National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

Similar documents
COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

COMFORT PACK PACKAGED THRU-THE-WALL AIR CONDITIONER WITH GAS HEAT USER'S INFORMATION MANUAL

Installation, Operation and Maintenance Manual

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

USER S INFORMATION MANUAL (2,4)SG13B

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

HWC8 V-Series TM Models

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL

Bosch 80% AFUE Gas Furnace BGS80 Model

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

User s Information Manual

*p * HWC4 Model THRU-THE-WALL UNIT INSTALLATION INSTRUCTIONS WARNING WARNING WARNING WARNING CAUTION CAUTION TABLE OF CONTENTS

Service Guide. Service Guide NATIONAL COMFORT PRODUCTS GAS & ELECTRIC MODELS. 2nd Edition

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL

Fig. 1 - Unit PGD4, PGS4, WPG4

Operator: Save these instructions for future use!

User s Information Manual

User s Information Manual

User s Information Manual

BGH Series Hot Surface Ignition Control

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Elite. User s Information Manual. Elite and Elite VWH* All Models

User s Information Manual

Owner s Information Manual

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Packaged Gas/Electric

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

USER S INFORMATION MANUAL

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

Operator: Save these instructions for future use!

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

STELLAR 2000 SINGLE PACKAGE AIR CONDITIONERS GAS/ELECTRIC, AIR-COOLED INSTALLATION INSTRUCTION

ML180UH SERIES GAS FURNACE WARNING WARNING

Universal Fire Tube Boiler Wall Mount Models

WARNING FIRE OR EXPLOSION HAZARD.

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

UDSA Gas fired Balanced flue / Fan assisted flue Unit Heater INSTRUCTION DOCUMENT. APPLIES FOR: Installation/Commissioning/Servicing

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

ProLine XE Combi Boiler

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

Residential Gas Hybrid Water Heater

EL195DFE SERIES GAS FURNACE WARNING

This document was created with FrameMaker 4.0.4

User s Information Manual

WARNING FIRE OR EXPLOSION HAZARD.

USER S INFORMATION MANUAL

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

USER S INFORMATION MANUAL SLP98UHV SERIES

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

8+* Bulletin No November 1997

EL195UHE SERIES GAS FURNACE WARNING WARNING

Tankless Water Heater

Operator: Save these instructions for future use!

EL195UH SERIES GAS FURNACE WARNING

GOLD. User s Information Manual. Water Boiler Series 4

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

User s Information Manual

50A Integrated Furnace Control

Technical Manual MAY 2008 Edition

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

USER'S MANUAL PGE Single Package Rooftop

MC Series Gas-Fired Heating Appliance

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

MERIT SERIES Downflow

EL296UHV SERIES GAS FURNACE WARNING WARNING

UDSA-4. Gas fired Balanced flue / Fan assisted flue unit heater INSTALLATION COMMISSIONING SERVICING

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Operator: Save these instructions for future use!

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS G60UH(X) Series

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

24 VAC SYSTEM CONTROL KIT

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

! WARNING: FIRE OR EXPLOSION HAZARD

Operator: Save these instructions for future use!

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

G61MPV SERIES GAS FURNACE WARNING

User s Information Manual Models:

Using it in an enclosed space can kill you.

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Stone Hearth Pizza Dome Oven

HIGH-EFFICIENCY UPFLOW FURNACE INSTALLER'S INFORMATION MANUAL

Transcription:

National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 639-1674 14299575-10/29/2014

NOTE: These installation and maintenance instructions should be left with the unit for future reference. INSTALLATION: This unit must be installed in accordance with all applicable codes. This unit is not to be used for temporary heating of buildings or structures under construction. FOR MAXIMUM PERFORMANCE, IT IS IMPERATIVE THAT THE COOLING CHASSIS AIR DIVIDER BE SEALED TO THE CABINET AIR SEAL. ANY LEAKAGE WILL ALLOW OUTSIDE UNCONDITIONED AIR TO INFILTRATE AND MIX WITH THE CONDITIONED AIR.THIS CONDITION WILL DEGRADATE UNIT PERFORMANCE. ALL UNITS SHOULD BE INSPECTED FOR THIS CONDITION, AS DURING TRANSPORTATION AND INSTALLATION THE SEALS CAN BE DISTURBED. IF REQUIRED, A LIGHT BEAD OF CAULKING IS RECOMMENDED TO SEAL THE CHASSIS, TO THE AIR SEAL TO ELIMINATE LEAKAGE.

