kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

Similar documents
Flexy II Product catalogue

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PRODUCT CATALOGUE ROOFTOP BALTIC

... RTU. Packaged Air to Air Heat Pump...

48/50UA-UH. Packaged Rooftop Cooling Only Units, Heat Pumps and Gas Heating Units

Energy efficiency - Multiscroll technology. Standard. Comfort Air quality and low noise level. Filtration Level. Ventilation minimum flow

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

AHU Plus. DX Air Handling Units

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Submittal Data Performance Data Electrical Data

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

30RB /30RQ

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

PACKAGED System. PACKAGED System Packaged air conditioning for retail, service and high attendance applications

Advance Split

ACTIVA SERIES ROOF TOP Air Conditioners 017/040

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

DAIKIN Air Handling Unit Modular

ULTI+ ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS

Modular Air Cooled Scroll Chillers

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

Product Release Summary

HVAC Product Overview

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

62DA,DB,DC,DD,DE,DF07-38

Modular Air-cooled Chillers

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

APPLICATION GUIDE FLEXY FX. Rooftop packaged unit with heat recovery kw FLEXY FX-AGU-1112-E. lennoxemeia.com

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

AQUASNAP JUNIOR 30RHV

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Installation Operation Maintenance

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Voyager III Rooftop Units. Voyager III. Rooftop Units RT-PRC022-E4. Cooling-only. Heat-pump. Gas-fired. Heat pump with gas-fired heating

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Aquaflair TRAC-TRAF-TRAH

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftop Close control Water source heat pumps Direct expansion

The ultimate fresh air solution.

THE ULTIMATE ROOFTOP SOLUTION

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

pyxis u pyxis ua NEW rcgroupairconditioning

ELFOEnergy Duct Inverter

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

CRIMSON & CRIMSON MAX

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

COOLflow 4E PRODUCT RANGE

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

RoofPak Applied Rooftop Systems

air systems Roomtop RTC-RTH 15 to 30 - L

RGE 13 A T - 1 A

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

48 50 UH UA PACKAGED ROOFTOP

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Hi - Wall Split Systems 12K - 18K - 24K

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

THE CARRIER COMFORT LINE

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

pyxis pyxisa NEW rcgroupairconditioning

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

TCD-TCH. Self-contained rooftop unit. VOYAGER I and II range TCD: Downflow discharge and intake TCH: Horizontal discharge and intake

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Transcription:

Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution ost effective package for fast and easy installation Multiple heating options available Fresh air control and free cooling/heating management Wide choice of communication interfaces Heat recovery module to decrease energy consumption General description Rooftop solution is the most cost effective package solution for high efficiency comfort air conditioning of single volume buildings. First class efficiency system thanks to multiscroll compressor technology associated with chlorine free R40 refrigerant. The rooftop unit product line is Lennox most innovative equipment for commercial applications. dvanced LIMTI controller, designed to improve energy efficiency and reliability. This controller integrates master slave capability and a wide choice of communication interfaces. ost effective package solution for fast and easy installation. Low weight construction for easy lifting in all site configurations. Many standard airflow configurations and wide range of adjustable roof curbs to suit all type of building designs. Multiple auxiliary heating options available, with intelligent control to allow the selection of the most efficient way to generate heating based on the outside temperature and/or energy costs. Fresh air control and free cooling/heating management for healthy and comfortable environments. Heat recovery solutions on exhaust air through an enthalpic wheel. The units are available with the following versions: > Heat pump > Multiple fuels units combine heat pump with gas fired heating Main components R40 scroll compressors EN 6004- electrical cabinet with circuit breaker protection, numbered wires and connectors Fire proof M0 insulation Wide choice of air filtration and pre-filtration up to F7 Removable and washable drain pan and siphon. orrosion resistant casing (galvanized steel or aluminum) with stainless steel fixings. Voltage 400V/3Ph/50Hz High efficiency E fan motor LIMTI controller Full text fault display and history. Many settings and readings available for customization and diagnostic. dvanced control features: advanced compressor management; dynamic defrost; intelligent fresh air management; automatic summer/winter change, variable speed drive fan management with airflow measurement Extended communication capability : Master/Slave, Modus and net RS485 or TP-IP, LonWorks, ompatible with Lennox monitoring and supervision solutions. G5-E_V 37

