Installation & Operation Manual

Similar documents
Installation & Operation Manual

Installation & Operation Manual

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

User Manual 561_U. WiFi Thermostat 561. Introduction 10/16

- User Brochure tekmarnet 4 Setpoint Control 161

- User Brochure Programmable Thermostat 510

Installation & Operation Manual

Radiant Thermostat 519

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653

Installation & Operation Manual

Installation Manual. THM-0200 Programmable Thermostat Version 1.07 THM HBX Control Systems Inc.

- Data Brochure Mixing Reset Module 421

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Installation Instructions

For household use only. Page. Model. Contents R-B500PT6

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

Installation Instructions

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat

INSTRUCTION MANUAL P Heating and 1 Cooling

2010 ADA Standards for Accessible Design

552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

VX SERIES Wireless Thermostat with Occupancy Sensor

Lyric T6 & T6R Smart Thermostat

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

PRO Installation. Thermostat Wi-Fi

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

FiRe mobile-2 Operation Manual

T5+ Smart Thermostat Programmable Thermostat RCHT8610WF, RCHT8612WF

Programmable Thermostat

HEAT HEAT HEAT COOL COOL

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

OPERATION & INSTALLATION MANUAL

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Thermostat TP42H01 User Manual

SMART 5000 Wi-Fi Touchscreen Programmable Thermostat Owners Manual

On initial power up the thermostat will guide you through set up procedure for the following:

SMART 1000 Touchscreen Thermostat Installation Manual

CT2 Retro Box Installation Instruction Manual

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

INSTALLATION & OPERATION MANUAL

Installation, Configuration and User Manual

TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling

4iE Smart WiFi Thermostat Operating Guide

- Data Brochure D 261. Boiler Control 261

ENTOUCH ONE USER GUIDE

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

Professional Model Owner's Manual

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

- Data Brochure Steam Control 279

Installation & Operation Manual

Non-Programmable Digital Thermostat

RC-2000 Thermostat Installation Instructions

GLAS. Installation Instructions

Owner's Manual THZ-100. Thermostat

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

FLCH4R Garage and Utility Electric Heater

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

SC Installation, Operation & Application Guide

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Installation and Operations Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Smart Si Thermostat. Installation Manual

ICM 275. Replacement Description

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Bosch Connected Control

Duct Mount. Installation Instructions

Ultrasonic Reflective Sensor

Installation & Operation Manual

Daikin ENVi Thermostat installation overview

Installation & Operation Manual

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

TH8320U and TH8321U Touch Screen Programmable Thermostats

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Installation & Operation Manual

Installation & Operation Manual

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Manual & Technical Documentation V1.1

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this

BACKUP BATTERY INSTALLATION INSTRUCTIONS

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

- Data Brochure Universal Reset Module 423

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

SC Installation, Operation & Application Guide

Owner's Manual [ S/N LABEL HERE ] Document # BW-WT4-1DOC

Transcription:

Installation & Operation Manual WiFi Thermostat 562 562_D 08/17 Zoning eplaces: 12/16 Introduction The WiFi Thermostat 562 provides precise temperature control of a heating and cooling system. When connected to the Internet, the mobile app and website allow you to control the thermostat remotely. The thermostat and mobile app include an away feature that overrides the schedule to lower the temperature and increase energy savings. The thermostat is designed to support radiant floor heating and optional floor sensors can be installed to enhance comfort and protect floor coverings. Features Mobile app for ios and Android Supports optional floor sensor Automatic software updates Outdoor temperature Local weather Email error and warning notifications Time clock updated from Internet 7 day programmable schedule Away energy savings mode Early start Energy monitoring English/Français/Español languages 3.5" color touchscreen Selectable background colors

Table of ontents Installation...4 Preparation...4 emoving The Thermostat Base...4 Mounting The Thermostat...5 elay Power Jumpers...5 Application 562-1...6 Application 562-2...7 Application 562-3...8 Application 562-4...9 Sequence of Operation...10 Heating Operation...10 ooling Operation...10 User Interface... 11 Home Screen... 11 User Settings...12 Away...12 Schedule...12 Display...13 Time...14 Fan...14 WiFi...15 Installer Settings...16 Setup...16 Setup - Toolbox...16 Setup - Temp...17 Setup - Sensors...18 Setup - Alerts...18 Setup - elays...19 tekmar onnect Web and Mobile App...20 Troubleshooting...22 Error Messages...22 Technical Data...23 Limited Warranty and Product eturn Procedure...24 2 of 24

