SP-1000X. Panic Device Power Controller Installation Guide. Rev

Similar documents
RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Series. Access Power Controllers. Installation Guide

Installation Guide for models:

Installation Guide for models:

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Access Power Controllers with Power Supplies

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

AL600ULX Series. Power Supply/Charger. Installation Guide

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Rack Mount Series Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

MODEL B2 INSTALLATION MANUAL

MANUAL RESET ALARM RELEASE

EVO192 v3.0 Fire and Burglary What s New

MANUAL RESET ALARM RELEASE BOX

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Remote Chexit Module (RCM) System. General Information

RELEASE DEVICE CONTROLS

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Model 17A00 Expansion Enclosure

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

TECHNICAL DATA OBSOLETE

MANUAL RESET ALARM RELEASE

Public Safety DAS Annunciator Panel

Remote NAC Power Supply D7038

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

DS160/161 Request To Exit PIR sensors Installation Instructions

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

DE5300 Delayed Egress System. General Information

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

Booster Power Supply Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Specification/ Data Sheet

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

MR-2602 Two Zone Fire Alarm Control Panel

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Installation, Operating and Maintenance Manual

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

DS160/DS161 Request To Exit PIR sensors Installation Instructions

/9308 External Battery Chargers Installation Instructions

PSN-1000 & PSN 1000(E) Installation Manual

INSTALLATIONN GUIDE & OPERATION MANUAL

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

July 14, 1999 DF C-100.

FPC-02 Series. Installation and Operating manual

KT-100 Door Controller

more than just power! Altronix is the professional security industry s leading manufacturer

/ How To Order

HARDwired Installation/ Owner s Manual

RMS/RPX Reader. User Manual

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

Transcription:

TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213

Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current surge panic hardware locking devices demand. Each lock output has an adjustable relock delay timer. It will control a pair of doors simultaneously or independently control two individual doors. It has a follower relay for each output to trigger external relays, ADA push plate switches, etc. Delayed follower relays control automatic door operators for doors that are always locked or for doors that are unlocked during the business day. In addition, two un-switched auxiliary voltage outputs are provided for powering card readers, keypads, REX PIRs, electronic timers, relays, etc. A configurable FACP interface will either provide power or remove power to the lock outputs when activated. LED status indicators are provided to monitor AC power, FACP status and for lock output wiring supervision. Intelligent logic provides protection against accidental shorting of lock outputs. Agency Approval: UL 294 - Access Control Unit Power Supply. ULC-S319 - Access Control Unit Power Supply. Class 1. CSFM - California State Fire Marshal Approved. Input: Input 115VAC 60Hz, 6.3 amp. Two (2) NO trigger inputs. Input fuse rating: 6.3 amp. Outputs: Power options: - Two (2) 20VDC to 26.4VDC individually controlled lock outputs for applications with battery back-up. 24VDC for applications without battery back-up (US applications only). Current rating 15 amp for 300ms, 0.75 amp continuous supply current. - 5V holding voltage with 20VDC to 26.4VDC initial 100ms pulse. Maximum total 5V holding current of both outputs is 0.74 amp. One (1) 20VDC to 26.4VDC for applications with battery back-up, 24VDC for applications in US not requiring battery back-up. Auxiliary output rated @ 0.75 amp continuous supply current (Not affected by FACP trigger). One (1) 12VDC filtered regulated auxiliary output rated @ 0.5 amp (Not affected by FACP trigger). Two (2) follower form A SPST relay outputs rated @ 0.6 amp/28vdc. Relays energize while input is closed. Two (2) delayed follower Normally Open relay outputs rated @ 0.6 amp/28vdc. Delay time is selectable 0.5 seconds or 1 second. Energized duration is 1 second. Trouble relay output indicating low DC output voltage. Specifications: Battery Backup: Battery fuse rating: 25A/32V. Maximum charge current 650mA. Built-in charger for sealed lead acid or gel type batteries. Automatic switch over to stand-by battery when AC fails. When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes. Visual Indicators: Green AC Power LED indicates 115VAC present. Red trigger input LEDs indicate panic device status /trouble (activated, short or open circuit). Green Fire Alarm Interface (FAI) LED indicates FACP disconnect is activated. Red Battery LED indicates low battery during AC failure and manual test. Green AC LED indicates loss of AC trouble (not active during manual test sequence). Fire Alarm Interface: Normally Closed FACP trigger input. Configurable Fire Alarm Disconnect options: - Removes power to outputs and disables delayed follower relays. - Connects power to lock outputs and enables delayed follower relays. Additional Features: Manual testing to allow to tests battery conditions. Adjustable panic release from 1 sec. to 30 secs. Note: Follower and Delay relay turns off when the potentiometer selected time elapses after release of the input trigger. Cam lock included. Enclosure Dimensions (H x W x D approx.): 13 x 12.5 x 3.25 (342.9mm x 330.2mm x 82.55mm) SP-1000X Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. For Canadian installations - shielded wiring of appropriate gauge must be used. Unit is to be serviced by authorized personnel and de-energized prior to opening. 1. Mount unit in desired location within protected premises (Maximum Wiring Distance, pg. 6). Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8). Secure cabinet to earth ground. 2. Hard wire unit: Connect unswitched AC power (115VAC 60Hz) to terminals marked [L, N]. Use 14 AWG or larger for all power connections. Secure green wire lead to earth ground. Keep power-limited wiring separate from non power-limited wiring (115VAC 60Hz Input, Battery Wires). Minimum 0.25 spacing must be provided (Fig. 4, pg. 8). Connect earth ground to a ground lug or ground lead. Do not connect to a receptacle controlled by a switch. Unit is intended for permanent connection using metal enclosed system. A fixed product shall be connected with one of the applicable wiring systems in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations. - 2 - SP-1000X

