EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

Similar documents
EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

EarthLinked Freeze Protection Kit Model FP-1872 Installation Manual

EarthLinked SD(A) Series

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

EarthLinked STORAGE WATER HEATER / HYDRONIC BUFFER TANK MODELS GSTE-60, GSTE-80 & GSTE-119

AVS Air Handlers Installation Manual for Classic SC, SD, and SDH

EarthLinked AVN Series Air Handlers Installation Manual

EarthLinked AFN Series Air Handlers Installation Manual

EarthLinked Model DSH-1872 Desuperheater Kit

Heat Recovery Module Installation Manual for

AVS Air Handlers Prime PSC, PSD, PSDH and Classic SC, SD, and SDH

Prime Series PSDH Geothermal Heating and Cooling System

Classic Series SC Geothermal Heating and Cooling System

Classic Series SD Geothermal Heating and Cooling System

Prime Series PSDH Geothermal Heating and Cooling System

Prime Series PSC Geothermal Heating and Cooling System

EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Installation Manual BCS2000/3000

Installation Manual BCS 1000/1500

EARTHLINKED GEOTHERMAL RENEWABLE ENERGY SYSTEMS MAINTENANCE GUIDE

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Operation and Maintenance Manual

MASS. MARITIME ACADEMY

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Installation Instructions

R.A.S.E.R.S System. Installation Guide

WineZone Ceiling Mount Ductless Split 15

MAC N-407 Air-Cooled Chiller

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

MACH N-407 Heat Pump Air-Cooled Chiller

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Temperature Control Kit Model HHK/CWK-1872

R4H4. Product Specifications

INSTALLATION AND OPERATING INSTRUCTIONS

R4H4. Product Specifications

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

MAC-120HE-03 Air-Cooled Chiller

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation Instructions

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

RCM Refrigerant Module

Condensing Unit Installation and Operating Instructions

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Commercial High-Efficiency Condensing Units

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS INSTALLATION INSTRUCTION MODELS H*DE018 THRU H*DE060 NOMENCLATURE GENERAL LIMITATIONS INSPECTION

R Series Cooling Modules

YCIV Hz & Hz

HVAC Service Technicians Training Center

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

R Series Cooling Modules

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042

Installation Instructions

Condensing Unit Installation and Operating Instructions

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

AHG**-0B Series Hydronic Air Handling Units

WCH5**4. Product Specifications

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

CWA4 Chilled & Hot Water Fan Coil

N4H4. Product Specifications

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Two-Stage Split Geothermal Heat Pump Installation & Operating Instructions Model: (RT-SE*)

Installation Instructions

PLATINUM SPLIT TECHNICIAN S MANUAL PS The Coolest Thing In Wine Storage

PACKAGE AIR CONDITIONER

INSTALLATION AND MAINTENANCE INSTRUCTIONS 2SCU13 Series Split System Air Conditioner WARNING

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone

Commercial High-Efficiency Condensing Units

ACU Split System Air Conditioners

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

INSTRUCTIONS! DO NOT DISCARD!

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

LENNDX INSTALLATION INSTRUCTIONS. IIlIIIIIIIIIIIIIIIIIIIIIIIHI A, WARNING A, WARNING WARNING RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

S2HA, T2HA, T3HA, and

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

PACKAGED AIR COOLED Product Data Catalog

Transcription:

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 10 Antifreeze Protection 14 Electrical and Sound Data 16 230-1-60 Internal Wiring 17 230-3-60 Internal Wiring 19 Field Wiring Diagrams 21 System Start-Up 24 Evacuation/Charging 24 Final Charge 26 SW-410-QS (12/11) Copyright 2011 Earthlinked Technologies, Inc.

Disclaimer Proper installation of the EarthLinked Heating and Cooling System is essential to its reliable performance. All EarthLinked systems must be installed by an authorized, trained technician who has successfully completed the training class and passed the final examination. Installation must be made in accordance with the instructions set forth in this manual and the current EarthLinked Heating and Cooling Installation, Operation and Maintenance Manual. Failure to provide installation by an authorized, trained installer in a manner consistent with the subject manuals will void and nullify the limited warranty coverage for the system. READ THE CURRENT EarthLinked Heating and Cooling Installation, Operation and Maintenance Manual FOR COMPLETE INSTALLATION DETAILS. Earthlinked Technologies shall not be liable for any defect, unsatisfactory performance, damage or loss, whether direct or consequential, relative to the design, manufacture, construction, application or installation of the field specified components. Earthlinked Technologies, Inc. 4151 South Pipkin Road Lakeland, Florida 33811 tel. 863-701-0096 fax 863-701-7796 info@earthlinked.com www.earthlinked.com CSI # 23 80 00 SW-410-QS (12/11).

