Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

Similar documents
Vitronic 9 / 18 / 36. Operating instructions Notice d emploi Instrucciones de uso

Two Tier Illumifalls Patio Pond

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

ECOPLUS MAG DRIVE UTILITY PUMP INSTRUCTIONS

SolidFlo G2 Solid Handling Pumps Product Manual

23867 GAW_BioSmart_ _A5_end_ :55 Seite 2. BioSmart 5000 / /09-13

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

OWNERS GUIDE TO INSTALLATION AND OPERATION

Air Pump Up to 800 gallons

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

User Manual. Deep Cleaning Bagless Vacuum with Powerhead. Deep Clean W3000

Pressurized Filter Up to 1250 gallons

SimplyClear Pressurized Filter Product Manual

Lubi Submersible Condensate Removal Pumps

BioMaster 250/350/600 BioMaster Thermo 250/350/600

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

K 3.97 M. Specifications or visit our website: In USA call: Part No

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

OWNER S MANUAL IMPORTANT SAFETY RULES IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

READ AND SAVE THESE INSTRUCTIONS

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Model K 520 M Part No

2 000W CYCLONIC BAGLESS VACUUM

Installation manual Mini Comfort 50 S/L 07/ V EN

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

SUBMERSIBLE DIRTY WATER PUMP

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Model K 240 plus Part No

OWNER S MANUAL IMPORTANT SAFETY RULES. Deluxe Maintenance Kit IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Model K 330 M Part No

Rechargeable UV-A LED/Emergency Light

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

NORTH AMERICA. Max Max Max Unit. AR F 120V lbs. NOTE or NOTICE: Information that requires special attention.

BG8SS. 8 Inch Slow Speed Bench Grinder with LED Lights Assembly & Operating Instructions

all-rounder Mini Compact Bagless Vacuum Cleaner Cyclonic Bagless Technology Washable HEPA Filtration Compact, Lightweight & Stylish Design all-rounder

AllClear G2 Series Pressurized Filters Product Manual

Operating Instructions

Specifications: NORTH AMERICA

MLT100 Mirror Waterfall Fountain Bronze

20L Electronic Dehumidifier

Operating Instructions UniTech Perfect

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

AIR PURIFIER WITH GERMICIDAL UV LIGHT

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

QUICK PRIME INSTALLATION AND SERVICE MANUAL

GARDENA. F 3000 Art F 6000 Art F 9000 Art F Art. 7929

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

PWASH Gallon Parts Washer Assembly & Operating Instructions

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Turbo Circulating Fan (DC)

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Model K 3000 G Part No

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

R100 Oil-Less Refrigerant Recovery Unit

Next Generation Corona Discharge Installation & Operation Manual

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Model K 280 M Part No

KREEPY KRAULY PROWLER 910 ROBOTIC ABOVEGROUND POOL CLEANER

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

MEGRIND55. Electric Meat Grinder Assembly & Operating Instructions

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

LC Series - Light Commercial Pump Station Installation and Operation Manual

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

ELECTRIC POWERED PRESSURE WASHER

K Specifications. Max. Water Volume

Cord/Cordless Auto Voltage Professional Hair Clipper. Model FX811U/FXB811U BC

Electrostatic Air Purifier

PERSONAL CERAMIC HEATER

Operations and Safety Manual

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

K Specifications. Max. Water Volume

Model CWA200 Owner s Manual

Vacuum Cleaner User's manual

4-GALLON MOBILE PARTS WASHER

RSH2455G OPERATOR S MANUAL ELECTRIC QUIET CHIPPER SHREDDER

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Hisense Refrigerator

VC VC English

Ceramic Wall Heater With Remote

Up to 60 Pint Commercial Grade DEHUMIDIFIER

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

Grinding mill MISTRAL 50L (art. 650P)

6000, 8000, & 15000

SOOTHING COOL MIST AROMA DIFFUSER

Model K205 M Plus Part No

40cm Wall Fan With Pull Cord Operation

2500 Electric Blower Vac

With Remote Control. English. Model

Laminator with Hot & Cold settings

7.5IN. FOOD SLICER OWNER S MANUAL

DUST EXTRACTOR MODEL No: CDE1000

16 OUTDOOR MISTING FAN

Transcription:

Pond Pump 280 / 420 / 575 Operating instructions Notice d emploi Instrucciones de uso

REMINDER CALL 1-866-627-3435 BEFORE RETURNING TO STORE. Part Description QTY A Pump 1 B 3/4 in. ID tubing adapter with flow control 1 B. A. Information about these operating instructions Welcome to OASE Living Water. You made a great choice with the purchase of this product Pond Pump 280 / 420 / 575. Prior to operating the unit, please read the instructions of use carefully and fully familiarize yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions. Please strictly follow the enclosed instructions to ensure safe and correct handling of the product. Keep these instructions in a safe place. Please also hand over the instructions when passing the unit on to a new owner. 2

WARNINGS AND CAUTIONS SYMBOLS Symbols used in these instructions The symbols used in this operating manual have the following meanings: Risk of injury to persons due to dangerous electrical voltage. This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken. Risk of personal injury caused by a general source of danger. This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken. Important The unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers. Important information for trouble-free operation. Intended use Pond Pump 280 / 420 / 575, referred to in the following as unit, may only be used as specified in the following: For circulating and pumping normal pond water for filters and additional water features. Operation under observance of the technical data. The following restrictions apply to the unit: Do not use in swimming pools. CAUTION - this pump has been evaluated for use with water only. Never run the unit without water. Do not use for commercial or industrial purposes. Do not use in conjunction with chemicals, food products, easily flammable or explosive substances. Do not connect to the domestic water supply. Do not exceed the voltage shown on the pump. Do not remove the grounding pin from the power cord plug. Inspect the power cord for damage before installation and maintenance. Use other than that intended This unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance with these instructions or modification(s) to the unit will void the limited warranty. Questions, problems, missing parts? Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com 3