Note: SP-1000X is intended to be permanently connected. To install 3-wire line cord with integral strain relief (supplied) refer to page 9. 3. Measure aux. output voltage before connecting devices. This helps avoid potential damage. 4. For ULC applications, all interconnecting devices must be ULC Listed. Connect panic hardware device # 1 to terminals marked [+ OUT1 -- ], connect panic hardware device # 2 to terminals marked [+ OUT2 -- ] (Fig. 1, pg. 5). Be sure to observe polarity. For devices requiring 24VDC holding voltage, set dip switch [SW2] to OFF, for 5VDC holding voltage, set dip switch [SW2] to ON (Fig. 3b, pg. 7). Maximum wire resistance for each output is 0.25 ohm (see wiring gauge and distance chart, pg. 6). The panic hardware device operating voltage specifications must cover 20VDC to 26.4VDC range. Note: Refer to compatible panic hardware device list, pg. 5. 5. Set lock output release time by adjusting [OUT1] and [OUT2] potentiometers. Turn potentiometer clockwise to increase time or counter-clockwise to decrease time. Timing range is 300ms. to 30 seconds, (unit is factory set @ 300ms.) (Fig. 3a, pg. 7). Note: When external control of door unlock time is desired, i.e., card reader, set time to minimum (completely counter-clockwise). 6. Connect Normally Open (NO) Dry Contacts from actuating devices such as an Access Control Panel, REX PIR, Keypad, etc. to terminals marked [, IN1] and [, IN2] (Fig. 1, pg. 5). Note: When triggering both Input 1 and Input 2 from a single actuating device, set dip switch [SW1] to ON for sequential mode (100 ohm line resistance maximum). 7. Connect auxiliary devices to be powered (Keypads, REX motion detectors, electronic timers, external relays ) to the appropriate auxiliary power output terminals. For 12VDC devices, use terminals marked [+ 12VDC -- ]. For 24VDC devices, use terminals marked [-- 24VDC +] (Fig. 1, pg. 5). Note: Operating voltage range of device should be 20VDC to 26.4VDC or wider. 8. Connect devices to be controlled to terminals marked [DELAYED1, DELAYED2] and/or [FOLLOWER1, FOLLOWER2] (Dry form A contacts are rated @ 600mA/28VDC) (Fig. 1, pg. 5). Adjust delay time using dip switch [SW3] (Fig. 3b, pg. 7) (0.5 seconds with SW3 in the OFF position, one (1) second with [SW3] in the ON position), (unit is factory set for 0.5 seconds delay). Note: For UL/ULC applications, all interconnecting devices must be UL/ULC Listed respectively. 9. To hookup the Fire Alarm Interface feature, wire the normally closed (NC) dry contact output from a Fire Alarm Control Panel to the terminals marked [FACP] and [] of SP-1000X. The FA Select dip switch [SW4] provides two (2) modes of operation (Fig. 3b, pg. 7): a) With dip switch [SW4] in the ON position, the application of a FACP trigger input (open circuit) while Input 1 and Input 2 are triggered will cause the unlocked (energized) panic hardware devices to relock (de-energize). Follower relays will release (de-energize). b) With dip switch [SW4] in the OFF position, the application of a FACP trigger input (open circuit) while Input 1 and Input 2 are not triggered will cause the locked (de-energized) panic hardware devices to unlock (energize). Follower relays will activate (energize). Delayed relays will energize momentarily. Note: With SW4 in the OFF position, the application of a FACP trigger input (open circuit) while Input 1 and Input 2 are triggered will have no affect on the operation of Output 1 or Output 2 and their corresponding Follower or Delayed relays. 10. When using stand-by batteries, they must be lead acid or gel type. 7AH batteries will provide 30 minutes of backup time. Connect two (2) 12VDC batteries wired in series to the terminals marked [+ BAT -- ]. For Access Control applications in the U.S. batteries are optional, for Canadian applications batteries are required. When batteries are not used loss of AC will result in the loss of output voltage. 11. Mount UL Listed tamper switch (Sentrol model 3012 or equivalent) at the top of the enclosure. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 3, pg. 7). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Note: Do not exceed voltage and current ratings of tamper switch. Please refer to tamper switch installation instructions. 12. Upon completion of wiring secure enclosure door with screws or cam lock (supplied). SP-1000X LED Diagnostics: LED LED Status Panic Device Power Controller Status Power - On Normal operating condition. Green (AC) Off Loss of AC. On Output 1 - Energized. INP1 - Red Slow Blink Output 1 - Open Circuit. Trigger Input 1 Rapid Blink Output 1 - Short Circuit. Off Output 1 - De-energized. SP-1000X - 3 -

