Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Similar documents
MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Innovation + Quality. Product range. Awards:

Valves, controls + systems Regudis W Dwelling stations

Brawa-Mix Thermostatic mixing valves

System illustrations 2013

Valves, controls + systems Flow, pressure and temperature balancing

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

The Meibes concept for the specialist: Easier. Quicker. More successful.

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

Installation and maintenance instructions

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

Water Piping and Pumps

Trade Product List 2013 BIOMASS ACCESSORIES

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

sustainable energy solutions

Herz York Direct Heat Interface Unit

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Smart temperature control solutions

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

TERMO Combi Cylinder TECHNICAL INFORMATION

Gas, oil and heating products. The main line products at competitive prices with even better prices on our VALUE range.

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

In cooperation with. sustainable energy solutions

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Thermostatic valve bodies

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

for an improved energy efficiency

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER ANSWER SCHEDULE

PRODUCT DATA SHEETS HEAT PUMPS

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Renewable energies. Ready-made OEM systems for manufacturers of Solar thermal systems Solid fuel boilers (pellets, split logs, wood chips ) Heat pumps

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

heat interface units A BOILER WITHOUT A FLAME

JASPI GTV & Oval thermal storage

Multipoint Technical Data

Understand and apply domestic central heating system installation and maintenance techniques

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

The sealless FLUX F 424

Series 1140 and 1141 Temperature Regulators

Thermostatic valves with radiator connection systems

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Product overview. the optimum components for every application

A. This Section includes the following domestic water piping specialties:

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

Systems for central heating

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Protection and Control of Solid Fuel Boilers

HERZ Differential Pressure Control Valve 4002

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

GESTRA. Product Overview. The optimum components for every application

Powerstock Storage Tank

Zurn Hydronics Prices Effective 1/01/06

CIRCO 6 Solar Circulation Unit

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

FHM-Cx Mixing Shunts for Floor Heating

Crown Boiler Company

Standard. thermostatic valve body without presetting

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

Saving energy comes naturally to us.

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Design and Construction Standards SECTION PLUMBING EQUIPMENT

C. B. Trading Corporation

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

REMKO HYBRID HEAT PUMPS

SECTION HYDRONIC PIPING AND SPECIALTIES

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

Components for solar heating systems

Three-way reversing valve

ThermoDual Domestic hot water charging system

Transcription:

Valves, controls + systems Innovation + Quality Stations for solar energy and solid fuel boilers Product range

Stations for solar energy and solid fuel boilers Content Page Summary Stations for solar energy 3 Regusol Stations for solar energy 4 Regusol Stations for solar energy 5 Regusol X Stations with heat exchanger for solar energy 6 Regusol X-Duo 15 and Regusol X-Duo 5 Stations with heat exchanger for solar energy 7 Regusol X-Uno 15 and Regusol X-Uno 5 Stations with heat exchanger for solar energy 8 Regusol X System examples 9 Accessories and further products for solar energy Stations for solid fuel boilers 1 Regumat RTA Stations for solid fuel boilers 11 Further products for solid fuel boilers Safety device, mixing valves, distributors, controls 1 Further boiler accessories Example: Construction of a solar installation in a one-family house Stations for solar installations and for the connection of solid fuel boilers are becoming more and more important. The reasons are not least the rising energy prices and the changing environmental consciousness of consumers. These stations are not only installed in new buildings, but also existing systems are increasingly converted. Nowadays, modern solar installations and the connection of solid fuel boilers can perfectly be coordinated with other components of the heating systems. If nearly all partial systems of the installation are supplied by the same manufacturer, everything adds up and functions perfectly. With their product ranges Regusol and Regumat RTA, Oventrop offers complete systems for the Building Services Industry. The station Regusol consists of the transmission unit, the pump circuit as well as isolating and safety devices (safety valve, check valve, flow measuring device, fill and drain ball valve etc.). For the connection of solar circuits to loading circuits via heat exchangers, Oventrop offers the system Regusol X. The station Regumat RTA consists of a boiler connection system for the connection of the heating system/storage cylinder to the solid fuel boiler. Oventrop products for solar systems and for the connection of solid fuel boilers are high quality products.

