MDX² INSTALLATION MANUAL

Similar documents
SAFETY VACUUM RELEASE SYSTEM (SVRS)

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM

U.S. Patent No.: 4,114,206, 4,939,797, 5,135,579, 5,251,343, 5,265,631

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM

DIAMOND STRIP DRAIN OWNER S MANUAL VGB 2008 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

ULTRA STRIP DRAIN OWNER S MANUAL VGB 2008 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

SMF PUMP OWNER S MANUAL

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

CHAMPION PUMP OWNER S MANUAL

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

QUIETFLO OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

SuperFlo High Performance Pump

IMPORTANT SAFETY INSTRUCTIONS

Jacuzzi J-D300 Pool Cleaning System

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Elite Primer Baldor Series External Pond Pump

Intelligent Variable Speed Pump

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev -

OWNER S MANUAL IMPORTANT SAFETY RULES. Deluxe Maintenance Kit IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

OWNER S MANUAL IMPORTANT SAFETY RULES IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS. Super Pump Series

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

HIGH PERFORMANCE PUMP

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Vac-Alert TM Industries, LLC

WATER PURIFYING SYSTEM

INSTALLATION INSTRUCTIONS WARRANTY

Installation, Operating, and Service Manual. Badu. EcoM3. Swimming Pool Pump

POOL & SPA SUCTION FITTINGS

Patriot. Automatic Pool Vacuum Cleaner. Patent No. 5,794,293. Owner's Guide. Model *Recommended for 3/4 HP and above

SwimPro by HAYWARD 620 Division Street Elizabeth, NJ Tel:

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

LIL SHARK TM AUTOMATIC POOL CLEANER. Model GW8000 OPERATION, TROUBLESHOOTING & PARTS. About Safety

Owner s Guide and Installation Manual

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

HIGH PERFORMANCE 3-PHASE PUMPS

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

HAYWARD POOL PRODUCTS POMONA, CA CLEMMONS, NC NASHVILLE, TN

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

SYSTEMS for CATALYTIC FILTERS

Owner s Guide and Installation Manual

HIGH PERFORMANCE PUMPS

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

5HP CYCLONE DUST COLLECTOR MANUAL

Owner s Guide and Installation Manual

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

Owner s Guide and Installation Manual

AQUA-FLO A SERIES. The Bronze Pump designed exclusively for any swimming pool or spa application.

OPERATING MANUAL HYDRO POWERED ROBOTIC POOL CLEANER CONTENTS

MODEL E

HYDROGEN SULFIDE REMOVAL SYSTEMS

Pump - Owner s Manual

Owner s Guide and Installation Manual

CHALLENGER CENTRIFUGAL PUMP

! WARNING. Before using product, read and understand instructions.

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

S5 SUCTION SIDE POOL CLEANER

7165 Dust Collector Owner s Manual

InterSeptor Centrifugal Separators Operating & Maintenance Manual

INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

General System Layout Sketch

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

For our present, For their future. Version 11.04

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Homeowners Manual. Thank you!

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Safety Vacuum Release System Installation Instructions. Model VA

RVAC-100 VACUUM CLEANER MANUAL. For Household Use Only

ASSEMBLY INSTRUCTIONS

Installation Instructions

! WARNING. Before using product, read and understand instructions.

VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES

CONSTANT SUCTION UNIT

GREAT WHITE II AUTOMATIC POOL CLEANER

Parts & Material Included

Installation. Please keep this manual for future reference.

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

Installation Instructions

Installation Manual PS-225 & PS-275

Inground Suction Pool Cleaner. Installation and User's Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

SS1095 Ice Maker.

