BFM Balanced flue commercial water heater

Similar documents
BFC Cyclone Condensing Glass-Lined Water Heater

SGE Condensing Gas - Solar Water Heater

SGS Condensing High Efficiency Gas-Solar Water Heater

BFM. Balanced Flue Commerial Water Heater BFM - 30/50/80/100/120. Installation, User and Service Manual. Innovation has a name.

Boiler systems Upsilon Cascade. Innovation has a name.

ADMP. Commercial Atmospheric Water Heater ADM - 40/50/60/80/90/115. Installation, User and Service Manual. Innovation has a name.

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity



Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

CBX 24, 32 & 38 SBX 30

United Kingdom & Ireland

INSTALLATION - AND USER INSTRUCTIONS

VAILLANT SPARE PART CATALOGUE

MAINTENANCE AND SERVICE GUIDE

GAS AIR HEATER RANGE

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

INSTALLATION AND USER INSTRUCTIONS

United Kingdom & Ireland

kw Btu/h Metres Feet l/min. Gal/min C C

Performa System 12e, 18e, 24e & 28e

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

... UDSA - UDSBD Gas fired unit heaters...

1 VICTRIX ZEUS Superior kw I features

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Installation & Servicing Instructions

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Knight. Installation, Commissioning, User & Maintenance Instructions. Traditionally Gas Fired Single Flue Water Heater with Pilot Ignition

Powerstock Storage Tank

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Alpha CombiMax 350 and 600

24 VAC SYSTEM CONTROL KIT

/13 Price - $5.00

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Power Direct Vent PDV(S&T) Models

Copper-Fin GAS-FIRED WATER HEATERS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Gas-fired unit heaters for indoor installation

RAYPAK HOT WATER & HEATING

ADVANCE ECB ELECTRIC COMBINATION BOILER

PrecisionTemp Shower-Mate

RAYPAK HOT WATER & HEATING

Replacement Parts List

Installation and Servicing Instructions. Alpha CB50

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

CNTENTS. 1Introduction

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

THELIA IN WARRANTY TECHNICAL HELPLINE THIS IS A CAT II2H3+ APPLIANCE

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

24 VAC SYSTEM CONTROL KIT

BENSON GAS UNIT HEATERS

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Hamworthy Dorchester DR-FC Evo 98%

thermocompact High performance system boiler range

Knight Gas Fired Single Flue Water Heater with Pilot Ignition

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

MODEL BTI 65 G InsTALLATIOn AnD user InsTRucTIOn united kingdom / IRELAnD HOT WATER storage HEATER

GB Condensing Gas Boiler

STREBEL S-CB + Cascade Kits

15B Cast Iron Gas Fired Boilers For Forced Hot Water

Broag Pressurisation equipment

24SiII / 28SiII WALL MOUNTED COMBINATION BOILERS FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER

FERROLI F30 INSTALLATION, SERVICING AND USER INSTRUCTIONS G.C. NO: Appr. nr. B99.06 A - CE 0461 BM /0-07/2001

ecomax pro High efficiency condensing boiler range for traditional systems

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Installation and Servicing Instructions. Alpha CD50

DOMINA 102 COPPER WALL-MOUNTED COMBINATION, GAS FIRED BOILER FOR CENTRAL HEATING

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Finest. HALSTEAD Finest Finest Gold INSTALLATION & SERVICING INSTRUCTIONS FOR THE

Figure 10 or Figure 6

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Residential & Commercial

Columbia Boiler Company

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Technical Documentation

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

MASTERTEMP HEATER REPLACEMENT PARTS

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Energy Saver Commercial Gas Millivolt (DM) Models

DOMINA 102 DGT INSTALLATION, SERVICING AND USER INSTRUCTIONS G.C. NO: Appr. nr. B99.06 A - CE 0461 AU /1-07/2001

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592

LGB Gas fired boiler

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

HeatMaster. Installation, operating and servicing instructions. HeatMaster 71 HeatMaster 101 HeatMaster 201 ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

INSTALLATION AND SERVICING INSTRUCTIONS

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Bosch Group. 24CDi OF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS

A/23 MFFI - A/27 MFFI

Transcription:

Balanced flue commercial water heater BFM 30/50/80/100/120 ide range of balanced fanned flue room-sealed water heaters for installation in almost any location Improved efficiency Removable control column for convenient servicing Control, high limit and energy cut-off thermostat triple protection ensures safe operation Frost-protection thermostat Stainless-steel burner for natural or LP gas Two access covers for comprehensive waterside tank maintenance oltage-free contact for general fault indication Steel pallet base for convenient transport and installation Optional ancillaries: Unvented kits Destratification pump kit Powered anode Innovation has a name.

