/Oct/2014 Rev E

Similar documents
Cat 6 Unshielded Patch cords

Cat 6 Shielded Patch cords

/Oct/2014 Rev B

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report 1/Jul/2005 Rev. A

Mar11 Rev B

Jan05 Rev A EC

Jun08 Rev A

Mar11 Rev C

Jun08 Rev C

Two Circuit Heavy Duty Burner Connector

/Mar/2014 Rev A

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

FEB. 17 Rev. A1

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Jul07 Rev C

HMN-D2 Insert Series

INTERNATIONAL STANDARD

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

APR 17 Rev A

Apr06 Rev A

Jan07 Rev B

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

INTERNATIONAL STANDARD

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

TE Connectivity's AMP NETCONNECT Cable Management

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Fiber Optic Distribution Cables (6-144 Fibers)

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

USB 3.0 Plug & Receptacle

JUL 18 Rev A1

This document is a preview generated by EVS

INTERNATIONAL STANDARD

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Universal Retention Modules 02 MAR 10 Rev A

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

CATEGORY 6A FTP RJ45 SOLUTION

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

SolderSleeve Insulated Electrical Termination Devices

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

INTERNATIONAL STANDARD

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

INTERNATIONAL STANDARD

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

This document is a preview generated by EVS

This document is a preview generated by EVS

Application Specification MAG-MATE* Poke-In Tab Terminals

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

ETSI TS V1.2.1 ( )

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

Multi-Core Fire Resistant Cable

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

ETSI TS V1.2.1 ( )

Heavy Head Hand Tools , , , and AUG 15 Rev K

Product Specification Qualification Test Report

GASTEC QA. Approval Requirements 136

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

4120 Fire Alarm Network Reference

FEB 16 Rev T

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

5. Identification products.

SECTION AUTOMATIC TRANSFER SWITCHES

Rules for Classification and Construction Additional Rules and Guidelines

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

commercial-type cabling and connectivity products into the industrial landscape.

TYPE APPROVAL CERTIFICATE

This document is a preview generated by EVS

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

ITU-T L.404. Field mountable single-mode optical fibre connectors

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Compact Module. Category 6A FTP Cabling System 1.1

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

SOLARLOK Interconnection System Installation Manual

INTERNATIONAL STANDARD

Draft ES V1.1.1 ( )

Duct Cable GYTS-144B1.3

Universal Connectivity Platform

INTERNATIONAL STANDARD

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Inverted Through Board Surface

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

QUADRAX D-SUB CONNECTORS

Heavy Head Hand Crimping Tools (HHHT) [ ]

Transcription:

Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity Cat 6 unshielded patch cord assemblies used to connect building wiring for data and voice networking systems. 1.2 Qualification When tests are performed on subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using applicable inspection plan and product drawing. 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the customer drawing or any TE Connectivity (TE) documents listed below, the customer drawing and TE documents shall take precedence. In the event of conflict between the requirements of this specification and the industrial standards, this specification shall take precedence. 2.1 TE Connectivity Documents A. Relevant customer drawing B. TEC-138-702: Supplier Requirements for Product Environmental Compliance C. 108-93018: Product Specification - Copper LAN cable 2.2 Industrial Standards: A. ISO / IEC 11801 : Generic Cabling for Customer Premises B. EN 50173-1: Information Technology; Generic Cabling Systems C. ANSI/TIA/EIA 568-C.2: Balanced Twisted-Pair Telecommunications Cabling and Components Standards D. IEC 61935-1: Generic cabling systems - Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801. Part 1: Installed cabling. E. IEC 61935-2: Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801. Patch cords and work area cords. Test Specifications as indicated in Fig. 1. F. IEC 61156-6: Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up to 1000MHz Work area wiring Sectional specification. G. IEC 60603-7-4 Connectors for electronic equipment. Detail specification for 8-way, unshielded, free & fixed connectors, for data transmission with frequencies up to 250 MHz. 2014 TE Connectivity AMP España, S.L.U., Barcelona (Spain) a TE Connectivity Ltd. Company. All International Rights Reserved * Trademark 1 of 7 Indicates change TE logo is a trademark LOC IK