Pre-Installation Upon receipt of the equipment, carefully check the shipment against the bill of lading. Reference EarthLinked matching system component model numbers in Figure 1. Make sure all units have been received and model numbers are the same as those ordered. Air Domestic Compressor Unit 1 Handler 4 Cased Coil Hydronic Water CCS - Water Module AVS - Module -018 0018-C* 0018-C* HWM-18C DWM-1836 Auxiliary Cooling Module 3 Cathodic Earth Loop 2 Protection System -018C CPS-1830-024 0024-C* 0024-C* HWM-24C DWM-1836 ACM-1836-024C CPS-1830-030 0030-C* 0030-C* HWM-30C DWM-1836-030C CPS-1830-036 0036-C* 0036-C* HWM-36C DWM-1836-036C CPS-3642-042 0042-C* 0042-C* HWM-42C DWM-4248-042C CPS-3642-048 0048-C* 0048-C* HWM-48C DWM-4248 ACM-4272-048C CPS-4872-060 0060-C* 0060-C* HWM-60C DWM-6072-060C CPS-4872-068 0068-CV NA HWM-72C DWM-6072-072C CPS-4872 1. All series Compressor Units: SC, SD, SCW, SW Contained in each compressor package: compressor unit four L-shaped hold down brackets service valves-liquid and vapor adapters for service valves and earth loop line set product literature 2. All series Earth Loops: V1, D1, T1, V1.5, D1.5, V2, D2, D3, H1, H5 3. ACMs are for SC, SD, SCW and SW compressor units only. 4. Air Handler Model AVS-0068-CV is for VERTICAL installation only. Note: Desuperheater and all EarthLinked thermostats can be utilized throughout capacity range. Figure 1. Model Numbers SW-410-QS (12/11) Page 3

Guidelines for the general layout of the system components is shown in Figure 2. Before placing the compressor unit (outside or indoors) review the guidelines in Figure 2. Figure 2. General System Layout SW-410-QS (12/11) Page 4

Placement and Mechanical Information EarthLinked compressor units may be located outside or inside the building, following these guidelines. OUTSIDE Locate compressor unit: On a standard HVAC condensing unit pad, resting on firm, level, settled ground. Same as for INSIDE placement. See below. INSIDE Locate compressor unit: On a solid, level hard surface. If compressor unit is to be fastened, see Figure 3 for bracket installation. Where compressor unit sound and vibration will not disturb human activities. Compressor unit may be located in garage, basement, crawl space or utility room. Avoid placing compressor unit in kitchen, bedroom, family/living/dining room areas. In a condensate pan. On vibration pads. Attic installations, where necessary, must include a drip pan, anti-vibration pads and are to be suspended from the rafters with suspension isolators. For SD compressor units (which have potable domestic water connections) where the surrounding air temperature remains above 40 F. Where suggested clearance is 3 feet on both sides, top and front, for access. However, local codes and applicable regulations take precedence. Clearance from back panel to wall and minimum side clearance should be at least one foot. See Figure 4 for details. Where the total length of refrigerant line sets (from manifolds to compressor and from compressor to air handler) do not exceed 125 feet, as shown in Figure 2. Where the compressor unit is no more than 20 feet higher than the earth loop manifolds. Compressor unit may be located lower than the earth loop manifolds. See Figure 2. Figure 3. Compressor Unit Bracket Installation SW-410-QS (12/11) Page 5

Figure 4. Compressor Unit Clearance Compressor units are shipped from the factory with a low pressure nitrogen holding charge. Carefully relieve the holding charge when the compressor unit is being prepared to connect refrigerant system piping. The compressor unit package contains a service valve kit and an adapter kit. The two service valves are to be installed on the earth loop vapor and liquid connections of the compressor unit, using the adapters to right-size to the proper earth loop line set. Installation of the service valves will provide isolation of the earth loop system from the compressor unit and provide easy access to the refrigerant system. The service valve configuration provided is illustrated in Figure 4a. The ball valve stem is accessed by removing the cap. The service port is equipped with a Schrader valve insert. SW-410-QS (12/11) Page 6

