AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Similar documents
AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

automatic FiReFighTing SYSTeMS in PainT booths

THE IDEAL SOLUTION FOR KITCHENS

FOREFRONT AT THE OF PROTECTION

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

PROTECCIÓN DE RIESGOS ESPECIALES AUTOMATIC FIREFIGHTING SYSTEMS IN VEHICLES. con tubo de detección

SAFETY THE BEST FOR YOUR EQUIPMENT

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

What is HI-FOG? The natural enemy of fire

Performance Based Fire Protection With Water Mist

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Fire Safety Checklist

Fire suppression systems for server rooms and data centres

FIGHTING FIRE as easy as blowing out a match

REDUCING HARVEST FIRES. grdc.com.au 1

Fire protection for buildings

Fire Safety Awareness at Work. Unit 3

Fire Safety Workbook

Fire and Life Safety Review Form

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

FIRE RISK ASSESSMENT Self Assessment

So what is a fire hazard?

Why is this important?

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

5 Key Stages to Risk Assessment

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Fire Risk Assessment

Fire Safety PPT-SM-FIRESFTY V.A.0.0

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

IFE Level 4 Certificate in Fire Science and Fire Safety

Loss Prevention Standards

Health Care Engineers Fire & Life Safety Boot Camp

FIRE SAFETY AND PREVENTION POLICY

HART XL High Sensitivity Smoke Detection

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Fire Suppression Systems

Fire Risk Assessment

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Fire Safety Awareness Workbook

CO2 COCO GAS FLOODING SYSTEM

Cadet Entry Level Award(ELA) Part Four. Fire Safety

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

HART XL High Sensitivity Smoke Detection

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

The Social Accountability International (SAI) Fire Safety Checklist

Fire Safety. Version 1.0

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Element C3.4 Fire Fighting Equipment

Ensuring safe passage HI-FOG for underground stations

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

Five London Hospital Fires: Report by Philip Gibbs, LFB. For internal training use only.

Institute for Plasma Research Welcomes you all on

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

Technical Information

Agency for Health Care Administration

Installation and Maintenance Requirements

Agency for Health Care Administration

CO 2 Fire Extinguishing Systems

REDUCING HARVESTER FIRE RISK THE BACK POCKET GUIDE

Fire fighting Questions

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Fire protection on chemical manufacturing sites

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Case study: EconAqua water mist sprinkler system

City of Leduc Fire Services Indoor Special Event Requirements

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

ST. JOHN HEALTH SYSTEM PHYSICIAN SAFETY MANUAL

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

FIRE SAFETY FOR INDUSTRIAL WORKERS

High flying fire protection HI-FOG for aircraft hangars

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Tel: Mecca Street Bldg 194, Amman, Jordan Mob:

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Township of Upper Providence Office of the Fire Marshal

Fire Prevention Plan Program

Fire Prevention. Risk Management Services. October 7-13, 2012 National Fire Prevention Week National Fire Protection Association

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Risk Management of Fire using Video Based Detection

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

Fire Enforcement Report

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply

Chapter 18 Welding Table of Contents

National Fire Authority

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

SPRINKLER MYTHS. MYTH: In a fire all the sprinkler heads go off together. FACT: Only the sprinkler head(s) directly affected by the fire is triggered.

Transcription:

SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Protection for all areas Our goal: safety Possible solutions require a detailed study of the actual conditions and taking stronger measures to protect our hospital infrastructure. Hospitals are large building and facility complexes that leverage technical and human resources to offer the services they provide, including kitchens, pharmacies, HVAC, miscellaneous equipment warehouses, etc. Hospitals grow and adapt to the population they serve, increasing their capacity, medical services and equipment as required. In many cases these adaptations involve extensions. In others, they may involve refurbishing internal areas for other uses or upgrading technology, engineering and architectural elements. Comfort and efficiency are directly correlated to more spacious, more attractive, and more accessible facilities, as well as new engineering solutions. New conditions result in new needs, including the need to be in safe buildings adapted to hazards that may exist at any given moment. A highimpact factor to consider is the possibility of a fire and having to evacuate the building, since occupants for the most part are unfamiliar with the building and have diminished physical abilities. In the past, major fires in hospitals have resulted in serious consequences and significant loss of human life and material damage. Statistics show that the fire brigade response time can be long, around 10 or 15 minutes, so additional protection measures may be required.

