3100 C - with contactess eectronic switch 21

Maintenance and faut rectification 7 Maintenance and faut rectification 7.1 Maintenance When used as directed in norma operation, OPTISWITCH 3100 C is competey maintenance free. 7.2 Rectify fauts Causes of mafunction Faut rectification OPTISWITCH 3100 C offers maximum reiabiity. Nevertheess fauts can occur during operation. These may be caused by the foowing, e.g.: Sensor Process Power suppy Signa processing The first measure to be taken is to check the output signa. In many cases, the causes can be determined this way and the fauts rectified. Checking the switching signa? OPTISWITCH 3100 C signas "covered" when the vibrating eement is not submerged (overfi protection)? OPTISWITCH 3100 C signas "uncovered" when the vibrating eement is submerged (dry run protection) Suppy votage too ow à Check the power suppy Eectronics defective à Press the mode switch (min./max.). If the instrument then changes the mode, the instrument may be mechanicay damaged. Shoud the switching function in the correct mode sti be fauty, return the instrument for repair. à Push the mode switch. If the instrument then does not change the mode, the osciator may be defective. Exchange the osciator. à Check if there is buidup on the vibrating eement, and if so, remove it. Unfavourabe instaation ocation à Mount the instrument at a ocation in the vesse where no dead zones or mounds can form. à Check if the vibrating eement is covered by buidup on the socket. 22 OPTISWITCH 3100 C - with contactess eectronic switch

Maintenance and faut rectification Wrong mode seected à Set the correct mode on the mode switch (max.: overfi protection; min.: dry run protection). Wiring shoud be carried out according to the quiescent current principe.? Signa amp fashes red Eectronics has detected a faiure à Exchange instrument or return instrument for repair 7.3 Exchange the eectronics In genera, a osciators of series WE60 can be interchanged. If you want to use an osciator with a different signa output, you can downoad the corresponding operating instructions manua from our homepage under Downoads. With EEx d instruments, the housing cover must ony be opened if there is no exposive atmosphere. Proceed as foows: 1 Switch off power suppy 2 Unscrew the housing cover 3 Lift the opening evers of the terminas with a screwdriver 4 Pu the connection cabes out of the terminas 5 Loosen the two screws with a screw driver (Torx size T10 or sot 4) 1 2 Fig. 13: Loosen the screws 1 Eectronics modue 2 Screws (2 pcs.) OPTISWITCH 3100 C - with contactess eectronic switch 23

Maintenance and faut rectification 6 Remove the od osciator 7 Compare the new osciator with the od one. The type abe of the osciator must correspond to that of the od osciator. This appies particuary to instruments used in hazardous areas. 8 Compare the settings of the two osciators. Set the adjustment eements of the new osciator to the same setting of the od one. Information: Make sure that the housing is not rotated during the eectronics exchange. Otherwise the pug may be in a different position ater. 9 Insert the osciator carefuy. Make sure that the pug is in the correct position. 10 Tighten the two screws with a screwdriver (Torx size T10 or sot 4). 11 Insert the wire ends into the open terminas according to the wiring pan 12 Press the opening ever of the terminas downward, you wi hear the termina spring cosing 13 Check the hod of the wires in the terminas by ighty puing on them 14 Check the tightness of the cabe entry. The sea ring must competey encirce the cabe. 15 Screw the housing cover back on The eectronics exchange is now finished. 7.4 Instrument repair If a repair is necessary, pease proceed as foows: You can downoad a return form from our website http://www. krohne-mar.com/fieadmin/media-ounge/pdf-downoad/ Specimen_e.pdf. By doing this you hep us carry out the repair quicky and without having to ca back for needed information. Print and fi out one form per instrument Cean the instrument and pack it damage-proof Attach the competed form and possiby aso a safety data sheet to the instrument 24 OPTISWITCH 3100 C - with contactess eectronic switch

Dismounting 8 Dismounting 8.1 Dismounting procedure Warning: Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vesse, high temperatures, corrosive or toxic products etc. Take note of chapters "Mounting" and "Connecting to power suppy" and carry out the isted steps in reverse order. With Ex instruments, the housing cover may ony be opened if there is no exposive atmosphere present. 8.2 Disposa The instrument consists of materias which can be recyced by speciaised recycing companies. We use recycabe materias and have designed the eectronic modues to be easiy separabe. WEEE directive 2002/96/EG This instrument is not subject to the WEEE directive 2002/96/ EG and the respective nationa aws (in Germany, e.g. EektroG). Pass the instrument directy on to a speciaised recycing company and do not use the municipa coecting points. These may be used ony for privatey used products according to the WEEE directive. Correct disposa avoids negative effects to persons and environment and ensures recycing of usefu raw materias. Materias: see "Technica data" If you cannot dispose of the instrument propery, pease contact us about disposa methods or return. OPTISWITCH 3100 C - with contactess eectronic switch 25