4 OV 8 1 1 1 III I berstrˆm- II einrichtung nachr stbar 4 8 1 4 8 1 OV 1 III I berstrˆmeinrichtung nachr stbar II 4 8 1 1 4 AUF L/MIN 15 1 9 7 5 8 1 ZU 1 4 8 1 1 4 8 L/MIN 15 1 9 7 5 1 1 4 bar 6 Regusol Stations for solar energy Radiator circuit MIX Surface heating circuit Hot Water Boiler II III Cold Water I Example: Integration of a solar installation into a heating system Due to the integration of all components into a pre-assembled, leak tested and heat insulated unit, installation is simplified considerably. The used materials as well as the specific order of the individual components are perfectly coordinated with the high demands on the solar system. A longlasting safe and perfect function of the system is guaranteed. The corresponding pump lengths of the units are 13 mm (standard model) or to 18 mm. Flow measuring and regulating devices for different control ranges are available. Transmission units are available with integrated deaerator. Possible airlocks arising in the system are gathered here and can manually be expelled into the atmosphere. This way, operational reliability can additionally be increased. Apart from the hydronic components, the units Regusol E-13 and Regusol EL- 13 include a complete, pre-assembled, digital control for the solar system. Advantages of the Oventrop station Regusol : - high functional efficiency due to high quality material - all components from one supplier - complete systems available - simple installation - max. short-term starting temperature 1 C - max. continuous working temperature in the supply 1 C - with insulation 3

Regusol Stations for solar energy 1 3 4 1 Transmission station Regusol-13 with safety group (pump length 13 mm) for the connection to the solar circuit DN 5 using compression fittings Regusol. Complete, pre-assembled and leak tested station with safety group and facility to connect to an expansion tank. Transmission station Regusol L-13 Same construction as transmission station Regusol-13 with additional deaerator for an effective deaeration of the heat transfer medium in the supply. 3 Pump circuit Regusol-13 with safety group, same construction as the return of the transmission station Regusol-13. Check valve integrated in ball valve. 4 Transmission station Regusol E-13 Same construction as transmission station Regusol-13 with additional electronic digital control (Prozeda or Resol). 5 Transmission station Regusol EL-13 Same construction as transmission station Regusol L-13 with additional electronic digital control (Prozeda or Resol). 6 Transmission station Regusol-18 with safety group (pump length 18 mm) for the connection to the solar circuit DN 5 using compression fittings Regusol. Complete, pre-assembled and leak tested station with safety group and facility to connect to an expansion tank. 7 Transmission station Regusol L-18 Same construction as transmission station Regusol-18 with additional deaerator for an effective deaeration of the heat transfer medium in the supply. 8 Pump circuit Regusol-18 with safety group, same construction as the return of the transmission station Regusol-18. Check valve integrated in the ball valve. 5 6 7 4 8

Regusol X Stations with heat exchanger for solar energy 1 1 Product assembly Regusol X with or without electronic control, with heat exchanger for a controlled transmission of the heat of the solar circuit (primary circuit) to a monovalent storage cylinder (secondary circuit); e.g. for existing storage cylinders without direct solar circuit connection. Complete pre-assembled and leak tested unit. A three-way valve is integrated in the supply of the secondary circuit. This also allows the conversion to a parallel running loading circuit for loading of the storage cylinder section by section and for thermal loading of another storage cylinder. The heat exchanger, a soldered panel heat exchanger, complies with the demands of the European Pressure Equipment Directive (PED). Due to turbulent flow conditions, an excellent self-cleaning effect is produced and a contamination is avoided. The solar circuit is protected against excess pressure by a safety group integrated in the heat exchanger system. The effective heat transmission depends on: - the achieved flow temperature and the flow rate of the primary circuit - the flow temperature difference between the primary and secondary circuit - the required flow temperature and the flow rate of the secondary circuit System illustration Integration of the station with heat exchanger for solar installations into a heating system with storage cylinder loading section by section. 1 Solar circuit Supply Solar circuit Return 3 Buffer tank Return 4 Buffer tank Supply I 5 Buffer tank Supply II Primary circuit connection Hot water Secondary circuit connection Cold water 5