National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 244-9579 COMFORT PACK - GAS FURNACE INSTRUCTIONS The gas furnace comes completely assembled, wired, mounted, and factory tested inside the Comfort Pack cabinet. The furnace includes an integral venting system that does not require any field modification or additions. The control system includes a control board with cooling relay, combination gas valve, directspark ignition electrode, flame sensor, blocked vent switch, flame rollout sensor, and high temperature limit. The rating plate indicates whether the furnace is equipped and configured for natural or L.P. gas. The furnace includes a condensate disposal system. THE GAS FURNACES ARE CATEGORY III AND ARE IDENTIFIED AS FOLLOWS: Part Numbers Input (Mbh) 14208309/HS038 38 14208308/HS051 51 14208303/HS064 64 INQUIRIES AND PARTS ORDERS SHOULD BE DIRECTED TO: National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 Phone: (215) 244-1400 (800) 523-7138 Fax: (215) 639-1674 The installer shall provide approved gas piping to the furnace including an external manual shutoff valve with 1/8 NPT plugged tapping for test gauge*, external drip leg and external ground joint union. These components and any other requirements shall conform to local building codes. Care must be exercised in locating the unit so that hot flue gas from the furnace conforms to local codes for proximities to public walkways, gas meters, intake vents, etc. In the absence of local codes, the installation must conform with the ANSI Z223.1, National Fuel Gas Code, and/or CAN/CGA-B149, Installation Code. THE FOLLOWING REGULATIONS APPLY TO THE FURNACE INSTALLATION: 1. The furnace is NOT to be used for temporary heating of buildings or structures under construction. 2. General Installation The furnace and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSI (3.5 KPA). The furnace must be isolated from the gas supply piping system by closing the equipment shut-off valve during any pressure testing of the gas supply 3. 4. 5. 6. 7. 8. 9. piping system at test pressures equal to or less than 1/2 PSI (3.5KPA). If the furnace is installed in a residential garage, it must be installed so the burner and the ignition source are located not less than 18 inches (457 mm) above the floor and the furnace must be located or protected to avoid physical damage by vehicles. Provisions for adequate combustion and ventilation air in accordance with section 5.3, air for combustion and ventilation, of the National Fuel Gas Code, ANSI Z223.1, or sections 7.2, 7.3, or 7.4 of CAN/CGA-B149, installation codes, or applicable provisions of the local building codes. The furnace uses outside air for combustion. Excessive exposure to contaminated combustion air will result in safety and performance related problems. Avoid installing the unit near sources or vents that may contain the following contaminants: a. Permanent Wave Solutions b. Chlorinated Waxes and Cleaners c. Chlorine-Based Swimming Pool Chemicals d. Water Softening Chemicals e. De-Icing Salts or Chemicals f. Carbon Tetrachloride g. Halogen Type Refrigerants h. Cleaning Solvents (such as Perchloroethylene) i. Printing Inks, Paint Removers, Varnishes, etc. j. Hydrochloric Acid k. Cements and Glues l. Antistatic Fabric Softeners for Clothes Dryers m. Masonry Acid Washing Materials The Comfort Pack unit shall not be installed directly on carpeting, tile, or other combustible material other than wood flooring. The Comfort Pack may be installed with zero clearances on all sides. It is recommended that a minimum of 29 of unobstructed area be provided in front of the access panels for routine service and chassis removal. The grilles on the outside of the units should be kept clear of obstructions to permit proper operation of the furnace vent system. The vent system is designed for proper operation under all weather conditions and for winds up to 40 mph. Do not alter or extend the vent outlet. 10. The furnace venting system is an integral, independent, complete, and tested part of the Comfort Pack unit. It is not intended for field connection to any other venting system. Do not modify, alter or connect to the vent system in the unit. * 1/8 NPT plugged tapping for test gauge not permitted in Massachusetts. 1

