Conventional Audible Visual Range

Similar documents
CONVENTIONAL AUDIBLE VISUAL

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Fire Signalling. Signalling Solutions

AP200 SERIES INTELLIGENT ALARM DEVICES

EN54-23 Beacons & Sounder Beacons

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

ELECTRONIC SOUNDER STROBE Model : AVD-C407

AP200 SERIES INTELLIGENT ALARM DEVICES

EFBW series - BiWire Ultra control panel

Evacuate everyone Sonos Pulse & Nexus Pulse

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Intellia Sounder Bases and Sounder Beacon Bases

XP95 Sounder VAD Base

Conventional Fire Detection

Fire Signalling. Signalling Solutions

SOUNDER BASES AND SOUNDER BEACON BASES

Fire Signalling. Signalling Solutions

Half-Dome. the Design-Tower. Compact

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

Intelligent Security & Fire Ltd

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Sonos-SB Siren/Beacon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Xenex Conventional Fire Detection & Alarm System

Emergi-Lite Orbis detectors

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Addressable Loop Powered Visual Alarm Devices

FlexSQUARE Square shaped beacons

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Contents. Morley-IAS by Honeywell. Providing a control panel solution for fire industry professionals.

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

X10 Mini, Midi & Maxi

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Addressable Fire Alarm Devices Superior Technology for the Highest Protection

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Industrial Signalling

Industrial Signalling. Signalling Solutions

The complete conventional fire warning system

INSTRUCTION & SERVICE MANUAL

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Installation Guide. Ceiling PIR Detector (311) Features and Connections

TrueAlert Notification Appliances

SOUNDER WITH BEACON FOR FIRE DETECTION PANEL

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

L-Series, Indoor Strobes and Horn Strobes

Analogue addressable devices

L-Series, Indoor Strobes and Horn Strobes

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Fire Products Catalogue

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Sonos Sounder Beacon (DC)

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

4 wire conventional alarm system

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

TrueAlert Multi-Candela Notification Appliances

Public Address and Voice Alarm. Version 1 DESIGN & INSTALLATION GUIDE

Quick Selection Guide Fire Systems LSN Periphery

Series M22 Signaling Beacons and Alarms

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Installation Instruction Venturi-Air Duct Kit. (Part No. S )

TrueAlert Multi-Candela Notification Appliances

Intelligent addressable fire alarm control panel

MINERVA MZX125 Digital Addressable Fire Detection System

ATEX. IECEx. culs GOST-R. VdS

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

CONTENTS NBM-06 Bell (6") Page 1

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

Fire Systems Design Pocket Guide BS 5839 Part 1:2017 and CoP 0001 for Visual Alarm Devices. Fire Installers Mate. A guide to fire system design

TrueAlert Addressable Notification Appliances

Genesis LED G1 Series

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Conventional Fire Alarm System 2014 V1.2

L-Series, Emergency Communication Devices

Optical-Audible Signal Devices

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Signature Series Auto-Sync Output Module (CC1S)

A Guide To BS Understanding the selection, spacing and siting of detectors

INPUT / OUTPUT MINI MODULES

Industries. As a premier global manufacturing company, we believe that great brands are

Solution F2. Fire Alarm Control Panels one step ahead.

YO3 - YO4 / YL4 - YO5 / YL5

Evolution Analogue Addressable Fire System

Potter Wall Mount Select-A-Strobe

Product Manual Standard Asserta Sounder Range

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Addressable and Conventional Fire Protection

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

Pilot devices Stacklights Signal beacons

Transcription:

Conventional Audible Visual Range

Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC and are optimised for use in 12V and 24V systems, making them suitable for use in both fire and security applications. The conventional range of detector base sounders are available in a standard 4 tone version in white with locally controllable output levels to enable the sound intensity to be adjusted to suit the application. The detector base sounders are suitable for fire detectors with 60mm mounting centres. The sounders can also be fitted with a red or white lid in place of a fire detector, enabling them to be positioned vertically on the wall. This arrangement provides an extremely low profile unit which is unobtrusive and protrudes only 35mm from the wall. The distinctive low profile shape is acoustically very efficient, producing an omni-directional high sound output at low current levels. Rugged construction with solid state electronics also provides high reliability and stable performance. All wall mount sounder products ensure full compliance as they are designed and approved to EN54-3 and also CPD (Construction Products Directive) approved. FEATURES & BENEFITS 4 Tone Sounder High sound output, low current consumption High reliability and stable performance Volume control Lid accessory available to enable vertical installation Designed and approved to EN54-3 Market specific tone set available

