Home Inspection Report

Similar documents
Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Home Inspection Report

Home Inspection Report

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex

Home Inspection Report

Property Condition Report

Home Inspection Report

American Property Inspectors of Northwest Florida, Inc.

Attention To Detail Home Inspections, LLC Marchester Dr. Wesley Chapel, FL Report prepared by: Steven Milek Certified NACHI Inspector

Axiom Property Inspections

Inspector FX Field Forms

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Steve Ramsey Home Inspections

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Canadian Property Inspections

Inspection Report 123 My Street Midland, GA

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Peconic Home Inspections, LLC Inspection Report. 123 Lane Suffolk, New York 11900

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Jeff Brown Inspections

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Extra Mile Inspection, Inc.

fieldwork report contains the Functional

Bayshore House Inspections LLC

Inside Out Home Inspections

McKinney Inspection Company

Excellent Home Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Watson Home Inspection Services, LLC.

Cascade Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

Inspector Gadget Homes

Space Coast Home Inspections LLC

Hope Home Inspections LLC rd Ln E Sarasota, FL

Home Inspection Report

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

Hearth and Homes Inspections, llc

I. STRUCTURAL SYSTEMS

Inspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services

MHI Services Inc. Property Inspection Report

RW West Consultants. Property Inspection Report

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

Property Inspection Report

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Canadian Property Inspections

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

All In One Home Inspections

SPS Home Inspections, LLC

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

REPAIR ESTIMATE GUIDE

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Troy's Home Inspection Services LLC

Residential * Commercial * Mobile Homes * New Construction

HOME INSPECTION REPORT

Inspection Report. Inspection Date: 5/1/2010. Single Family Sample Report. Property Address: Address. City State Zip. All In One Home Inspection LLC

Maintence/Renewal Report

Doyle Home Inspections

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

The Villas of Wyldewood

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

Residential Construction and Remodeling Estimates. compliments of. pillartopost.com

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

Tennessee Valley Property Inspections

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

The Ultimate Home Inspection Checklist

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

This Report Was Prepared For: Property Address Inspected:

Patriot Home Inspections

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

HOME INSPECTION REPORT

Estimated Repair, Replacement, and Upgrade Costs

Amendment to the Inspection Report


FAIRA TRANSPARENCY REPORTS. July 6, 2016

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

Examples of Acclaim s Energy-Efficiency Green Technology

26632 Timberlane Dr SE, Covington, WA 98042

THE HEMLOCK 3 BD 2.5 BA 1371 sq ft

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Kirkland, WA February 16, 2018

Transcription:

Home Inspection Report 7325 Dogwood Ave California City, CA 93505 Prepared for: Sherri Liu Prepared by: 6317 Sandstone Ct Lancaster, Ca 93536 Dj Durment, 661-902-9477

Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 3 Roof 5 Garage/Carport 6 Electrical 7 Structure 8 Attic 8 Air Conditioning 9 Heating System 9 Plumbing 10 Bathroom 10 Kitchen 12 Bedroom 12 Living Space 13 Laundry Room/Area 14 Summary 15

Page 2 of 19 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Functional with no obvious signs of defect. Item not present or not found. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. Marginal Item is not fully functional and requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function. General Information Property Information Property Address 7325 Dogwood Ave City California City State CA Zip 93505 Contact Name Kent Steffes Phone 661-945-7305 Client Information Client Name Sherri Liu Client Address Box 4501 City California City State Ca Zip 93505 Inspection Company Inspector Name Donald Durment Company Name Address 6317 Sandstone Ct City Lancaster State Ca Zip 93536 Phone 661 902 9477 Fax none E-Mail avamericaninspections @ gmail.com File Number 03132015 Amount Received $ 275 Conditions Others Present None Property Occupied Vacant Estimated Age 10 Years Entrance Faces South Inspection Date March 13 2015 Start Time 1PM End Time 7PM Electric On Yes Gas/Oil On Yes Water On Yes Temperature 80 Degrees Weather Hot & Clear Soil Conditions Dry Building Type Single family Garage Attached, Direct access Sewage Disposal Septic How Verified Multiple Listing Service Water Source City How Verified Multiple Listing Service Additions/Modifications None

Page 3 of 19 General Information (Continued) Permits Obtained N/A How Verified Visual Inspection Lots and Grounds 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Marginal 16. Driveway: Concrete Walks: Concrete Steps/Stoops: Concrete Porch: Concrete Patio: Deck: Balcony: Grading: Minor slope Swale: Adequate slope and depth for drainage Vegetation: Few shrubs with dirt Window Wells: Retaining Walls: Basement Stairwell: Exterior Surface Drain: Culvert drain Fences: Wood fence needs repair work in several locations Lawn Sprinklers: Exterior Entire structure Exterior Surface 1. Type: EIFS stucco 2. Marginal Fascia: Wood Perimeter Facia needs paint then on a regular basis depending on weather 3. 4. Defective Soffits: Plywood Paint Reccomended Door Bell: Inoperative