Figure 4a. Service Valve Orientation Complete service valve installation instructions are contained in the Service Valve Kit Installation Manual, included with the service valves. SW-410-QS (12/11) Page 7

SW-410-QS (12/11) Page 8

Figure 5. SW Connections SW-410-QS (12/11) Page 9

Figure 6. SW Internal Flow Schematic SW-410-QS (12/11) Page 10

Figure 7. SW Piping SW-410-QS (12/11) Page 11

System Application Options Figure 8. SW Air Heating, Cooling and Domestic Hot Water by Priority Heating with DWM SW-410-QS (12/11) Page 12

Figure 9. SW Radiant Panel Hydronic Heating and Air Cooling SW-410-QS (12/11) Page 13

Figure 10. SW Radiant Panel Hydronic Heating and Air (Chilled Water) Cooling and Domestic Hot Water by Priority Heating with DWM SW-410-QS (12/11) Page 14

Antifreeze Protection When HWM hydronic water modules are applied to radiant panel hydronic heating and/or chilled water cooling systems, the water circulating system must be protected from potential damage due to freeze-up by utilizing an adequate antifreeze solution. The antifreeze protection is provided by the installer prior to the EarthLinked system start-up. Propylene-glycol antifreeze solution with an inhibitor is the type of antifreeze solution required for Earthlinked products utilized in radiant panel hydronic heating and/or chilled water cooling systems. These systems shall be freeze protected consistent with the application -specific minimum temperature, as shown in the table below. Propylene-glycol antifreeze solutions should always be in the range of 20% to 50% by volume, as indicated in the table. WATER SOLUTION MULTIPLIER FACTOR (WSMF) 18 20 x 1.03 8 30 x 1.07-7 40 x 1.11-29 50 x 1.16 Propylene Glycol Freeze Protection Table TEMPERATURE, F PROPYLENE GLYCOL, % Because addition of propylene-glycol to water changes the specific heat of water, the required flow rate of propylene-glycol solution (for the same heat transfer as water) must be increased by the water solution multiplier factor shown in the table above. Propylene-glycol can be purchased in the straight form and mixed with an inhibitor prior to filling the system, or it can be purchased as inhibited propylene-glycol. The following are examples of manufacturers for the above: Straight propylene-glycol: Chemical Specialties, Inc. (www.chemicalspec.com/spg.html) Inhibitor: Nu-Calgon Products, Ty-lon B20 (www.nucalgon.com/products) Inhibited propylene-glycol: Houghton Chemical Corp., SAFE-T-THERM, www.houghton.com/fluids/safe-t-therm/index.html) SW-410-QS (12/11) Page 15

General guidelines for introducing propylene glycol into the water circulating system follow. The manufacturer s specific instructions and industry standards always take precedence when introducing propylene-glycol to the system. Calculate the quantity of inhibited propylene-glycol (fluid) required to achieve the desired results. Introduce a sufficient quantity of water to the system and pressure check to ensure a sealed system. Drain some water from the system to provide enough volume for the calculated amount of fluid. Add the correct amount of fluid and any water needed to completely refill the system, allowing for liquid expansion due to operating temperature. Circulate the inhibited propylene-glycol antifreeze solution for at least 24 hours to ensure complete mixing. Check the liquid concentration to assure that the correct mixture is obtained. SW-410-QS (12/11) Page 16

