ecofit pure Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

Similar documents
ecofit pure Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

ecofit pure Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

HOME. Installation and maintenance instructions. Installation and maintenance instructions. For the competent person GB, IE COMBI

Installation and maintenance

Installation and maintenance

Operating instructions

Operating instructions

Operating instructions

Operating instructions

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

Installation and maintenance

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VU GB 656/4-5 A

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

ecotec pro Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VUW

Nitron Condense Nitron Condense 28 (H-TR)

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

ecocraft exclusive Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE

ecotec plus boiler user guide

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VU, VUW

ecotec plus Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VUI

Installation and maintenance instructions. For the competent person. Installation and maintenance instructions. ecotec plus. VU 80, 100, 120 kw GB, IE

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Operating instructions

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

Operating instructions

flexotherm exclusive Installation and maintenance instructions Installation and maintenance instructions For the competent person

/2010 US/CA

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

ir-range 8G /03.15 Changes reserved.

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

For the owner. Operating manual. ecotec. Gas wall boilers with condensing appliance technology VU 466/4 VU 656/4

Logic+ Combi

Tankless Water Heater

Gas Instantaneous Water Heater

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

allstor buffer cylinder Instructions for use Instructions for use For the operator Publisher/manufacturer Vaillant GmbH

USER GUIDE LOGIC HEAT H

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

ecotec GB, IE Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

USER GUIDE VOGUE MAX SYSTEM

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Universal Fire Tube Boiler Wall Mount Models

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

GB24 & GB30. User Manual

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Mikrofill Ethos Condensing combination boiler

Residential Gas Hybrid Water Heater

Installation and maintenance instructions

Operating Instructions

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Installation and maintenance instructions

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Light oil / kerosene burner

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

WHE 2.24 / WHE 2.24 FF

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

User s Information Manual

User s Information Manual

Operating instructions

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Operating instructions Page 12

USERS GUIDE. LOGIC+ Combi 24, 30, 35

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

- Data Brochure Steam Control 279

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

arotherm Installation instructions Installation instructions For the competent person VWL../2 A 230 V Publisher/manufacturer Vaillant GmbH

ecotec Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

ecotec exclusive GB, IE Installation and maintenance instructions

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

SEALED THERMAL STORE

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Forced draught gas burner

User s Information Manual

USERS MANUAL FOR GAS BOILERS

Installation, operating and servicing instructions

Transcription:

Installation and maintenance instructions For the competent person Installation and maintenance instructions ecofit pure 6-630 G, IE Publisher/manufacturer Vaillant GmbH erghauser Str. 40 D-4859 Remscheid Tel. +49 9 8 0 Fax +49 9 8 80 info@vaillant.de www.vaillant.de

Contents Contents Safety... 3. ction-related warnings... 3. Risk caused by inadequate qualifications... 3.3 Intended use... 3.4 General safety information... 3.5 Regulations (directives, laws, standards)... 5 Notes on the documentation... 6. Observing other applicable documents... 6. Storing documents... 6.3 Validity of the instructions... 6.4 enchmark... 6 3 Product description... 6 3. Compartment Ventilation... 6 3. Information on the identification plate... 6 3.3 Functional elements: Pure boiler... 7 3.4 CE label... 7 4 ssembly... 7 4. Transporting the unit... 7 4. Unpacking the product... 7 4.3 Checking the scope of delivery... 7 4.4 Dimensions... 8 4.5 Minimum clearances... 8 4.6 Clearance from combustible components... 8 4.7 Using the installation template... 8 4.8 Wall-mounting the product... 8 4.9 Removing/installing the front casing... 9 4.0 Removing/installing the side section... 9 5 Installation... 0 5. Checking the gas meter... 0 5. Gas and water connections... 0 5.3 Connecting the drain line for the expansion relief valve... 5.4 Connecting the condensate drain pipework... 5.5 Electrical installation... 6 Operation... 3 6. Operating concept... 3 6. Installer level overview... 3 6.3 Calling up the installer level... 3 6.4 Live Monitor (status codes)... 3 6.5 Using check programmes... 4 7 Start-up... 4 7. Carrying out the initial start-up... 4 7. Checking the type of gas... 4 7.3 Checking the factory setting... 4 7.4 Checking and treating the heating water/filling and supplementary water... 4 7.5 voiding danger arising from insufficient water pressure... 5 7.6 Switching on the product... 5 7.7 Filling and purging the heating installation... 6 7.8 Filling the condensate siphon... 6 7.9 Filling the hot water circuit... 6 7.0 Checking the gas flow rate... 6 7. Checking and adjusting the gas settings... 7 7. Checking leak-tightness... 8 8 dapting the unit to the heating installation... 8 8. urner anti-cycling time... 9 8. Setting the pump output... 9 8.3 Setting the bypass valve... 0 8.4 Setting the hot water temperature... 0 9 Handing the product over to the operator... 0 Troubleshooting... 0. Rectifying faults... 0. Calling up and clearing the fault memory... 0.3 Resetting parameters to factory settings... 0.4 Preparing the repair work... 0.5 Replacing defective components... 0.6 Checking the product for leak-tightness... 4 Inspection and maintenance... 4. Using original seals... 4. Observing inspection and maintenance intervals... 4.3 Procuring spare parts... 4.4 Checking the CO₂ content... 4.5 Setting the CO₂ content... 4.6 Removing the gas-air mixture unit... 5.7 Cleaning the heat exchanger... 6.8 Checking the burner... 6.9 Checking the ignition electrode... 6.0 Cleaning the condensate siphon... 6. Installing the gas-air mixture unit... 6. Draining the product... 7.3 Checking the admission pressure of the expansion vessel... 7.4 Completing inspection and maintenance work... 7.5 Checking the product for leak-tightness... 7 Decommissioning the product... 7 3 Customer service... 7 ppendix... 8 Overview of diagnostics codes... 8 Status codes Overview... 3 C Overview of fault codes... 3 D Connection diagram: Pure boiler... 35 E Connection diagram: Pure boiler (30 kw)... 36 F Inspection and maintenance work Overview... 37 G Opening in the flue pipe... 38 G. Positioning of the opening of a fan-supported flue gas pipe... 38 G. Horizontal terminal positioning... 39 H Commissioning Checklist... 40 I Technical data... 44 Index... 48 Installation and maintenance instructions ecofit pure 00030533_0