Aplos Single Handle Basin Bathroom Faucet

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

Transcription:

ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL CONCRETE POOLS SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA AND FLORIDA ON PAGES 4 AND 5 Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ASME A112.1.8-2007 U.S. Patent No.: 6,810,537, 7,08,607, 7,178,17 Notice to Installers: Read and follow these instructions. Give these instructions to the facility owner to keep for future reference. Follow all codes and regulations that apply to the design, installation and use of suction outlet fittings. - WARNING: MDX² and must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. MDX0804 004-027-873-00 REV03050 25 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.83.7607 Fax: 480.753.337 paramount@1paramount.com www.1paramount.com

IMPORTANT NOTICES: PLEASE READ WARNING KNOWN DROWNING HAZARD. DO NOT GO NEAR THE SUCTION FITTINGS OR DRAINS OF YOUR POOL OR SPA. YOUR HAIR OR BODY MAY BECOME TRAPPED CAUSING PERMANENT INJURY OR DROWNING. DO NOT ENTER THE POOL OR SPA IF SUCTION FITTINGS OR DRAIN COVERS ARE LOOSE, BROKEN, OR MISSING. INSPECT SUCTION FITTING INCLUDING FASTENERS FOR DAMAGE ON TAMPERING BEFORE EACH USE OF THIS FACILITY. WARNING RISK OF SEVERE INJURY OR DROWNING IF SUCTION SYSTEMS ARE NOT INSTALLED PROPERLY! NOTICE TO OWNER: READ, FOLLOW, AND KEEP THESE SAFETY INSTRUCTIONS FOR FUTURE REFERENCE. WARNING THIS POOL MAY HAVE VENT TUBES AS A LAYER OF ENTRAPMENT ADVOIDANCE ON THE SUCTION OUTLETS! IF A VENT TUBE IS INSTALLED ON THIS SYSTEM ATTACH THE ENCLOSED WARNING LABELS TO THE VENT PIPE AND CONTROL PANEL AS INSTRUCTED ON PAGE OF THIS MANUAL. IF THIS POOL HAS BEEN WINTERIZED THE VENT MUST BE INSPECTED WHEN STARTING THE POOL FOR THE SEASON. REMOVE THE PLUG FROM THE ATMOSPHERIC VENT PIPE BEFORE ENERGIZING THE POOL PUMP(S)! TEST THE VENT BY BLOCKING THE DRAIN. AIR SHOULD ENTER THE PIPE AND CAUSE THE PUMP TO CAVITATE RELEASING THE SUCTION ON THE DRAIN BLOCK. Suction can pose a serious hazard to swimmers just as electricity can be a hazard. Both are important for proper water filtration and both must be treated with respect. Suction safety begins with a professional design that includes a quality suction system installed by a certified contractor. The MDX² Anti-Entrapment Debris Drain is only available to certified contractors for the same reason certified electricians are required to connect filtration pumps to public utilities; both require proper training and certification to assure no hidden hazards are built into the project. Certified builders will address the following issues when designing and installing a proper filtration system: Properly bond-grounded pumps, time clocks, switches and any other metal in or near water. This is required to address Electrical Shock Hazards. Design the suction piping so there are no single-point suction hazards; single-point suction (one drain) is a leading cause of Body Suction Entrapment Hazards. Note: your certified builder has many effective options for addressing this hazard; they may include dual-drain systems, like MDX², skimmers, gutters, negative edge features and many more products and piping designs known to professionals. Install ASME A112.1.8-2007 listed drains, suction covers and debris removal systems. This is the ONLY approved option for preventing Hair Entrapment Hazards, the leading cause of suction related injuries. Design and install an effective circulation system (including optional cleaning systems), to direct filtered water to all areas and interior surfaces. NOTE: Suction fittings can NOT clean or direct filtered water for proper sanitation; that can only be done on the pressure (return) side of the filtration system. While suction injuries are extremely rare, drowning and diving injuries are far too common and there is little your certified builder can do to eliminate these hazards. You must educate yourself and your guests. Below are some important safety issues every swimmer must know and recognize. PREVENT DROWNING: Watch children at all times, no swimming alone. NO DIVING IN SHALLOW WATER: You can be permanently injured. PREVENT SUCTION ENTRAPMENT: Inspect suction covers before swimming, keep swimmers away from suction fittings, protect long hair, don t swim with loose clothing or large and dangling jewelry. WARNING: MDX² and must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. 2006, Paramount Pool & Spa Systems