Page 4 of 19 Exterior (Continued) 5. 6. Marginal 7. 8. 9. 10. 11. Entry Doors: Metal Patio Door: French door Secured very crudely unnecessary holes now in doors. Unable to inspect operation Windows: Vinyl slider Storm Windows: Window Screens: Vinyl mesh Basement Windows:, Marginal Exterior Lighting: Surface mount New Fixture required at garage egress, motion light in back yard not required but inoperable, all other surface mount fixtures in place and working on day of inspection 12., Marginal Exterior Electric Outlets: 110 VAC GFCI Outlet at front Power door non operational, all other exterior outlets working malfunctions were prevalent on day of inspection throughout

Page 5 of 19 Exterior (Continued) 13. Hose Bibs: Rotary 60 PSI Water pressure 14. Gas Meter: Propane System 15., Marginal Main Gas Valve: Located at Propane tank Slight odor of propane noticed at tank shut off noted Roof Main Roof Surface 1. Method of Inspection: On roof 2. Unable to Inspect: 10% 3. Material: Asphalt shingle Water path

Page 6 of 19 Roof (Continued) 4. Type: Gable, Hip and Valley 5. Approximate Age: Less than 5 years 6. Flashing: Pre Formed Metal 7. Valleys: Asphalt shingle 8. Skylights: 9. Plumbing Vents: ABS 10. Electrical Mast: Underground utilities 11. Gutters: 12. Downspouts: None Chimney 13. Chimney: 14. Flue/Flue Cap: 15. Chimney Flashing: Garage/Carport Attached Garage 1. Type of Structure: Direct Access Attached Car Spaces: 2 2. Garage Doors: Metal 3. Not Inspected Door Operation: Mechanized Door locked unable to inspect operation 4. 5. 6. 7. 8. 9. 10. 11. 12. Door Opener: Genie Appears in good condition, but impossible to say without actually operating unit Exterior Surface: Stucco Roof: Asphalt shingle Roof Structure: 2x4 Truss Service Doors: Metal Ceiling: Texture paint Walls: Textured Paint Noticed cracking in areas of garage Drywall. This is common and even more prevalent in areas that do not have climate control,i.e garage Floor/Foundation: Poured concrete Hose Bibs: Gate

Page 7 of 19 Garage/Carport (Continued) 13., Marginal Electrical: 220 VAC, 110 VAC, 110 VAC outlets and lighting circuits GFCI working as designed on day of inspection At different locations, Garage will need same qualified electrical work to be performed, safety is of the utmost importance in all of the electrical comments 14. 15. 16. Smoke Detector: Heating: Windows: Vinyl slider Window tracks need blown in dirt removed for better operation 17. 18. Gutters: Downspouts: Electrical All safety issues noted by inspector should be corrected by qualified,licensed electrician immediately. Box appears tohave been altered by unqualified persons 1. Service Size Amps: 400 Volts: 110-240 VAC 2. Service: Copper 3. 4. 5. 6. 7. 8. Wires in box should be neat and orderly for service calls 120 VAC Branch Circuits: Copper 240 VAC Branch Circuits: Copper Aluminum Wiring: Conductor Type: Romex Ground: Rod in ground only Smoke Detectors: Hard wired with battery back up

Page 8 of 19 Electrical (Continued) Recessed in exterior wall Electric Panel 9. Marginal Manufacturer: Murray Number 10 red and black wire abandoned. suggest removal 10. 11. 12. 13. 14. 15. 16. Arrows point out at least two abandoned wires left in electrical panel Maximum Capacity: 400 Amp Main Breaker Size: 200 Amps Breakers: Copper and Aluminum Fuses: AFCI: 110 volt GFCI: Present Is the panel bonded? Yes Structure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Structure Type: Wood frame Foundation: Poured slab Differential Movement: No movement or displacement noted Beams: Solid wood Bearing Walls: Frame Joists/Trusses: 2x4 Piers/Posts: Floor/Slab: Poured slab Stairs/Handrails: Subfloor: Attic Main Attic 1. Method of Inspection: In the attic 2. Unable to Inspect: 15% 3. Roof Framing: 2x4 Truss 4. Sheathing: Strand board 5. Ventilation: Gable and soffit vents 6. Insulation: Batts, Blown in 7. Insulation Depth: 6" 8. Vapor Barrier: 9. Attic Fan: 10. House Fan: 11. Moisture Penetration: appears completely dry 12. Bathroom Fan Venting: Electric fan

