Firetex steel fire shutters

Similar documents
CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

A REVOLUTIONARY APPROACH TO FIRE SAFETY

PRODUCT SPECIFICATION FireMaster Plus

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

DAVITS INFORMATION & CERTIFICATION

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

PRODUCT SPECIFICATION FireMaster Plus Concertina

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

Strong, durable and built to last, you will have peace-of-mind when you have a Garador Industrial door installed.

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Remote Control Garage Doors

FIREMASTER CONCERTINA TM

Intelligent Security & Fire Ltd

Standards in Security Shutters & Fire Shutters (UK & USA)

Canopies. Enabling outdoor spaces to be used, whatever the weather

Installation and user manual for the BiWire / Conventional Repeater Panel

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

FIRE DOOR CLOSING SYSTEMS

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

Guide to: 17 th Edition Consumer Units

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

FireCurtain STANDARD, gray, with steel slats UL & C-UL LISTED. Phone: RAYNOR Fax:

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

BX444-Mc Gas Detector

Your specialist partner for total electrical compliance. Electrical Testing

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

Smoke and Fire Curtains

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Pressurisation units & expansion vessels

Your perfect PVC-U partner WINDOWS DOORS. spectus n. look, appearance, aspect

Deaf & Hearing Impaired RadioLINK Alarm System

Guide to sollysta Wiring Accessories

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

ASSA Lockcases. ASSA ABLOY, the global leader in door opening solutions

Intelligent Security & Fire Ltd

AUTOMATIC PEDESTRIAN ACCESS

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

HHIC consumer guide to gas boiler servicing

Services. Monitoring. t f e. w.

CP+ Gas & Oil Cabinet Heater Range

Underfloor Catalogue Heating products that define the market

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Abrasion Resistance of Fluoropolymer and polyester Coatings

Consultant Specification AGILE Wireless Fire Detection System

The new detector from Rafiki

Reliably Advanced Extinguishing Control

GS100M Gas Detection Controller

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Operating Instructions

Public Safety DAS Annunciator Panel

GS100M Gas Detector. Technical Specification

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Functional Performance Test

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Reliably Advanced Extinguishing Control

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

Firstcool BRIEF SPECIFICATION OF MATERIALS USED. INSULATION PANELS FOR COLD ROOMS REFRIGERATION UNITS CLADDING SHEETS ACCESSORIES INSULATED FLOORS

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

PRODUCT SPECIFICATION FireMaster Concertina

Openers ROLLING AND OVERHEAD SECTIONAL GARAGE DOORS

SECTION Overhead Coiling Doors

MOBILE PARTS WASHER MODEL No: CWM20

Heat Exchanger Excellence DESIGN BUILD SUPPLY INSTALL MAINTAIN.

Where gas is not an option,

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

SECTION OVERHEAD COILING FIRE DOORS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MINERVA MZX125 Digital Addressable Fire Detection System

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

dhf General Information Automated Gates Guidance for enforcement bodies

Performance Doorsets. Martin Roberts

C106 Coded Access Keypad

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

All by design. ASSA ABLOY Door Controls

INITIAL FIRE SAFETY ASSESSMENT

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

LIMITED METAL WARRANTY

MS SERIES ROLL COMPACTORS

BLOW DRY & GO HAIR KIT

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Transcription:

Firetex steel fire shutters

Firetex; safe, versatile and efficient Firetex shutters are a range of proven fire and smoke control products meeting the requirements of building regulations and life safety systems. Designed for internal use, Firetex provides excellent fire resistance and smoke arrest as well as adding security protection. Firetex products are suitable for both industrial and commercial applications

Contents 4 Firetex 240 2-4 hour fire shutter 5 Firetex 60 1 hour fire shutter 6 Activation systems 7 Technical space requirements Firetex 240 2-4 hour fire shutter 8 Technical space requirements Firetex 60 controlled descent 1 hour fire shutter 9 Technical space requirements Firetex 60 tubular motor 1 hour fire shutter 10 Electrical requirements 11 Service, maintenance and repair Trust Gilgen Gilgen aims to consistently exceed customer expectations in the delivery of its products and services and by offering a comprehensive range of technologically advanced solutions. Extensive experience and industry knowledge means you can trust Gilgen to give unbiased guidance and advice, working in partnership with customers to ensure individual needs are met and expectations exceeded. Quality guaranteed Gilgen s quality accreditation and industry association memberships give assurance of the high standards of service and workmanship you can expect to receive. Additionally, membership of bodies such as Constructionline, CHAS and SafeContractor give assurance of health and safety excellence.