Safety Safety. ction-related warnings Classification of action-related warnings The action-related warnings are classified in accordance with the severity of the possible danger using the following warning signs and signal words: Warning symbols and signal words Danger! Imminent danger to life or risk of severe personal injury Danger! Risk of death from electric shock Warning. Risk of minor personal injury Caution. Risk of material or environmental damage. Risk caused by inadequate qualifications The following work must only be carried out by competent persons who are sufficiently qualified to do so: Installation Disassembly Installation Start-up Maintenance Repair Decommissioning Observe all instructions that are included with the product. Proceed in accordance with the current state of technology. Observe all applicable directives, standards, laws and other regulations..3 Intended use There is a risk of injury or death to the user or others, or of damage to the product and other property in the event of improper use or use for which it is not intended. The product is intended as a heat generator for closed heating installations and for hot water generation. Depending on the gas-fired boiler type, the products referred to in these instructions must only be installed and operated in conjunction with the air/flue pipe accessories listed in the other applicable documents. Intended use includes the following: observance of accompanying operating, installation and servicing instructions for the product and any other system components installing and fitting the product in accordance with the product and system approval compliance with all inspection and maintenance conditions listed in the instructions. Intended use also covers installation in accordance with the IP class. ny other use that is not specified in these instructions, or use beyond that specified in this document shall be considered improper use. ny direct commercial or industrial use is also deemed to be improper. Caution. Improper use of any kind is prohibited..4 General safety information.4. Risk of death from escaping gas What to do if you smell gas in the building: void rooms that smell of gas. If possible, open doors and windows fully and ensure adequate ventilation. Do not use naked flames (e.g. lighters, matches). Do not smoke. Do not use any electrical switches, mains plugs, doorbells, telephones or other communication systems in the building. If it is safe to do so, close the emergency control valve or the main isolator. 00030533_0 ecofit pure Installation and maintenance instructions 3

Safety If possible, close the gas isolator cock on the product. Warn other occupants in the building by yelling or banging on doors or walls. Leave the building immediately and ensure that others do not enter the building. Notify the gas supply company or the National Grid +44 (0) 800 999 by telephone once you are outside of the building..4. Risk of death from escaping flue gas If you operate the product with an empty condensate siphon, flue gas may escape into the room air. In order to operate the product, ensure that the condensate siphon is always full..4.3 Risk of death due to blocked or leaking flue gas routes Installation errors, damage, tampering, unauthorised installation sites or similar can cause flue gas to escape and result in a risk of poisoning. What to do if you smell flue gas in the property: Open all accessible doors and windows fully to provide ventilation. Switch off the product. Check the flue gas routes in the product and the flue gas diversions..4.4 Risk of death due to explosive and flammable materials Do not use or store explosive or flammable materials (e.g. petrol, paper, paint) in the installation room of the product..4.5 Risk of death from electric shock There is a risk of death from electric shock if you touch live components. efore commencing work on the product: Unplug the mains plug. Or disconnect the product from the power supply by switching off all power supplies (electrical partition with a contact opening of at least 3 mm, e.g. fuse or line protection switch). Secure against being switched back on again. Wait for at least 3 minutes until the condensers have discharged..4.6 Risk of death due to lack of safety devices The schematic drawings included in this document do not show all safety devices required for correct installation. Install the necessary safety devices in the system. Observe the applicable national and international laws, standards and guidelines..4.7 Risk of poisoning and burns caused by escaping hot flue gases Only operate the product if the air/flue pipe has been completely installed. With the exception of short periods for testing purposes, only operate the product when the front casing is installed and closed..4.8 Risk of being burned or scalded by hot components Only carry out work on these components once they have cooled down..4.9 Risk of injury due to the heavy weight of the product Make sure that the product is transported by at least two people..4.0 Risk of corrosion damage due to unsuitable combustion and room air Sprays, solvents, chlorinated cleaning agents, paint, adhesives, ammonia compounds, dust or similar substances may lead to corrosion on the product and in the air/flue pipe. Ensure that the supply of combustion air is always free of fluorine, chlorine, sulphur, dust, etc. Ensure that no chemical substances are stored at the installation site. If you are installing the product in hairdressing salons, painter's or joiner's workshops, cleaning businesses or similar 4 Installation and maintenance instructions ecofit pure 00030533_0

Safety locations, choose a separate installation room in which the room air is technically free of chemical substances..4. Risk of material damage caused by leak detection sprays and liquids Leak detection sprays and liquids block the filter of the mass flow sensor on the Venturi, and thus destroy the mass flow sensor. During repair work, do not apply any leak detection sprays or liquids to the covering cap on the filter of the Venturi..4. Risk of material damage caused by frost Do not install the product in rooms prone to frost..4.3 Risk of material damage caused by using an unsuitable tool Use the correct tool to tighten or loosen screw connections..5 Regulations (directives, laws, standards) Observe the national regulations, standards, guidelines and laws. 00030533_0 ecofit pure Installation and maintenance instructions 5

