Power Supply Display Module PSDM. Installation and Operation Manual

Similar documents
Process Alarm Module RTA 421

Operating Instructions. For. Alarm Control Module. Model SSR 500

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

MBCE-110/230UV Flame Sensor Module

GCW SERIES Gas Cylinder Warmers

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

Q7800H Integrated Burner Control Subpanel

FireNET Plus Wiring Instructions

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Greentrol Automation, Inc.

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

CR Series Command Relays

INTRODUCTION / TABLE OF CONTENTS

MTRA-FSP Level Control Relay. Installation & Operation Manual

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

LC2200 Level Controller Installation and Maintenance Instructions

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

Installation Instructions CS3 Three Phase Solid State Relay

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

ARM SERIES Switching Relays With Priority

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Flopurge TS. Operation Manual

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TS0 Series Portable Bulb and Capillary

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

AL600ULX Series. Power Supply/Charger. Installation Guide

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

Water Detection Controllers

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

MBCE-110/230FR Flame Sensor Module

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

4-Channel Contact Closure Fiber Link Card System

6502B RF Distribution

Flostop TS D7E and A8E. Operation Manual

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

MEC 18 Mechanical Exhaust Control

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Sensor Interface Module Installation/Operation Instructions

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

MBCE-110/230FR Flame Sensor Module

RAM3 Remote Alarm Module

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

EBC 12 Modulating Fan Control

MODEL B2 INSTALLATION MANUAL

ACCURATE ELECTRONICS INC

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Model 4001 Series Single Channel Controller

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

T3/E3 Fiber Optic Line Drivers

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Installation Instructions for W2H Series Signals

MANUAL RESET ALARM RELEASE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Manual Power relay SR853

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

PARAGON Commercial Refrigeration Controls

PSN-1000 & PSN 1000(E) Installation Manual

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Commercial and Light Industrial Fire Alarm Control Panel

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

KM300 Carbon Monoxide Detection System Installation Manual

TB4000 Temperature Controller

Booster Power Supply Manual

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Transcription:

Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death or damage to equipment. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 1 of 10

Table of Contents 1. Safety Warnings... 3 2. Customer Support... 4 3. General... 4 3.1. Product Description... 4 4. Technical Specifications... 5 5. Dimensions... 6 6. Wiring Instructions... 7 6.1. Scanner Connections... 7 6.2. User Connections... 8 6.3. Wiring Diagram... 9 7. Maintenance... 10 MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 2 of 10

1. Safety Warnings IMPORTANT SAFETY INFORMATION Read All Instructions before Using The instructions provided in this manual have been prepared to serve as a general guide. It is intended for use by qualified personnel with knowledge of equipment of this type. It is not intended to cover all possible variations in equipment or to provide for specific operating problems which may arise. You are responsible for adhering to all warnings or cautions provided in this manual. In addition to any general safety measures provided in this manual, you must comply with all current national, state, local and company safety regulations at all times. Safety Symbols used in this manual comply with ISO 3864. Indicates a hazard with a high level of risk which, if not avoided will result in death or serious injury. Indicates a hazard with a medium level of risk which, if not avoided could result in death or serious injury. Indicates a hazard with a low level of risk which, if not avoided will result in minor or moderate injury. MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 3 of 10

2. Customer Support The instructions provided in the Manual have been prepared to serve as a general guide for qualified operating personnel with knowledge of the Equipment. It is not intended to cover all possible variations in equipment or to address specific operating problems which may arise. For Technical Support Call: +1.866.821.5504 3. General 3.1. Product Description The primary function of the Power Supply Display Module PSDM is to provide power for a single iscan2 flame scanner. It provides (DIN) rail mounting for easy mounting and dismounting. It has a 0.20 amp slow blow fuse conveniently located on the top of the unit for easy replacement. The PSDM is also a display module with four light emitting diode (LED) indicators on the top which indicate the following information: Power: Indicates the PSDM has power applied Scanner: Indicates the Scanner attached to the PSDM has power applied Flame: Indicates the Scanner is detecting a flame (4-20 ma signal above threshold) Fault: Indicates there is a fault with either the scanner or the PSDM The PSDM also has two outputs that are not directly available from the flame scanner: Fault Relay Contact (closes on fault) 0 10 VDC Flame Signal Output MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 4 of 10