Page 9 of 19 Air Conditioning Main AC System 1. A/C System Operation: Appears serviceable, Functional 2. Condensate Removal: PVC 3. Exterior Unit: Mounted on roof 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Manufacturer: York Model Number: D1NP036NO5606NXA Serial Number: NOK5969121 Area Served: Whole building Approximate Age: Original to home Fuel Type: 220-240 VAC Temperature Differential: 24 Degrees in 20 minutes Type: Central A/C Capacity: 4 Ton Visible Coil: Copper core with aluminum fins Refrigerant Lines: Serviceable condition Electrical Disconnect: Breaker disconnect Exposed Ductwork: Insulated flex Blower Fan/Filters: Direct drive with disposable filter Thermostats: Programmable Heating System It is always recommended that prior to move in that buyers contact the Has Company for a free system evaluation for safety and performance Roof mounted Heating System 1. Heating System Operation: Adequate 2. Manufacturer: York 3. Type: Forced air Capacity: 100,000 BTUHR 4. Area Served: Whole building Approximate Age: Original to home 5. Fuel Type: Propane gas 6. Heat Exchanger: 6 Burner 7. Unable to Inspect: 15% 8. Blower Fan/Filter: Direct drive with disposable filter 9. Distribution: Insulflex duct 10. Circulator: Pump 11. Draft Control: Automatic 12. Flue Pipe: Single wall 13. Controls: Limit switch 14. Devices: 15. Humidifier:

Page 10 of 19 Heating System (Continued) 16. Thermostats: Programmable 17. Suspected Asbestos: No Plumbing 1. 2. Service Line: Cast iron Main Water Shutoff: Frontt east of home near fire hydrant main water shut off located in box 3. Water Lines: Polybutelene 4. Drain Pipes: ABS 5. Service Caps: Accessible 6. Vent Pipes: ABS 7. Gas Service Lines: Copper, Cast iron Garage Water Heater 8., Marginal Water Heater Operation: Functional at time of inspection Unit is working as designed, I am hearing dripping in wall directly behind water heater, possibly in attic where roof lines cross. I could not determine exact location without cutting wall open 9. Manufacturer: General Electric 10. Model Number: GP40to6AVGOO Serial Number: GELP0306VGOO 11. Type: Propane Capacity: 40 Gal. 12. Approximate Age: Original to home Area Served: 13. Flue Pipe: Single wall 14. TPRV and Drain Tube: Copper Bathroom Master Bathroom 1. 2. 3. 4. 5. 6. Closet: Single small Ceiling: Texture paint Walls: Textured Paint Floor: Ceramic tile Doors: Hollow wood Windows: Vinyl slider

Page 11 of 19 Bathroom (Continued) 7. Defective Electrical: 110 VAC outlets and lighting circuits Smoke damage seen here, Unknown when this took place 8. Counter/Cabinet: Composite and wood 9. Sink/Basin: Molded single bowl 10. Faucets/Traps: Stainless Steel 11. Shower/Surround: Fiberglass pan and fiberglass surround 12. Toilets: 3 Gallon Tank 13. HVAC Source: Heating system register 14. Ventilation: Electric ventilation fan and window 1st floor main Bathroom 15. Ceiling: Texture paint 16. Walls: Textured Paint 17. Floor: Ceramic tile 18. Doors: Hollow wood 19. Windows: 20. Marginal Electrical: 110 VAC outlets and lighting circuits Lighting fixture Missing fixtures along with missing, light in bathroom fan not working sparatic power in bathrooms and entire west side of home 21. 22. 23. 24. 25. 26. 27. Counter/Cabinet: Composite and wood Sink/Basin: Molded single bowl Faucets/Traps: Chrome Tub/Surround: Fiberglass tub and fiberglass surround Toilets: 3 Gallon Tank HVAC Source: Heating system register Ventilation: Electric ventilation fan