Suppement 9 Suppement 9.1 Technica data Genera data Materia 316L corresponds to 1.4404 or 1.4435 Materias, wetted parts - Process fitting - thread 316L - Process fitting - fange 316L - Process sea Kingersi C-4400 - Tuning fork 316L - Extension tube ø 43 mm (1.7 in) 316L Materias, non-wetted parts - Housing Pastic PBT (Poyester), Au die-casting powder-coated, 316L - Sea ring between housing and housing cover - Ground termina 316L Weight - with pastic housing 1500 g (53 oz) - with Auminium housing 1950 g (69 oz) - with stainess stee housing 2300 g (81 oz) NBR (stainess stee housing), siicone (Au/ pastic housing) Max. atera oad 600 N (135 bf) ongitudina to the fork side Output variabe Output Contactess eectronic switch Modes (adjustabe) min./max. Integration time - when immersed approx. 0.5 s - when aid bare approx. 1 s Ambient conditions Ambient temperature on the housing Storage and transport temperature -40 +80 C (-40 +176 F) -40 +80 C (-40 +176 F) Process conditions Parameter Limit eve of soids 26 OPTISWITCH 3100 C - with contactess eectronic switch

Suppement Process pressure -1 16 bar/-100 1600 kpa (-14.5 232 psi) 2 16 bar (232psi) 6 bar (87psi) 1-50 C (-58 F) 0 C (32 F) 50 C (122 F) 100 C (212 F) 150 C (302 F) 200 C (392 F) 250 C (482 F) Fig. 14: Process pressure - Product temperature 1 Product temperature 2 Process pressure OPTISWITCH 3100 C of 316L Process temperature (thread or fange temperature) with temperature adapter (option) -50 +150 C (-58 +302 F) -50 +250 C (-58 +482 F) 2 80 C (176 F) 3 40 C (104 F) 0 C (32 F) -50 C (-58 F) -40 C (-40 F) 50 C (122 F) 100 C (212 F) 150 C (302 F) 200 C (392 F) 1 250 C (482 F) Fig. 15: Ambient temperature - Product temperature 1 Product temperature 2 Ambient temperature 3 Temperature range with temperature adapter Density - Standard >0.02 g/cm³ (0.0007 bs/in³) - adjustabe >0.008 g/cm³ (0.0003 bs/in³) OPTISWITCH 3100 C - with contactess eectronic switch 27

Suppement Eectromechanica data Cabe entry/pug (dependent on the version) - Singe chamber housing 1x cabe entry M20x1.5 (cabe-ø 5 9 mm), 1x bind stopper M20x1.5, attached 1x cabe entry M20x1.5 or: 1x cabe entry ½ NPT, 1x bind stopper ½ NPT, 1x cabe entry ½ NPT or: Spring-oaded terminas 1x pug M12x1, 1x bind stopper M20x1.5 for wire cross-section up to 1.5 mm² (0.0023 in²) Adjustment eements Mode switch - min. Min. detection or dry run protection - max. Max. detection or overfi protection Votage suppy Suppy votage 20 253 VAC, 50/60 Hz, 20 253 VDC Domestic current requirement approx. 3 ma (via oad circuit) Load current - min. 10 ma - max. 400 ma (at I >300 ma the ambient temperature can be max. 60 C/140 F) max. 4 A up to 40 ms Eectrica protective measures Protection IP 66/IP 67 Overvotage category III Protection cass I Approvas 1) ATEX II 1/2G, 2G EExd d IIC T6 ATEX II 1/2 DIP66 T 1) Deviating data in Ex appications: see separate safety instructions. 28 OPTISWITCH 3100 C - with contactess eectronic switch

Suppement 9.2 Dimensions OPTISWITCH 3100 C ~ 69mm (2 23/ 32") ø 77mm (3 1/ 32") ~ 69mm (2 23/ 32") ø 77mm (3 1/ 32") ~ 116mm (4 9/ 16") ø 84mm (3 5/ 16") 112mm (4 13/32") 117mm (4 39/64") 114mm (4 31/64") ½ M20x1,5/ ½ NPT M20x1,5/ ½ NPT M20x1,5 1 2 3 Fig. 16: Housing versions 1 Pastic housing 2 Stainess stee housing 3 Auminium housing OPTISWITCH 3100 C - with contactess eectronic switch 29

Suppement 220mm (8 21/32") 150mm (5 29/32") 22mm (55/64") 33mm (1 19/64") G1½A ø 43mm (1 11/ 16 ") Fig. 17: OPTISWITCH 3100 C, threaded version G1½ A 30 OPTISWITCH 3100 C - with contactess eectronic switch

Suppement 178mm (7 1/64") ø 34mm (1 11/ 32 ") Fig. 18: Temperature adapter OPTISWITCH 3100 C - with contactess eectronic switch 31

Subject to change without notice