FLEXIR High efficiency rooftop for long lasting energy saving High efficiency refrigeration circuit xial fans with swept blades orrosion resistant aluminium casing dvanced LIMTI controller edrive E fans Gas burner Intelligent fresh air and free cooling/heating Guarantied sustainable performance with edrive Variable speed drive irflow reduction during part load operation and dead zone Very high efficiency «E» technology fan motor Power factor correction to reduce current Soft starter to limit inrush current duting start-up Easy airflow adjustement during commissioning Easy communication and service with eflow airflow management Direct drive transmission No friction means better efficiency even at full speed No efficiency reduction due to loose or worn-out belts Maintenance free fan dvanced refrigeration circuit Multiscroll compressor technology for best load performance year round R40 refrigerant for best efficiency Electronic expansion valves for optimum control in all conditions Optimised heat exchanger surface area to boost system energy «Multiscroll» compressor technology allows energy consumption reduction when compared to «Inverter» solutions. Net EER 4,5 4,0 3,5 3,0,5,0 MultiScroll + edrive TM Multi-Scroll Inverter Scroll Single Scroll,5 0 0 30 40 50 60 70 80 90 00 apacity load in % of nominal 38 G5-E_V

General data FLEXIR 085 00 0 50 70 00 30 ooling mode - F Net cooling capacity () Net absorbed power () Net EER () Eurovent energy efficiency class ooling mode Heating mode - FH Net heating capacity () Net absorbed power () Net OP () Eurovent energy efficiency class Heating mode uxiliary heating (ll FLEXIR) kw kw 84, 98,3 5, 43,4 58,8 84,8 3,0 6,0 33,7 40,4 5,7 59,9 64,0 78,6 3,4,9,85,77,65,89,84 80,3 97,7 3, 37,6 6,4 9, 3,6 3,7 9,5 37,6 40,7 49,9 55,7 75,0 3,39 3,3 3,0 3,38 3,9 3,43 3,09 Gas heating capacity kw - S/H (4) Electric heater capacity kw - S/M/H (4) Hot water coil capacity (0 in/water 90-70 ) Refrigerant circuit (ll FLEXIR) kw - S/H (4) 55,/0,4 0,4/65,6 65,6/0,8 30/54/7 45/7/08 7/08/6 /75 4/97 30/09 40/5 49/7 77/96 99/33 Number of compressors/number of circuits Refrigerant charge per circuit kg Max. outdoor temp. at indoor 7 D/ 9 W (3) Ventilation (ll FLEXIR) / 3/ 4/ 9, + 9, 9, + 9, 9, + 9, 5 + 4,5 46 5, + 4,5 8,5 + 8,5 9,8 + 9,8 Nominal airflow rate Minimum airflow rate Maximum airflow rate coustic (external static pressure 50 Pa) Outdoor sound power (Lw) Standard unit () Outdoor sound power (Lw) Low noise unit (5) Indoor blower outlet sound power (Lw) Standard unit (6) m 3 /h d() 5000 8500 0500 6000 30000 35000 39000 000 4000 5000 8000 000 4000 7000 3000 3000 3000 35000 35000 43000 43000 80, 88,5 89, 86,8 85,9 84,9 85,4 75 8 86 8 8 79 8 86,3 8,7 97,6 9,4 95, 9,3 9 () ll data at EUROVENT conditions ooling : 35 D - 7 D 47% / 9 W Heating : 7 D - 0 60% / 5 W) Nominal airflow rate, nominal external static pressure, 400 V/3 Ph/50 Hz) () Net EER = Net cooling capacity/ Total absorbed power Net OP = Net heating capacity/ Total absorbed power (3) The cooling and heating operating limits are given for steady state running condition with noted temperature condition (4) S = Standard heat M = Medium heat H = High heat (5) t 47% partial load (6) t partial load, and depending on models, possibility to reduce sound power level between 5 and 0 da. FLEXIR is part of RT Eurovent ertification Program up to 00 kw heck ongoing validity of certificate : eurovent-certification.com certiflash.com G5-E_V 39

Dimensions and weights FLEXIR F OX G OX H OX D FLEXIR 085 00 0 50 70 00 30 View F F F G G H H 45 45 60 mm 335 4360 566 750 885 35 D 360 456 60 Weight of standard units asic unit - F kg 966 055 054 454 550 07 43 Weight of gas unit asic unit Standard Heat kg 03 7 08 576 68 57 37 asic unit High Heat kg 083 87 78 599 704 97 4 D D Roofcurb dimensions and weights NON DJUSTLE, NON SSEMLED ROOFUR DJUSTLE ROOFUR MULTIDIRETIONL ROOFUR FLEXIR 085 00 0 50 70 00 30 059 059 059 Non-adjustable, non mm 77 3466 4066 assembled roofcurb 40 40 45 ssembled adjustable roofcurb Multidirectional roofcurb Vertical return roofcurb Horizontal return roofcurb 59 59 59 mm 87 3567 467 400 400 45 54 54 54 mm 745 344 4067 840 40 340 56 56 56 mm 3005 3496 3493 0 0 0 083 083 083 mm 805 393 393 0 0 0 ENTRIFUGL RETURN ROOFUR (vertical and horizontal) 40 G5-E_V

Principle sketches FLEXIR (vertical flow) MULTIDIRETIONL ROOFUR 3 3 4 EXHUST RETURN ROOFUR (vertical flow) ENERGY REOVERY MODULE 65 6 Fresh air Return air Exhaust air Supply air 3 4 5 6 Supply fan Return air damper Exhaust damper Multidirectional roofcurb Heat recovery exchanger Return/Exhaust fan G5-E_V 4