Page 12 of 19 Kitchen 1st Floor Kitchen 1. Cooking Appliances: Whirlpool 2. Ventilator: 3. Disposal: Badger At first unit was seized, this is common when disposals sit un operated. unit free and working 4. Defective Dishwasher: Frigidaire Door latching mechanism not present Missing latch location 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Air Gap Present? Yes Trash Compactor: Refrigerator: Microwave: General Electric Sink: Stainless Steel Electrical: 110 VAC outlets and lighting circuits, 110 VAC GFCI Plumbing/Fixtures: Stainless Steel Counter Tops: Ceramic tile Cabinets: wood doors along with composite boxes Pantry: Ceiling: Texture paint Walls: Textured Paint Floor: Ceramic tile Windows: Vinyl slider HVAC Source: Heating system register Bedroom 1st Floor Master 1. 2. 3. 4. 5. 6. 7. Defective 8. 9. West Bedroom 10. 11. 12. Bedroom Closet: Walk In and Large Ceiling: Texture paint Walls: Textured Paint Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: 110 VAC outlets and lighting circuits No electrical power in ceiling or wall outlets HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up Closet: Walk In and Large Ceiling: Texture paint Walls: Textured Paint

Page 13 of 19 Bedroom (Continued) 13. 14. 15. 16. Defective 17. 18. East Bedroom 19. Marginal Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: No electrical power in room HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up 20. 21. 22. 23. 24. 25. 26. 27. Ceiling: Texture paint Walls: Textured Paint Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: 110 VAC outlets and lighting circuits No electrical power exist in this room as well HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up Defective Closet: Large Closet doors missing Living Space Living Room Living Space 1. Closet: Single 2. Ceiling: Texture paint 3. Walls: Textured Paint 4. Floor: Carpet 5. Doors: French As stated earlier doors secured in a crude manner 6. Windows: Fixed 7. Electrical: 110 VAC outlets and lighting circuits 8. HVAC Source: Heating system register 9. Smoke Detector: Hard wired with battery back up Dining Room Living Space 10. Closet: 11. Ceiling: Texture paint 12. Walls: Textured Paint 13. Floor: Ceramic tile 14. Doors:

Page 14 of 19 Living Space (Continued) 15. Defective Electrical: 110 VAC outlets and lighting circuits 4 outlets in dining area not working, lighting fixture not in place 16. 17. HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up Unable to determine why paticular fixtures have been removed Laundry Room/Area Garage Laundry 1. 2. 3. 4. 5. 6. 7. Marginal 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. Room/Area Closet: Ceiling: Texture paint Walls: Textured Paint Floor: Poured Doors: Windows: Electrical: 110 VAC GFCI, 110 VAC, 220 VAC Same electrical issues that have been occuring in entire home Smoke Detector: HVAC Source: Laundry Tub: Laundry Tub Drain: Washer Hose Bib: Gate valves Washer and Dryer Electrical: 220-240 VAC, 110 VAC Dryer Vent: Rigid metal Dryer Gas Line: Cast iron Washer Drain: Wall mounted drain Floor Drain: Final Comments This home will need all safety related issues resolved by qualified tradesman. The Electrical being the most prevalent, the plumbing will need to be evaluated as well as any propane comments. The structure of the home is working as designed with normal cracking in exterior as well as interior finishes. In my opinion the roof appears in good condition along with climate control systems. I feel that I have done a complete inspection and noted safety issues that were present on day of inspection. Thank you for having AV American Inspections be of service to you.

Page 15 of 19 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds 1. Fences: Wood fence needs repair work in several locations Exterior 2. Fascia: Wood Perimeter Facia needs paint then on a regular basis depending on weather 3. Patio Door: French door Secured very crudely unnecessary holes now in doors. Unable to inspect operation 4. Exterior Lighting: Surface mount New Fixture required at garage egress, motion light in back yard not required but inoperable, all other surface mount fixtures in place and working on day of inspection

Page 16 of 19 Exterior (Continued) Exterior Lighting: (continued) 5. Exterior Electric Outlets: 110 VAC GFCI Outlet at front door non operational, Power malfunctions all other exterior outlets working on day of inspection were prevalent throughout 6. Main Gas Valve: Located at Propane tank Slight odor of propane noticed at tank shut off noted Garage/Carport 7. Attached Garage Electrical: 220 VAC, 110 VAC, 110 VAC outlets and lighting circuits GFCI working as designed on day of inspection At different locations, Garage will need same qualified electrical work to be performed, safety is of the utmost importance in all of the electrical comments

Page 17 of 19 Marginal Summary (Continued) Electrical 8. Recessed in exterior wall Electric Panel Manufacturer: Murray Number 10 red Arrows point out at least two and black wire abandoned. suggest removal abandoned wires left in electrical panel Plumbing 9. Garage Water Heater Water Heater Operation: Functional at time of inspection Unit is working as designed, I am hearing dripping in wall directly behind water heater, possibly in attic where roof lines cross. I could not determine exact location without cutting wall open Bathroom 10. 1st floor main Bathroom Electrical: 110 VAC outlets and lighting circuits Lighting fixture missing, light in bathroom fan not working Missing fixtures along with sparatic power in bathrooms and entire west side of home Bedroom 11. East Bedroom Closet: Large Closet doors missing Laundry Room/Area 12. Garage Laundry Room/Area Electrical: 110 VAC GFCI, 110 VAC, 220 VAC Same electrical issues that have been occuring in entire home