Firetex 240 2-4 hour fire shutter 4 The Firetex 240 fire shutter has been designed and tested to provide up to 4 hours fire resistance. Specifically designed for internal low cycle use, the Firetex 240 is intended to be left in the open position for automatic activation in the event of a fire alarm signal or power failure. It can be closed for security purposes by means of push button. The power operated single skinned steel shutter consists of concave, solid profiles and features an integral smoke check and curtain suspension system incorporating manual controlled descent closing. corresponding rail fitted to the shutter locates when fully closed creating a seal to reduce smoke leakage. A comparative smoke leakage demonstration between a smoke check shutter and a conventional shutter, clearly demonstrates in both fan-on and fan-off situations that there is a significant reduction in the volume of leakage. Operation is via a 3 phase - 415 volt controlled descent motor. Firetex 240 is tested to meet BS476 part 22. Door section materials are class A2 (non-flammable) Options * Polyester powder coating to main visible parts (BS4800/RAL colour range) Galvanised steel hood (head casing to roller barrel assembly not required for fire performance) Galvanised motor cover *finish may deteriorate with frequent usage due to the inherent rolling action of this type of door Curtain support/smoke check system Shutter fitted with a smoke check system The patented smoke check system holds the shutter under gravity tension against a support rail fixed to the lintel; the Shutter without a smoke check system Patented curtain support rail

Firetex 60 1 hour fire shutter 5 The Firetex 60 has been designed for internal smaller apertures providing up to 1 hour fire resistance. The steel construction still maintains the benefits of security, automatic operation and fire resistance, but is ideal where space and appearance are important factors. Constructed from lighter gauge materials, the Firetex 60 features a compact three sided chamfered head box as standard. for security purposes by means of push button. Operation is via a single phase - 230 volt controlled descent motor or tubular motor. Firetex 60 has been tested and assessed for fire resistance in accordance with BS476 part 22 1987 and the door section element materials are Class A2 (nonflammable). Options * Polyester powder coating to main visible parts (BS4800/RAL colour range) Galvanised motor cover (CDO) Key operated locks mounted in to the curtain Steel threshold cill section *finish may deteriorate with frequent usage due to the inherent rolling action of this type of door Specifically designed for internal low cycle use, the Firetex 60 is intended to be left in the open position for automatic activation in the event of a fire alarm signal or power failure. It can be closed

Activation systems Standard firetex. Primary activation - shutter linked to main fire alarm signal (third party) Secondary activation - shutter release solenoid also equipped with fusible link to provide fail safe local heat activation. Standard firetex Primary activation - shutter linked to main fire alarm signal (third party connection) Secondary activation - monitored battery back up. Optional - Firegard control system with timed delay closing after alarm signal. Optional - Firegard control system with split drop delay closing after alarm signal. Option - Firegard control system with audible and visual output warning signs. Option - Firegard control system with safety beam. 6 Fire shutter linked to main fire alarm and monitored battery back up Model Firetex 240 Firetex 60 CDO Firetex 60 Tubular Fire shutter Linked to main fire alarm + fusible link p p Fire shutter linked to main fire alarm + monitored battery back up Timed delay closing r r r Split drop delay Audible/visual out put warning r r r r Safety beam Emergency retract r r r button Battery back up door r r p closing Fire control system. r r Battery back up door CDO release & out put signal to warning signs Integrated local heat/ r r r smoke detector Remote test switch r r r p Normal activation r optional activation

Technical space requirements Firetex 240 2-4 hour fire shutter 7 Maximum clear opening (mm) Space dimensions (mm) Width Height D1 D2 H1 H2 W1 W2 3000 2500 430 250 460 360 250 150 6000 3000 430 250 590 440 250 180 6000 5000 535 250 650 500 250 180 7000 3000 535 300 650 500 300 210 7000 7000 600 300 750 600 300 210 Standard range detailed. Larger doors are available on request.