11. If the Comfort Pack is installed so that supply ducts carry air circulated by the furnace to areas outside the space containing the furnace, the return air shall also be handled by a duct(s) sealed to the furnace casing and terminating outside the space containing the furnace. The supply air duct should be equipped with a removable inspection panel to allow for future inspections of the heat exchanger. 12. The Comfort Pack unit contains a 16 x 25 x 1 air filter located on the cooling chassis. Replacement of this filter with an equivalent type is necessary to maintain the performance of the furnace. The condition of the filter should be checked at least monthly. The air filter may be accessed by shutting off the unit and removing the lower access panel. The air filter may be removed by sliding it out of the filter holders. The unit should not be operated without the filter and lower access panel in place. 13. The installation is to be adjusted to obtain a temperature rise within the range(s) specified on the appliance rating plate. Furnace Service Warning: Power must be disconnected before servicing. 6. 7. The ignitor assembly may be removed and cleaned using emery cloth. The spark gap should be set at 1/8. The venter motor bearings are permanently lubricated. Lubrication of the motor is not recommended. Burner Orifice: This device generally does not need cleaning and only needs to be changed when a change of gas is involved. The orifice sizes that are used with natural or L.P. gas are shown on the rating plate. Orifices and labels are available from National Comfort Products when the gas is being field converted to a different gas than shown on the rating plate and label. It is also necessary to reset the combination gas valve to the proper outlet pressure shown on the rating plate. To prevent dropping the orifice into the burner housing, temporarily place something the size of a credit card across the venturi. Be careful not to damage the venturi tube and/or the bracket. Burner Service: The need to disassemble and clean the burner assembly is indicated when there is an accumulation of dirt, dust or lint in the burner/control compartment. After cleaning the compartment, remove the burner as described below: The air filter located on the cooling chassis should be maintained regularly. It should be checked at least monthly. Longer intervals between servicing may be justified depending upon the hours of unit operation and the cleanliness of the environment. A dirty air filter can adversely affect both heating and cooling operations, reduce heat exchanger life and increase energy usage. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. The furnace is designed to operate efficiently for many heating seasons with minimal servicing. The following procedures should be done on an annual basis, more often if the unit is in a dusty environment: 1. Clean all dirt, lint and grease from the combustion air openings and venter motor. If an accumulation of dirt, dust or lint is found in the burner/control compartment, it will be necessary to clean the compartment and to provide burner service as outlined below. 1. 2. 3. Shut the gas supply off ahead of the combination valve. Turn off the electric supply. Remove the entire upper access panel to expose the heat exchanger section and the burner/control compartment. 2. 3. 4. 5. Inspect the heat exchanger. If the supply air is ducted, remove the inspection panel from the duct to observe the heat exchanger. Clean if necessary. Check for cracks or holes. Replace the heat exchanger if any cracks or holes are found. Do not attempt to repair a damaged heat exchanger. Also, refer to burner service for additional information on inspecting the heat exchanger. Check the burner for scale, dust or lint accumulation. Clean if needed. Check the vent system for soundness. Replace any parts that do not appear sound. Check the wiring for any damage and replace if necessary. 4. 5. 6. 7. 8. Carefully loosen and remove the gas supply tube. Mark and disconnect the pressure switch wires. Disconnect the tubing and remove the pressure switch. Locate the secondary air shield end cap. Remove the four screws holding it to the air shield and remove the end cap. Locate the upper burner brackets (one on each side). Remove the two screws (one on each side) that attach the burner assembly to the secondary air shield assembly. Tilt the burner assembly slightly and lift it free from the retaining track under the burner assembly. Remove the burner assembly from the cabinet. 2

9. With the burner assembly removed, shine a flash light on the burner ribbons. Look for carbon buildup, scale, dust, lint, and/or anything that might restrict flow through the spaces between the burner ribbons. Holding the burner assembly so that any foreign material will fall away from the burner, use a stiff bristle brush to loosen and remove any foreign materials. If the burner is excessively dirty, remove one of the burner end caps. Remove the four screws that hold the end cap to the burner housing. Lightly tap the end cap to remove it. Clean all foreign material from the burner and venturi. After the burner is thoroughly clean, replace the end cap making certain that it is tight against the burner housing. VERIFY PROPER OPERATION AFTER SERVICING. NOTE: If any of the burner components are damaged or deteriorated, replace the burner assembly. REPLACEMENT PARTS GUIDE ITEM DESCRIPTION PART NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Complete Furnace Assembly 38 Mbh Complete Furnace Assembly 51Mbh Complete Furnace Assembly 64 Mbh Flame Rollout Switch Orifice Adapter Orifice Adaptor Lock Nut DSI Electrode Assembly Flame Sensor DSI Integrated Control Board w/cooling Relay High Temperature Limit Thermostat Pressure Switch High Altitude Pressure Switch Combination Gas Valve Venter Tube Assembly Venter Wheel Motor Assembly Heat Exchanger Assembly - 38 Mbh Heat Exchanger Assembly - 51 Mbh Heat Exchanger Assembly - 64 Mbh Full Burner Body Assembly - 38 Mbh Full Burner Body Assembly -51 Mbh Full Burner Body Assembly - 64 Mbh Control Plug Assembly (9 wire) Natural Gas Orifice - 38 Mbh Natural Gas Orifice - 51 Mbh Natural Gas Orifice - 64 Mbh L.P. Gas Orifice - 38 Mbh L.P. Gas Orifice - 51 Mbh L.P. Gas Orifice - 64 Mbh Control Plug Assembly (5 wire) 1/2 90 Street Elbow Pipe 1/2 90 Elbow Pipe 1/2 x 8 Pipe Threaded Both Ends 14208309 14208308 14208303 14208314 14208315 14208316 14208317 14208318 14208319 14208320 14208324 14208325 14208326 14208327 14208328 14208329 14208330 14208331 14208332 14208333 14208334 14208335 14208336 14208337 14208338 14208339 14208340 14208341 14208342 14208349 14208350 14208351 For proper performance and safety, it is important that replacement parts be obtained from National Comfort Products. Please refer to the parts list at left for the part numbers: National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 244-9579 3