Dimensions Ø117 35 54 38 Technical Specifications ELECTRICAL Operating Voltage Sound Output ENVIRONMENTAL Operating Temperature Relative Humidity Ingress Protection MECHANICAL Diameter Depth Colour Weight Material Cable Termination Gross Weight First Fix option: 9 to 33VDC (Approved to 10-14V and 21-27V) Up to 92db(A) @1m -25oC to 70oC (with sealing kit) Up to 96% @ 55oC IP24D 117mm 35mm White 220g PC/ABS 0.5-2.5mm2 (low profile) 200g (deep / IP65) 207g ORDER CODES Model Description Colour DBSLIDW Cover plate for NBS4 ceiling mounting sounder. Pack of 10 White NBS4 Ceiling mounting base sounder, four tone (white), no cover. If required the DBSLIDW (white) lid to be ordered separately. White Honeywell 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 www.honeywell.com Base Sounder Rev 1 MB 03/16 2016 Honeywell International Inc.

Visual Alarm Devices Non-Addressable Audible Visual Alarm Devices Beacons EN54-23 Approved VADs Honeywell s Non-Addressable beacons feature high output LEDs, advanced optics and an innovative lens design, providing outstanding Omni-directional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23, the beacon delivers outstanding quality, reliability and long operational life. F E AT U R E S & B E N E F I T S Simple, Fast, Flexible Installation Quality & Reliability Omni-directional light coverage eliminates need for device orientation. Independently approved to all required standards: Deep base option with multiple cable entries for flexible installation. Designed with full range of common fixing centres. >>Manufacturing: Construction Products Regulation (CPR) >>Product performance: EN54-23 C & W categories. >>Environmental: RoHS, WEEE Positive fit engagement and feedback of base with device for easy installation. Product range supports system approval. Universal Device The requirements of EN54-23 Suitable for wall and ceiling mount applications. A cube or cylinder of light with a Range of installation and base options, for indoor and applications up to IP65. minimum of 0.4 Lumens/m2 Operates on 12V and 24V systems, making the range suitable for fire & security applications. * X & Y dimensions are defined by the device manufacturer Outstanding Performance Approved to EN54-23, C & W categories. Advanced optics ensures superior light coverage at low current draw. Synchronised flash exceeds EN54-23 standard. Choice of white or red light flash options. Soft start feature reduces power surges during system start-up. 3 23

Beacons Technical Specifications Introducing the Range DEVICE APPROVALS BODY COLOUR FLASH COLOUR LENS COLOUR ENVIRONMENTCOMPLIANCE Beacon EN54-23 C & W Class Red Red White Clear RoHS/WEEE Technical Specifications ELECTRICAL Operating Voltage EN54-23 Average Current Consumption ENVIRONMENTAL 12 to 29VDC 26mA @ 29VDC Operating Temperature -25 C to 70 C Relative Humidity Ingress Protection MECHANICAL Dimensions (diameter x depth) Gross Weight Standard device Gross Weight First Fix option Body Colour Cable Terminal Size Material 93% ±3% non condensing IP21C low profile base IP65 deep base 100mm x 72mm low profile base 100mm x 97mm deep base (low profile) 164g (deep / IP65) 171g (low profile) 174g (deep / IP65) 181g Red 0.5-2.5mm² (lens) PC (body) PC/ABS Dimensions Wiring Options

Beacons Technical Specifications Product Performance BEACON WALL MOUNT W CLASS WALL MOUNT W CLASS CEILING MOUNT C CLASS CEILING MOUNT C CLASS Flash Colour White Red White Red EN54-23 coverage volume code W-2.4-9.0 W-2.4-6.2 C-3-9.5 / C-6-9.5 / C-9-9.5 C-3-9.4 / C-6-8.6 Installation height (X) 2.4m 2.4m 3m / 6m / 9m 3m / 6m EN54-23 coverage (Y) Cube YY = 9.0m Cube YY = 6.2m Cylinder Ø = 9.5m Cylinder Ø = 9.4 / 8.6m EN54-23 coverage volume 194m³ 92m³ 213m³ / 425m³ / 638m³ 208m³ / 348m³ Flash rate 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz Operating voltage range 12 to 29 V 12 to 29V 12 to 29V 12 to 29V Synchronisation Automatically on power up, exceeds EN54-23 standard Accessories LOW PROFILE BASES DEEP BASES IP AND EARTHING KITS CSR Red low profile base, pack of 5 CWR Red deep / IP65 base, pack of 5 PS189 Deep base gasket, pack of 5 CSW White low profile base, pack of 5 CWR White deep / IP65 base, pack of 5 PS188 Deep base O Ring, pack of 5 SC076 Earth strap, pack of 5 PRODUCT RANGE CWST-RW-S5 CWST-RW-W5 CWST-RR-S5 CWST-RR-W5 White flash EN54-23 W and C class approved strobe with clear lens and red body. Low profile base included. White flash IP65 deep base EN54-23 W and C class approved strobe with clear lens and red body. Deep base included. Red flash EN54-23 W and C class approved strobe with clear lens and red body. Low profile base included. Red flash IP65 deep base EN54-23 W and C class approved strobe with clear lens and red body. Deep base included. Honeywell 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 www.honeywell.com B EN54-23 Rev 1 MB 03/16 2016 Honeywell International Inc.