Regusol X-Duo 15 and Regusol X-Duo 5 Stations with heat exchanger for solar energy 1 3 T K T SPupper T WT E (P) 5 6 g g b f j k n p T T SPupper K > T WTE T (P) > SPupper i T WT (P) A d h m l l N Pump solar circuit (primary circuit) n a c T SPmedium T SPlower 4 Heat exchanger TSPupper > T SPlower Pump loading circuit (secondary circuit) KW/h V. o o e Heat output registration Flow transducer M Conversion valve Collector T K T WT (P) E T WT (P) A Control Storage cylinder Temperature at collector Entry temperature of heat exchanger (primary circuit) Exit temperature of heat exchanger (primary circuit) T SPupper Upper storage cylinder temperature T Medium storage cylinder SPmedium temperature T Lower storage cylinder SPlower temperature. V Flow rate N, n Pump revolutions N: constant in primary circuit n: infinitely in secondary circuit 1 Station Regusol X-Duo 5 with or without electronic control, with heat exchanger with three-way conversion valve for second loading circuit, completely pre-assembled on carrier board. 15 KW Number of heat exchanger plates Design example: 15 KW for collector surface 3 m in solar circuit (primary circuit) 6 l/min. 76 mbar in storage cylinder circuit (secondary circuit) 5.4 l/min. 4 mbar or Station Regusol X-Duo 5 with or without electronic control, with heat exchanger, with three-way conversion valve for second loading circuit, completely pre-assembled on carrier board. 5 KW Number of heat exchanger plates 3 Design example: 5 KW for collector surface 5 mç in solar circuit (primary circuit) 1 l/min. 94 mbar in storage cylinder circuit (secondary circuit) 9 l/min. 79 mbar System illustration Arrangement of the solar circuit components (primary circuit) Regusol X-Duo : a Filling and flushing connection b Electronic flow transducer c Pump (solar circuit) d Ball valve with check valve, temperature sensor connection and thermometer inside the handle, with connection for safety group e Safety group with safety valve (6 bar), pressure gauge, fill and drain ball valve and connection for an expansion tank f Ball valve with check valve, temperature sensor connection and thermometer inside the handle with additional fill and drain valve in the elbow g Panel heat exchanger o Insulation with integrated control p Solar control with different programmable loading strategies -Target loading of upper section of the storage cylinder -Active loading section by section -Loading of complete storage cylinder 3 System illustration Arrangement of the loading circuit components (secondary circuit) Regusol X-Duo : g Panel heat exchanger h Vent plug i Pump (loading circuit) j Check valve k l Three-way conversion valve with actuator Ball valve with temperature sensor connection and thermometer inside the handle m Ball valve with temperature sensor connection, thermometer inside the handle and fill and drain valve n Safety valve (3 bar) o Insulation 4 Hydronic circuit diagram with connec-tion diagram for controller within Regusol X-Duo 5 Principal circuit diagram of the most important control functions

Regusol X-Uno 15 and Regusol X-Uno 5 Stations with heat exchanger for solar energy 1 3 g b f g m p j i n d l h h c a o o e 4 Heat exchanger Collector Storage cylinder Control 1 Station Regusol X-Uno 15 with or without electronic control, with heat exchanger for transmission of the heat of the solar circuit (primary circuit) to a loading circuit (secondary circuit), completely preassembled on carrier board. : 15 KW Number of heat exchanger plates: Design example: 15 KW for collector surface 3 m in solar circuit (primary circuit) 6 l/min. 76 mbar in storage cylinder circuit (secondary circuit) 5.4 l/min. 4 mbar or Station Regusol X-Uno 5 with or without electronic control, with heat exchanger for transmission of the heat of the solar circuit (primary circuit) to a loading circuit (secondary circuit), completely preassembled on carrier board. 5 KW Number of heat exchanger plates 3 Design example: 5 KW for collector surface 5 m in solar circuit (primary circuit) 1 l/min. 94 mbar in storage cylinder circuit (secondary circuit) 9 l/min. 79 mbar System illustration Arrangement of the solar circuit components (primary circuit) Regusol X-Uno : a Filling and flushing connection b Electronic flow transducer c Pump (solar circuit) d Ball valve with check valve, temperature sensor connection and thermometer inside the handle, with connection for safety group e Safety group with safety valve (6 bar), pressure gauge, fill and drain ball valve and connection for an expansion tank f Ball valve with check valve, temperature sensor connection and thermometer inside the handle with additional fill and drain valve in the elbow g Panel heat exchanger o Insulation with integrated control p Solar control with different programmable loading strategies - Target loading of upper section of the storage cylinder - Active loading section by section - Loading of complete storage cylinder T K T SPlower T WT E (P) T T SPlower K > T WTE T (P) > SPlower T WT (P) A n N Pump solar circuit (primary circuit) Pump loading circuit (secondary circuit) KWh V. Heat output registration Flow transducer T K T WT (P) E T WT (P) A T SPlower. V N, n Temperature at collector Entry temperature at heat exchanger (primary circuit) Exit temperature at heat exchanger (primary circuit) Lower storage cylinder temperature Flow Pump revolutions N: constant in primary circuit n: infinitely in secondary circuit 3 System illustration Arrangement of the loading circuit components (secondary circuit) Regusol X-Uno : g Panel heat exchanger h Vent plug i Pump (loading circuit) j l Check valve Ball valve with temperature sensor connection and thermometer inside the handle m Ball valve with temperature sensor connection, thermometer inside the handle and fill and drain valve n Safety valve (3 bar) o Insulation 4 Hydronic circuit diagram with connection diagram for controller within Regusol X-Uno 5 5 Principal circuit diagram of the most important control functions 7

