LATCH UP TEST REPORT

Similar documents
TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

PCMini52 Digital RH & Temperature Mini Probe User s Manual

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Technical-Report for SL Lamp 5 W

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

WIO200 Water in oil sensor

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Apex MediTech ALC109 ALARM SYSTEM

Environment Test Report

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

IECEx Certificate of Conformity

6915 Highway 225, Deer Park, TX 77536

Rules for Intruder Alarm Systems

M7100 Pressure Transducer

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

A5364. Ionization Smoke Detector with Interconnect

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

PQS Independent type-testing protocol

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

Southern California Gas Company Customer Programs Department

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013

Test Report No.: Page 2 of 14

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

PQS Independent type-testing protocol

Supplementary Installation and Operating Instructions. Category II2G

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Laser Particle Sensor Module PM2009

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Laser Particle Sensor Module PM2008M

Heat and Smoke Release of a Ceiling-Installed Speaker

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Technical data sheet TDS0034

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

A5348 Ionization Smoke Detector with Interconnect and Timer

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

Laser Particle Sensor Module PM2008M

PQS performance specification

Report No. ECL01I Page 1 of 5. Test Report. Centre Testing International Pinbiao(Shanghai) Co., Ltd. Maritime Industry Division

Smart GPS Antenna A1035-D

Sensing light curtain as per DIN 18650/EN 16005

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Report Test Report

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Refrigerator/Freezer Thermometer

Vacuum drying oven for non-flammable solvents

Specification for On-Line UPS Battery Monitoring and Data Management System

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

02/11/2015

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Jun08 Rev A

JUL 18 Rev A1

Report VNLF Test Report

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Manufacturing Notes for RFMD2081

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Emerald 3000 MK3 GJD010 Lighting Controller

Drying and heating chambers. Series ED FD FED FP M

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Sensing light curtain as per DIN 18650/EN 16005

Technical data lumina MS4

Update on the new IEC standards and their impact on quality of PV modules

AQUACON. Chief characteristic for realizing this product family was:

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

IECRE OPERATIONAL DOCUMENT

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Substation Monitoring System

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Refrigerator/Freezer Thermometer

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Transcription:

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 1 of 8 LATCH UP TEST REPORT Company Address :Vango Technologies, Inc. :F/9, Haiyue Building, 788 Danfeng Rd, Binjiang District, Hangzhou, Zhejiang, P.R.China, 310051 Model Name :V9811A Date Received :November 11, 2016 Date Tested :November 11, 2016 TESTING LABORATORY IS ACCREDITED BY: IEC/IECQ 17025 certificate of independent test laboratory approval CB Certificate No.: 1.72.0031/B IECQ Certificate No.: IECQ-L NSAIUS 09.0005 ISO 9001 certificate is approved by TUV CERT certification body of TUV NORD Cert GmbH WE HEREBY CERTIFY THAT: The test(s) shown in the attachment were conducted according to the indicating procedures. We assume full responsibility for the accuracy and completeness of these tests and vouch for the qualifications of all personnel performing them. Name Signature Date Testing Engineer Jian shen 2016/11/11 Approving Manager Jianbo Song 2016/11/11 Note: 1. This report will be invalid if reproduced in whole or in part. 2. This report refers only to the specimen(s) submitted to test, and is invalid if used separately. 3. This report is ONLY valid with the examination seal and signature of this institute. 4. The tested specimen(s) will only be preserved for thirty days from the date issued, if not collected by the applicant. 5. The failure criteria of all ESD tests should be based on the result of parametric and functional testing conducted by the customer, which follows the statement of international standards. Thus, the judgment of the curve traces provided in this report is for reference ONLY.

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 2 of 8 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT... 3 2. LATCH UP TEST 2.1 TEST EQUIPMENT... 4 2.2 LABORATORY AMBIENCE CONDITION... 4 2.3 REFERENCE DOCUMENT... 4 2.4 TEST CONDITION... 4 2.5 SUMMARY OF TEST... 4 2.6 CONTENTS OF TEST... 5

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 3 of 8 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT MANUFACTURER DEVICE NAME PACKAGED / PIN COUNT :Vango Technologies, Inc. :V9811A :QFP64 REFERENCE DOCUMENT :JEDEC STANDARD NO.78D NOVEMBER 2011 TRIGGER CURRENT :50mA (±) ~200mA (±) Step:50mA (±) V SUPPLY OVER VOLTAGE TEST PULSE DURATION TEST TEMPERATURE SAMPLE QUANTITY FAILURE CRITERIA :3.25V~5.25V(+), Step: 1.0V(+) :2.0V~3.0V(+), Step: 1.0V(+) :10 ms :ROOM TEMPERATURE :9 pcs :If absolute Inom is < 25 ma, then absolute Inom + 10mA is used; Or If absolute Inom is > 25 ma, then > 1.4X absolute Inom is used;