INP2 - Red Trigger Input 2 FAI - Green BAT Trouble Red AC Trouble Green On Slow Blink Rapid Blink Off On Off Off On Slow Blink Off Slow blink SP-1000X LED Diagnostics (cont d): Output 2 - Energized. Output 2 - Open Circuit. Output 2 - Short Circuit. Output 2 - De-energized. FACP Input triggered (alarm condition). FACP normal (non-alarm condition). Normal condition. Manual test intiated. Battery low or missing, active during manual test or AC failure. AC normal. AC low or missing. Maintenance: Unit should be tested at least once a year for the proper operation as follows: FACP Supervision: To ensure proper connection and operation of the Fire Alarm Interface, remove wire from the terminal marked [FACP] on SP-1000X. With the dip switch [SW4] in ON positon, unlocked Panic Hardware Devices will re-lock. With dip switch [SW4] in the OFF position (Fig. 3b, pg. 7), locked Panic Hardware Devices will unlock. Output Voltage Test: Under normal load conditions the DC output voltage should be checked for proper voltage level. Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage both at battery terminal and at the board terminals marked [+ BAT -- ] to insure there is no break in the battery connection wires. Press Manual test button. The battery LED should be illuminated during the selftest (approximately 15 seconds). When the battery LED blinks slowly this indicates that the battery is low or missing and may need to be replaced or serviced. Note: Maximum charging current under discharge is 650mA. Note: Expected battery life is 5 years, however it is recommended changing batteries in 4 years or less if needed. Caution: For continuous protection against risk of electric shock and fire hazard, replace input fuse with the same type and rating: 6.3 amp/250v. Do not expose to rain or moisture; indoor use only. SP-1000X Terminal Identification: Terminal Legend Function/Description + 12VDC 12VDC Auxiliary Output @ 0.5 amp. + 24VDC 24VDC Auxiliary Output @ 0.75 amp. 20VDC to 26.4VDC for applications with battery back-up. + BAT 24VDC Stand-by Battery Connection (Two (2) 12VDC batteries wired in series). Connect 24VDC Panic Hardware Device #1 OUT 1 + (See compatibility chart for other UL Listed devices operating range of the device must cover 20VDC to 26.4VDC range 0.25 ohm maximum wiring resistance). Connect 24VDC Panic Hardware Device #2. OUT 2 + (See compatibility chart for other UL Listed devices operating range of the device must cover 20VDC to 26.4VDC range 0.25 ohm maximum wiring resistance). FACP / Normally Closed Dry Contact from Fire Alarm Control (100 ohm maximum wiring resistance). IN1 / Normally Open Trigger input controls Output 1. May be held closed for extended unlocking (100 ohm maximum wiring resistance). IN2 / Normally Open Trigger input controls Output 2. May be held closed for extended unlocking (100 ohm maximum wiring resistance). Dry form A contacts provide a 1 second momentary pulse after a preset delay. With dip switch [SW3] in the OFF Delayed 1 position, the delay is 0.5 seconds. With dip switch [SW3] in the ON position, the delay is 1 second (Fig. 3b, pg. 7). This permits the Panic Hardware Device to fully unlock before signaling auto operator to swing door. Dry form A contacts provide a 1 second momentary pulse after a preset delay. With dip switch [SW3] in the OFF Delayed 2 position, the delay is 0.5 seconds. With dip switch [SW3] in the ON position, the delay is 1 second (Fig. 3b, pg. 7). This permits the Panic Hardware Device to fully unlock before signaling auto operator to swing door. Follower 1 Dry form A contact. Energizes while output 1 is energized. Enables outside ADA switch plate to actuate auto operator while door is unlocked. De-activates outside ADA actuator while door is locked. Follower 2 Dry form A contact. Energizes while output 2 is energized. Enables outside ADA switch plate to actuate auto operator while door is unlocked. De-activates outside ADA actuator while door is locked. Indicates low DC output voltage condition. It may be caused by an AC brownout and low battery occuring Supervision simultaneously. Manual self test needs to be conducted to determine battery condition. - 4 - SP-1000X