Technical space requirements Firetex 60 controlled descent 1 hour fire shutter 8 Maximum sizes (mm) Width Height 2250 2250 2500 2000 2750 1750 3250 1500

Technical space requirements Firetex 60 tubular motor 1 hour fire shutter 9 Maximum sizes (mm) Width Height 2250 2250 2500 2000 2750 1750 3250 1500 Space dimensions (mm) Height D1 H1 H2 Up to 1800 250 280 250 Over 1800 300 330 300

Electrical requirements 6 6 5 2 1 5 2 1 7 2 1 4 4 3 3 3 4 5 6 10 Typical elevation - Firetex 240 Typical elevation - Firetex 60 controlled descent Typical elevation - Firetex 60 tubular 1. Tested 16 amp, 3 phase and neutral supply terminated to a 5 pin socket with optional lockable isolation switch. Breaker and cable size dependant on motor size. All by customer unless otherwise agreed. 2. 16 amp, 5 pin CEE plug with phase reversing pins. 3. Low level, low voltage door control push buttons. 4. Double insulated SY control cable and clips. 5. Brake release solenoid. 6. Fire alarm signal and connection into gilgen s solenoid release unit - by others - 24 volt DC, 0.37 A, pulse. Options Firegard control system is available to support additional activations and functionality contact Gilgen for further details 1. Tested 16 amp, 1 phase and neutral supply terminated to a 3 pin socket with optional lockable isolation switch. Breaker and cable size dependant on motor size. All by customer unless otherwise agreed. 2. 16 amp, 3 pin CEE plug. 3. Low level, low voltage door control push buttons. 4. Double insulated SY control cable and clips. 5. Brake release solenoid. 6. Fire alarm signal and connection into Gilgen s solenoid release unit - by others - 24 volt DC, 0.37 A, pulse. 1. Tested 16 amp, 1 phase and neutral supply terminated to a fused spur. Breaker and cable size dependant on motor size. All by customer unless otherwise agreed. 2. 400mm x 400mm square, high level control panel c/w status indication and battery back up. 3. Double insulated control cables and clips. 4. Optional low level status indication panel. 5. Low level paddle type switch for open and close. 6. Optional low level, sprung loaded key switch for open and close. 7. Fire alarm signal and connection into panel by others. Options. Pair of clean normally open volt free contacts -. closes on alarm.. Pair of clean normally closed volt free contacts - opens on alarm.. A 24v DC supply that is provided in an alarm condition.. A continuous 24v DC supply that is removed in an alarm condition.

Service, maintenance and repair 11 Maintenance Gilgen repair and maintain any type or make of automatic, revolving or industrial door, shutter gate or barrier. A nationwide network of strategically positioned offices guarantee s a fast response to customer needs by local engineers ensuring peace of mind 24 hours a day, 365 days a year. Engineers are highly skilled, trained to meet industry standards and always aim to exceed customer expectations. Our unrivalled product range fulfils customer needs for safe and secure access at all internal and external entrances and exits whilst ensuring compliance with current safety regulations such as the Equality Act and Regulation 6 of the Provision and Use of Work Equipment Regulations 1998 (PUWER). Repair Gilgen s extensively equipped workshops and well stocked vehicles ensure a speedy resolution to your access problems regardless of what make or type of door you have. Our 24 hour emergency call-out service offers security and peace of mind. Call us on 0870 000 2424. Planned preventative maintenance Planned preventative maintenance is the most effective way to ensure doors continue to work safely and effectively whilst optimising cost over lifetime. Contract maintenance not only avoids the development of costly faults but also ensures your doors operate effectively and efficiently meeting your fire and health and safety obligations. The frequency of visits will depend on the use of the door and the working environment. Gilgen will undertake a free inspection to assess your servicing needs and discuss your response requirements before offering a competitive quotation. Extended warranties are also available in conjunction with contract maintenance. Monitoring Gilgen has a service management system that records all service history therefore enabling swift problem diagnosis.

Gilgen Door Systems UK Limited Halesfield 4 Telford Shropshire TF7 4AP Tel: 0870 000 5252 Fax: 0870 000 5253 www.gilgendoorsystems.co.uk info@gilgendoorsystems.co.uk National Sales: 0800 3166994 National maintenance and 24hr emergency repair: 0870 000 2424 01.01.00/2011.12