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 4 of 8 2. LATCH UP TEST 2.1 TEST EQUIPMENT Test Equipment Equipment S/N Calibration Date: Recommended Due Date: KEYTEK ZAPMASTER MK2 768 1603181 April 19, 2016 April 18, 2017 2.2 LABORATORY AMBIENCE CONDITION Temperature:23±5 C Relative humidity:55%±10% (RH) 2.3 REFERENCE DOCUMENT The test is based on JEDEC STANDARD NO.78D NOVEMBER 2011 2.4 TEST CONDITION I Trigger Over Voltage Test 2.5 SUMMARY OF TEST Trigger Mode I Trigger (+) I Trigger (-) Over Volt Test V supply Test Pin I/P3.3V Sample Quantity Tested Result V or I Limits O/P3.3V 3 PASS +200mA +5.4V I Trigger : Class Ⅰ PASS +200mA +5.4V Temperature Classification: I/O3.3V PASS +200mA +5.4V I/P3.3V PASS -200mA -1.8V O/P3.3V 3 PASS -200mA -1.8V I/O3.3V PASS -200mA -1.8V VCC3.3V PASS +5.25V +600mA 3 VCC2.0V PASS +3.0V +600mA CLASSⅠ: For Latch-up test at room temperature CLASSⅡ: For Latch-up test at maximum-rate ambient temperature Group Pins I/P3.3V 2,3, 4,10-16,63,64 O/P3.3V 1 I/O3.3V 7,9,17-62 VCC2.0V 5 VCC3.3V 6 VSS 8,42

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 5 of 8 2.6 CONTENTS OF TEST I Trigger (Positive) Tested Pin Sample No. & Failed current (ma) #L1 #L2 #L3 2 PASS+200mA PASS+200mA PASS+200mA 3 PASS+200mA PASS+200mA PASS+200mA 10 PASS+200mA PASS+200mA PASS+200mA 11 PASS+200mA PASS+200mA PASS+200mA 12 PASS+200mA PASS+200mA PASS+200mA 13 PASS+200mA PASS+200mA PASS+200mA 14 PASS+200mA PASS+200mA PASS+200mA 15 PASS+200mA PASS+200mA PASS+200mA 16 PASS+200mA PASS+200mA PASS+200mA 63 PASS+200mA PASS+200mA PASS+200mA 64 PASS+200mA PASS+200mA PASS+200mA 4 PASS+200mA PASS+200mA PASS+200mA 1 PASS+200mA PASS+200mA PASS+200mA 5 PASS+200mA PASS+200mA PASS+200mA 6 PASS+200mA PASS+200mA PASS+200mA 9 PASS+200mA PASS+200mA PASS+200mA 17 PASS+200mA PASS+200mA PASS+200mA 18 PASS+200mA PASS+200mA PASS+200mA 19 PASS+200mA PASS+200mA PASS+200mA 20 PASS+200mA PASS+200mA PASS+200mA 21 PASS+200mA PASS+200mA PASS+200mA 22 PASS+200mA PASS+200mA PASS+200mA 23 PASS+200mA PASS+200mA PASS+200mA 24 PASS+200mA PASS+200mA PASS+200mA 25 PASS+200mA PASS+200mA PASS+200mA 26 PASS+200mA PASS+200mA PASS+200mA 27 PASS+200mA PASS+200mA PASS+200mA 28 PASS+200mA PASS+200mA PASS+200mA 29 PASS+200mA PASS+200mA PASS+200mA 30 PASS+200mA PASS+200mA PASS+200mA 31 PASS+200mA PASS+200mA PASS+200mA 32 PASS+200mA PASS+200mA PASS+200mA 33 PASS+200mA PASS+200mA PASS+200mA 34 PASS+200mA PASS+200mA PASS+200mA 35 PASS+200mA PASS+200mA PASS+200mA 36 PASS+200mA PASS+200mA PASS+200mA 37 PASS+200mA PASS+200mA PASS+200mA 38 PASS+200mA PASS+200mA PASS+200mA 39 PASS+200mA PASS+200mA PASS+200mA 40 PASS+200mA PASS+200mA PASS+200mA 41 PASS+200mA PASS+200mA PASS+200mA

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 6 of 8 42 PASS+200mA PASS+200mA PASS+200mA 43 PASS+200mA PASS+200mA PASS+200mA 44 PASS+200mA PASS+200mA PASS+200mA 45 PASS+200mA PASS+200mA PASS+200mA 46 PASS+200mA PASS+200mA PASS+200mA 47 PASS+200mA PASS+200mA PASS+200mA 48 PASS+200mA PASS+200mA PASS+200mA 49 PASS+200mA PASS+200mA PASS+200mA 50 PASS+200mA PASS+200mA PASS+200mA 51 PASS+200mA PASS+200mA PASS+200mA 52 PASS+200mA PASS+200mA PASS+200mA 53 PASS+200mA PASS+200mA PASS+200mA 54 PASS+200mA PASS+200mA PASS+200mA 55 PASS+200mA PASS+200mA PASS+200mA 56 PASS+200mA PASS+200mA PASS+200mA 57 PASS+200mA PASS+200mA PASS+200mA 58 PASS+200mA PASS+200mA PASS+200mA 59 PASS+200mA PASS+200mA PASS+200mA 60 PASS+200mA PASS+200mA PASS+200mA 61 PASS+200mA PASS+200mA PASS+200mA 7 PASS+200mA PASS+200mA PASS+200mA 62 PASS+200mA PASS+200mA PASS+200mA