Visual Alarm Devices Non-Addressable Audible Visual Alarm Devices Sounder Beacons EN54-23 Approved VADs Honeywell s Non-Addressable Sounder Beacon is ideal for applications where a dual purpose audible and visual alarm device is required. The product features a new folded horn design, high output LEDs, advanced optics and an innovative lens design, providing outstanding sound output and omni-directional light coverage at low current draw. Specifically designed and approved to meet both EN54-3 and EN54-23, the Sounder Beacon delivers outstanding quality, reliability and extended operational life. F E AT U R E S & B E N E F I T S Simple, Fast, Flexible Installation Universal Device Omni-directional light coverage eliminates need fordevice orientation. Tailor made range; selection according to EN54-23 C & W categories. Deep base option with multiple cable entries for flexible installation. Suitable for wall and ceiling mount applications. Designed with full range of common fixing centres. Positive fit engagement and feedback of base with device for easy installation. Outstanding Performance Approved to EN54-3 and EN54-23, C & W categories. Global tone set: 32 tones including a new bell tone. Range of installation and base options, for indoor and applications up to IP65. Operates on 12V and 24V systems, making the range suitable for use in fire & security applications. 32 tones all approved to EN54-3. The requirements of EN54-23 Advanced optics ensure superior light coverage. A cube or cylinder of light with a Synchronised flash exceeds EN54-23 standard. Choice of white or red light flash options. Soft start feature reduces power surges during system start-up. Quality & Reliability Independently approved to all required standards: >>Manufacturing: Construction Products Regulation (CPR) >>Product performance: Light output: EN54-23 C & W categories; Sound output: EN54-3. Environmental: RoHS, WEEE. minimum of 0.4 Lumens/m2 * X & Y dimensions are defined by the device manufacturer 33 23 23

Sounder Beacons Technical Specifications Introducing the Range DEVICE Sounder Beacon APPROVALS BODY COLOUR FLASH COLOUR LENS COLOUR EN54-23 EN54-3 RED WHITE RED WHITE CLEAR W & C Class ENVIRONMENT COMPLIANCE RoHS/WEEE Technical Specifications ELECTRICAL Operating Voltage Operating Voltage Approved 12 to 29VDC EN54-23 @12 to 29 VDC (C & W) EN54-3 @ 9-14 VDC & 18-29VDCt Current Consumption, Average 49mA @ 29VDC (W Class) Tone 7 ENVIRONMENTAL Operating Temperature -25 C to 70 C Relative Humidity Ingress Protection MECHANICAL Body Colour 93% ±3% non condensing IP21C low profile base IP65 deep base Red / White Sound Output, Maximum 107db(A) @1m (Tone 23)t Number of Tones Volume Setting Cable Termination Size Material Lens / Body Gross Weight Standard device Gross Weight First Fix option 32 includes a bell tone (Full tone table available on website & manual installation) High or medium 0.5-2.5mm² Flame retardant PC/ABS (low profile) 271g (deep / IP65) 280g (low profile) 283g (deep / IP65) 293g Dimensions