IR OOLED ROOFTOP PKGED UNIT LTI & FLEXIR Standard features Energy efficiency and comfort edrive : edrive is a standard feature of Lennox LTI & FLEXIR units. It is a variable speed, direct transmission ventilation system that saves energy and reduces maintenance costs. dvanced multiscroll refrigeration circuit : Lennox rooftops feature the high efficiency, environmentally friendly refrigeration circuits with multiscroll R40 compressors, optimized heat exchange area and electronic expansion valves. ir sock control : Soft start control allows the air socks to be progressively filled with air on start up. This feature is provided as standard on LTI and FLEXIR thanks to edrive. Free cooling/heating : Thermodynamic cooling or heating can be replaced by free-cooling/heating when outdoor temperature are favorable (below/above the building set point), saving up to 30% on annual energy consumption. ccurate percentage of fresh air : On all Lennox rooftops units, the damper position is periodically recalibrated to ensure the real percentage of fresh air is introduced into the building (patent 03 5066). This feature ensures a better O management while saving energy by reducing the amount of cooling or heating to treat the extra fresh air. M0 fire proof insulation : ll Lennox rooftops feature M0 rock or glass wool insulation as standard. The insulation will not burn and will not generate smoke in case of fire. LIMTI Description LIMTI general description This microprocessor based control, LIMTI equips the Lennox rooftop range. It is designed to provide best energy efficiency throughout the unit life cycle while ensuring reliable and consistent operation. LIMTI integrates innovative PID control that will guaranty better temperature accuracy, while saving energy. Main functions are : ompressor running time optimization Scheduling capability. ontrol of multiple rooftops units. LIMTI main options dvanced control pack : Thanks to specifi c algorithm and sensors, this pack allows enthalpy control of freecooling. Service display : This plug and play service display and controller allows service personal to set up to read and modify all unit parameters: Unit settings, operating time and number of compressor starts, low and high pressure reading, airflow rate of supply fan, and read the history of last 3 faults... omfort display : This is a remote controller for non-technical customer. It was designed to aesthetically fit in the room and be very easy to use. With this display the customer can modify temperature set points. Dry control board : It provides various logical dry contact inputs to be able to take over the control of the unit. ommunication interfaces and supervision : LIMTI offers different functionalities and communications options : master slaved, GT interfaces through Modbus, Lonworks and acnet, and DLINK II, the fully integrated Lennox solution to control up to 6 units on the same site. 4 G5-E_V

Options uxiliary heating uxiliary electric heater : Staged or modulating, available in different sizes (small, medium, high). uxiliary electric pre-heater : Located before the main thermodynamic coil, designed to allow heat pump operation with low mixed air temperature (low outdoor temperature with units running with a high fresh air rate in winter). Fully modulating. Hot water coil : and rows hot water coils offer fully modulating control through the use of a 3 way valve. Frost protection through thermostat controlled valve. 9% high efficiency atmosheric gas burner : This high efficiency gas burner offers improved space comfort through stages or by modulation. Energy recovery Energy recovery on exhaust air : This option is designed to recover energy in the exhaust air to pre heat or pre cool the fresh air and save energy. Lennox heat recovery modules are built around EUROVENT certified heat exchangers and are fully controlled by the LIMTI. On LTI range, an additional thermodynamic circuit may be available to recover calories on exhaust air. Energy meter : This option measures and displays energy consumption and displays the absorbed power, power factor, intensity and tension values of each phase. onnected to the time counter of the LIMTI, it also provides these information for each heating or cooling period, as well as periods when the ventilation is activated. Indoor air quality Indoor air quality sensor : This feature gives the possibility to match minimum fresh air requirements with occupancy. It measures O levels and adjusts fresh airflow rate accordingly. Gravity exhaust damper : Gravity exhaust damper relieves the pressure when outside air is being introduced in the system. xial power exhaust fan : Provides exhaust air pressure relief when high levels of fresh air are being introduced in the system. entrifugal return roofcurb : Where system balancing is critical, the fan is able to exhaust up to the nominal airflow rate of the unit and improves energy and maintenance cost. Refillable G4 filter : Instead of replacing the whole filter frame, only the media has to be changed. It s a good cost saving solution. G4/F7 panel filters : dding a G4 pre-filter before the F7 filter reduces excessive replacement of F7 filters. Double skin : This feature prevents bacteria development on porous surface and allows an easy cleaning of the panel. It also prevents insulation particles to be carried away in the air stream. nalog dirty filter sensor : differential pressure sensor measures the pressure drop across the filters and coil to allow preventive filter change, thus reducing energy consumption and improving air quality. Hot water coil Electric heater Gas burner G5-E_V 43