Important Safety Information It is your responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards. tekmar is not responsible for damages resulting from improper installation and/or maintenance. This is a safety-alert symbol. The safety alert symbol is shown alone or used with a signal word (DANGE, WANING, or AUTION), a pictorial and/or a safety message to identify hazards. When you see this symbol alone or with a signal word on your equipment or in this Manual, be alert to the potential for death or serious personal injury. This pictorial alerts you to electricity, electrocution, and shock hazards. This symbol identifies hazards which, if not avoided, could result in death or serious injury. This symbol identifies hazards which, if not avoided, could result in minor or moderate injury. This symbol identifies practices, actions, or failure to act which could result in property damage or damage to the equipment. ead Manual and all product labels BEFOE using the equipment. Do not use unless you know the safe and proper operation of this equipment. Keep this Manual available for easy access by all users. eplacement Manuals are available at tekmarontrols.com It is the installer's responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards. Improper installation and operation of this thermostat could result in damage to the equipment and possibly even personal injury or death. This thermostat is not intended for use as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit. Do not attempt to service the thermostat. There are no user serviceable parts inside the thermostat. Attempting to do so voids warranty. 3 of 24

Installation Preparation Tools equired ------------------------------------------------------ tekmar or jeweler screwdriver Phillips head screwdriver Wire stripper Drill (for wall anchor) 3/16" drill bit (for wall anchor) Materials equired -------------------------------------------------- 18 AWG LVT Solid Wire (Low Voltage onnections) Installation Location ------------------------------------------------- onsider the following: Interior Wall. Keep dry. Avoid potential leakage onto the control. elative Humidity less than 90%. Non-condensing environment. No exposure to extreme temperatures beyond 32-122 F (0-50 ). No draft, direct sun, or other cause for inaccurate temperature readings. Away from equipment, appliances, or other sources of electrical interference. Easy access for wiring, viewing, and adjusting the display screen. Approximately 5 feet (1.5 m) off the finished floor. The maximum length of wire is 500 feet (150 m). Strip wire to 3/8" (10 mm) for all terminal connections. Use standard 8 conductor, 18 AWG wire. emoving The Thermostat Base While holding the base section in one hand, pull the lower half of the display front towards you to pivot it away from the base. 4 of 24

Mounting The Thermostat To prevent the risk of personal injury and/or death, make sure power is not applied to the thermostat until it is fully installed and ready for final testing. All work must be done with power to the circuit being worked on turned off. Please be aware local codes may require this thermostat to be installed or connected by an electrician. Stud Thermostat Base Thermostat Front 3 1 /4" (83 mm) Switch Box Thermostat Front Wall Thermostat Base Stud elay Power Jumpers The thermostat includes three relay power jumper connectors located below the wiring hole. AWAY SEN OM S1 S2 ON OFF J1 J2 J3 ELAY POWE JUMPE h1 W1 h2 W2 c Y1 G J1 J2 J3 WiFi Thermostat 562 J1 J2 J3 ON ELAY POWE OFF JUMPE Set Jumper J1 to On to connect power to the h1 terminal. Set Jumper J2 to On to connect power to the h2 wiring terminal. Set Jumper J3 to On connects power to the c wiring terminal. Set the jumper to off to disconnect the power from h1, h2, or c respectively. 5 of 24

Application 562-1 The WiFi Thermostat 562 operates a one or two-stage furnace for heating and an air conditioner for cooling. Mechanical ---------------------------------------------------------- Legend 1 = Air onditioner F1 = Furnace T1 = WiFi Thermostat 562 T1 1 F1 Electrical ----------------------------------------------------------- Thermostat jumpers: J1 = On J2 = On J3 = On J1 J2 J3 ON ELAY POWE OFF JUMPE WiFi Thermostat 562 AWAY SEN OM S1 S2 h1 W1 h2 W2 c Y1 G Furnace Terminals W1 W2 Y G 6 of 24