Regusol X System examples Regusol X-Uno 15 Heat exchanger capacity 15 KW for a collector surface of max. 3 m. Primary circuit: 1 circuit for the connection of the collector fields. Secondary circuit: 1 circuit for the connection of the storage cylinder for simple operation. Regusol X-Uno 5 as Regusol X-Uno 15 but heat exchanger capacity 5 KW for a collector surface of max. 5 m. Storage cylinder connection for simple operation Regusol X-Duo 15 Heat exchanger capacity 15 KW for a collector surface of max. 3 m. Primary circuit: 1 circuit for the connection of the collector fields. Secondary circuit: circuits for the connection of the storage cylinder for loading section by section. Regusol X-Duo 5 as Regusol X-Duo 15 but heat exchanger capacity 5 KW for a collector surface of max. 5 m. Storage cylinder connection for loading section by section Regusol X-Duo 15 Regusol X-Duo 5 Primary circuit: 1 circuit for the connection of the collector fields. Secondary circuit: circuits but with loading operation for separate storage cylinders. Storage cylinder connection for loading operation with separate storage cylinders Regusol X-Uno (simple operation) Regusol X-Duo (storage cylinder with loading section by section) Regusol X-Duo (loading of storage cylinders) T5: Upper storage cylinder temperature T4: Medium storage cylinder temperature T4: Lower storage cylinder temp. (. storage cylinder) T7: Heat exchanger exit point towards T5: Upper storage cylinder temperature T5: Upper storage cylinder temp. (1. storage cylinder) storage cylinder T7: Heat exchanger exit point towards storage cylinder V1: Conversion valve for loading of storage cylinders V1: Conversion valve for loading section by section T1: Collector temperature P1: Connection pump solar circuit D1: Connection flow-meter T: Heat exchanger entry point towards collector P: Connection pump loading circuit T3: Lower storage cylinder temperature T6: Heat exchanger exit point towards collector 8

Accessories and further products for solar energy 1 3 4 1 Flow measuring and regulating device with isolation, e.g. for Regusol-13, -15 l/min. Venting circuit for replacement at existing transmission stations Regusol-13 consisting of: Ball valve with integrated check valve, thermometer and deaerator 3 Filling and flushing device Regusol Isolating ball valve with lateral connection for filling and flushing pipes to be installed at the lowest point of the solar circuit. 4 Filling pump Regusol Manual filling pump with hose connection and ball valves on suction and pressure side. 5 Temperature controller Connection thread M 3 x 1.5 with immersion sensor, is used for industrial installations, water heaters, air heaters, dishwashers, surface heating systems or similar. The control range can be limited or locked. 6 Connection set Regusol for the connection of a diaphragm expansion tank to the solar station Regusol. Consisting of steel angled wall bracket, quick coupling for diaphragm expansion tank and a corrugated pipe. 7 Thermostatic mixing valve Brawa-Mix made of bronze, for domestic water installations PN 1 up to 1 C. Control range: 35-5 C 8 Brass ball valve Optiflex with male of female thread, self-sealing, with counternut, handle with stop, with hose connection (soft seal) and cap. 5 6 7 8 9