Page 18 of 19 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Exterior 1. Door Bell: Inoperative Bathroom Smoke damage seen here, Unknown when this took place 2. Master Bathroom Electrical: 110 VAC outlets and lighting circuits Kitchen 3. 1st Floor Kitchen Dishwasher: Frigidaire Door latching mechanism not present Missing latch location Bedroom 4. 1st Floor Master Bedroom Electrical: 110 VAC outlets and lighting circuits No electrical power in ceiling or wall outlets 5. West Bedroom Electrical: No electrical power in room 6. East Bedroom Electrical: 110 VAC outlets and lighting circuits No electrical power exist in this room as well Living Space 7. Dining Room Living Space Electrical: 110 VAC outlets and lighting circuits 4 outlets in dining area not working, lighting fixture not in place Unable to determine why paticular fixtures have been removed

Page 19 of 19 Defective Summary (Continued)

Home Inspection Report 7325 Dogwood Ave California City, CA 93505 Prepared for: Sherri Liu Prepared by: 6317 Sandstone Ct Lancaster, Ca 93536 Dj Durment, 661-902-9477

Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 3 Roof 5 Garage/Carport 6 Electrical 7 Structure 8 Attic 8 Air Conditioning 9 Heating System 9 Plumbing 10 Bathroom 10 Kitchen 12 Bedroom 12 Living Space 13 Laundry Room/Area 14 Summary 15

Page 2 of 19 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Functional with no obvious signs of defect. Item not present or not found. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. Marginal Item is not fully functional and requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function. General Information Property Information Property Address 7325 Dogwood Ave City California City State CA Zip 93505 Contact Name Kent Steffes Phone 661-945-7305 Client Information Client Name Sherri Liu Client Address Box 4501 City California City State Ca Zip 93505 Inspection Company Inspector Name Donald Durment Company Name Address 6317 Sandstone Ct City Lancaster State Ca Zip 93536 Phone 661 902 9477 Fax none E-Mail avamericaninspections @ gmail.com File Number 03132015 Amount Received $ 275 Conditions Others Present None Property Occupied Vacant Estimated Age 10 Years Entrance Faces South Inspection Date March 13 2015 Start Time 1PM End Time 7PM Electric On Yes Gas/Oil On Yes Water On Yes Temperature 80 Degrees Weather Hot & Clear Soil Conditions Dry Building Type Single family Garage Attached, Direct access Sewage Disposal Septic How Verified Multiple Listing Service Water Source City How Verified Multiple Listing Service Additions/Modifications None

Page 3 of 19 General Information (Continued) Permits Obtained N/A How Verified Visual Inspection Lots and Grounds 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Marginal 16. Driveway: Concrete Walks: Concrete Steps/Stoops: Concrete Porch: Concrete Patio: Deck: Balcony: Grading: Minor slope Swale: Adequate slope and depth for drainage Vegetation: Few shrubs with dirt Window Wells: Retaining Walls: Basement Stairwell: Exterior Surface Drain: Culvert drain Fences: Wood fence needs repair work in several locations Lawn Sprinklers: Exterior Entire structure Exterior Surface 1. Type: EIFS stucco 2. Marginal Fascia: Wood Perimeter Facia needs paint then on a regular basis depending on weather 3. 4. Defective Soffits: Plywood Paint Reccomended Door Bell: Inoperative

Page 4 of 19 Exterior (Continued) 5. 6. Marginal 7. 8. 9. 10. 11. Entry Doors: Metal Patio Door: French door Secured very crudely unnecessary holes now in doors. Unable to inspect operation Windows: Vinyl slider Storm Windows: Window Screens: Vinyl mesh Basement Windows:, Marginal Exterior Lighting: Surface mount New Fixture required at garage egress, motion light in back yard not required but inoperable, all other surface mount fixtures in place and working on day of inspection 12., Marginal Exterior Electric Outlets: 110 VAC GFCI Outlet at front Power door non operational, all other exterior outlets working malfunctions were prevalent on day of inspection throughout

Page 5 of 19 Exterior (Continued) 13. Hose Bibs: Rotary 60 PSI Water pressure 14. Gas Meter: Propane System 15., Marginal Main Gas Valve: Located at Propane tank Slight odor of propane noticed at tank shut off noted Roof Main Roof Surface 1. Method of Inspection: On roof 2. Unable to Inspect: 10% 3. Material: Asphalt shingle Water path