Application 562-2 The WiFi Thermostat 562 operates a first stage radiant floor and a second stage furnace for heating, and an air conditioner for cooling. Mechanical ---------------------------------------------------------- Legend B1 = Boiler BP = Boiler Pump 1 = Air onditioner F1 = Furnace PS = System Pump T1 = WiFi Thermostat 562 V1 = Zone Valve S1 = Optional Floor Sensor 079 S2 = Optional Indoor Sensor 084 ZV1 = Zone Valve ontrol 304V, 306V T1 S2 ZV1 B1 V1 1 F1 PS S1 BP Electrical ----------------------------------------------------------- Thermostat jumpers: J1 = On J2 = J3 = and install field jumper wire from h2 to c J1 J2 J3 ON ELAY POWE OFF JUMPE S1 S2 AWAY SEN OM S1 S2 AWAY W WiFi Thermostat 562 h1 W1 h2 W2 c Y1 G ZV1 Furnace Terminals W Y G 7 of 24

Application 562-3 The WiFi Thermostat 562 operates a first stage radiant floor and a second stage fan coil for heating, and an air conditioner for cooling. Mechanical ---------------------------------------------------------- Legend B1 = Boiler BP = Boiler Pump 1 = Air onditioner F1 = Fan oil PS = System Pump S1 = Optional Floor Sensor 079 S2 = Optional Indoor Sensor 084 T1 = WiFi Thermostat 562 V1 = adiant Zone Valve V2 = Fan oil Zone Valve ZV1 = Zone Valve ontrol 304V, 306V T1 S2 F1 ZV1 1 B1 BP V2 PS V1 S1 Electrical ----------------------------------------------------------- Thermostat jumpers: J1 = On J2 = J3 = and install field jumper wire from h2 to c J1 J2 J3 ON ELAY POWE OFF JUMPE S1 S2 AWAY SEN OM S1 S2 AWAY W WiFi Thermostat 562 h1 W1 h2 W2 c Y1 G ZV1 Air Handling Unit Terminals X X Vlv W Y G B1 V2 8 of 24

Application 562-4 The WiFi Thermostat 562 operates a first stage baseboard/radiator and a second stage fan coil for heating, and an air conditioner for cooling. Mechanical ---------------------------------------------------------- Legend B1 = Boiler BP = Boiler Pump 1 = Air onditioner F1 = Fan oil PS = System Pump S1 = Optional Floor Sensor 079 S2 = Optional Indoor Sensor 084 T1 = WiFi Thermostat 562 V1 = adiant Zone Valve V2 = Fan oil Zone Valve ZV1 = Zone Valve ontrol 304V, 306V T1 S1 F1 ZV1 1 B1 BP V2 PS V1 Electrical ----------------------------------------------------------- Thermostat jumpers: J1 = On J2 = J3 = and install field jumper wire from h2 to c J1 J2 J3 ON ELAY POWE OFF JUMPE S1 S2 AWAY SEN OM S1 S2 AWAY W WiFi Thermostat 562 h1 W1 h2 W2 c Y1 G ZV1 Air Handling Unit Terminals X X Vlv W Y G B1 V2 9 of 24

Sequence of Operation Heating Operation The Heat On symbol is shown on the display when the thermostat is heating. Heating for freeze protection is provided whenever the air or floor temperature falls below 40 F (4.5 ), regardless of operating mode. egular Heating ----------------------------------------------------- W1 relay is on when the air temperature falls 1.5 F (1 ) below the Heat To setting. When the temperature reaches the Heat To setting, the relay turns off. The W2 relay turns on based on settings selected in the Setup menu. W2 turns off when the air temperature is 0.5 F (0.25 ) below the Heat To setting. adiant Floor Heating ------------------------------------------------ When adiant Floor Heating is selected in the setup menu, the W1 relay operates using Pulse Width Modulation. This improves comfort for radiant systems with high mass floors. 100% on time at Heat To setting -1.5 F 50% on time at Heat To setting 0% on time at Heat To setting + 1.5 F Floor Sensor for adiant Floor Heating ------------------------------- If a floor sensor is connected, floor minimum and maximum settings are available. For a combination of air and floor temperature control, leave the internal air sensor on in the setup menu. A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure. This operation is recommended for areas heated by afternoon sun through large windows. When the sun sets, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room. A floor maximum is recommended for rooms with hardwood floors. Setting floor minimum and maximum temperatures is a way of enhancing the comfort of the living space while protecting floor coverings. Warm Weather Shut Down (WWSD) ----------------------------------- The heating system can automatically shut off based upon the outdoor temperature and the WWSD setting. This provides a convenient way to shut off radiant floor heating. ooling Operation The ool On symbol is shown on the display when the thermostat is cooling. ooling relay Y1 turns on at ool To setting + 1.5 F (1 ) ooling relay Y1 turns off at ool To setting old Weather Shut Down (WSD) ------------------------------------ The cooling system can automatically shut off based upon the outdoor temperature and WSD setting. This prevents unwanted cooling during the winter. 10 of 24