MDX² INSTALLATION MANUAL System Design: NOTICE: WARNING: MDX² and must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. These MDX² instructions provide two methods to choose from, with additional methods for specific jurisdictions, (California and Florida specifically but not limited to those states). Your local codes may require additional safety measures. Paramount Pool & Spa Systems and its representatives cannot recommend or endorse installation methods other than those provided in these MDX² instructions. NOTICE Maximum Pump Size: MDX² is rated for a maximum of 0 GPM (340 LPM). While system flow rate will vary with pump size and the Total Head Loss for a given system, virtually any modern pump is capable of exceeding this limit, therefore it is the responsibility of the system designer to make sure it is not possible to exceed 0 GPM (340 LPM). In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system. MDX² INSTALLATION MANUAL NOTICE: 18 inches of 2½" pipe is required to be connected to the center outlet of the MDX². After the 18 inches of 2½" pipe you may reduce to a smaller pipe size, although it is not recommended. Use of 2½" pipe throughout the suction side of the system is strongly encouraged for optimum performance. For your convenience, Paramount Pool & Spa Systems includes the 18 inches of 2½" pipe plus tee with the MDX². To order separately, please see page 10 for the part number. Anti-Entrapment Debris Drain STANDARD POOL DESIGN Dual Drain MINIMUM Design Flow Rate = 0 GPM Maximum GPM = 0 OR LARGER CIRCULATION LINE X 18" TEE SECOND DRAIN ANY ORIENTATION Velocity at 0 GPM = 1.368 FPS For technical assistance call 1-800-621-5886 or contact your regional representative. 1

FLOW HEAD Flow vs Head LOSS Loss CURVE 2.50 2.00 Head Loss (inhg) 1.50 1.00 0.50 0.00 30 40 50 60 70 80 0 100 110 120 130 140 150 Flow (GPM) MDX² INSTALLATION WITH CANISTER WITHOUT CANISTER Installation Method 1: 5 FT. MIN. 5 1/2 FT. MAX 5 FT. MIN. 5 1/2 FT. MAX. PLUG SIDE PORT X 18" METHOD 1 WITH CANISTER, WITH VENT PLUG SIDE PORT X 18" METHOD 1 WITHOUT CANISTER, WITH VENT PLUG SIDE PORT X 18" METHOD 1 WITH CANISTER, WITHOUT VENT PLUG SIDE PORT X 18" METHOD 1 WITHOUT CANISTER, WITHOUT VENT 2

WITH CANISTER MDX² INSTALLATION WITHOUT CANISTER Installation Method 2: PLUG SIDE PORT MDX2 X 18" METHOD 2 CA WITH CANISTER, WITH VENT 5 FT. MIN. 5 1/2 FT. MAX PLUG SIDE PORT X 18" MDX2 METHOD 2 CA WITHOUT CANISTER, WITH VENT 5 FT. MIN 5 1/2 FT. MAX PLUG SIDE PORT X 18" METHOD 2 CA WITH CANISTER, WITHOUT VENT MDX2 PLUG SIDE PORT X 18" METHOD 2 CA WITHOUT CANISTER, WITHOUT VENT 3

MDX² CALIFORNIA INSTALLATION WITH CANISTER Installation Method 1 (California): 5 FT. MIN. 5 1/2 FT. MAX WITHOUT CANISTER 5 FT. MIN. 5 1/2 FT. MAX. PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITH CANISTER, WITH VENT PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITHOUT CANISTER, WITH VENT CALIFORNIA PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITH CANISTER, WITHOUT VENT Installation Method 2 (California): 5 FT. MIN. 5 1/2 FT. MAX PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITHOUT CANISTER, WITHOUT VENT 5 FT. MIN 5 1/2 FT. MAX PLUG SIDE PORT MDX2 X 18" METHOD 2 CA WITH CANISTER, WITH VENT PLUG SIDE PORT X 18" MDX2 METHOD 2 CA WITHOUT CANISTER, WITH VENT PLUG SIDE PORT X 18" METHOD 2 CA WITH CANISTER, WITHOUT VENT MDX2 PLUG SIDE PORT X 18" METHOD 2 CA WITHOUT CANISTER, WITHOUT VENT 4

FLORIDA MDX² FLORIDA INSTALLATION WITH CANISTER WITHOUT CANISTER Installation Method 1 (Florida): 1 1/ PLUG SIDE PORT X 18" METHOD FL WITH CANISTER, WITH VENT 1 1/ PLUG SIDE PORT X 18" METHOD FL WITHOUT CANISTER, WITH VENT NOTE: As of March1, 200 builders in Florida may use Installation Methods 1 and 2 on Page 2 and 3. 5

