H&H Asia Group Limited

Similar documents
BL Series INSTRUCTIONS

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Thank you for purchasing Pegasus automatic unit.

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL

MCLX HX. Spiral Pump(Mechanical Seal Type) Mold Temperature Controller. Summary. Performance Curve. Lift

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTRUCTIONS FOR THD-U SERIES HOT AIR MATERIAL DRYERS

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Owner s Manual RD432-0 Chemical Controller

USER S MANUAL HSC-14/18/24/24A

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

PO Box 827 Hawley, MN (218) Fax (218)

ELECTRONIC GUN SAFE USER MANUAL. Models: SLSFE61GN - SLSFE63GN

Trouble Shooting Guide PWA, 3-phase (D10571)

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

OWNER S MANUAL ABSFBM-200T

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Desoldering Tool. (HAKKO FR-4102) Instruction Manual. Table of Contents

Trouble Shooting Guide RAA, 1-phase (D3627)

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

Trouble Shooting Guide PAA, 1-phase (D3731)

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

nanoheat PAD Quick User Guide This appliance is approved, applicable to most countries in Europe and Asia but not the U.S. and Canada.

Trouble Shooting Guide FAA, 3-phase (D3631)

DRAIN WATER TEMPERING INSTALL

Optima S2055/6. Wall Mount Space Heater with Cooling Fan. Installation and Operating Manual

P4200PM / P5000PM Remote Air Dryer User s Guide

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

MODEL MW200 MODEL MW600 AIR DRYER

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TC515 and TC600 Installation Manual. a Winters company

Operating Instructions

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Installation Instructions DTC-24 SNOw MELTING &

INSTALLATION & OPERATION MANUAL

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC

SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

Instruction Manual EN CP COMPRESSOR. Model CPD CPD 75

INSTALLATION AND USER MANUAL

SCAD-U Series Compressed Air Dryer

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

SMD Rework Station with Vacuum Pickup. Instruction Manual

Portable Air Conditioner

Instruction Manual. SMD Rework Station with Vacuum Pickup TABLE OF CONTENTS

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

Mold Temperature Controller GMC (L, H, A) U. Instruction Manual

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Oven Control System Operation - Ver 2.8

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Customer Service...1. Calibration...8. Inspection...9. Lighting Cleaning Features Control Box Digital Timers...

SSV-DC user manual. Phason

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DC200 Digital Dispenser Operating Manual

DIESEL PARTICULATE FILTER CLEANING MACHINE USER MANUEL

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

ELECTRIC FIRE PUMP CONTROLLER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Undercounter AquaTemp HUMIDITY OVENS and CONVECTION OVENS 2000 WATTS

M770 ph Controller Owner s Manual

Refrigerated Compressed Air Dryer

AC-12200E Portable Air Conditioner

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL

Emerson Blue Easy Set 1H/1C

INSTALLATION AND OPERATION MANUAL TURBO CONVECTION OVEN TCO85

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

IMPORTANT INSTRUCTIONS READ & SAVE

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

ADD FLUID 300 NDNL 300 CT 300 OC 700 NDNL 725 NDNL 950 NDNL

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Oceanic Sauna Heater Manual

3. OPERATING INSTRUCTIONS & INSTALLATION

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HG Million Btu/Hr Gas-Fired Heater

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

Press Machine Safety Guide

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Mix Boiler & Font Range ( #, #, #, , )

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

NSC HEAT SEAL MANUAL Thermoset III Natmar Services Company

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

UDC100 Universal Digital Controller Specifications

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

P6500W Air Dryer User s Guide

MICRO CONTROLLER S Z SERIES

IMPORTANT INSTRUCTIONS READ & SAVE

AIRREX DEHUMIDIFIER ADH-100 USER S MANUAL

Static Pressure Control

Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

IMR IX176 Portable Gas Detector User Manual

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Transcription:

www.hh.com.hk CS-652 Pneumatic Flat Press Machine Operation Manual is powered by H&H Asia Group Limited e = service@hh.com.hk t = 852.24813068 f = 852.24813727 Room 1117, 11/F, Asia Trade Centre, 79 Lei Muk Road, Kwai Chung, N.T., Hong Kong

Table of Contents Precautions with regard to Safety Name Plate Introduction Specifications Machine Components Control Console Preparation Before Main Power Connected Operation Mode Selection Machine Operation Machine Setting Control Panel Control Panel General Display Temperature Setting Adjustment Press Timer Adjustment Press Pressure Adjustment Trouble Shooting Appendix A Control Circuit Schematic Diagram issue 2 14.01.17 P.1 of 14

> Precautions with regard to Safety Please observe these safety tips for safe, efficient, an injury-free operation of your equipment. By strictly following all instruction contained in this manual you will certainly obtain an excellent performance from the use of this equipment for years. issue 2 14.01.17 P.2 of 14

> Precautions with regard to Safety (cont.) issue 2 14.01.17 P.3 of 14

> Name Plate issue 2 14.01.17 P.4 of 14

> Introduction Thank you for your choosing of CS-652 which is manufactured by H&H. The pneumatic flat press machine described in this manual is one of the sophisticated machines for processing the flat press products in the market today. Built on digital control platform and designed for the professional users. Operators are recommended to have basic knowledge and skill in heat press operation before using this machine. This manual is aimed for the operators to understand the machine and avoid damage to the machine or personnel. Please read this manual carefully and keep it well for daily reference usage. issue 2 14.01.17 P.5 of 14