User Interface Home Screen After 60 seconds of inactivity, the thermostat home screen displays only the time and the temperature. Go to schedule urrent time Swipe to view: Weather Outdoor temperature Floor temperature Heat To setting ool To setting hange operating mode urrent temperature Equipment operation (Heat or ool On) Go to settings 3 4 5 6 3 7 3 8 9 : ; 4 Touch or to adjust temperatures Select either Heat To or ool To < = >? @ A B? @ > D B = E F? < G >? E A D G H < G I J J K L Save ancel - + # 1 2 1 'Save to schedule' applies the new temperature to the current schedule event.! " # $ % & ' ' ( ) * +, - # *. / - 0 - Hold overrides the programmed schedule until the time shown 11 of 24

User Settings Away Use the Away setting to save energy when the building is unoccupied. The away setting is shared to: All WiFi Thermostats in a mobile app "Location" WiFi Thermostat 562 shares the away signal to Thermostats 518 & 519 connected to tekmar Switching elays 304P & 306P or Zone Valve ontrols 304V & 306P M N O P Q S T U Operates normally Operates using the Away temperature selected in the Setup menu Save V W X Y Z [ V \ ] ^ away signal Schedule urrent group of program days. Early Start anticipates the time required to heat or cool a room and starts early. f ] g e^ ` W ] gw h i z { P } ~ P o Y i d [ j [ c b d g j ] k [ l m n n V o p n q p r q s [ ] t [ u m n n V o l r q p u q v [ W d g i l m n n w o p n q p r q ` e [ [ x y n m n n w o l r q p u q _ [ \ ` a b [ c d e [ ` a b [ c d e [ h i reates a new schedule. Go to the next group of program days. Heating temperature ooling temperature Set to On to follow the schedule. Set to to use the same temperature all of the time. 12 of 24

 Schedule «± «² ³ µ ¹ º» ¼ ½ Set schedule start time ª ¾ À À Á Select skip if you don't want a temperature change. Set heating temperature Ê Ë Ì Æ Æ Ä Ç À É Set cooling temperature Ã Ä Ä Å Æ Ä Ç È É Info Display Setting ange Default TEMPEATUE UNITS Select F or. ENEGY USE View the number of hours the heating or cooling has operated either daily or monthly. ƒ ˆ Š F or F š š œ š š š š Œ Ž š š ž Ž š š ž š š Ÿ š š 0 to 24 (daily) 0 to 744 (monthly) 0 hours Œ Ž BIGHTNESS ATIVE Select the brightness when touching the screen. BIGHTNESS INATIVE Select the brightness when not in use. BAKGOUND Select the background color. LANGUAGE Select the language. SEEN LEAN Locks screen for 10 seconds to allow cleaning. 13 of 24 30 to 100% 100%, 30 to 100% 50% White, Blue, Black, Latte, Espresso English, Español, Français N/A Blue English N/A

Time Ö Ø Ù Ú Û Ü Ö Ù â ã ä å æ å ß Ý ç Ý Þ ß à á When connected to the Internet, the time can be set automatically. The time and date can be manually set by highlighting a field and then using the or buttons. Ð è é ê Ð ë ì hoose from the time options listed below. Setting ange Default TIME FOMAT Select the time format. TIME SOUE If Internet is available, the time source can be either automatically or manually set. TIME ZONE Select the local time zone. DAYLIGHT SAVING TIME Select the brightness when not in use. 12 or 24 hour 12 hour Automatic, Manual Hawaii, Alaska, Pacific, Mountain, entral, Eastern, Atlantic, Newfoundland, On Auto Eastern On Incorrectly setting the time and date manually may prevent the thermostat from communicating to the mobile app. Automatic time source is recommended when using an Internet connection. Fan Í Î Ï Í Î Ï Ð Ñ Ò Ó Ô Õ The fan is normally off when set to auto but turns on when needed for the heating or cooling equipment. ñ ï ò î Ð Ñ í î ï ð î Ò Ó Ô Õ ó î Ô Ó ô Ñ Ð Ñ When a programmable schedule is used, there is a fan setting for each time period. ì õ î î ö Ò Ó Ô Õ 14 of 24