Electrical and Sound Data Compressor Model Voltage/Phase/Hz Voltage Min. Max. LRA RLA MCA MFS Sound Pressure Level * @10 ft, db(a) -018-1C 230-1-60 207 253 58.3 15.0 18.0 30 57.0-024-1C 230-1-60 207 253 64.0 14.3 18.0 30 57.0-024-2C 230-3-60 207 253 58.0 9.3 11.0 20 60.0-024-3C 460-3-60 414 506 28.0 5.7 7.9 15 60.0-030-1C 230-1-60 207 253 77.0 15.7 19.0 30 59.0-030-2C 230-3-60 207 253 71.0 10.0 12.0 20 60.0-030-3C 460-3-60 414 506 38.0 6.3 8.0 15 60.0-030-6C 575-3-60 518 632 38.5 4.2 5.0 10 60.0-036-1C 230-1-60 207 253 112.0 20.0 25.0 40 59.0-036-2C 230-3-60 207 253 88.0 15.1 19.0 30 62.0-036-3C 460-3-60 414 506 44.0 6.6 8.0 15 62.0-036-6C 575-3-60 518 632 34.0 5.5 7.0 10 62.0-042-1C 230-1-60 207 253 117.0 24.3 30.0 45 59.0-042-2C 230-3-60 207 253 83.1 15.3 19.0 30 62.0-042-3C 460-3-60 414 506 41.0 6.9 8.0 15 62.0-042-6C 575-3-60 518 632 33.0 5.4 7.0 10 62.0-048-1C 230-1-60 207 253 134.0 27.9 34.0 50 59.0-048-2C 230-3-60 207 253 110.0 17.7 22.0 35 62.0-048-3C 460-3-60 414 506 52.0 7.9 10.0 15 62.0-048-6C 575-3-60 518 632 39.5 5.7 7.0 10 62.0-060/-068-1C 230-1-60 207 253 178.0 28.3 34.8 50 63.0-060/-068-2C 230-3-60 207 253 136.0 19.2 23.6 40 64.0-060/-068-3C 460-3-60 414 506 66.1 8.7 10.7 20 64.0-060/-068-6C 575-3-60 518 632 55.3 6.9 8.5 15 64.0 LRA = Locked Rotor Amps RLA = Rated Load Amps MCA = Minimum Circuit Ampacity MFS = Maximum Fuse or HACR Circuit Breaker Size (External) AWG = Consult NEC and Local Codes *Data Source is published Copeland Compressor Sound Power Levels converted to Sound Pressure Level in db(a) at 10 Feet, having two reflective surfaces. Effects of ETI compressor unit cabinet and components not included. Figure 11. Compressor Unit Electrical and Sound Data SW-410-QS (12/11) Page 17

Figure 12. SW Electrical Ladder Diagram (230-1-60) SW-410-QS (12/11) Page 18

Figure 13. SW Electrical Schematic (230-1-60) SW-410-QS (12/11) Page 19

Figure 14. SW Series 230-3-60 Electrical Ladder Diagram SW-410-QS (12/11) Page 20

Figure 15. SW Series 230-3-60 Electrical Schematic SW-410-QS (12/11) Page 21

Figure 16. (Part 1 of 2) SW Field Wiring Diagram SW-410-QS (12/11) Page 22

Figure 16. (Part 2 of 2) SW Field Wiring Diagram SW-410-QS (12/11) Page 23

When the SW compressor unit is connected to the ETI AVS Series variable speed air handler and the domestic water module (DWM) or the hydronic water module (HWM), as illustrated in Figures 8, 9 or 10, the system must be field wired in accordance with Figure 17, shown below. Figure 17. Special Field Wiring for SW Compressor Unit with ETI AVS Series Variable Speed Air Handler and DWM or HWM. SW-410-QS (12/11) Page 24

System Start-up Evacuation/Charging 1. SC, SD and SW Models Refer to Figure 18 and the following description: a. Seal Test Evacuation and Initial Charge 1. Carefully vent the nitrogen charge from the compressor unit. 2. After installing and nitrogen brazing the HVAC system components and compressor unit service valves, turn the Service Valves OFF and pressurize the HVAC components to 150 psig with dry nitrogen and a trace of refrigerant. Valve off the nitrogen Tank from the HVAC system components and check joints with a sensitive Electronic Leak Detector to ensure they are sealed. Check the Pressure gage after 15 minutes and verify the original pressure has not decreased. Repair any leaks and re-test as appropriate. 3. After venting the pressurized system, connect the Gage Block, Refrigerant Container and Hoses as shown in Figure 18. LP and HP valves are fully open. Both Service Valves are fully opened. 4. As illustrated in Figure 18, connect a good quality Digital Micron Gage to the Liquid Line Service Valve Access Port with an Isolation Hose/Valve. Connect a quality Vacuum Pump (at least 6 CFM capacity) to the Gage Block. 5. Connect the Refrigerant Hose from the Refrigerant Container to the Charging Port. Purge the Charging Hose of air, tighten the hose connection to the Charging Port and close the Valve on the Refrigerant Container. SW-410-QS (12/11) Page 25