MDX² INSTALLATION Plumbing: 1. Position the MDX² Sump 1" below the finished depth of the interior surface of the pool, spa or basin. (Page 8, Fig. 5) Orientate the Sump so the sweep elbow is perpendicular to a side wall or endwall of pool. 2. Position the REQUIRED High Flow Safety Drain TM on a sidewall of the pool, spa or basin. The 2nd Suction Outlet may be positioned on the floor a MINIMUM of three (3) feet away from any other Suction Outlet. HYDROSTATIC FITTING: The hydrostatic port inside the MDX² Sump is equivalent to a Threaded Female Adapter and a Slip Fitting Outside the MDX² Sump. This port is for the purpose of a hydrostat only. Paramount recommends the use of the 2 thread plug provided. Do not use check valves here that are prone to sticking open causing the need to open the drain cover exposing a suction risk. If a hydrostat is not used, plug this port from bottom with pipe and cap. Do not install any suction equipment (pump) to this port! MDX² PRESSURE TESTING Pressure Test-READ BEFORE INSTALLATION: New Style Test Plug The 2 1/2 pressure test plugs (005-252-1611-00) use an o-ring to make the seal. Wrap once withteflon tape to prevent plastic threads from binding. Insert plug into threaded socket. Set plug wrench on lug and tighten by hand until snug. Over tightening may cause parts to break. Pressure should remain on the system through construction until interior cleanup. HYDROSTATIC PLUG *KEY PLUG 6 Notice: Release pressure on the system before removing plugs *Key can be removed for desired plaster ring alignment.

CONCRETE INSTALLATION The High Flow Safety Drain TM installed in a concrete shell utilizes a small cutout in the concrete to form the sump which is sometimes made of plastic or fiberglass. This concrete sump provides superior shell strength by eliminating the large hole associated with plastic sumps. The water seal is formed against the suction pipe in the same way a water tight seal is formed with return pipes. The concrete cutout is typically eleven (11) inches wide, by two (2) inches deep, with a finger size cutout around the pipe to allow room for a watertight seal. (Fig. 1) Rebar Steel (Fig. 3) Concrete reinforcing steel should be kept 3" away from all pipe and fittings. Concrete Shell Sump (Fig. 1) Form a concrete sump around each suction pipe. Concrete Shell Preparation (Fig. 2) Prior to installing the interior finish, cut each riser pipe approximately 1" behind the concrete shell's surface. Note: Suction Safety Standards require that main drain grates used to cover concrete sumps, must have the suction pipe cut at least 1 ½ times the pipe diameter behind the drain cover. This is to allow room for even water flow through all drain cover holes. This is not necessary with the drain because the Patented Design provides uniform suction regardless of pipe location. However, if the pipe is too close to the surface, it may restrict water flow to the pump, reducing hydraulic efficiency, but this does not pose a suction safety hazard. Fig. 1 11 (typ) 2 Deep (typ) Finger Size Cutout Fig. 2 1 Deep (typ) 7

CONCRETE INSTALLATION (CONTINUED) Concrete Ring Installation (Fig. 3) 1. Apply interior finishing material. 2. Position the Concrete Ring with the semi-circle tab located at the top and then press the ring into finishing material. 3. Trowel the finishing material around outside and inside of the Concrete Ring. 4. Form a watertight seal around the suction pipe. 5. Wipe clean any finishing material that remains on the Concrete Ring's top edge and mounting surface. Concrete Cover Assembly (Fig. 4) 1. Align the Concrete Support with the alignment tab located on the Concrete Ring. 2. Install three (3) machine screws through the Concrete Support. Secure the screws without over tightening. 3. Align the Cover with the Support holes. 4. Install three (3) security screws through the cover. Secure the screws without over tightening. Fig. 3 3 Min (typ) Fig. 4 8