Technical specifications Gas data natural gas 2H (G20) Input* k 32.2 52.2 83.3 113.3 127.7 Output k 26.4 42.3 67.5 90.8 102.4 Inlet pressure mbar 20 20 20 20 20 Burner pressure mbar 12.5 12.9 12.9 12.5 14.0 Gas consumption** m3/h 3.1 5.0 7.9 10.8 12.2 Diameter pilot orifice mm 0.56/0.41 0.56/0.41 0.56/0.41 0.56/0.41 0.56/0.41 Diameter main orifice mm 2.6 2.5 2.7 3.2 3.3 Max. flue gas temperature C 130 150 145 180 185 Flue gas discharge kg/h 74.2 105.7 191.9 232.5 265.8 Gas data butane 3+ (G30) Input* k 31.4 49.9 81.3 110.5 n/a Output k 26.4 41.4 67.5 90.8 n/a Inlet pressure mbar 50 50 50 50 n/a Burner pressure mbar - - - - n/a Gas consumption** kg/h 2.3 3.6 5.9 8.0 n/a Diameter pilot orifice mm 0.25 0.25 0.25 0.25 n/a Diameter main orifice mm 1.25 1.25 1.3 1.7 n/a Max. flue gas temperature C 130 150 145 180 n/a Flue gas discharge kg/h - 98.6 187.8 228.7 n/a Gas data propane 3+ (G31) Input* k 30.4 47.8 77.2 110.9 125.0 Output k 25.5 39.6 63.9 90.8 102.4 Inlet pressure mbar 37 37 37 37 37 Burner pressure mbar - - - - 22 Gas consumption** kg/h 2.2 3.4 5.5 7.9 8.9 Diameter pilot orifice mm 0.25 0.25 0.25 0.25 0.25 Diameter main orifice mm 1.45 1.4 1.5 1.95 2.3 Max. flue gas temperature C 130 150 145 180 185 Flue gas discharge kg/h 71.4 105.1 194.3 232.0 264.7 Draw-off capacity Storage capacity l 309 298 253 253 253 Max. temperature setting C 73 73 73 73 73 30 min. T=44 C l 569 697 870 1074 1176 60 min. T=44 C l 827 1111 1529 1962 2176 90 min. T=44 C l 1085 1524 2189 2849 3177 120 min. T=44 C l 1343 1937 2849 3736 4177 Continuous T=44 C l/h 516 827 1319 1774 2000 Heating-up time T=44 C min. 36 22 12 9 8 30 min. T=50 C l 501 613 765 946 1035 60 min. T=50 C l 728 977 1346 1726 1915 90 min. T=50 C l 955 1341 1926 2507 2796 120 min. T=50 C l 1182 1705 2507 3288 3676 Continuous T=50 C l/h 454 728 1161 1561 1760 Heating-up time T=50 C min. 41 25 13 10 9 30 min. T=55 C l 455 558 696 860 941 60 min. T=55 C l 662 888 1223 1569 1741 90 min. T=55 C l 868 1219 1751 2279 2541 120 min. T=55 C l 1074 1550 2279 2989 3342 Continuous T=55 C l/h 413 661 1055 1419 1600 Heating-up time T=55 C min. 45 27 14 11 9 Electrical data Power consumption 100 100 100 275 300 Power supply AC/Hz 230 (-15/+10%) / 50 General Pressure differential Pa 200/170 270/240 255/225 610/580 220/190 Diameter of air restrictor mm 36 42 54 48 64 Anodes - 2 2 4 4 4 Maximum working pressure bar 8 Maximum weight kg 539 543 548 573 573 Shipping data eight empty kg 230 245 295 320 320 eight incl. packaging kg 260 275 325 350 350 idth packaging mm 800 800 800 800 800 Height packaging mm 2080 2080 2080 2080 2080 Depth packaging mm 1040 1040 1040 1040 1040 * Gas data on gross value ** Gas consumption at 15 C and 1013.25 mbar