6. Initiate the system evacuation. Evacuate the system down to 230 MICRONS as read on the digital micron gage. After 230 microns has been achieved, turn off the LP and HP valves and turn OFF the vacuum pump. Reading the digital micron gage, the system pressure must not exceed 280 MICRONS WITHIN 5 MINUTES. If pressure rises to greater than 280 microns, open LP and HP valves, crack the refrigerant valve and allow just enough refrigerant into the system until 20 inches of Hg vacuum is read on the LP gage. Close the refrigerant valve, and initiate the evacuation process again and until the above conditions are met. Figure 18. Typical Evacuation & Initial Charge Set-up for SC, SD, SCW andsw, Compressor Models (SC model shown). SW-410-QS (12/11) Page 26

7. Close the LP and HP valves on the gage block. Disconnect the vacuum pump and the utility hose from the gage block. Isolate/protect the Digital Micron Gage from the liquid Earth Loop Service Valve until the initial refrigerant charge is complete. 8. Open the refrigerant container valve and inject liquid refrigerant into the charging port as shown in Figure 18. 9. Charge with liquid refrigerant until 3 pounds of refrigerant per ton of system capacity, has entered the system. Liquid entering the system at the charging port goes directly to the system earth loops. It does not go to the compressor. Should the pressures equalize and prevent the intended charge from entering completely, terminate the process of initial charging. Note and document the amount of refrigerant. 10. When the initial refrigerant charge (see step 9 above) has entered the system, close the refrigerant container valve and disconnect the refrigerant hose from the charging port. Note and document the amount of refrigerant. 11. The system has now been initially charged. Disconnect the Digital Micron Gage. Final Charge It is critical to control the conditions under which the compressor unit operates while final charging the system. Final charging must be done in COOL mode. Air Handler Systems If AIR heating is provided by one of the following DX air handler systems, as listed in Figure 19, the return air to the air handler during the final charging is to be maintained in the range of 70 F to 80 F. If necessary, the air can be warmed with electric supplemental heat in the air handler. (Shunt R to W2 at the terminal block.) SW-410-QS (12/11) Page 27

Item Comp. Unit Air Htg. Hydronic Htg. Air Clg Domestic Wtr. Htg. 1. SC Yes Yes Air heating and cooling System Functions 1 Air heating and cooling, domestic hot water by field installed 2. SC Yes Yes Yes desuperheater 3. SD Yes Yes Yes 1 Air heating and cooling, domestic hot water by desuperheater 2 Air heating and cooling, domestic hot water by priority heating 4. SW Yes Yes Yes with DWM 1 Includes Desuperheater Model DESPK to supplement water heating as a by-product when system is operating in cooling mode only. 2 Priority water heating provided with separately purchased Domestic Water Module (Series DWM). Figure 19. Systems Heating with DX Air Handlers Hydronic Systems If heating is provided through a hydronic water module, HWM, as listed in Figure 20, the circulating water in the primary circuit (see Figures 21 and 22) for the hydronic system is to be maintained in the 45 F to 65 F range. Water from the main supply can be flushed through the primary circuit to maintain this water temperature range while final charging the compressor unit. Item Comp. Unit Air Htg. Hydronic Htg. Air Clg Domestic Wtr. Htg. System Functions 1. SC Yes 3 3 Radiant panel hydronic heating and air cooling (chilled water Yes handler) 2. SC Yes 3 Yes 3 1 Radiant panel hydronic heating and air cooling (chilled water Yes handler); and domestic hot water by field installed desuperheater 3. SD Yes3 Yes3 Yes1 Radiant panel hydronic heating and air cooling (chilled water handler); and domestic hot water by desuperheater 4. SW Yes 3 Yes Radiant panel hydronic heating and air cooling 5. SW Yes 3 Yes 3 2 Radiant panel hydronic heating and air cooling (chilled water Yes handler); and domestic hot water by priority heating with DWM 1 Includes Desuperheater Model DESPK to supplement water heating as a by-product when system is operating in cooling mode only. 2 Priority water heating provided with separately purchased Domestic Water Module (Series DWM). 3 Hydronic (radiant floor) water heating provided with separately purchased Series HWM Hydronic Water Module. 4 Has internal refrigerant/water heat exchanger. Requires field supplied water circulating pump. Figure 20. Systems Heating with Hydronic Heat Exchangers SW-410-QS (12/11) Page 28

Figure 21. Primary Circuit with Hydronic Water Module (HWM) Figure 22. Primary Circuit with Compressor Unit Heat Exchanger SW-410-QS (12/11) Page 29