4 8 1 OV 1 III I ãberstràm- einrichtung nachr stbar II 4 1 8 1 4 8 1 OV 1 III I ãberstràm- einrichtung nachr stbar II 4 1 8 1 3 1 4 OV 8 A AB 8 1 1 B 4 4 1 8 1 Regumat RTA Stations for solid fuel boilers The station Regumat RTA allows the connection of the heating system/storage cylinder to the solid fuel boiler. The minimum return temperature to the solid fuel boiler amounts to of 55 C and thus lies above the dew point. It prevents the formation of pitch. During start-up, the boiler flow water is short circuited directly to the boiler return via the bypass. Having reached the return temperature of 55 C, the mixing valve opens to the heat emitters. Advantages: - pre-assembled station - depending on the pump size, model Regumat RTA-13 or Regumat RTA-18 - high quality materials - insulation made of expanded polypropylene supplied with each Regumat RTA - easy installation by use of tailpipe sets - sensor integrated in the return The station consists of one isolation set (ball valves with thermometers integrated in the handle for supply and return temperature display), check valve in the supply pipe to avoid gravity circulation, circulation pump (choice of Wilo or Grundfos pump with a length of 13 or 18 mm) in the return pipe, three-way mixing valve and temperature controller with immersion sensor, control range 4-7 C. 1 Regumat RTA-13 System illustration 3 Regumat RTA-18 1 Radiator circuit Surface heating circuit Regumat M3-13 Regumat F-13 3 oventrop 4 5 Regumat RTA-18 Solid fuel boiler 1

Further products for solid fuel boilers Safety device, mixing valves, distributors, controls 1 Distributor with insulation and wall brackets for the connection of or 3 Regumat (up to 5 heating circuits). Hydronic header for the hydronic decoupling of heating and boiler circuit, with insulation. Hydronic UNIT 5 Combination of distributor and hydronic header. 3 Boiler safety device MSM-Block for closed heating systems according to DIN 4751 with a capacity up to 5 KW. The MSM-Block consists of: Brass body, pressure gauge, brass airvent with automatic shut-off, diaphragm safety valve.5 or 3 bar and insulation. Models: Female threaded connection DN 5 1 and male threaded connection 1 flat sealing. 4 Mixing valve with actuator for flow temperature control in central heating systems with circulation pump. Manual or electromotive operation (il-lustr.). Model: Three-way mixing valve, bronze fourway mixing valve DN 5 1 or DN 3 11/4. 5 Differential pressure relief device for subsequent conversion for Regumat S/M3/M4 DN 5-13/18 and DN 3-18. 1 3 4 5 11

Further boiler accessories 1 3 4 1 Pump ball valves Optibal P for a simplified installation of circulation pumps for hot water central heating systems. The pump ball valves are available with and without check valve. Temperature controller with immersion or contact senor and bronze three-way diverting or mixing valve PN 16. Especially suitable for return temperature increase of solid fuel and pellet boilers. Actuation also by use of electrothermal or electromotive actuators. 3 Valve with lead sealable cap Expa-Con with lead sealing device for the control, maintenance and possible replacement of diaphragm expansion tanks. 4 Airvents with automatic shut-off, made of brass; angle pattern model without automatic shut-off or precision airvent with automatic shut-off. 5 Bronze strainer with simple or double wire basket (for fine straining), wire basket made of stainless chromium steel. 6 Piston type spring assisted check valves and check valves. Piston type spring assisted check valves made of bronze, brass with FKM seal for horizontal and vertical installation. Bronze check valves with and without automatic deaeration, with female/male thread or with flanged connection. 7 Brass gauge cock for the use of gauges in heating systems. With gland nut and female thread, unplated or chrome plated. 8 Brass ball valve Optiflex with male or female thread, self-sealing, with counternut, handle with stop, with hose connection (soft sealing) and cap. 5 6 Further information can be found in our catalogue, our technical data sheets as well as on our homepage www.oventrop.de, product ranges 6 and 7. Subject to technical modification without notice. Printed on paper free from chlorine bleaching. F. W. OVENTROP GmbH & Co. KG Paul-Oventrop-Straße 1 D-59939 Olsberg Germany Telefon +49 () 9 6 8- Telefax +49 () 9 6 8-45 E-Mail mail@oventrop.de Internet www.oventrop.de Product range 7 PR 4-1/3/7.6/DD 7 8 OVENTROP UK LTD. Unit E - The Loddon Centre Wade Road Basinkstoke, Hamshire RG 4, 8FL Telephone ( 1 56) 33 4 41 Telefax (Sales) ( 1 56) 33 4 5 Telefax (General) ( 1 56) 47 9 7 E-Mail sales@oventrop.co.uk Internet www.oventrop.uk