4. Technical Specifications Part Number 2643-064-01 Electrical Classification NEMA 1 Weight 0.2 lb (0.1 Kg) Mounting Standard DIN Rail (EN 50 022) Housing Material TBS Thermoplastic, Inflammability Class V0, UL 94 Temperature Rating Humidity Power Requirement Power Output -30 C to 70 C (-22 F to 158 F) 85% Relative Humidity, Non-condensing 120 VAC ±10%, 50 60 Hz, 11 VA 24 VDC, 180 ma 4-20 Fault Contact Normally OPEN (contact closes when a 4-20mA fault occurs) 0.5 A @ 120 VAC Resistive Load 1.0 A @ 24 VDC Resistive Load Flame Relay Contact Flame Signal Output (VDC) Flame Signal Output (ma) Approvals Note: Passed through from scanner. Normally Open (i.e. contact closes when flame is detected) 0.5 A @ 120 VAC Resistive Load 1.0 A @ 24 VDC Resistive Load 0 10 VDC for Indication Only Note: Passed through from scanner. 4 20 ma for Indication Only Maximum Current Loop Resistance = 750 ohms MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 5 of 10

5. Dimensions Figure 1 - PSDM Dimensions MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 6 of 10

6. Wiring Instructions The PSDM is designed to mount in an electrical enclosure or rack. Attach the PSDM to a horizontally mounted DIN rail (EN 50 022). Mount the PSDM before connecting power or making any other wiring connections. To reduce the risk of electrical shock and injury, all electrical power from the User Connections must be disconnected or shut off before making any electrical connections. Note that terminals 7, 8, 9, & 10, as well as the power terminals 11 & 12, may have up to 120 VAC on them. 6.1. iscan2 Scanner Connections Connect the ten scanner wires to the terminals listed below. 14 Communications A 15 Communications B 16 4 20 ma Flame Signal 17 DC (-) Return 18 +24 VDC 22 File Select B (0) 23 File Select C (1) 24 Flame Relay (N.O.) 25 Flame Relay (Common) 26 Earth Ground MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 7 of 10

6.2. User Connections User connections are made to the terminals listed below. Connections to the ac power input (#11 & #12), the flame relay contacts (#9 & #10), and earth ground (#13) are required for all applications. Use the other connections as required for the specific application and scanner. 1 Communications A 2 Communications B 3 4 20 ma Flame Signal See Wiring Notes #2 4 DC Return 5 File Select B (0) 6 File Select C (1) 7 Fault Relay (N.C.) 8 Fault Relay (Common) 9 Flame Relay (N.O.) 10 Flame Relay (Common) 11 120 VAC Hot (L1) 12 120 VAC Neutral (L2) 13 Earth Ground 19 DC Return 20 DC Return 21 0 10 VDC Flame Signal MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 8 of 10

6.3. Wiring Diagram Wiring Notes: 1. Scanner wire colors shown are for the base model and the fiber optic model scanners. The hazardous location model scanner has numbered black wires. 2. The PSDM ships with a jumper between terminals 3 & 4. This jumper completes the current output loop allowing the Scanner Power LED, Flame LED, Fault LED and, Fault Relay to work properly. If the 4 20 ma output is to be used, then remove the jumper and connect the 4 20 ma loops to terminals 3 & 4. 3. Use the earth ground (terminal #13) to provide a connection between the PSDM and the enclosure in which the PSDM is mounted. Make sure the enclosure is properly grounded to earth ground. MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 9 of 10

7. Maintenance The only replaceable part is a 0.2 amp slow blow fuse located on the top of the unit. To reduce the risk of fire, replace the fuse with one of the same type and rating. MNL-PSDM REV 13JAN14 INSTALLATION & OPERATION MANUAL Page 10 of 10