Notes on the documentation Notes on the documentation. Observing other applicable documents You must observe all the operating and installation instructions included with the system components.. Storing documents Pass these instructions and all other applicable documents on to the system operator..3 Validity of the instructions These instructions apply only to: Product article number rticle number Gas Council Number VU 6/6-3 (H-G) 00000395 4-694-03 VU 56/6-3 (H-G) 00000396 4-694-04 VU 86/6-3 (H-G) 00000397 4-694-05 3 Product description 3. Compartment Ventilation The boilers are very high efficiency appliances. s a consequence the heat loss from the appliance casing during operation is very low. Compartment ventilation is not required as the products are only certified, and can only be fitted with a concentric flue system. 3. Information on the identification plate The identification plate is mounted on the underside of the product in the factory. The identification plate keeps record of the country in which the product is to be installed. Information on the identification plate Meaning arcode with serial number VU 56/6-3 (H-G) 00000398 4-694-06 VU 306/6-3 (H-G) 00000399 4-694-07.4 enchmark Vaillant is a licensed member of the enchmark Scheme. enchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer s instructions by a competent person approved at the time by the Health and Safety Executive and that it meets the requirements of the appropriate uilding Regulations. The enchmark Checklist can be used to demonstrate compliance with uilding Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the enchmark Code of Practice which is available from the Heating and Hotwater Industry Council who manage and promote the Scheme. enchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk Serial number ecofit pure H, G0 kpa (0 mbar) Cat. Condensing technology Type: Xx3(x) PMS PMW V/Hz W IP Pn Pnc P Qn Qnw T max. NOx Code (DSN) For quality control purposes; 3rd and 4th digits = year of production For quality control purposes; 5th and 6th digits = week of production For identification purposes; 7th to 6th digits = product article number For quality control purposes; 7th to 0th digits = place of manufacture Product designation Factory setting for type of gas and gas connection pressure Unit category Efficiency class of the boiler in accordance with EC Directive 9/4/EEC Permissible flue gas connections Maximum water pressure in heating mode Maximum water pressure in hot water handling mode Electrical connection Max. electrical power consumption Level of protection Heating mode Hot water generation Nominal heat output range in heating mode Nominal heat output range in heating mode (condensing technology) Nominal heat output range in hot water handling mode Nominal heating load range in heating mode Nominal heating load range in hot water handling mode Max. flow temperature NOx class for the product Specific product code 6 Installation and maintenance instructions ecofit pure 00030533_0

ssembly 4 Information on the identification plate Meaning 3.4 CE label Read the instructions. GC no. Gas council number 3.3 Functional elements: Pure boiler 0 The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the identification plate. The declaration of conformity can be viewed at the manufacturer's site. 9 8 7 6 5 4 3 3 4 5 4 ssembly 4. Transporting the unit Important: With regard to the regulations of 99 concerning the manual handling of loads, the unit exceeds the weight that can be lifted by a single person. 4.. General Hold the load as close as possible to your body. void rotational movements. Instead, reposition your feet. If the unit is being lifted by two persons, ensure your movements are coordinated during lifting. void bending your upper body do not lean forwards or to the side. Wear suitable non-slip protective gloves in order to protect your hands against sharp edges. Ensure that you are carrying the load securely. If required, get somebody to assist you in this. 4.. Unloading the box from the delivery van 7 6 It is recommended that two people lift the unit together. Lift the box using the straps provided. Use safe lifting techniques keep your back straight and bend your legs at the knee. Hold the load as close as possible to your body. If the unit is being lifted by two persons, ensure your movements are coordinated during lifting. If required, get somebody to assist you in this. Electronics box Heating circuit expansion relief valve 3 Condensate siphon 4 Flue gas pipe 5 Pressure sensor 6 Flue gas analysis point (for rear flue gas connection) 7 Ignition transformer 8 Gas valve 9 ir intake pipe 0 Fan Supply air measuring stub pipe (for upper flue gas connection) Flue gas analysis point (for upper flue gas connection) 3 Primary heat exchanger 4 Heating expansion vessel 5 Purge hose 6 Heating pump 7 ypass 4. Unpacking the product. Remove the product from its box.. Remove the protective film from all of the product's components. 4.3 Checking the scope of delivery Check that the scope of delivery is complete and intact. Quantity Description Heat generator Hanging bracket Flexible condensate drain pipework 4 3/4" seals 3 /" seals Service valve Gas isolator cock Connection pipe (heating flow and return) 00030533_0 ecofit pure Installation and maintenance instructions 7

4 ssembly Quantity Description 4.5 Minimum clearances Gas pipe Expansion relief valve discharge pipe Installation template Enclosed documentation 4.4 Dimensions C C D 3 96 3 85 3 390 4 70 Minimum clearance 50 mm (upper air/flue gas connection) 0 mm (air/flue gas connection on the rear) C 50 mm 5 mm (70 mm if the side panels ought to be removed) D 600 mm It is not necessary to maintain a clearance between the product and components made of combustible materials that go beyond the minimum clearances. 4.6 Clearance from combustible components It is not necessary to maintain a clearance between the product and components made of combustible materials that go beyond the minimum clearances ( Page 8). 4.7 Using the installation template Use the installation template to ascertain the locations at which you need to drill holes and make breakthroughs. 4.8 Wall-mounting the product 34 70 Note If you are using the rear air/flue gas connection, install the air/flue pipe before you wall-mount the product. 50 5 Heating flow Gas connection 3 Heating return 4 Connection on the back of the air/flue pipe 5 Connection on the top of the air/flue pipe. Check whether the wall has sufficient load-bearing capacity to bear the operational weight of the product. 8 Installation and maintenance instructions ecofit pure 00030533_0