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 7 of 8 I Trigger (Negative) Tested Pin Sample No. & Failed current (ma) #L4 #L5 #L6 2 PASS-200mA PASS-200mA PASS-200mA 3 PASS-200mA PASS-200mA PASS-200mA 10 PASS-200mA PASS-200mA PASS-200mA 11 PASS-200mA PASS-200mA PASS-200mA 12 PASS-200mA PASS-200mA PASS-200mA 13 PASS-200mA PASS-200mA PASS-200mA 14 PASS-200mA PASS-200mA PASS-200mA 15 PASS-200mA PASS-200mA PASS-200mA 16 PASS-200mA PASS-200mA PASS-200mA 63 PASS-200mA PASS-200mA PASS-200mA 64 PASS-200mA PASS-200mA PASS-200mA 4 PASS-200mA PASS-200mA PASS-200mA 1 PASS-200mA PASS-200mA PASS-200mA 5 PASS-200mA PASS-200mA PASS-200mA 6 PASS-200mA PASS-200mA PASS-200mA 9 PASS-200mA PASS-200mA PASS-200mA 17 PASS-200mA PASS-200mA PASS-200mA 18 PASS-200mA PASS-200mA PASS-200mA 19 PASS-200mA PASS-200mA PASS-200mA 20 PASS-200mA PASS-200mA PASS-200mA 21 PASS-200mA PASS-200mA PASS-200mA 22 PASS-200mA PASS-200mA PASS-200mA 23 PASS-200mA PASS-200mA PASS-200mA 24 PASS-200mA PASS-200mA PASS-200mA 25 PASS-200mA PASS-200mA PASS-200mA 26 PASS-200mA PASS-200mA PASS-200mA 27 PASS-200mA PASS-200mA PASS-200mA 28 PASS-200mA PASS-200mA PASS-200mA 29 PASS-200mA PASS-200mA PASS-200mA 30 PASS-200mA PASS-200mA PASS-200mA 31 PASS-200mA PASS-200mA PASS-200mA 32 PASS-200mA PASS-200mA PASS-200mA 33 PASS-200mA PASS-200mA PASS-200mA 34 PASS-200mA PASS-200mA PASS-200mA 35 PASS-200mA PASS-200mA PASS-200mA 36 PASS-200mA PASS-200mA PASS-200mA 37 PASS-200mA PASS-200mA PASS-200mA 38 PASS-200mA PASS-200mA PASS-200mA 39 PASS-200mA PASS-200mA PASS-200mA 40 PASS-200mA PASS-200mA PASS-200mA 41 PASS-200mA PASS-200mA PASS-200mA 42 PASS-200mA PASS-200mA PASS-200mA

1F Xinyicheng C Building, No.1618 Yishan Rd., Shanghai City, China. Page 8 of 8 43 PASS-200mA PASS-200mA PASS-200mA 44 PASS-200mA PASS-200mA PASS-200mA 45 PASS-200mA PASS-200mA PASS-200mA 46 PASS-200mA PASS-200mA PASS-200mA 47 PASS-200mA PASS-200mA PASS-200mA 48 PASS-200mA PASS-200mA PASS-200mA 49 PASS-200mA PASS-200mA PASS-200mA 50 PASS-200mA PASS-200mA PASS-200mA 51 PASS-200mA PASS-200mA PASS-200mA 52 PASS-200mA PASS-200mA PASS-200mA 53 PASS-200mA PASS-200mA PASS-200mA 54 PASS-200mA PASS-200mA PASS-200mA 55 PASS-200mA PASS-200mA PASS-200mA 56 PASS-200mA PASS-200mA PASS-200mA 57 PASS-200mA PASS-200mA PASS-200mA 58 PASS-200mA PASS-200mA PASS-200mA 59 PASS-200mA PASS-200mA PASS-200mA 60 PASS-200mA PASS-200mA PASS-200mA 61 PASS-200mA PASS-200mA PASS-200mA 7 PASS-200mA PASS-200mA PASS-200mA 62 PASS-200mA PASS-200mA PASS-200mA Over Voltage Test for V supply Tested Pin Sample No. & Failed Volt (V) #L7 #L8 #L9 5 PASS PASS PASS 6 PASS PASS PASS