Wiring Schematic/Gas Heat To Thermostat Door Sw Spark Ign Orange Contactor P1 Inducer Mtr K1 BK Dual Capacitor C Herm Fan BK S R RD Compressor Low Press Sw Orange Y G Y Brown WT Purple Cond Mtr Orange WT Note 1: Fan ON delay in cooling 35-40sec 1 High - 2 Medium High - 3 Medium - 4 Medium Low - 5 Low - Orange C Common - WT TO RELAY 1 TO 5 5 4 3 2 C Evp Mtr 230V COIL 5 6 2 3 4 1 1 Mode Terminal Heat - 3 Cool - 2 Limit Cooling Nominal Capacity Cooling Speed Gas Heat Value Heating Speed 12 Orange 38 18 51 24 64 30 Roll Out FLAME SENSOR Press Sw MV P1 Brown 14299990 4

Wiring Schematic/Gas Heat To Thermostat Door Sw Spark Ign Orange Contactor P1 Inducer Mtr K1 BK Dual Capacitor C Herm Fan BK S R RD Compressor Low Press Sw Orange Y G Y Brown WT Purple Cond Mtr Orange WT Note 1: Fan ON delay in cooling 35-40sec 1 High - 2 Medium High - 3 Medium - 4 Medium Low - 5 Low - Orange C Common - WT TO RELAY 1 TO 5 5 4 3 2 C Evp Mtr 230V COIL 5 6 2 3 4 1 1 Mode Terminal Heat - 3 Cool - 2 Limit Cooling Nominal Capacity Cooling Speed Gas Heat Value Heating Speed 12 Orange 38 18 51 24 64 30 Roll Out FLAME SENSOR Press Sw MV P1 Brown 14299882 5

Legend CONTROL STATUS STEADY ON FAST FLASH 1 FLASH 2 FLASH 3 FLASH 4 FLASH STEADY OFF FLAME STATUS STEADY ON SLOW FLASH FAST FLASH DSI INTEGRATED CONTROL MODULE GREEN LED Normal operation, no call for heat Normal operation, call for heat In lockout from failed ignition or flame loss Pressure switch does not close within 30 seconds Limit switch or rollout switch open Limit switch is closed before venter is energized Internal control fault or no power YELLOW LED Flame sensed Weak flame (current below 1.0 microamps = +/-50%) Undesired flame (valve open and no call for heat) FAN OFF DELAY SWITCH TIME 1 2 90 OFF ON 120 OFF OFF 160 ON OFF 180 ON ON TEST FLAME LED Y OK LED G FIELD CONTROL WIRING TOTAL WIRE LENGTH 150 250 350 DISTANCE FROM UNIT TO CONTROL 75 125 175 MIN. RECOMMENDED WIRE GAUGE #18 GAUGE WIRE #16 GAUGE WIRE #14 GAUGE WIRE OPERATION SEQUENCE 1. 2. 3. 4. 5. 6. 7. 8. SET THERMOSTAT AT LOWEST SETTING. TURN ON MANUAL GAS VALVE. TURN ON POWER TO UNIT. SET THERMOSTAT AT DESIRED SETTING. THERMOSTAT CALLS FOR HEAT, ENERGIZING THE VENTER MOTOR. VENTER PRESSURE SWITCH CLOSES, FIRING UNIT. BURNER FLAME IS SENSED, AND IN 30 SECONDS THE FAN MOTOR IS ENERGIZED. IF THE FLAME IS EXTINGUISHED DURING MAIN BURNER OPERATION, THE INTEGRATED CONTROL SYSTEM CLOSES THE MAIN VALVE AND MUST BE RE- SET BY INTERRUPTING POWER TO THE CONTROL CIRCUIT (SEE LIGHTING INSTRUCTIONS). NOTES 1. 2. 3. 4. 5. 6. THE FOLLOWING CONTROL IS A FIELD-INSTALLED OPTION: THERMOSTAT. DOTTED WIRING INSTALLED BY OTHERS. CAUTION: IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C EXCEPT FOR SENSOR LEAD WIRE AND LIMIT WIRING WHICH MUST BE 150 C. USE 18 GAUGE WIRE FOR ALL LOW VOLTAGE WIRING ON THE UNIT OR FOLLOW CHART ABOVE. LINE AND FAN MOTOR BRANCH WIRE SIZES SHOULD BE OF A SIZE TO PREVENT VOLTAGE DROPS BEYOND 5% OF SUPPLY LINE VOLTAGE. GROUND WIRE IS USED ONLY ON MODEL 64 UNITS. 6

COMFORT PACK R-410A - Gas Furnace Instructions - Rev 14299575-10/29/2014