H. IEC 60512-4-1: Electromechanical Components for Electronic Equipment; Basic Testing procedures and measuring methods. Test 4a: Voltage Proof. 3. REQUIREMENTS 3.1 Design and Construction Product shall be of design, construction and physical dimensions specified on applicable customer drawing. 3.2 Standard length Applicable standard lengths: from 0.5 meter to 20 meter (both included). For other lengths, put in contact with your sales representative. 3.3 Materials Materials shall be in accordance to TE Connectivity requirements about environmental-related substances as per TE Connectivity specification TEC-138-702. The material of the cable jacket is identified on the customer drawing and shall comply with the standards mentioned in Product Specification 108-93018 Copper LAN cable. 3.4 Ratings Operating Temperature: -20 to 60ºC 3.5 Packaging Each assembly shall be supplied in a clear bag. 3.6 Bending radius The minimum bending radius is 8x outside diameter during installation and 4x the outside diameter after installation. 3.7 Performance requirements and test procedures Product is designed to meet electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions. Test Description Requirement Test Procedure VISUAL Examination product. Wire map of AMPTRAC connection (9 th wire) (only applicable for AMPTRAC versions) Voltage proof (only applicable for AMPTRAC versions) Meets requirements of product drawing. ELECTRICAL Continuity and short circuit Wire map configuration as per TIA 568B Continuity and short circuit (between pogo pin and plug shield) 1 minute hold with no breakdown or flashover Visual inspection criteria as defined in IEC 61935-2, Paragraph 5.1. Any device which ensures quality Any device which ensures quality. (See figure 2 as information) IEC 60512-4-1 1500 volts AC peak voltage to be applied between pogo pin and plug shield. Maximum leakage current 5 ma Rev E 2 of 7

TRANSMISSION (See Figure 3 for transmission tests in Channel set up) Return Loss Class E Channel Return Loss IEC 61935-1, Paragraph 4.11 Insertion Loss Class E Channel Insertion Loss IEC 61935-1, Paragraph 4.5 NEXT Loss Class E Channel NEXT requirements IEC 61935-1, Paragraph 4.7 PS NEXT Loss Class E Channel PS NEXT requirements (PS NEXT is computed from NEXT Loss values) ACR-N Class E Channel ACR-N requirements IEC 61935-1, Paragraph 4.8 PS ACR-N Class E Channel PS ACR-N requirements (PS ACR-N is computed from ACR-N values) FEXT Loss (There are no requirements for FEXT IEC 61935-1, Paragraph 4.9 Loss) ACR-F Class E Channel ACR-F requirements IEC 61935-1, Paragraph 4.10 PS ACR-F Class E Channel PS ACR-F requirements (PS ACR-F is computed from ACR-F values) Propagation delay Class E Channel Prop Delay IEC 61935-1, Paragraph 4.6 Delay Skew Class E Channel Delay Skew IEC 61935-1, Paragraph 4.6 MECHANICAL Crimping Height Relevant IEC 60603-7-X standard Indicator with needle-point probes or equivalent. It shall be measured at the front of the contact. Tensile Strength Force applied: 50 N according to the IEC 61935-2, Paragraph 6.2. standard. Duration: 5 seconds (See Figure 4 as information) Torsion Force Force applied: 10 N x cm (See Figure 5 as information) (specified by TE Duration: 5 seconds Connectivity) Maximum Rotation angle 45º NOTE See Test Sequence in paragraph 4.2 Figure 6 Figure 1: Requirements and test procedures for Cat 6 unshielded patch cords Rev E 3 of 7

Figure 2: AMPTRAC connection continuity and short-circuit test procedure Figure 3: Test set up - Channel configuration Figure 4: Tensile strength test procedure Test based on 1 rotation x 1 side Maximum rotation angle 45º Maximum distance between shield and cable clamp 5mm Torque value to be applied between shield and cable jacket 10 N cm Figure 5: Torsion force test procedure Rev E 4 of 7