ƒ v WiFi Before using the WiFi features of this product, you must accept the Terms of Use, as amended from time to time and available at tekmaronnect.com/terms. If you do not accept these terms, this product can still be used without WiFi features. This product requires WiFi WPA security. WEP is not supported. The thermostat includes a step by step tutorial to setup the WiFi connection. ø ù ú û ü ý þ b c d c x y b z { m m c }! " # $ % & ' ( ) * ) +,, -. / /, 0 1 2 3 4 5 6 7 7 0 8, 9 8 6 2 /, 0 4 2 : * ; < = >? @ @ * ) A B D E F G E H E I J K K L M I I N L O L I L P Q O S T U V W X Y Z [ \ S \ ] ^ V S U ` a [ V a Z $ A h i i h j ) & $ ) ƒ q o q o ÿ e f g ~ h e e ~ g Step 1 Agree to Terms of Use Step 2 Turn on WiFi Step 3 Enter wireless network name. y ù l û ý ú û š ³ c ú ù ý þ ü k l m ú ø û n l ˆ ~ ÿ ž œ Ÿ «ª Œ o p q r s p t u v e h Š s j o s w g f ± ² Ž i p Œ ÿ w i p Œ ÿ w ~ h e e ~ g h e f g Step 4 Enter WiFi password. Step 5 Enter ZIP or postal code. This determines your location for weather information. 15 of 24 Step 6 Select if the time is set automatically from the Internet or manually.

Installer Settings Setup The Setup menu contains five sub-menus that determine how the thermostat operates. The Access Level setting in the Toolbox menu determines how many settings are available to the user. µ ¹ º» ¼ ½ ½ ¾ ½ À ¼ Á Â Ã Ä Á Å Ä ½ Æ Ä Ç ¾ Á Æ ¼ Ä Press back to return to the main Settings menu. Æ Á ¾ Ç È Ä Setup - Toolbox Setting ange Default EO Displays any error messages. AESS LEVEL Select between user and installer access levels. User access level restricts access in the Setup Menu. STATUS The current status of warm weather shut down, cold weather shut down and each of the relays. SOFTWAE VESION Display the software version. LOAD DEFAULTS All settings are returned to factory defaults. ALIBATE TOUHSEEN ecalibrate the screen after loading factory defaults. N/A User, Installer WWSD, WSD, W1, W2, Y1, G1 J1255A Yes, No N/A N/A Installer N/A N/A No N/A 16 of 24

Setup - Temp Setting ange Default Screen Page 1 FLOO MIN - WAKE Select the floor temperature while in the wake schedule. Applies when there is both a floor and an air sensor. FLOO MIN - LEAVE Select the floor temperature while in the leave schedule. Applies when there is both a floor and an air sensor. FLOO MIN - ETUN Select the floor temperature while in the return schedule. Applies when there is both a floor and an air sensor. FLOO MIN - SLEEP Select the floor temperature while in the sleep schedule. Applies when there is both a floor and an air sensor. FLOO MIN - AWAY Select the floor temperature while in away. Applies when there is both a floor and an air sensor. FLOO MAX Select the maximum floor temperature. This protects the floor covering from over heating. Applies when there is a floor sensor. Screen Page 2 HEAT TO AWAY Select the heating temperature when away. HEAT TO MIN LIMIT Select the minimum heating temperature limit. HEAT TO MAX LIMIT Select the maximum heating temperature limit. OOL TO AWAY Select the cooling temperature when away. OOL TO MIN LIMIT Select the minimum cooling temperature limit. OOL TO MAX LIMIT Select the maximum cooling temperature limit. Screen Page 3 WAM WEATHE SHUT DOWN Select the outdoor temperature at which the heating is shut off. OLD WEATHE SHUT DOWN Select the outdoor temperature at which the cooling is shut off., 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0, 40 to 95 F, 4.5 to 35.0 62 F (16.5 ) 17 of 24

Setup - Sensors Setting ange Default SENSO 1 Select the type of sensor connected to S1 and om wiring terminals. SENSO 2 Select the type of sensor connected to S2 and om wiring terminals. INTENAL OOM SENSO Select if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room sensor. OOM OFFSET Manual offset correction of the room temperature measurement., oom, Floor, oom, Floor, Outdoor, On, -5 to +5 F -3.0 to 3.0 On Setup - Alerts Setting ange Default OOM HOT WANING Sends an email notification if the room exceeds this temperature. OOM OLD WANING Sends an email notification if the room falls below this temperature. AI FILTE HANGE Sends an email notification to change the air filter when the fan exceeds this run time., 40 to 100 F, 4.5 to 38.0, 40 to 100 F, 4.5 to 38.0, 200 to 2000 hours 18 of 24