ssembly 4. Check if the supplied fixing material may be used for the wall. Conditions: The load-bearing capacity of the wall is sufficient, The fixing material may be used for the wall Wall-mount the product as described. Conditions: The load-bearing capacity of the wall is not sufficient Ensure that wall-mounting apparatus on-site has a sufficient load-bearing capacity. Use individual stands or primary walling, for example. Do not wall-mount the product if you cannot provide wall-mounting apparatus with a sufficient load-bearing capacity. Conditions: The fixing material may not be used for the wall Wall-mount the product as described using the permitted fixing material provided on-site. 4.9 Removing/installing the front casing 4.9. Removing the front casing 4.9. Installing the front casing Refit the components in the reverse order. 4.0 Removing/installing the side section 4.0. Removing the side section Caution. Risk of material damage caused by mechanical deformation. Removing both side sections may cause mechanical distortion in the product, which may cause damage to the piping, for example, and potentially result in leaks. lways remove only one side section never both side sections at the same time. Note If there is sufficient lateral clearance (at least 70 mm), you can remove the side section to facilitate maintenance or repair work. C C x D. Undo the two screws ().. Gently press the front casing backwards in the centre so that the latching lug is released. 3. Pull the front casing forwards at the bottom edge. 4. Lift the front casing upwards from the bracket.. Tilt the electronics box forward.. Hold on to the side section so that it cannot fall and unscrew both screws (), one from the top and one from the bottom. 3. Tilt the side section to the outside and move it downwards and out. 00030533_0 ecofit pure Installation and maintenance instructions 9

5 Installation 4.0. Installing the side section Refit the components in the reverse order. Only solder connection pieces if the connection pieces are not yet screwed to the service valves. 5 Installation Danger! Risk of scalding and/or damage due to incorrect installation leading to escaping water. Stresses in the supply line can cause leaks. Make sure there is no voltage in the supply lines when they are installed. Caution. Risk of material damage caused by residues in the pipelines. Welding remnants, sealing residues, dirt or other residues in the pipelines may damage the product. Flush the heating installation thoroughly before installing the product. Note pply thermal insulation to the water pipes to the boiler outlet and to the system. Preliminary work. Check that the system volume and the volumetric capacity of the expansion vessel are compatible. If the volume of the expansion vessel is insufficient for the system. Install an additional expansion vessel in the heating return, as close to the product as possible. Install a non-return flap at the product's outlet (heating flow).. Ensure that the system has the following components: cold water stop cock for the unit gas stopcock for the unit filling and draining device in the heating installation 5. Checking the gas meter Make sure that the existing gas meter is capable of passing the rate of gas supply required. 5. Gas and water connections Caution. Risk of damage caused by incorrect gas connection installation. Excess test pressure or operating pressure may cause damage to the gas valve. Check the leak-tightness of the gas valve using a maximum pressure of kpa (0 mbar). 3 Caution. Risk of material damage caused by corrosion Due to non-diffusion-tight plastic pipes in the heating installation, air gets into the heating water. ir in the heating water causes corrosion in the heat generator circuit and in the product. If you use non-diffusion-tight plastic pipes in the heating installation, ensure that no air gets into the heat generator circuit. Caution. Risk of material damage due to heat transfer during soldering. Heating flow connection, G3/4 Gas connection, G/ 3 Heating return connection, G3/4. Connect the water and gas connections in accordance with the applicable standards.. Purge the gas line before start-up. 3. Check whether the connections ( Page 8) are leaktight. 0 Installation and maintenance instructions ecofit pure 00030533_0

Installation 5 5.3 Connecting the drain line for the expansion relief valve s with other pipe work insulate the condensate discharge pipe to minimise any risk of freezing and beware when crossing cavities that the fall is maintained and the pipe sleeved. You can find further information in specification "S 6798" for installing and maintaining gas-fired boilers with a nominal heat loading under 70 kw. 5.5 Electrical installation Ensure that the pipeline is visible. The pipe must have a continuous fall and be routed to a position so that any discharge of water, possibly boiling, or steam cannot create any danger to persons, damage to property or external electrical components and wiring. The components must be set up in such a way that you can see the water flowing out. 5.4 Connecting the condensate drain pipework Danger! Risk of death from electric shock! The power supply terminals L and N remain live even if the product is switched off: Switch off the power supply. Secure the power supply against being switched on again. 5.5. Opening the electronics box Follow the instructions listed here and observe directives and local regulations on condensed water discharge. Use PVC or another material that is suitable for draining the non-neutralised condensed water. If you cannot guarantee that the materials from which the drain lines are made are suitable, install a system for neutralising the condensate. Note The condensate drain pipework must have a continuous fall (45 mm per metre) and should whenever possible terminate at a suitable drain point within the heated envelope of the building that will remain frost free under long periods of low external temperatures. Follow the instructions in the specified sequence. 5.5. Closing the electronics box Follow the instructions in the reverse order. Connect the condensate siphon (). Use the supplied drain hose () for this. Connect a condensate discharge pipe (.5 mm, not included in the scope of delivery) to the drain hose (). During installation remove all burs from inside of cut pipe work and avoid excessive adhesive which may trap small pockets of water close to the pipe wall which can freeze and build into a larger ice plug. 00030533_0 ecofit pure Installation and maintenance instructions

5 Installation 5.5.3 Cable route Power supply: Single-phase, 30 V, 50 Hz Fuse protection: 3 5. Open the electronics box. ( Page ) 6. Observe the routing of the power supply cable () in the electronics box in order to guarantee that there is no strain. 30 mm 4-V eus cable route 30-V eus cable route L N RT X 30V~ 5.5.4 Carrying out the wiring 30 mm max.. Shorten the connection cables to the appropriate lengths to prevent them from causing damage inside the electronics box.. Screw the plug to the connection cable. 3. Plug the plug into the slot provided on the PC. 5.5.5 Establishing the power supply 7. Carry out the wiring. ( Page ) 8. Close the electronics box. 9. Make sure that access to the mains connection is always available and is not covered or blocked. 5.5.6 Connecting controllers to the electronic system.off urner off 4 V US RT US RT US 4V = - + X06 urner off 4V= RT + US 3 X X X4. Observe all valid regulations.. Ensure that the rated mains voltage is 30 V. 3. Set up a fixed connection and install a partition with a contact opening of at least 3 mm (e.g. fuses or power switches). 4. Provide one common electricity supply for the boiler and for the corresponding controller: Safety thermostat for floor-standing heating 4 V controller. Open the electronics box. ( Page ). Carry out the wiring. ( Page ) 4 3 eus controller or radio receiver unit 4 Outside temperature sensor, wired Installation and maintenance instructions ecofit pure 00030533_0