Sounder Beacons Technical Specifications Wiring Options Product Performance BEACON WALL MOUNT W CLASS WALL MOUNT W CLASS CEILING MOUNT C CLASS CEILING MOUNT C CLASS Flash Colour White Red White Red EN54-23 coverage volume code W-2.4-8.9 W-2.4-6.2 C-3-10 / C-6-10 C-3-8.9 / C-6-8.2 Installation height (X) 2.4m max 2.4m max 3m / 6m 3m / 6m EN54-23 coverage (Y) Cube YY = 9.0m Cube YY = 6.2m Cylinder Ø = 9.5m Cylinder Ø = 9.4 / 8.6m EN54-23 coverage volume 190m³ 86m³ 236m³ / 471m³ 187m³ / 317m³ Flash rate 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz Operating voltage range 12 to 29 V 12 to 29V 12 to 29V 12 to 29V Synchronisation Synchronisation Automatically on power on, meets EN54-3 and exceeds EN54-23 standard Accessories LOW PROFILE BASES DEEP BASES IP AND EARTHING KITS CSR Red low profile base, pack of 5 CWR Red deep / IP65 base, pack of 5 PS189 Deep base gasket, pack of 5 CSW White low profile base, pack of 5 CWR White deep / IP65 base, pack of 5 PS188 Deep base O Ring, pack of 5 SC076 Earth strap, pack of 5 PRODUCT RANGE CWSS-RW-S5 CWSS-RW-W5 CWSS-RR-S5 Red body with white flash EN54-Pt.3 and Pt.23 W and C class approved sounder strobe with clear lens. Low profile base included. Red body with white flash, IP65 deep base, EN54-Pt.3 and Pt.23 W and C class approved sounder strobe with clear lens. Deep base included. Red body with red flash EN54-Pt.3 and Pt.23 W and C class approved sounder strobe with clear lens. Low profile base included. CWSS-RR-W5 Red body with red flash, IP65 deep base, EN54-Pt.3 and Pt.23 W and C class approved sounder strobe withclear lens. Deep base included. CWSS-WW-S5 CWSS-WW-W5 White body with white flash EN54-Pt.3 and Pt.23 W and C class approved sounder strobe with clear lens. Low profile base included. White body with white flash, IP65 deep base, EN54-Pt.3 and Pt.23 W and C class approved sounder strobe with clear lens. Deep base included.

Honeywell 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 www.honeywell.com SB EN54-23 Rev 1 MB 03/16 2016 Honeywell International Inc.

Visual Devices Non-Addressable Audible Visual Devices Sounders Honeywell s Non-Addressable sounder is a high quality device designed to alert building occupants of an emergency. The product features a new folded horn design which provides outstanding sound output at low current draw. With its modern design, global tone set and extensive installer-friendly features, the sounder is the logical choice for specifiers, installers and distributors. F E AT U R E S & B E N E F I T S Simple, Fast, Flexible Installation Universal Device Modern design eliminates need for device orientation. Suitable for wall and ceiling mount applications. Deep base option with multiple cable entries for flexible installation. Designed with full range of common fixing centres. Positive fit engagement & feedback of base with device for easy installation. Global tone set: 32 tones including a new bell tone. Range of installation and base options, for indoor and applications up to IP65. Optimised for 12V and 24V systems, making the range suitable for use in fire & security applications. Outstanding Performance Quality & Reliability Approved to EN54-3. Independently approved to all required standards: Superior sound output and low current consumption. >>Manufacturing: Construction Products Regulation (CPR) 32 tones all approved to EN54-3. >>Product performance: EN54-3. Adjustable volume settings. >>Environmental: RoHS, WEEE Two stage sounders enable alert and alarm sequences to be set for phased evacuation. Synchronised sound output. Product range supports system approval. 3 23

Sounders Technical Specifications Introducing the Range DEVICE APPROVALS BODY COLOUR BASE OPTIONS ENVIRONMENT COMPLIANCE Beacon EN54-3 Red White Low Profile or Deep/IP65 RoHS/WEEE Technical Specifications ELECTRICAL Operating Voltage 9 to 29VDC (Approved to EN54-3 @ 9-14V and 18-29V) Average Current Consumption 31mA @ 29VDC (Tone 8) Maximum Sound Output 107dB (A) @ 1m (Tone 23) ENVIRONMENTAL Operating Temperature -25 C to 70 C Relative Humidity 93% ±3% non condensing Ingress Protection IP21C low profile base IP65 deep base MECHANICAL Body Colour Number of Tones Volume Setting Cable Termination Size Material Gross Weight Standard device: Gross Weight First Fix option: Red / White 32 includes a bell tone (Full tone table available on website & installation manual) High or medium 0.5-2.5mm² Flame retardant PC/ABS (low profile) 190g (deep / IP65) 197g (low profile) 200g (deep / IP65) 207g Dimensions

Sounders Technical Specifications Wiring Options Accessories LOW PROFILE BASES DEEP BASES IP AND EARTHING KITS CSR Red low profile base, pack of 5 CWR Red deep / IP65 base, pack of 5 PS189 Deep base gasket, pack of 5 CSW White low profile base, pack of 5 CWR White deep / IP65 base, pack of 5 PS188 Deep base O Ring, pack of 5 SC076 Earth strap, pack of 5 PRODUCT RANGE CWSO-RR-S1 CWSO-RR-W1 CWSO-WW-S1 Red EN54-3 approved low profile wall and ceiling mount sounder. Low profile base included. Red IP65 deep base wall and ceiling mount sounder. Deep base included. White EN54-3 approved low profile wall and ceiling mount sounder. Low profile base included. Honeywell 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 www.honeywell.com Sounders Rev 1 MB 03/16 2016 Honeywell International Inc.