Setup - elays Setting ange Default EQUIPMENT Select the number of stages of the heating and cooling equipment. ADIANT FLOO HEATING Select if the first stage W1 heats a radiant floor. W2 DIFFEENTIAL Select when the second stage W2 heating turns on. Turn on point is the heat to minus the differential. W2 DELAY Select the time delay when the second stage W2 heating turns on. The time starts counting after the W1 relay is turned on. Y MIN UN TIME Select the minimum time the cooling compressor must run before shutting off. This helps prevent compressor failure. Y MIN OFF TIME Select the minimum time the cooling compressor must be off before turning back on. This helps prevent compressor failure. Screen Page 2 FAN ELAY Select which relays require fan operation. ombinations with W1 are not available when adiant Floor Heating is set to yes. HEAT-OOL TIME INTELOK When operating in Mode Auto, select the amount of time to wait between switching from heating to cooling and vice versa. 1 Heat/1 ool, 2 Heat/1 ool No, Yes 2 to 10 F 1.0 to 5.5 0 to 180 minutes 0:30 to 10:00 minutes 0:30 to 10:00 minutes G only, With Y With Y and W1, With Y and W2, With Y, W1 and W2 0 to 180 minutes 1Heat/1 ool No 2 F 1.0 1 minute 2:00 minutes 5:00 minutes G only 10 minutes 19 of 24

tekmar onnect Web and Mobile App To view and adjust the WiFi Thermostat using a mobile phone or tablet, download the tekmar onnect mobile app from the Apple itunes Store or from the Google Play Store. Alternatively, go to tekmaronnect.com for web browser access. Add Thermostat to App ---------------------------------------------- Home HOME É Ê Ë Ì Í Î É Ï Î Ì Ð Ñ Email Password You don't have any devices associated with this location. ADD A DEVIE Î Ò Ó Ô Õ Ô Ö Ø Ù Ú Ô Ö Û Ù Ø Ô Õ Ú Ü Ò Ý Ø Û Ù Ø Þ Ò Ö Û ß Û à Ù Õ Û Ù Ø Û Ù á Ò â Ù â Ô Ö ã ä ß Ü Ù â å Ù ä Ò æ ß Û Û Ù ç Þ ß Ø è Ò Õ Õ Ù á Û é á Ò Þ SIGN IN ê ë ì í î ï ð ñ Forgot Password Don't have an account? SIGN UP AND GET STATED Terms and conditions My Devices Account Step 1 reate a new account. Then login using your username and password. Step 2 Add a Device Step 3 On the thermostat, go to WiFi menu and press egister Device. Add a Device Edit Your Account Home Activation Number 12345678 Device Name WiFi Thermostat 562 Username name@domain.com First & Last Name Email Address HOME WiFi Thermostat 562 78 F Auto Location Home Phone (###)###-#### Units F ADD DEVIE hange Password SAVE Logout My Devices Account My Devices Account My Devices Account Step 4 Enter the 8 digit number from the thermostat into the mobile app. Then enter the thermostat's room name. The app supports multiple site locations. Enter the location for the thermostat. Step 5 Edit your account and save. 20 of 24 The thermostat is now listed on the My Devices page.

Using the App ------------------------------------------------------- hoose a location. Home Set to AWAY to save energy when you are away for a day or more. HOME WiFi Thermostat 562 Add a device Edit location info WiFi Thermostat 561 75 F Heat View and change thermostat WiFi Thermostat 562 78 F Heat My Devices Account Edit account info hange from Heat, ool, Auto or mode Auto WiFi Thermostat 562 View and edit schedule hange heating and cooling setting View energy usage Edit device info HEAT TO 70 OOL TO 76 Save temperature change to the schedule eturn to home view SAVE TO POGAM My Devices TEMP 40 72 100 ANEL HOLD Account Temperature change hold until schedule change 21 of 24