Operation 6 3. Connect the individual components depending on the type of installation. Conditions: If installing a multi-circuit controller. Change the pump's operating mode d.8 from Eco (intermittently operating pump) to Comfort (continuously operating pump). Conditions: When connecting a controller (30 V). 6. Installer level overview S.3 Code 30 mm D.--- L N RT X 30V~ Connect the controller to the main plug. Remove the bridge from the plug 4V=RT. P.-- PF D F Conditions: 30 V 3-wire connection Ensure that the controller is designed for a maximum rated current of 7. Connect the controller to the main plug X. Terminal assignment: L line, N neutral conductor, earth Draw the operator's attention to the fact that the following features are present with this type of installation. The frost protection function is deactivated. If the product is installed in a room where there is a risk of frost and it has not been protected by a room thermostat, install an additional frost protection thermostat. The pump programmes are not active. If the product is switched off, the display is switched off. Each time the unit is started, the fan runs for 0 seconds. Residual heat in the heating return may result in the product blocking the burner for 0 minutes. 4. Close the electronics box. 6 Operation 6. Operating concept The operating concept and the display and setting facilities of the operator level are described in the operating instructions. n overview of the display and setting options in the installer level can be found in the section "Overview of the installer level". ( Page 3) --/-- DP 6.3 Calling up the installer level. Only call up the installer level if you are a competent person.. Press and ("i") at the same time. S.xx appears in the display (current unit status). 3. Press to access the installer level. Code and -- appear in the display. 4. Set the value 7 (code) and confirm by pressing. 5. Press to access the check programmes (P) and the fault codes (F) and to return to the diagnostics codes (D). 6. Use or to set the required value and confirm by pressing. 7. Confirm by pressing ( ). 8. Press to cancel a setting or exit the installer level. 6.4 Live Monitor (status codes) Menu Live monitor Status codes in the display provide information on the product's current operating status. Status codes Overview ( Page 3) 00030533_0 ecofit pure Installation and maintenance instructions 3

7 Start-up 6.5 Using check programmes Call up the installer level + x Display Meaning P.00 Purging check programme: The internal pump is cyclically actuated. The heating circuit and the hot water circuit are purged via the automatic air vent (the cap of the automatic air vent must be released). x : Start heating circuit purging x ( ): Start hot water circuit purging 3 x ( ): Restart heating circuit purging x (Cancel): End purge programme Note The purge programme runs for 7.5 min per circuit and then terminates. Purging the heating circuit: Diverter valve in heating position, actuation of internal pump for 9 cycles: 30 sec. on, 0 sec. off. Display: ctive heating circuit. Purging the hot water circuit: fter the above-mentioned cycles have run or the right-hand selection button has been pressed again: Diverter valve in the hot water position, actuation of the internal pump as above. Display: ctive hot water circuit. P.0 Maximum load check programme: fter successful ignition, the product is operated at maximum heat input. P.0 Minimum load check programme: fter successful ignition, the product is operated at minimum heat input. P.06 Filling mode check programme: 7 Start-up The diverter valve is moved to the mid-position. The burner and pump are switched off (to fill or drain the product). 7. Carrying out the initial start-up Initial start-up must be carried out by a customer service technician or an authorised competent person using the firstcommissioning-checklist. The first-commissioning-checklist in the appendix ( Page 40) of the installation instructions must be filled out and stored carefully along with the unit's documentation. Carry out the initial start-up using the first-commissioning-checklist in the appendix. Fill out and sign the first-commissioning-checklist. 7. Checking the type of gas Make sure that the product is set up correctly by checking the type of gas. This ensures optimum combustion quality. Check the type of gas as part of routine product maintenance work when replacing components or carrying out work on the gas route. 7.3 Checking the factory setting The product's combustion has been factory tested and is preset for operation with the gas group indicated on the identification plate. The product is only authorised to be operated with natural gas. Check the information about the type of gas indicated on the identification plate and compare this with the type of gas available at the installation location. Conditions: The product design is not compatible with the local gas group Do not start up the product. Conditions: The product design is compatible with the local gas group Proceed as described below. 7.4 Checking and treating the heating water/filling and supplementary water Caution. Risk of material damage due to poor-quality heating water Ensure that the heating water is of sufficient quality. efore filling or topping up the system, check the quality of the heating water. Checking the quality of the heating water Remove a little water from the heating circuit. Check the appearance of the heating water. If you ascertain that it contains sedimentary materials, you must desludge the system. Use a magnetic rod to check whether it contains magnetite (iron oxide). If you ascertain that it contains magnetite, clean the system and apply suitable corrosion-protection measures, or fit a magnet filter. Check the ph value of the removed water at 5 C. If the value is below 6.5 or above 8.5, clean the system and treat the heating water. Ensure that oxygen cannot get into the heating water. Checking the filling and supplementary water efore filling the system, measure the hardness of the filling and supplementary water. Treating the filling and supplementary water Observe all applicable national regulations and technical standards when treating the filling and supplementary water. 4 Installation and maintenance instructions ecofit pure 00030533_0