Final charging is done in the COOL mode as follows, with the charging set up described in Figure 23: 1. Continue measuring the refrigerant charge weight as shown in Figures 23. 2. If the system is equipped with a domestic water module (DWM) in addition to the primary (air handler or hydronic) heating system, be sure the DWM switch is OFF. 3. Be sure that air entering the air handler is between 70 F and 80 F. If the system is a hydronic primary circuit, circulating water is to be maintained between 45 F and 65 F. 4. Close the HP valve. Then turn the system on in the COOL mode. The charging process is detailed in the flow chart illustrated in Figure 26. When complete, return to step 8 below. 5. Initiate final charging by opening the refrigerant container valve and the gage manifold LP valve to allow liquid refrigerant to enter the system SLOWLY. The ACC will not allow liquid refrigerant to enter the compressor. 6. Continue to add liquid refrigerant to the system until the bubbles disappear from the in-line sight glass and the flow becomes clear, indicating full liquid flow. 7. When the liquid flow in the sight glass becomes clear, turn off the refrigerant container valve. Charging is complete. 8. Document the total weight of refrigerant charge in the system. The system is now ready for adjustment of the TXV. SW-410-QS (12/11) Page 30

Figure 23. Typical Final Charge Set-up for SC, SD, SCW and SW Compressor Units (SC Model shown). 9. Next, the TXV is to be adjusted to provide 10 F to 20 F superheat while running in cooling mode. The first step is to utilize the access port and LP gage in Figure 24 to measure suction pressure. Next, apply a thermocouple at the compressor suction port as shown in Figure 24, by attaching the thermocouple lead with electrical tape, and wrapping with ½ thick insulation. SW-410-QS (12/11) Page 31

Figure 24. Superheat Measurements for SC, SD, SCW and SW Compressor Units (SC Model shown). 10. Using an accurate temperature indicator, read the suction temperature at the compressor suction port. Read the suction pressure at the access port on the LP gage. 11. Enter the Pressure-Temperature Table in Figure 25 and for the suction pressure read on the LP gage, determine the saturation temperature (evaporating temperature) from the chart, interpolating if necessary. SW-410-QS (12/11) Page 32

SATURATION TEMPERATURE ( F) SUCTION PRESSURE (psig) SATURATION TEMPERATURE ( F) SUCTION PRESSURE (psig) -20 26.1 70 199.2-15 30.8 75 216.1-10 35.9 80 234.0-5 41.5 85 253.0 0 47.5 90 273.0 5 54.1 95 294.1 10 61.2 100 316.4 15 68.8 105 339.9 20 77.1 110 364.6 25 86.0 115 390.5 30 95.5 120 417.7 35 105.7 125 446.3 40 116.6 130 476.3 45 128.3 135 507.6 50 140.8 140 540.5 55 154.1 145 574.8 60 168.2 150 610.6 65 183.2 Figure 25. Pressure-Temperature for R-410A 12. To determine the degrees of Superheat, subtract the saturation temperature determined in step 11 from the suction temperature read at the compressor suction port thermocouple. The difference in the temperatures is the superheat. (Superheat, F) = (Suction Temp., F) - (Saturation temp., F) 13. If superheat is less than 10 F, increase the superheat by adjusting the setting on the TXV in the clockwise direction. 14. If superheat is greater than 20 F, wait for the ground surrounding the earth loops to warm up. The TXV valve is factory set at MINIMUM superheat and the TXV cannot be further adjusted to decrease the superheat until the ground warms up. 15. See Figure 26 and follow the guidelines to bring the superheat into the 10 0 F to 20 0 F range. When superheat is adjusted to within this range, the system is fully operational and needs no further adjustment. 16. Check system operation in the HEAT mode. Refrigerant control is automatic. Do not attempt adjustments to the TXV control in the HEAT mode. If the refrigerant level is higher than the top sight glass on the ACC, remove refrigerant from the system until the refrigerant level in the ACC falls below the top sight glass. Document the net weight of the refrigerant charge in the system. Net weight is equal to the final refrigerant charge minus refrigerant removed from the system. Write it down on the Warranty Registration Card and inside the compressor unit on the electrical diagram, for future reference. This is the full system charge. 17. Airflow may be adjusted as necessary by accessing the AVS air handler control. Reference the Air Handler Installation Manual before making adjustments. SW-410-QS (12/11) Page 33

Figure 26. Charging and Superheat Adjustment Process SW-410-QS (12/11) Page 34