Troubleshooting Error Messages When an error occurs an email notification will be sent to the registered tekmar onnect mobile or web app account owner. Description MEMOY EO The thermostat memory settings are corrupted. To clear, load the factory defaults in the Toolbox menu. The thermostat will not operate any heating or cooling equipment while this error message is present. INTENAL OOM SENSO FAULT Due to an open or short circuit, the thermostat is unable to read the internal room temperature sensor. If sensor 1 or 2 is set to room the thermostat continues to operate, otherwise operation stops. The error cannot be field repaired. ontact your tekmar sales representative for warranty or repair procedures. SENSO 1 FAULT Due to an open or short circuit, the thermostat is unable to read the sensor wired to S1 and om. The thermostat stops normal operation if sensor 1 is the only active room or floor sensor or if a floor maximum temperature has been set. heck the auxiliary sensor wire for short circuits according to the sensor installation manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears. SENSO 2 FAULT Due to an open or short circuit, the thermostat is unable to read the sensor wired to S2 and om. The thermostat stops normal operation if sensor 2 is the only active room or floor sensor or if a floor maximum temperature has been set. heck the auxiliary sensor wire for short circuits according to the sensor installation manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears. OOM HOT WANING The room temperature is above the oom Hot Warning setting in the Alerts menu. The warning will automatically clear once the room temperature falls below the setting. OOM OLD WANING The room temperature is below the oom old Warning setting in the Alerts menu. The warning will automatically clear once the room temperature rises above the setting. HANGE AI FILTE The fan run time has exceeded the hange Air Filter setting in the Alerts menu. To ensure clean air it is recommended to replace the air filter on the heating and cooling equipment. While viewing the warning, press the lear button to clear the warning and reset the fan run time counter. 22 of 24

Technical Data WiFi Thermostat 562 Two Stage Heat, One Stage ool, Fan Literature ontrol Packaged weight 0.7 lb. (300 g) Dimensions 562_, 562_D, 562_J, 562_U Microprocessor control. This is not a safety (limit) control. 4-5/8" H x 3" W x 15/16" D (118 x 76 x 24 mm) Enclosure White PV plastic, NEMA Type 1 Approvals Meets lass B: IES & F Part 15 Ambient conditions Indoor use only, 32 to 122 F (0 to 50 ), H 90% noncondensing Power supply 15 to 30 V (ac/dc), 2 VA standby, lass 2 elays 30 V (ac/dc), 2 A, lass 2 circuits Sensor NT thermistor, 10 kω @ 77 F (25 ±0.2 ) ß=3892 Included None Optional tekmar type # 070, 072, 073, 076, 077, 079, 084 ommunications Mobile app WiFi 802.11n, 2.4 GHz, WPA2 encryption Apple ios 9 or higher, Android 5 or higher 23 of 24

Limited Warranty and Product eturn Procedure Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product ( Product ), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer s passthrough warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar s instructions, ordinary wear and tear excepted. The passthrough warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract. The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser s agreement and warranty with its customers. Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers. The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar s instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar s instructions. THIS WAANTY IS IN LIEU OF ALL OTHE WAANTIES, EXPESS O IMPLIED, WHIH THE GOVENING LAW ALLOWS PATIES TO ONTATUALLY EXLUDE, INLUDING, WITHOUT LIMITATION, IMPLIED WA- ANTIES OF MEHANTABILITY AND FITNESS FO A PATIULA PUPOSE, DUABILITY O DESIP- TION OF THE PODUT, ITS NON-INFINGEMENT OF ANY ELEVANT PATENTS O TADEMAKS, AND ITS OMPLIANE WITH O NON-VIOLATION OF ANY APPLIABLE ENVIONMENTAL, HEALTH O SAFETY LEGISLATION; THE TEM OF ANY OTHE WAANTY NOT HEEBY ONTATUALLY EXLUDED IS LIM- ITED SUH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOU (24) MONTHS FOM THE PODUTION DATE, TO THE EXTENT THAT SUH LIMITATION IS ALLOWED BY THE GOVENING LAW. Product Warranty eturn Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar epresentative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar epresentative, including an inquiry from Purchaser (if not a tekmar epresentative) or Purchaser s customers, regarding a potential warranty claim, tekmar s sole obligation shall be to provide the address and other contact information regarding the appropriate epresentative. WANING: This product contains chemicals known to the State of alifornia to cause cancer and birth defects or other reproductive harm. For more information: Watts.com/prop65 All specifi cations are subject to change without notice Tel: (250) 545-7749 Fax: (250) 984-0815 tekmarontrols.com 562_D - 08/17 24 of 24 2017 tekmar