Start-up 7 Provided the national regulations and technical standards do not stipulate more stringent requirements, the following applies: You must treat the heating water in the following cases: If the entire filling and supplementary water quantity during the operating life of the system exceeds three times the nominal volume of the heating installation, or If the guideline values listed in the following table are not met, or if the ph value of the heating water is less than 6.5 or more than 8.5. Total heating output kw Water hardness at specific system volume ) 0 l/kw ppm CaCO₃ mol/ m³ > 0 l/kw 50 l/kw ppm CaCO₃ mol/ m³ > 50 l/kw ppm CaCO₃ < 50 < 300 < 3 00 0.0 > 50 to 00 > 00 to 600 mol/ m³ 00 50.5 0.0 50.5 0.0 0.0 > 600 0.0 0.0 0.0 ) Nominal capacity in litres/heating output; in the case of multiboiler systems, the smallest single heating output is to be used. Caution. The use of unsuitable heating water may cause aluminium corrosion and a resulting lack of leak-tightness. In contrast to steel, grey cast iron or copper, for example, aluminium reacts with alkaline heating water (ph value > 8.5) to produce substantial corrosion. When using aluminium, make sure that the ph value of the heating water is between 6.5 and a maximum of 8.5. Caution. Risk of material damage if the heating water is treated with unsuitable additives. Unsuitable additives may cause changes in the components, noises in heating mode and possibly subsequent damage. Do not use any unsuitable frost and corrosion protection agents, biocides or sealants. dditives for cleaning measures (subsequent flushing required) dey MC3+ dey MC5 Fernox F3 Sentinel X 300 Sentinel X 400 dditives intended to remain permanently in the system dey MC+ Fernox F Fernox F Sentinel X 00 Sentinel X 00 dditives for frost protection intended to remain permanently in the system dey MC ZERO Fernox ntifreeze lphi Sentinel X 500 If you have used the above-mentioned additives, inform the operator about the measures that are required. Inform the operator about the measures required for frost protection. 7.5 voiding danger arising from insufficient water pressure The filling pressure must be between 0.0 and 0.5 MPa (.0 and.5 bar). If the heating installation extends over several storeys, higher filling pressures may be required to avoid air entering the heating installation. If the water pressure falls below 0.05 MPa (0.5 bar), the value flashes in the display. If the water pressure falls below 0.03 MPa (0.3 bar), the product switches off. The display shows 0.0 MPa (0.0 bar). Fault F. is stored in the fault list. Top up the water in the heating installation to start up the product again. The pressure value flashes in the display until a pressure of 0.05 MPa (0.5 bar) or higher has been reached. 7.6 Switching on the product Switch on the product via the main switch installed onsite. No incompatibility with our products has been detected to date with proper use of the following additives. When using additives, follow the manufacturer's instructions without exception. We accept no liability for the compatibility of any additive or its effectiveness in the rest of the heating system. 00030533_0 ecofit pure Installation and maintenance instructions 5

7 Start-up 7.7 Filling and purging the heating installation 7.8 Filling the condensate siphon Preliminary work Flush the heating installation through. C 3. Check the silicone hose connection () between the pump's automatic air vent and the hydraulic console.. Remove the caps from the automatic air vents. 3. Fill with water until the required filling pressure is reached. Recommended filling pressure:.5 bar The heating and hot water functions cannot be activated. The pressure value flashes in the display until a pressure of 0.05 MPa (0.5 bar) or higher has been reached. n automatic air vent function is activated if the pressure exceeds 0.05 MPa (0.5 bar) for longer than 5 seconds. 4. Purge each radiator until the water escapes normally, and then retighten the system's purging valves. 5. Check that all connections are leak-tight. Conditions: If the noise persists in the boiler Purge the product again by activating check programme P.00.. Unclip the lower section of the siphon () from the upper section of the siphon ().. Remove the float (3). 3. Fill the lower section of the siphon with water up to 0 mm below the upper edge of the condensate drain pipework. 4. Re-insert the float (3). Note Check that the float is present in the condensate siphon. 5. Clip the lower section of the siphon () into the upper section of the siphon (). 7.9 Filling the hot water circuit. Open the water tap to fill the hot water circuit.. Close the water tap once the appropriate volume of water has flowed out. The hot water circuit is filled. 3. Check all connections and the entire system for leaktightness. 7.0 Checking the gas flow rate The gas flow rate has been set during production and does not require adjustment. With the front casing fitted check the gas flow rate of the boiler as follows: Start up the product with the check programme P.0. In addition, ensure that maximum heat can be dissipated into the heating system by turning up the room thermostat. Wait at least 5 minutes until the boiler has reached its operating temperature. Ensure that all other gas appliances in the property are turned off. Measure the gas flow rate at the gas meter. Compare the measured values with the corresponding values in the table. 6 Installation and maintenance instructions ecofit pure 00030533_0