Source of fire Hospital facilities include facilities which can start various types of fires in various places. Some of the potential fire sources are shared with other public buildings, such as boiler rooms, record rooms, kitchens, etc. and other areas specific to hospital use. The greatest fire hazards in a hospital, and thus where proper strongest firefighting equipment performance is required are as follows: COMMON SPACES: corridors/rooms/waiting rooms/etc. OPERATING THEATRES LABORATORIES KITCHENS RECORD ROOMS AND WAREHOUSES TECHNICAL AND SERVER ROOMS TRANSFORMERS LAUNDRIES The main fire sources in hospitals are: The hospital rooms and kitchens. Technical faults in electrical, pneumatic and mechanical equipment. Arson. Special Warning There are other risk factors in each room which equally important and can cause or help spread the fire. These are very different: Easily ignitable material: such as curtains, bedding, clothes lockers, mattresses, foam chairs, etc. Electrical outlets for various applications, such as those used for mobile phone chargers, laptops, video players, heaters, etc. Combustible gases, used for cooking or heating, generally using LPG, town gas and natural gas. Medicinal gases, such as oxygen and nitrous oxide, key in sustaining combustion. Moreover, HVAC systems may carry smoke from a fire from one area to others.

CUSTOM SOLUTIONS MAIN AREAS: ROOMS / CORRIDORS / OPERATING ROOMS / WAITING ROOMS / ETC. The sophisticated technologies used and the wide range of existing equipment, especially in operating rooms, are susceptible to short circuits and malfunctions, and thus pose a threat to people s lives. The solution for continuous protection is installing a water mist system in hospitalization and patient care wards. With this system, fires will be controlled at an appropriate stage without additional risk to property and personnel. It is a technology used for many applications and is compatible with electrical and combustible equipment and therefore suitable for high-risk areas, not just public spaces such as rooms and corridors. Such systems require less water, up to 85% less than traditional sprinkler systems, which results in the installation of smaller diameter pipes and thus require less space. The flexibility of this equipment makes it easy to adapt to modern new hospitals, as well as the refurbishing of existing ones. The required pipe, AISI 316L, is stainless steel and ensures a clean discharge that meets hygiene standards required in this type of buildings. LAUNDRIES The protection of this type of enclosure should not be underestimated. The coexistence of industrial machinery with other hazards can be very dangerous. These areas house significant fire points, such as highly flammable cleaning products and various types of fabrics, usually in storage. The common protection system for this type of premises is water mist.

KITCHENS The kitchen is one of the areas of a hospital that should be given the greatest attention from a fire safety standpoint due to the existence of highly combustible fats, oils that generate flammable vapours, many types of materials and the variety of sources of ignition. Smoke from oil fire can seriously affect the performance of many areas of a hospital. Although regulations require compartmentalization, if it is not done perfectly, smoke will extend into other areas, leaving them unused and spreading the fire. SIEX has a system specifically designed for this type of protection: SIEX-KP TM. It fully covers all possible fire points, such as exhaust fans, ducts, filters and cooking appliances such as grills, fryers, broilers, etc. An added advantage over other similar systems is that the equipment can be activated both electrically and mechanically, adapting to customer needs. KP LABORATORIES Hospital labs are another area where protection is recommended. Fires can be started by electrical faults or improper use of certain chemical elements or equipment. Fire can destroy increasingly sophisticated and modern equipment (significant investments) so protection is becoming more and more important. Fire protection also prevents the loss of relevant patient information. For these cases, SIEX has different extinguishing systems, depending on the type of risk and existing installation. To protect against electrical fires, common in these facilities, you can use SIEX-HC TM chemical gases, INERT-SIEX TM inert gases or water mist systems, depending on the various conditions and needs.