Page 6 of 19 Roof (Continued) 4. Type: Gable, Hip and Valley 5. Approximate Age: Less than 5 years 6. Flashing: Pre Formed Metal 7. Valleys: Asphalt shingle 8. Skylights: 9. Plumbing Vents: ABS 10. Electrical Mast: Underground utilities 11. Gutters: 12. Downspouts: None Chimney 13. Chimney: 14. Flue/Flue Cap: 15. Chimney Flashing: Garage/Carport Attached Garage 1. Type of Structure: Direct Access Attached Car Spaces: 2 2. Garage Doors: Metal 3. Not Inspected Door Operation: Mechanized Door locked unable to inspect operation 4. 5. 6. 7. 8. 9. 10. 11. 12. Door Opener: Genie Appears in good condition, but impossible to say without actually operating unit Exterior Surface: Stucco Roof: Asphalt shingle Roof Structure: 2x4 Truss Service Doors: Metal Ceiling: Texture paint Walls: Textured Paint Noticed cracking in areas of garage Drywall. This is common and even more prevalent in areas that do not have climate control,i.e garage Floor/Foundation: Poured concrete Hose Bibs: Gate

Page 7 of 19 Garage/Carport (Continued) 13., Marginal Electrical: 220 VAC, 110 VAC, 110 VAC outlets and lighting circuits GFCI working as designed on day of inspection At different locations, Garage will need same qualified electrical work to be performed, safety is of the utmost importance in all of the electrical comments 14. 15. 16. Smoke Detector: Heating: Windows: Vinyl slider Window tracks need blown in dirt removed for better operation 17. 18. Gutters: Downspouts: Electrical All safety issues noted by inspector should be corrected by qualified,licensed electrician immediately. Box appears tohave been altered by unqualified persons 1. Service Size Amps: 400 Volts: 110-240 VAC 2. Service: Copper 3. 4. 5. 6. 7. 8. Wires in box should be neat and orderly for service calls 120 VAC Branch Circuits: Copper 240 VAC Branch Circuits: Copper Aluminum Wiring: Conductor Type: Romex Ground: Rod in ground only Smoke Detectors: Hard wired with battery back up

Page 8 of 19 Electrical (Continued) Recessed in exterior wall Electric Panel 9. Marginal Manufacturer: Murray Number 10 red and black wire abandoned. suggest removal 10. 11. 12. 13. 14. 15. 16. Arrows point out at least two abandoned wires left in electrical panel Maximum Capacity: 400 Amp Main Breaker Size: 200 Amps Breakers: Copper and Aluminum Fuses: AFCI: 110 volt GFCI: Present Is the panel bonded? Yes Structure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Structure Type: Wood frame Foundation: Poured slab Differential Movement: No movement or displacement noted Beams: Solid wood Bearing Walls: Frame Joists/Trusses: 2x4 Piers/Posts: Floor/Slab: Poured slab Stairs/Handrails: Subfloor: Attic Main Attic 1. Method of Inspection: In the attic 2. Unable to Inspect: 15% 3. Roof Framing: 2x4 Truss 4. Sheathing: Strand board 5. Ventilation: Gable and soffit vents 6. Insulation: Batts, Blown in 7. Insulation Depth: 6" 8. Vapor Barrier: 9. Attic Fan: 10. House Fan: 11. Moisture Penetration: appears completely dry 12. Bathroom Fan Venting: Electric fan

Page 9 of 19 Air Conditioning Main AC System 1. A/C System Operation: Appears serviceable, Functional 2. Condensate Removal: PVC 3. Exterior Unit: Mounted on roof 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Manufacturer: York Model Number: D1NP036NO5606NXA Serial Number: NOK5969121 Area Served: Whole building Approximate Age: Original to home Fuel Type: 220-240 VAC Temperature Differential: 24 Degrees in 20 minutes Type: Central A/C Capacity: 4 Ton Visible Coil: Copper core with aluminum fins Refrigerant Lines: Serviceable condition Electrical Disconnect: Breaker disconnect Exposed Ductwork: Insulated flex Blower Fan/Filters: Direct drive with disposable filter Thermostats: Programmable Heating System It is always recommended that prior to move in that buyers contact the Has Company for a free system evaluation for safety and performance Roof mounted Heating System 1. Heating System Operation: Adequate 2. Manufacturer: York 3. Type: Forced air Capacity: 100,000 BTUHR 4. Area Served: Whole building Approximate Age: Original to home 5. Fuel Type: Propane gas 6. Heat Exchanger: 6 Burner 7. Unable to Inspect: 15% 8. Blower Fan/Filter: Direct drive with disposable filter 9. Distribution: Insulflex duct 10. Circulator: Pump 11. Draft Control: Automatic 12. Flue Pipe: Single wall 13. Controls: Limit switch 14. Devices: 15. Humidifier:

Page 10 of 19 Heating System (Continued) 16. Thermostats: Programmable 17. Suspected Asbestos: No Plumbing 1. 2. Service Line: Cast iron Main Water Shutoff: Frontt east of home near fire hydrant main water shut off located in box 3. Water Lines: Polybutelene 4. Drain Pipes: ABS 5. Service Caps: Accessible 6. Vent Pipes: ABS 7. Gas Service Lines: Copper, Cast iron Garage Water Heater 8., Marginal Water Heater Operation: Functional at time of inspection Unit is working as designed, I am hearing dripping in wall directly behind water heater, possibly in attic where roof lines cross. I could not determine exact location without cutting wall open 9. Manufacturer: General Electric 10. Model Number: GP40to6AVGOO Serial Number: GELP0306VGOO 11. Type: Propane Capacity: 40 Gal. 12. Approximate Age: Original to home Area Served: 13. Flue Pipe: Single wall 14. TPRV and Drain Tube: Copper Bathroom Master Bathroom 1. 2. 3. 4. 5. 6. Closet: Single small Ceiling: Texture paint Walls: Textured Paint Floor: Ceramic tile Doors: Hollow wood Windows: Vinyl slider

Page 11 of 19 Bathroom (Continued) 7. Defective Electrical: 110 VAC outlets and lighting circuits Smoke damage seen here, Unknown when this took place 8. Counter/Cabinet: Composite and wood 9. Sink/Basin: Molded single bowl 10. Faucets/Traps: Stainless Steel 11. Shower/Surround: Fiberglass pan and fiberglass surround 12. Toilets: 3 Gallon Tank 13. HVAC Source: Heating system register 14. Ventilation: Electric ventilation fan and window 1st floor main Bathroom 15. Ceiling: Texture paint 16. Walls: Textured Paint 17. Floor: Ceramic tile 18. Doors: Hollow wood 19. Windows: 20. Marginal Electrical: 110 VAC outlets and lighting circuits Lighting fixture Missing fixtures along with missing, light in bathroom fan not working sparatic power in bathrooms and entire west side of home 21. 22. 23. 24. 25. 26. 27. Counter/Cabinet: Composite and wood Sink/Basin: Molded single bowl Faucets/Traps: Chrome Tub/Surround: Fiberglass tub and fiberglass surround Toilets: 3 Gallon Tank HVAC Source: Heating system register Ventilation: Electric ventilation fan

Page 12 of 19 Kitchen 1st Floor Kitchen 1. Cooking Appliances: Whirlpool 2. Ventilator: 3. Disposal: Badger At first unit was seized, this is common when disposals sit un operated. unit free and working 4. Defective Dishwasher: Frigidaire Door latching mechanism not present Missing latch location 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Air Gap Present? Yes Trash Compactor: Refrigerator: Microwave: General Electric Sink: Stainless Steel Electrical: 110 VAC outlets and lighting circuits, 110 VAC GFCI Plumbing/Fixtures: Stainless Steel Counter Tops: Ceramic tile Cabinets: wood doors along with composite boxes Pantry: Ceiling: Texture paint Walls: Textured Paint Floor: Ceramic tile Windows: Vinyl slider HVAC Source: Heating system register Bedroom 1st Floor Master 1. 2. 3. 4. 5. 6. 7. Defective 8. 9. West Bedroom 10. 11. 12. Bedroom Closet: Walk In and Large Ceiling: Texture paint Walls: Textured Paint Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: 110 VAC outlets and lighting circuits No electrical power in ceiling or wall outlets HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up Closet: Walk In and Large Ceiling: Texture paint Walls: Textured Paint

Page 13 of 19 Bedroom (Continued) 13. 14. 15. 16. Defective 17. 18. East Bedroom 19. Marginal Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: No electrical power in room HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up 20. 21. 22. 23. 24. 25. 26. 27. Ceiling: Texture paint Walls: Textured Paint Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: 110 VAC outlets and lighting circuits No electrical power exist in this room as well HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up Defective Closet: Large Closet doors missing Living Space Living Room Living Space 1. Closet: Single 2. Ceiling: Texture paint 3. Walls: Textured Paint 4. Floor: Carpet 5. Doors: French As stated earlier doors secured in a crude manner 6. Windows: Fixed 7. Electrical: 110 VAC outlets and lighting circuits 8. HVAC Source: Heating system register 9. Smoke Detector: Hard wired with battery back up Dining Room Living Space 10. Closet: 11. Ceiling: Texture paint 12. Walls: Textured Paint 13. Floor: Ceramic tile 14. Doors:

Page 14 of 19 Living Space (Continued) 15. Defective Electrical: 110 VAC outlets and lighting circuits 4 outlets in dining area not working, lighting fixture not in place 16. 17. HVAC Source: Heating system register Smoke Detector: Hard wired with battery back up Unable to determine why paticular fixtures have been removed Laundry Room/Area Garage Laundry 1. 2. 3. 4. 5. 6. 7. Marginal 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. Room/Area Closet: Ceiling: Texture paint Walls: Textured Paint Floor: Poured Doors: Windows: Electrical: 110 VAC GFCI, 110 VAC, 220 VAC Same electrical issues that have been occuring in entire home Smoke Detector: HVAC Source: Laundry Tub: Laundry Tub Drain: Washer Hose Bib: Gate valves Washer and Dryer Electrical: 220-240 VAC, 110 VAC Dryer Vent: Rigid metal Dryer Gas Line: Cast iron Washer Drain: Wall mounted drain Floor Drain: Final Comments This home will need all safety related issues resolved by qualified tradesman. The Electrical being the most prevalent, the plumbing will need to be evaluated as well as any propane comments. The structure of the home is working as designed with normal cracking in exterior as well as interior finishes. In my opinion the roof appears in good condition along with climate control systems. I feel that I have done a complete inspection and noted safety issues that were present on day of inspection. Thank you for having AV American Inspections be of service to you.

Page 15 of 19 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds 1. Fences: Wood fence needs repair work in several locations Exterior 2. Fascia: Wood Perimeter Facia needs paint then on a regular basis depending on weather 3. Patio Door: French door Secured very crudely unnecessary holes now in doors. Unable to inspect operation 4. Exterior Lighting: Surface mount New Fixture required at garage egress, motion light in back yard not required but inoperable, all other surface mount fixtures in place and working on day of inspection

Page 16 of 19 Exterior (Continued) Exterior Lighting: (continued) 5. Exterior Electric Outlets: 110 VAC GFCI Outlet at front door non operational, Power malfunctions all other exterior outlets working on day of inspection were prevalent throughout 6. Main Gas Valve: Located at Propane tank Slight odor of propane noticed at tank shut off noted Garage/Carport 7. Attached Garage Electrical: 220 VAC, 110 VAC, 110 VAC outlets and lighting circuits GFCI working as designed on day of inspection At different locations, Garage will need same qualified electrical work to be performed, safety is of the utmost importance in all of the electrical comments

Page 17 of 19 Marginal Summary (Continued) Electrical 8. Recessed in exterior wall Electric Panel Manufacturer: Murray Number 10 red Arrows point out at least two and black wire abandoned. suggest removal abandoned wires left in electrical panel Plumbing 9. Garage Water Heater Water Heater Operation: Functional at time of inspection Unit is working as designed, I am hearing dripping in wall directly behind water heater, possibly in attic where roof lines cross. I could not determine exact location without cutting wall open Bathroom 10. 1st floor main Bathroom Electrical: 110 VAC outlets and lighting circuits Lighting fixture missing, light in bathroom fan not working Missing fixtures along with sparatic power in bathrooms and entire west side of home Bedroom 11. East Bedroom Closet: Large Closet doors missing Laundry Room/Area 12. Garage Laundry Room/Area Electrical: 110 VAC GFCI, 110 VAC, 220 VAC Same electrical issues that have been occuring in entire home

Page 18 of 19 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Exterior 1. Door Bell: Inoperative Bathroom Smoke damage seen here, Unknown when this took place 2. Master Bathroom Electrical: 110 VAC outlets and lighting circuits Kitchen 3. 1st Floor Kitchen Dishwasher: Frigidaire Door latching mechanism not present Missing latch location Bedroom 4. 1st Floor Master Bedroom Electrical: 110 VAC outlets and lighting circuits No electrical power in ceiling or wall outlets 5. West Bedroom Electrical: No electrical power in room 6. East Bedroom Electrical: 110 VAC outlets and lighting circuits No electrical power exist in this room as well Living Space 7. Dining Room Living Space Electrical: 110 VAC outlets and lighting circuits 4 outlets in dining area not working, lighting fixture not in place Unable to determine why paticular fixtures have been removed

Page 19 of 19 Defective Summary (Continued)