Start-up 7 Qnw from the data plate H gas in m³/h Nom. +5% 0% 5.3.6.70.46 8.4.95.05.76 4.7.6.74.35 5.7.7.86.45 8.6 3.03 3.8.73 30.6 3.4 3.40.9 35.7 3.78 3.97 3.40 Conditions: Gas flow rate not in the permissible range Check all of the piping and ensure that the gas flow rates are correct. Only put the product into operation once the gas flow rates have been corrected. Conditions: Gas flow rate in the permissible range End the check programme P.0. llow the boiler to cool down by allowing pump overrun to operate for a minimum of minutes. Record the boiler maximum gas flow rate onto the enchmark gas boiler commissioning checklist. 7. Checking and adjusting the gas settings Only a qualified competent person is authorised to implement the settings on the gas valve. Each destroyed tamper-proof seal must be replaced. The CO adjusting screw must be sealed. Never modify the factory setting of the gas pressure regulator of the gas valve. 7.. Checking the gas connection pressure (gas flow pressure). Ensure that the gas inlet working pressure can be obtained with all other gas appliances in the property working.. Close the gas isolator cock (). 3. Undo the sealing screw on the measuring nipple (). 4. Connect a pressure gauge to the measuring nipple (). 5. Open the gas isolator cock (). 6. Start up the product with check programme P.0 (system with eus controller) or P.03 (system without eus controller). 7. In addition, ensure that maximum heat can be dissipated into the heating system by turning up the room thermostat. Permissible connection pressure Great ritain Natural gas G0.7 kpa (7.0 0 mbar) 9. Should the pressure recorded at the reference test point in the boiler be lower than indicated check if there is any blockage in the pipework or if the pipework is undersized. Conditions: Gas flow pressure not in the permissible range Caution. Risk of material damage and operating faults caused by incorrect gas connection pressure. If the gas connection pressure lies outside the permissible range, this can cause operating faults in and damage to the product. Do not make any adjustments to the product. Do not start up the product. If you cannot correct the failure, notify the gas supply company and proceed as follows: End check programme P.0. llow the boiler to cool down by allowing pump overrun to operate for a minimum of two minutes. Close the gas isolator cock. Remove the pressure gauge and retighten the sealing screw () for the measuring nipple. Open the gas isolator cock (). Check the measuring nipple for gas tightness. Close the gas isolator cock (). Install the front casing. ( Page 9) Disconnect the product from the power mains. You must not start up the boiler. Conditions: Gas flow pressure in the permissible range End the check programme P.0. llow the boiler to cool down allowing pump overrun to operate for a minimum of two minutes. Close the gas isolator cock (). Remove the pressure gauge and retighten the sealing screw () for the measuring nipple. Open the gas isolator cock (). Check the measuring nipple for gas tightness. Install the front casing. ( Page 9) Reset boiler controls for normal operation. Record the appliance gas inlet working pressure (kpa resp. mbar) in the enchmark gas boiler commissioning checklist. 8. With the boiler operating at full load check that the gas inlet working pressure at the reference test point () complies with the requirements. 00030533_0 ecofit pure Installation and maintenance instructions 7

8 dapting the unit to the heating installation 7.. Checking the leak-tightness of the flue gas installation and flue gas recirculation. Check the flue gas installation is intact in accordance with the latest gas safe technical bulletin and information supplied in the installation instructions.. For extended flue gas installations check for flue gas recirculation using the air analysis point. 3. Use a flue gas analyser. 4. If you discover CO or CO in the supply air, search for the leak in the flue gas installation or for signs of flue gas recirculation. 5. Eliminate the damage properly. 6. Check again whether the supply air contains any CO or CO. 7. If you cannot eliminate the damage, do not start up the product. 7..3 Thoroughly flushing the heating installation ("hot"). Operate the appliance until the boiler and the heating system are up to temperature.. Check the heating system for leaks. 3. Connect a hose to the drain valve located at the lowest position of the heating system. 4. Shut off the boiler, open the drain valve and all purge valves on the radiators and allow the water to flow out of the heating system and the boiler quickly and fully. 5. Close the drain valve. 6. Fill and purge the heating installation. ( Page 6) 7. Re-fill the system until the system design pressure of 0, MPa (,0 bar) is attained. Note The actual reading on the digital pressure gauge should ideally be 0,05 MPa (0,5 bar) plus an additional pressure corresponding to the highest point of the system above the base of the boiler 0 m head equals an additional bar reading on the pressure gauge. The minimum pressure should not be less than 0, MPa ( bar) in any installation. If the system is to be treated with an inhibitor it should be applied at this stage in accordance with the manufacturer s instructions. Further information can be obtained from Sentinel, etz Dearborn Ltd., Tel: 05 40 9595, or Fernox, lpha Fry technologies. Tel: 0870 870036. 8. Install the front casing. ( Page 9) 7..4 Checking the CO₂ content. Start up the product with check programme (P.0).. Wait until the value that is read is stable. Waiting period for reading a stable value: 5 min 3. Unscrew the cover from the flue gas analysis point (). 4. Measure the CO₂ content at the flue gas analysis point (). 5. Compare the measured value with the corresponding value in the table. Checking the CO₂ content Great ritain Removed front casing/installed front casing Natural gas G0 9. ± % The value is OK. The value is not OK; you cannot start up the product. Inform Customer Service. 7. Checking leak-tightness Check the gas pipe, the heating circuit and the hot water circuit for leak-tightness. Check that the air/flue pipe has been installed correctly. Conditions: Room-sealed operation Check whether the vacuum chamber has been sealed so that it is leak-tight. 7.. Checking the heating mode. ctivate the heating mode on the user interface.. Turn all thermostatic radiator valves on the radiators until they are fully open. 3. llow the product to operate for at least 5 minutes. 4. Fill and purge the heating installation. ( Page 6) 5. Call up the status codes. ( Page 3) Status codes Overview ( Page 3) If the product is working correctly, the display shows S.04. 8 dapting the unit to the heating installation You can reset/change the system parameters. Overview of diagnostics codes ( Page 8) 8 Installation and maintenance instructions ecofit pure 00030533_0

