IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM

Similar documents
An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction

COMMON SENSE APPROACH TO OPERATING DRY KILNS WHEN BOILER CAPACITY IS LIMITED. William Brubaker Wellons, Inc. Sherwood, Oregon.

A: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance.

STEAM AND TRAP FUNDAMENTALS

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

Armstrong Cool-Fog Systems

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Understanding Water Use by Plants in a Cloche System - Gardening

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

Using Fire Extinguishers. Leaders Guide and Quiz

HEAT EXCHANGER FORMULAS & EXAMPLE

A Treatise on Liquid Subcooling

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

CHAPTER 3 BASIC STEAM CYCLE

Wrangler JK Engine Cooling

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

THE BENEFITS FROM ELIMINATING ROOF VENTING IN DRY KILNS

DELTA T AND YOUR LUMBER DRYING OPERATIONS

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

HVAC/R Refrigerant Cycle Basics

"USING FIRE EXTINGUISHERS"

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Hoffman Specialty General Catalog

A M E M B E R O F T H E K E N D A L L G R O U P

Energy Management and Controls

KILN HEATING AND CONDENSATE HANDLING SYSTEMS

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Improving Dryer Efficiency

Steam Trap Inspection Methods And Steam Cost Analysis

How to Trap: Process Air Heaters

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Accomplish Maximum Green Results in Commercial Buildings #

What Is Liquid Subcooling?

INDUSTRIAL DEHUMIDIFICATION DRYING OF SOFTWOODS

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E.

How to Trap: Trap Selection and Safety Factors

PACKAGED COMMERCIAL WATERTUBE BOILERS

Steam Trap Selection

Thermal Efficiency Gas-Fired High Efficiency Unit Heater

WATER HAMMER something that never should occur in a steam system

TANKLESS WATER HEATER HEATING SOLUTIONS

INFRARED 101 How Does It Work and Will It Make You Money?

SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

R2 August General Laundry Planning Guide

Natural Concept Landscape Co., Inc C SR9 SE Snohomish, WA Office-(360)

MINTRAC MEAT INDUSTRY ENVIRONMENT CONFERENCE WASTE HEAT RECOVERY FROM RENDERING PLANTS PRESENTED BY DEREK HENDERSON

Size of central air conditioner for 1200 square feet

Boilers and Water Heating Rebate Catalog Saving energy for a brighter future.

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Ohio Energy. Workshop HH. Strategies & Technologies to Improve the Boiler Room Efficiency. Wednesday, February 21, p.m. to 3:15 p.m.

RADON LAZERWEB SERVICES

compressed air or left to consume air even when the associated production machine has been turned off.

CONDEXA PRO EXCELLENCE AND VERSATILITY

How to Trap: Steam Tracer Lines

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam System Best Practices Document No. 11

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

Reputation Management: A Guidebook

RULE 3.23 NATURAL GAS-FIRED WATER HEATERS, SMALL BOILERS, AND PROCESS HEATERS (Adopted 10/03/2016)

COMMERCIAL CONDENSING BOILER OPTIMIZATION

Crushing Principles of Mechanical Crushing

How to Trap: Rotating Dryers Requiring Syphon Drainage

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Cost, time and water savings gained through optimized tank cleaning

Heating Efficiency Program COLORADO

Evaporation in the Desert

Prescriptive Program Rebate Application

d. Portable water heaters used exclusively for underwater diving operations.

Use this Construction/HVAC Glossary to answer the questions below.

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Summary of 60-Day Notice: Heating Efficiency

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

Energy: Synthesis and Analysis

Expansion Tank Design (Hydronic Hot Water)

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Grain and Soybean Drying on Georgia Farms

.03 ATMOSPHERIC DEAERATOR

SERVICE ASSISTANT OVERVIEW FDSI Online Training

CONTENTS. Air Conditioning Fundamentals TC S

PUSHING THE LIMITS OF WHAT IS POSSIBLE

Commercial. Phoenix. Advanced Heating & Hot Water Systems. 96% Efficient Commercial Water Heater

SEVEN STEPS TO EFFECTIVE PRE- SEASON COOLING CHECKUPS

Cost of a Thanksgiving Meal

English as a Second Language Podcast ESL Podcast 168 The Home Improvement Store

Improved Dryer Control

What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

Steam: Yesterday, Today and Tomorrow The Use of Steam as an Efficient Heat Source

DISTRIBUTION SYSTEMS. Water Piping and Pumps

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

How to Trap: Troubleshooting

Commercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

Transcription:

IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM Dave Walker Patti Lowe Matrix Northwest Portland, Oregon Introduction Thank you for being here to find out about permanent fixed orifice systems. I want to thank Angus at Hampton Lumber for his role in having us on the agenda and for all the help he has given us this past year. My company, Matrix Northwest is the West Coast distributor for Enercon Systems. Today I will be discussing how fixed orifice steam traps improve fuel efficiency, heat transfer and drying consistency. We are going to break this session into two topics followed by a question and answer period, which will be led by Dave Walker and Dean Trytten who is one of Enercon's representatives on the East Coast. Please hold your questions until the Q&A so I can get through all the information. Angus Low from Hampton Lumber is also available to answer questions. Hampton converted 6 plants within the past year. I'll pass around a couple of fixed orifices for you to look at while I'm talking. There are a dozen kiln plants on the West Coast that have completely converted their plants to orifices, and this has occurred within the last year. Enercon is converting about one kiln plant a week now in your industry. Topic 1 Inconsistent Drying One of the things we see when we visit kiln companies is inconsistent drying. For example: the wood at the top of the kiln is dry while the wood at the bottom is wet. Topic 2 Orifices and Varying Loads But before I talk more about how orifices improve drying consistency, let me ask you: How many of you have heard that orifices don't work with variable loads? How many of you have variable loads? All plants have varying loads, and all loads vary if orifices couldn't handle a varying load they wouldn't be around. In your industry you may dry different types of wood, have different schedules, have different cuts of wood, your condensate loads will vary within a load cycle, and so forth. A little later in the presentation, I'll illustrate how modulating control valves allow orifices to work with varying loads in all of your applications. Western Dry Kiln Association 57 May 2004

Plant Overview Screen Getting back to inconsistent drying. I'm sure you've all experienced problems with inconsistent drying in your kilns. What you're experiencing is inconsistencies in the heat transfer in your coils. In Figure 1, red indicates hotter temperatures and blue indicates colder temperatures. On the top is an illustration of what happens in a typical plant using mechanical traps. Mechanical traps produce inconsistent temperatures, where heat transfer capability at the bottom of the coil is lower than the heat transfer capability at the top of the coil. Orifices dramatically reduce that problem. The bottom illustration shows the same plant with a properly-sized orifice system. Orifices allow for consistent heat transfer throughout the plant. Let's look at what's happening at the coil level. Typical Center Coils WI Modulating Control Valve When closed - holds back water When open - drains off water, but also release steam Is always open to condensate The heat transfer rate is more consistent from top to bottom w/ orifice Figure 1. Typical Center Coils with Modulating Control Valve Western Dry Kiln Association 58 May 2004

Comparison of Two Coils Coil w/ Mechanical Trap: When mechanical traps are closed, they are holding back flow. The coil is still radiating heat so you have a reduction in energy-to-pound mass. The results of that energy-to-pound mass reduction is water. Water is an insulator that restricts heat transfer. Effectively the mechanical traps have shrunk the usable area of the coil because of the water that's between the coil and the steam, and they've reduced the total amount of energy that the coil can carry by not letting the water out faster. When the mechanical traps are open, they drain water but release enough steam to cause a pressure gauge to drop. It you have 100 traps in your system, that's about 600 little pressure drops per minute. This adds up to 36,000 little pressure drops per hour, if all traps are working properly, and all of those pressure drops have to be made back up at the boiler. We estimate this costs 8% of total steam production. And this is with properly functioning mechanical steam traps. In a minute I'll show you how you can demonstrate this pressure drop at your own plant with a pressure gauge. You won't ever have these pressure drops with an orifice. Coil w/ Permanent Orifice: Orifices bleed off hot condensate; there is no pooling of water and no insulating effect. The orifice is constantly open to the condensate. The flow of condensate through the orifice is turbulent, not laminar, and there should be no measurable loss of steam through your entire cycle. You'll have consistent pressure and uniform heat transfer throughout the coil. Pressure Drop Experiment Figure 2 shows an experiment you can do at your own plant. Place a pressure gauge before a mechanical trap and you can measure a pressure drop each time the trap opens. This is an example of what we typically find when we measure temperatures with a heat gun at a plant: In the example on the left the pressure is at 100 psi when the trap is closed, and the temperature in the pipe after the trap is 203 degrees. When the trap opens, the pressure drops to 90 psi before the trap, and the temperature measures 240 degrees F through the pipe. In a plant converted to orifices there will be no pressure drop. The pressure remains at 100 psi before the trap, and the temperature measures 203 degrees F through the pipe and remains at 203 degrees. Now lets look at how these coils impact performance at a kiln. Animation from Coil to Kiln With mechanical traps, each coil and trap behaves differently from other coils and traps within a kiln (Figure 3), depending on the cyclical operation of the steam trap. Where the coils are hot, the wood will dry faster while the cold coils will result in wet wood. In 1992, an orifice company outperformed a prominent mechanical steam trap company in their own labs with brand new Armstrong steam traps. A mechanical trap running a 24- hour schedule has a life expectancy of 4 years. If you have a 100-trap system you need to buy or rebuild 25 traps a year, every year, just to maintain the 8% inefficiency level. If you don't, you'll have a greater level of inefficiency. With 300 total plant conversions and 800 plant projects during Enercon's 14 years, there has never been an increase in fuel consumption. The highest fuel savings have been 40-50%. Western Dry Kiln Association 59 May 2004