Dimensions -80 A 2000 2000 2020 2020 2020 B 1800 1800 1820 1820 1820 C 580 580 580 580 580 D 710 710 710 710 710 E 1000 1000 1000 1000 1000 F 755 755 755 755 755 G 125 125 150 200 130 Hy - - - 235 235 K 600 600 600 600 760 L 125 150 200 130 130 M 600 600 590 590 590 N 1640 1640 1655 1655 1655 P 770 770 760 760 760 R 550 550 540 540 540 S 1600 1600 1600 1600 1600 1 Cold water (external) R1 1 /2 2 Hot water (internal) Rp1 1 /2 3 Gas control (internal) Rp 3 /4 (BFM120 = Rp1) 4 Tank drain valve (internal) R1 1 /2 5 T&P valve (internal) 1-11.5 NPT (-50) Rp1 1 /2 (-120) 6 Cleaning and inspection opening Ø100 Dimensions in mm. All BFM water heaters receive a three years warranty on the tank and one year on parts. -120

Installation diagrams ented 1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 7 Destratification pump 9 Drain valve 10 Gas cock 11 Isolating valve 12 Temperature gauge 13 Condense drain 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 ater tank 19 Float valve Unvented A B C D E H Cold water Hot water Return circulation Gas supply Overflow pipe Expansion vent pipe A.O. Smith unvented system kits utilise combination valves. Further installation and connection details can be found in the Installation & Commissioning Manual.

Electrical diagram A = Jacket B = Isolating transformer C = APDS (Air pressure differential switch) C = Filter E = Reset button F = Frost thermostat G = Control thermostat H = ON/ OFF switch K = Safety thermostat L = High-limit thermostat M = Burner control N = Connector clip strip P = Earthing strip R = Clock (optional) S = Relay T = Potentiostat (optional)

Flue systems BFM Installation options A BFM water heater should be installed according category C13 or C33. C13 C13 Concentric x x x - - Parallel - - - x x Diameter (mm) 80/125 100/150 130/200 2 x 130 2 x 130 Max. length (m) 7 7 7 7 7 Max. 45/90 bends a pipe 2 2 2 2 2 Concentric flues It is not permitted to use more than the specified number of bends, even when the duct is shorter than the maximum length. A 45 bend is equivalent to a 90 bend. Parallel flues The parallel flue of a of 120 unit should always be connected to the wall or roof penetration using the standard transition piece (0306801). The two ducts shall not terminate in different pressure zones. C33 C33 Note: horizontal flue runs must be installed with a fall of at least 5 mm per metre. Flue systems BFM Minimum space requirements -80 Y Y Ø80/125 Ø100/150 Ø130/200 2 x Ø130 2 x Ø130 Minimal space for wall duct (mm) 550 550 640 725 790 940 X 2115 2165 2190 Y 1195 1215 1310 Y * 745 765 860 X X 700 700 1000 1000 X1 2480 2480 Y1 955 955 X2 2140 2140 Y2 1320 1320 Y2 * 870 870 Minimal space for roof duct (mm) 1230 1310 1610-120 Y1 X1 Y2 X2 X Y 605 645 1000 X 3575 3615 3580 Y 1575 1615 1560 Y ** 625 665 610 2560 2560 1000 1000 X 3580 3580 X ** 2630 2630 Y 1560 1560 Y ** 610 610 For the parts numbers of components and flue gas ducts, etc. * Distance without concentric pipe between bend and wall duct. ** Distance without concentric pipe between appliance and roof duct. Data subject to change UK/0109/BFM/01 Terms and conditions apply, please refer to our website. ater Heaters A.O. Smith ater Heaters, Unit B8 Armstrong Mall, Southwood Business Park, Farnborough, Hampshire, GU 14 ONR www.aosmith.co.uk A.O. Smith ater Heaters is a trading name of Advance Services (Sales) Ltd. Reg.