RECORD ROOMS AND WAREHOUSES Hospital record rooms are a hazard which do not involve any danger per se, but if the stored documents catch fire, consequences are very significant in the short, medium and long term. It must be borne in mind that hospital records not only include patient medical records but varied other documents, such as X-rays, video library, medical books, historical and significant files, patient record books, administrative records, relevant journals, etc. Losing these documents would involve cancelling and delaying surgical procedures, repeating medical tests (some of them very expensive), losing information, and so on. The fire load in this type of location is inherently high, given the high concentration of combustible items such as paper, cardboard and electrical components which may become faulty. Materials on shelves, ceilings, floors and other possible materials represent an additional fire load. These hazards can be protected by water mist systems (SIEX TM WATER MIST SYSTEM), halocarbon gases (SIEX-HC TM ) or inert gases (INERT-SIEX TM ). TRANSFORMER AND GENERATOR ROOMS These rooms deserve significant specific protection in medical applications. Transformers supplying the precise electrical power required for daily operation and electric generators ensure continuity of critical services in the event of power cuts. This emergency backup supply is critical for the proper performance of operating rooms and life support equipment, among others. The protection of generators and transformers and their enclosure is therefore essential. The enclosure must be isolated by 60-min fire-resistant construction elements. These are areas with combustible oils, liquids and gases that are highly flammable with fast-spreading flames. They can be protected by local application water mist or CO 2 systems, inert gases (INERT-SIEX TM ) or dry chemical systems (SIEX TM IND). An analysis of existing openings must be carried out in order to determine the most appropriate system for each application.

TECHNICAL AND SERVER ROOMS Technical and server rooms are strategic areas of the hospital. They store all information related to processes, patients, staff, protocols and general operations. Our commitment CHOICE OF SYSTEMS SIEX has the widest range of products and systems to suit different needs, both as regards pressures and extinguishing agents. In case of fire, losses are valued not only by the material value of the equipment, but are significantly greater when the chain reaction that occurs is taken into account: loss of stored information, often irrecoverable; loss of productive time, delays in interventions and treatments and even losses incurred as a result of time spent on reacquiring lost information. COMPETITIVE PRICE Optimizing all of our processes make us more and more competitive worldwide. The main causes of fire that may occur in this type of facility are: sparks due to switches, short circuits, overloads, static electricity, dirt or external elements that might cause flaming from overheating, etc. It must also be borne in mind that the vast majority of technical equipment rooms have false ceilings and floors, through which electrical wiring carries both power and information. These must be protected, since they are potential sources of fire with limited potential for visual inspection. SPECIALIZED ENGINEERING Our highly qualified staff ensure the best service for customers both as regards technical advice on the choice of system, and solving any problems that might arise after installation. Backed up by our extensive experience and a track record of successful projects. INNOVATION The most appropriate system will be selected based on the size of the hazard(s) to be protected, space available for storage, location of equipment, financial cost, piping installation, as well as various customer needs. At the forefront of innovation in every product we develop, ensuring the technical features offered. QUALITY GUARANTEE SMALL ROOMS MEDIUM ROOMS LARGE ROOMS All products meet the highest quality INERT-SIEX TM SIEX-HC TM 227 INERT-SIEX TM INERT-SIEX TM CONSTANT INERT-SIEX TM SIEX TM WATER MIST requirements and internationally recognised official approvals. SIEX-NC TM 1230 FLOW TECHNOLOGY SYSTEM SIEX-HC TM 227 S-FLOW SIEX-HC TM 227 works in a diverse range of pressures: from 25 to 60 bar.

OTHER SPECIAL HAZARDS PROTECTING BY SIEX: SERVICE STATIONS ARCHIVES AND LIBRARIES DPCs Paint Spray Booths electrical panels industrial kitchen turbines and generators road tunnels NATURAL GAS PLANTS CLEAN ROOMS CABLE TUNNELS Telecommunication centres HOTELS HOSPITALS Educational establishments Train and underground stations TRAINS TRANSFORMERS OFFSHORE PLATFORMS Solar Thermal Plants MACHINE TOOLS PRINTING INDUSTRY HISTORIC BUILDINGS ROBOTIC PARKINGS WIND TURBINES STEEL INDUSTRY BANKS OFFICES LARGE VEHICLES CONVEYOR BELTS GAS PUMPS OIL & GAS TIMBER INDUSTRY C/ Merindad de Montija, 6 P.I. Villalonquéjar 09001 Burgos (SPAIN) tlfno: +34 947 28 11 08 fax: +34 947 28 11 12 siex@siex2001.com www.siex2001.com 1609