Pressure Drop Exper ent With orifices, each coil consistently has the same heat transfer rate. This results in more consistent drying from top to bottom and from end to end, providing a better quality product and a reduction in drying time per load. Now we can return to the plant level. Plant Comparison Plant Using Mechanical Traps: The further away a kiln is from the boiler, the more the kiln is impacted by the mechanical traps. Where coils are ganged together (two or three coils are going to one trap) rather than coils being trapped separately, short-circuiting makes this condition worse. Plant Using Permanent Orifices: Orifices allow consistent heat transfer rates throughout the plant. Plants are telling us that their energy efficiency is increasing by 10-20%. Plants are reporting more constant steam delivery to the kilns. Some plants have been able to add additional kiln capacity. Hampton has plants that have been able to run one or more additional kilns. Merritt Brothers in Idaho increased their kiln capacity from 3-1/2 kilns to 4 kilns. Western Dry Kiln Association 60 May 2004

14 i cont wood diyir 1 ter_azat of mriarions In!teat merrsr'er Typiami Center Carlo' IV Pe rmanent Orercos Wood dikes more ronzertently tl.lp to J"rattoefr end end to end Figure 3. Kiln with modulating control valve. Boiler Mechanical Traps create inconsistent heat transfer rates throughout plant Kilns furthest away from boiler are colder with mechanical trap systems Typical Kiln Plant w/ Permanent Orifice Boiler Orifices allow consistent heat transfer rates throughout plant Kilns have consistent heat transfer rates throughout plant with orifices Figure 4. Typical kiln plant with mechanical traps. Western Dry Kiln Association 61 May 2004

Summary of Topic One W hat makes an orifice installation successful? Proper sizing, quality hardware, and a warranty. Topic Screen Now I am going to talk about how orifices work with varying loads. People will say something like my boiler runs at 60,000 lbs per hour, but sometimes it only runs at 40,000 lbs per hour. How will orifices work with all of my loads? *TOM {fit WA:m4 NA '0** 0 10011 AMMON'.-RWEAW. 4.344War usassaskair Figure 5. Steam losses under varying loads. Steam Losses Under Varying Loads Chart This graph shows steam loss from an orifice at a constant flow 100 psi, 375 lbs of condensate per hour. With linear flow, you'd need 100% condensate capacity of the orifice to prevent steam from leaking. This isn't the case with turbulent flow. At 25% load, less than 2 lbs of steam per hour are lost. We estimate a new mechanical steam trap will lose about 35 lbs of steam per hour from the 8% inefficiency I've been talking about. There is no measurable loss of steam at 68% and above condensate capacity. Sometimes people think orifices improve efficiency only where the mechanical steam traps are bad. Actually, the worst case with an orifice is better than the best case with mechanical steam traps. The guidelines for loads that qualify for an orifice are 25% to 100% of load. This is also known as a 4:1 turndown. W hen you have a modulating control valve, when more heat is needed, the control valve opens to increase steam flow, which translates to greater pressure differential across the nozzle, and higher nozzle capacity. As demand drops, the control valve closes and both pressure and condensate load are reduced. This keeps the load at the orifice itself within the 4:1 turndown ratio. Western Dry Kiln Association 62 May 2004