NOTE In general, patch cords are components of a Channel cabling configuration. Channels are length limited by standards in order to achieve specific requirements, for this reason all component lengths have to be considered for obtaining the expected cabling performance. In case of a Class E Channel 2-connector model: Maximum patch cords total length allowed is obtained by the following equation: Max _ Length m RatioA m Length m Patch _ cords 104 Permanent _ Link RatioB Where RatioA and RatioB are the cable insertion loss ratios which depend on cable type (solid or stranded). In general, they take the following values: For stranded cables, Ratio _ stranded 1. 5 For solid cables, Ratio _ solid 1. 0 4. PRODUCT QUALIFICATION AND REQUALIFICATION 4.1 Sample Selection Samples shall be selected at random from current production. For qualification purpose, all test groups shall consist of a minimum of 5 samples per relevant length per product family. Rev E 5 of 7

4.2 Test sequence Test Sequence Standard version AMPTRAC version Examination of product 1, 17 1, 19 Wire Map 3 3 AMPTRAC connection: Continuity and shortcircuit - 4, 20 (only for AMPTRAC versions) Voltage Proof (only for AMPTRAC versions) - 5, 21 Return Loss 4, 18 6, 22 Insertion Loss 5, 19 7, 23 NEXT 6, 20 8, 24 PS NEXT Loss 7, 21 9, 25 ACR-N 8, 22 10, 26 PS ACR-N 9, 23 11, 27 FEXT 10, 24 12,28 ACR-F 11, 25 13, 29 PS ACR-F 12, 26 14, 30 Propagation Delay 13, 27 15, 31 Delay Skew 14, 28 16, 32 Crimping Height 2 2 Tensile Strength 15 17 Torsion Force 16 18 Figure 6: Test sequence 4.3 Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, requalification testing shall be initiated, consisting of all or part of the original testing sequence as determined by TE Connectivity. 5. QUALITY ASSURANCE PROVISIONS Quality provisions are based upon the philosophy of TQM (Total Quality Management) with a system approved to EN ISO 9001 by Lloyds Register Quality Assurance. 5.1 Responsibility for quality Unless otherwise stated in the purchase order, it shall be the supplier's responsibility to assure qualification and lot conformance to this specification. The supplier may utilize his own or other testing and inspection facilities acceptable to the buyer. Rev E 6 of 7

5.2 Qualification conformance For the purposes of internal qualification, the program shall consist of examinations and tests to determine conformance with the requirements of this specification. It shall be performed once, on introduction of the product. Subsequent design changes shall be partially or fully re-qualified depending upon their area of impact in the context of product functionality. Regular requalification testing shall be performed as defined by the Quality Department. 5.3 Manufacturing follow-up TE Connectivity products target Six Sigma levels of performance by the integration of capable processes from the development throughout the entire supply chain. The goal is to reduce variability to achieve zero defects for products and services. Systems used are based on preventive and statistical techniques during development and manufacturing. This also includes suppliers of materials, components or systems. Dedicated procedures for supplier selection, development and follow-up are implemented to ensure conformance to TQM and specification requirements. Best demonstrated practices are identified and implemented throughout the company, with a continuing challenge to identify opportunities for innovation and improvement. 6. REVISION SUMMARY This paragraph is reserved for a revision summary of changes and additions made to this specification. TE Connectivity AMP España, S.L.U. was Tyco Electronics AMP España, S.A. TE Connectivity logo is included in this revision. TE Connectivity was AMP NETCONNECT* in paragraph 1.1. Content. TE Connectivity was Tyco Electronics in paragraphs 2. Applicable Documents, 3.3. Materials, 4.3. Requalification Testing, 5.3 Manufacturing follow up and Figure 1. From paragraph 2.2. Industrial Standards and Figure 1, ISO/IEC 11801 2 nd edition has been superseded by ISO 11801. From paragraph 2.2. Industrial Standards, ANSI/TIA/EIA 568-B.2-1 has been superseded by ANSI/TIA/EIA 568-C.2. Rev E 7 of 7