Fig. 1 Fault C, NC dry relay contact. Open when DC output supplied by AC or Battery is normal. The contacts will close when the DC output voltage is low. Auxiliary 24VDC Device 6.3A AC 6.3A 250V 25A 25A 32V Diagnostic LEDs INP1 INP2 FAI BAT AC MAX MIN OUT1 OUT2 TIMER TIMER Manual Test Option 1-Option 2 24-5V Hold Voltage Follow-up Delay 0.5-1 sec. Fire Alarm Interface ON 1 2 3 4 FAULT C NC Delayed 2 Follower 2 Delayed 1 Follower 1 C NC +12VDC +24VDC AC Supervision Auxiliary Device Automatic Door Operator Auxiliary Device Automatic Door Operator Request to Exit PIR L G N + BAT OUT1 + OUT2 + FACP IN1 IN2 --- + 12VDC --- + 12VDC Panic Hardware Device Fire Alarm Control Panel Rechargeable Batteries Panic Hardware Device Compatible Panic Hardware Devices: Manufacturer Model Number 3600 - Concealed Vertical Rod Exit Device First Choice 3700 - Rim Latching Exit Device Kawneer EL Paneline Exit Device Note: Contact Special Projects Group, Inc. for complete list of compatible hardware. SP-1000X - 5 -

Fig. 2 AC Power LED 6.3A AC 6.3A 250V L G N Battery + 24VDC -- + BAT 25A OUT1 and OUT2 Relock delay adjustment. Used to hold OUT1 or OUT2 energized after a momentary closure across IN1 or IN2. Set for 0 seconds for output to follow input. Turn clockwise to increase time. 25A 32V Output 1 Note: For independent operation of Output 1 and 2, connect NO dry contact between IN1 and and/or IN2 and. For sequential operation of OUT1 and OUT2, set DIP switch 1 to the ON position for OPTION 2. Delayed 1 - This relay will activate after 0.5 sec. or 1 sec. Output 2 Fire Alarm Interface Connect these terminals to a normally closed dry contact that opens upon fire alarm activation. Input #1 Connect normally open dry contacts from key switch, timer, remote release or any maintained/momentary switch. Output #1 energizes while input is closed. Input #2 Connect normally open dry contacts from key switch, timer, remote release or any maintained/momentary switch. Output #2 energizes while input is closed. Delayed 2 - This relay will activate after 0.5 sec. or 1 sec. Follower 1 - This relay will activate immediately when OUTPUT 1 is energized. Follower 2 - This relay will activate immediately when OUTPUT 2 is energized. OUT1 + OUT2 + FACP IN1 IN2 1 2 3 4 Delayed 1 Follower 1 ON OUT1 OUT2 TIMER TIMER MIN MAX Option 1 - Option 2 24-5V Hold Voltage Follow-up Delay 0.5-1 sec. Fire Alarm Interface Delayed 2 Follower 2 Diagnostic LEDs AC Supervision INP1 INP2 FAI BAT AC Manual Test FAULT C NC C NC +12VDC +24VDC 24V Aux + Output -- 20VDC-26.4VDC @ 0.75A 12V Aux + Output -- 12VDC @ 0.75 amp in alarm, 0.5 in stand-by Wiring Distance Table: For 15 amp high in-rush panic devices maximum 0.25 ohm resistance of connecting wires is acceptable, see chart below for wire gauge and distances. Wire Gauge Distance 14 AWG Stranded 40 ft. 12 AWG Stranded 60 ft. 10 AWG Stranded 100 ft. - 6 - SP-1000X