dapting the unit to the heating installation 8 8. urner anti-cycling time To prevent frequent switching on and off of the burner and thus prevent energy losses, an electronic restart lockout is activated for a specific period each time the burner is switched off. The burner anti-cycling time is only active for the heating mode. Hot water handling mode during a burner anti-cycling time does not affect the time function element. 8.. Setting the burner anti-cycling time. Navigate to diagnostics code D.00 in the installer level and confirm by pressing.. Set the burner anti-cycling time and confirm by pressing. T Flow (target) [ C] Set maximum burner anti-cycling time [min] 5 0 5 0 5 30 30.0 4.0 8.5.5 6.5 0.5 5.0 35.0 4.0 7.5.0 5.0 8.5.0 40.0 3.5 6.5 0.0 3.0 6.5 9.5 45.0 3.0 6.0 8.5.5 4.0 7.0 50.0 3.0 5.0 7.5 9.5.0 4.0 55.0.5 4.5 6.0 8.0 0.0.5 60.0.0 3.5 5.0 6.0 7.5 9.0 65.0.5.5 3.5 4.5 5.5 6.5 70.0.5.0.5.5 3.0 3.5 75.0.0.0.0.0.0.0 T Flow (target) [ C] Set maximum burner anti-cycling time [min] 35 40 45 50 55 60 30 9.0 33.0 37.0 4.0 45.0 49.5 35 5.5 9.5 33.0 36.5 40.5 44.0 40.5 6.0 9.0 3.0 35.5 38.5 45 9.5.5 5.0 7.5 30.5 33.0 50 6.5 8.5.0 3.5 5.5 8.0 55 3.5 5.0 7.0 9.0 0.5.5 60 0.5.5 3.0 4.5 5.5 7.0 65 7.0 8.0 9.0 0.0.0.5 70 4.0 4.5 5.0 5.5 6.0 6.5 75.0.0.0.0.0.0 8. Setting the pump output The product is equipped with a speed-regulated high-efficiency pump, which adjusts independently to the hydraulic conditions of the heating installation. If you have installed a low loss header in the heating installation, you should switch off the speed regulation and set the pump output to a fixed value. If required, change the setting of the pump speed, which depends on the operating mode, under diagnostics code d.4. Overview of diagnostics codes ( Page 8) 8.. Pump diagrams s: 350 300 50 00 50 00 50 0 0 00 400 600 800 000 5s: 350 300 50 00 50 00 50 Remaining feed head [mbar] Flow rate [l/h] Max. PWM Min. PWM 0 0 00 400 600 800 000 00 8.. Resetting the remaining burner anti-cycling time Press. Remaining feed head [mbar] Flow rate [l/h] Max. PWM Min. PWM 8s: 00030533_0 ecofit pure Installation and maintenance instructions 9

8 dapting the unit to the heating installation 350 300 50 00 50 00 50 0 5s: 0 00 400 600 800 000 00 Remaining feed head [mbar] Flow rate [l/h] Max. PWM Min. PWM 450 400 350 300 50 00 50 00 50 0 0 00 400 600 800 000 00 8.3 Setting the bypass valve Caution. Risk of material damage caused by incorrect setting of the high-efficiency pump If the pressure at the bypass valve is increased (by turning it clockwise) and the pump output is set to less than 00%, the product may not operate correctly. In this case, set the pump output to 5 = 00% using diagnostics parameter d.4. Conditions: d.4 is set to 0 = auto Do not change the factory settings. Conditions: d.4 is set to - 5 Remove the front casing. ( Page 9) Remaining feed head Max. PWM [mbar] Flow rate [l/h] Min. PWM 30s: 400 350 300 50 00 50 00 50 0 0 500 000 400 Remaining feed head Max. PWM [mbar] Flow rate [l/h] Min. PWM Regulate the pressure using the adjusting screw (). Position of the adjusting screw Right-hand stop (screwed all the way in) Mid-position (six anticlockwise rotations) Notes/application If the radiators do not heat up sufficiently at the default setting. In this case, you must set the pump to the maximum speed. Default setting Five further anti-clockwise If noises are produced in the rotations starting from the radiators or radiator valves. mid-position Install the front casing. ( Page 9) 8.4 Setting the hot water temperature Danger! Risk of death from Legionella. Legionella multiply at temperatures below 60 C. Ensure that the operator is familiar with all of the nti-legionella measures in order to comply with the applicable regulations regarding legionella prevention. Set the hot water temperature. 0 Installation and maintenance instructions ecofit pure 00030533_0

Handing the product over to the operator 9 Conditions: Water hardness: > 3.57 mol/m³ Hot water temperature: 50 9 Handing the product over to the operator When you have finished the installation, attach the sticker supplied (in the operator's language) to the product cover. Explain to the operator how the safety devices work and where they are located. Inform the operator how to handle the product. In particular, draw attention to the safety information which the operator must follow. Inform the operator of the necessity to have the product maintained on a regular basis. Instruct the operator about measures taken to ensure the supply of combustion air and flue gas pipe. 0 Troubleshooting 0. Rectifying faults If fault messages (F.xx) appear, rectify the fault after referring to the table in the appendix or using the check programmes. ( Page 4) Overview of fault codes ( Page 3) If several faults occur at the same time, the display shows the corresponding fault messages for two seconds each in alternation. Press (max. three times) to restart the product. If you are unable to remedy the fault and the fault recurs despite fault clearance attempts, contact customer service. 0. Calling up and clearing the fault memory The last 0 fault messages are stored in the fault memory. Call up the installer level. ( Page 3) Navigate to the fault codes. The number of faults that have occurred is shown in the display and the faults that are currently called up are displayed with their fault numbers F.xx. Press or to call up individual fault messages. To delete the entire fault list, navigate to diagnostics code D.094 in the installer level. Set the diagnostics code to, and confirm by pressing. 0.3 Resetting parameters to factory settings. Navigate to diagnostics code D.096 in the installer level.. Set the diagnostics code to, and confirm by pressing. 0.4 Preparing the repair work. Switch off the product.. Disconnect the product from the power mains. 3. Remove the front casing. 4. Close the gas isolator cock. 5. Close the service valves in the heating flow and in the heating return. 6. Close the service valve in the cold water pipe. 7. Drain the product if you want to replace water-bearing components of the product. 8. Ensure that water does not drip on live components (e.g. the electronics box). 9. Use only new seals and O-rings. Do not use any additional sealing materials. 0.5 Replacing defective components 0.5. Replacing the burner. Remove the gas-air mixture unit. ( Page 5). Remove the two burner seals. 3. Remove the burner. 4. Insert the new burner. 5. Insert two new burner seals in the burner cover. 6. Install the gas-air mixture unit. ( Page 6) 0.5. Replacing the gas-air mixture unit. Remove the gas-air mixture unit. ( Page 5). Install the new gas-air mixture ( Page 6). 0.5.3 Replacing the heat exchanger. Remove the front casing. ( Page 9). Remove the gas-air mixture unit. ( Page 5) 3. Remove the gas pipe (). 00030533_0 ecofit pure Installation and maintenance instructions