- English - Installation WARNING Risk of electric shock This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Important: Always place the unit below water level. It is recommened to place the unit horizontally on the ground ensuring its stable position. Do not lift the pump by its power cord. 1. Attach the adapter to the pump first, then connect tubing to the adapter. NOTE: Tubing is NOT INCLUDED. Tubing 1. Adapter 2. Attach the other end of the tubing to desired water feature or UV clarifier. Pump Start-up Attention The pump must never run dry. Possible consequences: The pump will be destroyed. Protective measures: Check the water level at regular intervals. Always place the unit below water level. Attention The installed temperature sensor automatically turns the pump off, if it is overloaded. The pump automatically switches on again once the motor has cooled down. Risk of accident Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC). Important: The unit switches on automatically when power connection is established. 1. 1. Switching on: Connect power plug to the socket. 2. Adjust the flow control to the preferred setting. 2. + 3. Switching off: Disconnect the power plug. 4

- English - Maintenance and cleaning Attention Dangerous electrical voltage. Possible consequences: Death or serious injuries. Protective measures: Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water. Isolate the unit before starting any work. Secure the unit to prevent unintentional switching on. WARNING This pump uses a very strong magnet to achieve superior performance. When removing the impeller assembly there will be considerable magnetic force resisting the extraction of the impeller assembly. This is normal. Likewise when replacing the impeller assembly there will be a strong magnetic force pulling the assembly into the pump to potentially cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing. Use thick gloves when replacing the impeller assembly. Cleaning the unit Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the pump when it is visibly soiled or when a drop in performance is detected. Clean the unit with warm water using a soft brush. Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the function. In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can be used. Subsequently, clean the pump thoroughly using warm water. 1. Cleaning the pump 1. Disconnect the pump from the power source. Disconnect the tubing. 2. Remove the screen and disassemble the impeller housing to expose the impeller assembly. 3. For Pond Pump 280 / 420, remove the impeller assembly by gently pulling on the impeller blades. For Pond Pump 575 remove the impeller assembly by pulling on the back round plate behind the impeller. 2. 280 / 420 575 3. 4. Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing. Check parts for damages such as cracked rotor, shaft or bearing, cracks in the magnet, and broken plastics. Replace parts if necessary. 4. 5. Reassemble in the reverse order. Questions, problems, missing parts? Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com 5

Storage/Winterization Put the unit out of operation at water temperatures below 46 F (8 C) or, at the latest, when freezing temperatures are to be expected. Thoroughly clean the unit, check for damage. Ensure that the storage place is inaccessible to children. Wear parts The impeller unit is a wear part and is excluded from the warranty. Disposal Do not dispose of this unit with domestic waste Disable the unit beforehand by cutting off the cables. Further information about the recycling of this product can be obtained from your local municipal authority. Troubleshooting Issue Cause Solution The unit is not performing its suction function Power supply not connected Impeller blocked, shaft broken Pump is not completely submerged Insufficient flow Flow control closed too far Adjust flow control Unit switches off after a short running period Screen clogged Tubing blocked Tubing kinked Excessive flow loss in the tubing due to friction Pump is not completely submerged Pump overload. The flow is automatically stopped to protect the pump. Impeller worn Excessive soiled water Impeller blocked, shaft broken Water temperature too high Connect pump power supply, check the supply lines to make sure the voltage is correct Remove the inlet screen and/or pump cover, and impeller housing to expose the impeller. Turn the impeller to ensure that it is not broken or jammed by debris. Also check to make sure that the ceramic shaft or bearings are not broken. Completely submerge pump in the water Clean Clean or replace tubing Eliminate kink, replace tubing if it is damaged Reduce tubing length to reduce frictional loss Completely submerge pump in the water Clean the pump housing and impeller assembly Reduce the ambient temperature (e.g. ensure that the specified water temperature is adhered to, avoid direct sunlight) Replace impeller assembly Clean impeller housing, bearing and impeller assembly Remove the inlet screen and/or pump cover, and impeller housing to expose the impeller. Turn the impeller to ensure that it is not broken or jammed by debris. Also check to make sure that the ceramic shaft or bearings are not broken. Maximum water temperature: +95 F (+35 C) 6

Model Model No. Rated voltage Power consumption Max. flow rate Max. head height cord length connection for hoses Dimensions Pond Pump 280 45418 0.45 A / 27 W 280 GPH 7.8 ft. 420 45419 120V / 60 Hz 0.8 A / 42 W 420 GPH 11.5 ft. 16 ft. 3/4 5.82 x 4 x 6.41 in. 575 45420 1.2 A / 68 W 575 GPH 13.5 ft. 5.82 x 4 x 6.5 in. Pond Pump Pos. 280 420 1 Pump screen Pump screen 2 Impeller housing Impeller housing 3 Shaft support Shaft support 4 Shaft Shaft 5 Impeller assembly Impeller assembly 6 O-ring O-ring 7 3/4 in. ID tubing adapter with flow control 6 7 5 3 2 3 4 1 Questions, problems, missing parts? Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com 7

Pond Pump Pos. 575 1 Pump screen 2 Impeller housing 3 Impeller assembly 5 4 4 O-ring 5 3/4 in. ID tubing adapter with flow control 2 3 1 8

OASE North America INC. www.oase-livingwater.com 46615/09-16