1 2 3 4 Fig. 3 WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. Replace fuse with the same type and rating: Input Fuse is rated at 6.3A/250V, Battery Fuse rated at 25A/32V. Tamper Switch Earth Ground Wire Strap (from Enclosure to Door) OUT1 OUT2 TIMER TIMER Fig. 3a M MIN Option 1-Opt 6.3A AC 6.3A 250V L G N 25A + BAT 25A 32V OUT1 + OUT1 TIMER OUT2 + OUT2 TIMER MAX MIN FACP ON Manual Test Option 1-Option 2 24-5V Hold Voltage Follow-up Delay 0.5-1 sec. Fire Alarm Interface IN1 IN2 FAULT C NC Delayed 2 Follower 2 Delayed 1 Follower 1 C NC +12VDC +24VDC Power-Limited Aux. Outputs Class 2 Dry Power-Limited Outputs Class 2 Dry 115VAC Input 60Hz, 5 amp (non powerlimited) Battery Outputs (non powerlimited) Power-Limited Outputs Class 2 Dry FACP and Access Control Trigger Inputs (Power-Limited) 1 2 3 4 ON Option 1-Option 2 24-5V Hold Voltage Follow-up Delay 30-60 Fire Alarm Interface Fig. 3b Optional Rechargeable Stand-by Battery for UL294 Applications. Note: 12V batteries required for Canadian installations. Optional Rechargeable Stand-by Battery for UL294 Applications. Note: 12V batteries required Canadian installations. Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. 7AH Rechargeable batteries are the largest batteries that can fit in this enclosure. A UL Listed external battery enclosure must be used if using 12AH, 40AH or 65AH batteries. Note: Contact Special Projects Group, Inc. for a complete list of compatible hardware. SP-1000X - 7 -

NEC Power-Limited Wiring Requirements for SP-1000X Model: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power- limited applications, use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire (Fig, 4a). Fig. 4 115VAC Input 60Hz (non power -limited) Aux. Outputs (power-limited) AC Supervision (power-limited) Delayed/Follower Connections (power-limited) Battery Connections (non power-limited) FACP and Access Control Trigger Inputs (power-limited) Locking Device Connections (power-limited) Fig. 4a Incorrect Wire Handling External Jacketed Shield Correct Wire Handling Wire Insulation Solid Copper Conductors Pull back external jacketed shield approx. 1/2. - 8 - SP-1000X

Enclosure Dimensions (H x W x D) (approximate): 13 x 12.5 x 3.25 (330.2mm x 317.5mm x 82.55mm) 1.40 (36mm) 4.85 (123mm) 4.85 (123mm) 1.40 (36mm) 1.20 (31mm) 3.25 (83mm) 1.20 (31mm) 0.75 (19mm) 12.5 (318mm) 11.0 (279mm) 0.75 (19mm) 1.20 (31mm) 1.40 (36mm) 0.9375 (24mm) 1.40 (36mm) 5.10 (130mm) 5.10 (130mm) 13.0 (330mm) 5.10 (130mm) 6.5625 (167mm) 0.9375 (24mm) 3.25 (83mm) 3.25 (83mm) 3.25 (83mm) 1.0 (25mm) 1.0 (25mm) 1.0 (25mm) 10.5 (267mm) 1.0 (25mm) SP-1000X - 9 -

Notes: - 10 - SP-1000X

Notes: SP-1000X - 11 -

Notes: Special Projects Group is not responsible for any typographical errors. Product specifications are subject to change without notice. 1200 Northbrook Parkway, Suite 120, Suwanee, GA 30024, 678-417-8500 or Toll-Free: 1-888-284-4774, website: www.specialprojectsgroup.com. Made in U.S.A. IISP-1000X - REV. 120213-12 - SP-1000X