With a modulating control valve, the load physically can't vary outside of the guidelines, whether you're at 5 lbs or 150 lbs. of pressure. Virtually all properly designed applications will not vary outside the guidelines for an orifice. In 14 years and 800 plants, over 99% of mechanical steam traps have been convertible to orifices. Most of the remaining portion of 1% is not converted because of improper design or it is not cost-effective. I have an example of how we size a permanent orifice to work with three varying loads in a kiln plant. The plant has a control valve that modulates from 100 psi to 0 psi. The following conditions prevail in all three cases: 1) Our product in each case starts at a temperature of 100 degrees Fahrenheit. 2) We are working with 10 square feet of stainless steel coil surface in water. 3) The BTU transfer rate is 150 The formula used in each case is as follows: The transfer rate in BTUs per square ft of surface area per degree F differential multiplied by the surface area of the stainless steel coil multiplied by the difference between the temperature of the steam at the given pressure and the temperature of the product. This yields a number of pounds of water to pass through the orifice at the given pressure. This number is used in a proprietary look-up table to yield the desired orifice for the given pressure along with a percentage of water occupancy of the orifice. This calculation is repeated for all three conditions and used to determine the optimal orifice size. This size then provides an associated percentage of occupancy of the orifice under each of the three pressures. From this we can determine the amount of steam loss for that orifice size under the three varying loads. The first case (Figure 6) we want to size the orifice for is for 100 psi. The btu heat transfer rate of the metal used here at start up is 150 btus per sq ft of surface area per degree Fahrenheit differential. Under these conditions you need to pass 405.7 lbs of condensate at 100 psi. The second case we want to size the orifice for is for 50 psi. The btu heat transfer rate of the metal used here at start up is 150 btus per sq ft of surface area per degree Fahrenheit differential. Under these conditions you need to pass 303.0 lbs of condensate at 50 psi. The third case we want to size the orifice for is for 10 psi. The btu heat transfer rate of the metal used here at start up is 150 btus per sq ft of surface area per degree Fahrenheit differential. Under these conditions you need to pass 220.6 lbs of condensate at 10 psi. Summary of Information on the Three Cases This screen summarizes the information we just covered. As pressure is lowered, with the modulating control valve, the btu's per hour are reduced and the amount of condensate in lbs per hour is reduced. Western Dry Kiln Association 63 May 2004

Common Condition stainless steel cod surface: transfer rate: product temperature at start 10 square feet 150 8TUsisq ft/degree F difference 100 degrees Fahrenheit Formula for calculating aterflow per hour: steam pressure in pig Case One Case Two Case Three associated temperature of steam 284 240 minus prockict temperature at start -100-100 BTUs per so ft of surface area per degree F. difference 23184 multiplied by the surface area of the st.ainless steel cod e difference between the temperature of Me steam 150 BTUs per hour 357000 276000 210000 divided by BTUs transferred per pound 860 911 952 water flow per hour 405.7 303.0 220.6 orifice we percent r rapancy given pressure orifice size 10 15 10 percent occupancyat given pressor 72% 76% 96% associated steam loss 0 0 0 Figure 6. Example of varying load for a kiln with a modulating control valve. Sizing: Now we are going to use this information to properly size the orifice to best meet these three cases. 100 psig: W hen we look up a proprietary table associated for 100 psi we size the orifice for optimal capacity. We select an orifice #9 with 100% condensate capacity or a 4:4 turndown. 50 psig: When we look up in the table associated for 50 psi we size the orifice for optimal capacity. We again select an orifice #9 with over 100% condensate capacity or a 4:4 turndown. Again we can see from the Orifice Steam Loss graph below that you have no measurable steam loss from the orifice. 10 psig: When we look this up in the table for 10 psi we size the orifice for optimal capacity. This time we select an orifice #10 with 96% condensate capacity or nearly a 4:4 turndown. Once again we can see from the Orifice Steam Loss graph below that you have no measurable steam loss from the orifice. Western Dry Kiln Association 64 May 2004

Now using the information in the proprietary charts for a number 10 orifice where the water passing fits the three cases we see what percentage of occupancy occurs. Under 50 psig with 303 lbs of water passing per hour the #10 shows an occupancy of 76%. Under 100 psig with 406 lbs of water passing per hour the #10 shows an occupancy of 72% or again 0 lbs of steam loss. Steam Losses Under Varying Loads Chart Showing Three Percentages We go with the size #10. We can see from the Orifice Steam Loss graph that we have no measurable steam loss from the orifice under all three cases. Summary of Comparisons between Permanent Orifices and Mechanical Traps A steam trap's job is to let water out and hold back steam. An orifice is more efficient than a mechanical trap at doing both. Summary of Operational Benefits More Consistent Drying for improved quality and grade recovery Improves fuel efficiency 8% to 20% for more usable steam supply or cost savings Faster Drying Times approximately 8% to 12% of time Eliminates maintenance and repair of traps permanently Benefits to Our Environment Reduction of air pollutants and greenhouse gas emissions per load permanently and profitably Less makeup water used reduces chemicals and water pollution Western Dry Kiln Association 65 May 2004