> Specifications Model : CS-652 Voltage : 220 V, single phase Frequency : 50/60 Hz Power Consumption : 1000 W Compressed Air : >0.4 Mpa Heat Temperature Range : Room Temperature~260 O C Press Duration : 1~999 second, minute or hour Heat Press Size : 8 X 6 Lower Platform Size : 8 X 6 Overall Dimensions : 520mm (L) x 380mm (W) x 1050mm (H) Overall Weight : 45 kg Note : due to continuous improvement, specifications are subjected to change without prior notification issue 2 14.01.17 P.6 of 14

> Machine Components 1 2 3 4 9 5 6 7 8 7 1. press pressure adjusting knot for the cylinder 2. control console 3. heating plate & pressing head 4. safety protective bar 5. lower platform 6. machine base 7. start buttons (must press both left & right buttons to activate) 8. cancel button 9. air filter and regulator issue 2 14.01.17 P.7 of 14

> Control Console 2 3 1 4 1. Main Power Switch On / Off the Main Power 2. Led Light Switch On / Off the Led Light 3. Heater Switch On / Off the Heater 4. Control Panel Set the heat temperature setting & press time issue 2 14.01.17 P.8 of 14

> Preparation Before Main Power Connected 1. Compress air connection Since the heating plate will go up after compress air connected, the cable ties on the heating plate and the working table should be removed first. 2. Main power connection The main power cable with plug is located at the back of the machine, plug into the main power supply socket. 3. Foot switch connection The foot switch socket is located at the back of the machine, plug in the foot switch connector and tighten the screws. > Operation Mode Selection The machine has two operation modes: A. Manual Push Button Mode Press both the left & right start buttons at the front, the heating plate goes down, the timer starts to countdown. Once the timer is up or when you press the cancel button at the middle, the heating plate goes up. B. Pedal Control Mode Step on the left foot switch, the heating plate goes down, after move away the foot, the timer starts to countdown. When the countdown is completed or you step into the right pedal, the heating plate goes up. 1 2 Pedal Switch issue 2 14.01.17 P.9 of 14

> Machine Operation 1. After connected the main power supply, adjust the heating temperature and time, press pressure, and planning the machine operation method (push buttons/pedal). Then turn on the heater power, the temperature of the heating plate will go up gradually. 2. Wait until the heating plate reaches the preset temperature. Place the cloth on the working table and step on the left foot switch once or press the start buttons at the front, the heating plate will goes down. The timer will be triggered simultaneously. After the countdown finished, the heating plate will go up. The press cycle is completed. 3. If you step on the right foot switch once in the duration of countdown or press the cancel button at the front, the timer will stop immediately and the heating plate will go up, the press cycle will be terminated. 4. While the machine is working, the heating plate will go up automatically once the safety bar is triggered. 5. Switch off the main power after all the works are finished.. issue 2 14.01.17 P.10 of 14

> Machine Setting >> Control Panel 1 2 3 4 5 1. PV : Field processing temperature 2. SV : Set target temperature 3. SET : Select different settings 4. OUT1 : decrease the set point 5. OUT2 : increase the set point. >> Control Panel General Display General appearance of the control panel is as the following diagram. issue 2 14.01.17 P.11 of 14

> Machine Setting (Cont.) >> Temperature Setting Adjustment Press the #3 (SET) once, the display will alike the below diagram. PV will show with SH and SV will show the preset temperature setting. You can press the OUT1 to decrease or OUT2 to increase the temperature setting. This machine is using degree C Celsius, the maximum setting is 400 C (we recommend the temperature setting below 260 C as a higher temperature will decrease the life span of the machine). >> Press Timer Adjustment Press the #3 (SET) once again, the display will alike the below diagram. PV will show with St and SV will show the preset press time setting. You can press the OUT1 to decrease or OUT2 to increase the time setting. This machine is using second as the counting unit, the maximum setting is 999 seconds. Press the #3 (SET) again, it will back to normal display mode. >> Press Pressure Adjustment A. Turning the knob on the compress air filter regulator to adjust the press pressure. B. Turning the press pressure adjusting knot for the cylinder to adjust the press pressure. C. By adjusting the four adjustment screws below the working table, the pressure of the press can also be changed, even under the same air pressure setting. issue 2 14.01.17 P.12 of 14

> Trouble Shooting Problem Cause solution No power to individual parts Temperature monitor unsteady Temperature monitor showing the ambient temperature Heater temperature cannot raises up Fault with power cord or plug Circuit breaker tripped Main power supply not switch on Bad contact Transformer fault Thermocouple fault Thermocouple connection is loosen Temperature controller malfunction Thermocouple extension cable short circuit Thermocouple installed in wrong position Heater not started up Thermocouple fault Power supply voltage unsteady Solid state relay (SSR) malfunction Compressed air pressure too low and interlocked Check the power connection Reset the breaker and investigate the system Switch on the main power supply Check the circuit if there is any loosen part Check the voltage of power supply Replace the temperature sensor Check and tighten the connection Replace the circuit board in the control box Check the break point and repair Check the end point of the sensor and relocate the position of it Press the heat button Replace the thermocouple Install voltage stabilizer Replace the SSR Increase the compressed air pressure issue 2 14.01.17 P.13 of 14

Appendix A. Control Circuit Schematic Diagram Cancel switch +24V Safety Bar On / Off Right Foot-Switch On / Off Start button left Start button right Left Foot-Swi tch On / Off Contactor Contact Point Contactor Solenoid Valve Timer 24V issue 2 14.01.17 P.14 of 14