STEEL & CONCRETE INSTRUCTIONS Keep rebar 3" away from MDX² sump. 1. To allow the sump to be fully encased in concrete, clear dirt to completely expose the sweep elbow. (Fig. 5) 2. Pack concrete around and under sump (Fig. 5) to ensure seal and strength of shell 3. Angle shell down to MDX² sump. (Fig. 5) (Flatten area around Sump 24X24). 4. Make cut-out around MDX² sump. 24 round by 1¼ deep. (Fig. 6 & 8) 3 3 MDX Debris Removal System STANDARD POOL/SPA/BASIN DESIGN Steel Cage INTERIOR FINISH RING 3 7 8 3 1/4 Plaster Ring Installation: Set the plaster ring at final finish. 1. Align the Plaster Ring Keyway with the Sump Alignment Key. (Fig. 7) Note: Sump alignment key can be removed if desired allowing 360 of paster ring alignment. 2. Adjust the elevation and the angle of the Plaster Ring to align it with the finished interior surface of the pool, spa, or basin. 3. Press into finish material and trowel surface flush with to edge of plaster ring. 6 1/8 6 TOP OF PIPE 12 6 10 1/8 12 Assemble the drain PRIOR TO ADDING WATER (see illustration on page 10 for reference): 1. Install upper support (#5) onto plaster ring (#4) and secure with 8 (eight) security screws (#6) with screw driver security T25 (#20). 2. Install the cover (#7) onto the upper support (#5) and secure with 6 (six) phillips screws (#8) and 2 (two) phillips screws (#). Fig. 5 Fig. 7 24 FLAT ALL AROUND CONCRETE SHELL FUTURE INTERIOR FINISH CONCRETE SHELL FUTURE INTERIOR FINISH EARTH EARTH Fig. 6 CONCRETE SHELL 1.2 CUTOUT DEPTH TO BOTTOM OF FLANGE 24 Ø CUTOUT FUTURE INTERIOR FINISH Fig. 8 Ø 24 CUTOUT EARTH

MDX² WINTERIZATION WITH CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2. 1. Remove grate from wall drain and install a 13-¾ blow through plug and blow line to achieve airlock. 2. If 3rd suction line is installed remove grate, install a 13-¾ blow-through plug and blow line to achieve airlock. 3. Go to canister instructions step 1-4 below. 4. If vent tube is installed, install blow through plug and blow line to achieve airlock. Repeat vacuum out canister. Then complete canister step 5. WITHOUT CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2. 1. Remove grate from wall drain and install a 13-¾ blow through plug and blow line to achieve airlock. 2. If 3rd suction line is installed remove grate, install a 13-¾ blow-through plug and blow line to achieve airlock. 3. If vent line is installed in main suction line, plug vent line and install blow through plug in pump inlet and blow line to achieve airlock. 4. Lastly, blow vent line to achieve airlock. PARAMOUNT CANISTER WINTERIZATION 1. Remove outer lid, inner lid and basket, clean and dry off, and store in same area as modules 2. Install and secure regular winterization plug in equalizer line of canister to pool at poolside. 3. Install and secure Schrader plug or blow out plug from canister to main drain. Blow out and obtain air lock as previously described, if skimmer is tied into canister, repeat procedure to skimmer. 4. Bottom port of canister to pump may require an extended pipe for ease of blowing out. Install and blow out line from canister to pump. Install and secure plug in pump. Using shop vac, remove all water from within canister components. 5. Extension pipe can be removed and replaced with plug or Gizmo type container if Gizmo not used. Be sure to install device to absorb ice expansion in canister area. Failure to do this may result in potential ice freeze damage to canister. TEST PLUGS GALV. SQ. HEAD TO MAIN DRAIN Fig. BALANCE LINE TO OPTIONAL SKIMMER OR VENT LINE USE STANDARD SKIMMER PLUG WRENCH Winterization anti-freeze is to be used as necessary or when required. Additional questions should be forwarded to Paramount's corporate office at 1.800.621.5886. VENT TUBE WARNING LABELS Included in each MDX² are two warning labels that need to be placed on the pool equipment if the pool is to be winterized and has a vent tube on any of the drains plumbed on the pool. Attach the smaller label to the vent pipe where it terminates to atmosphere. (See Fig. ) Fig. 10 Attach the larger label to the control panel next to the controller for the pump with the vent tube plumbed to it. (See Fig. 10) 10

004-202-2210-XX MDX² CONCRETE W/O CONSTRUCTION CAP Replace within 05 installed years 11 Available Construction Caps 10 11 20 11 7 2 8 10 10 2 6 20 20 5 4 2 14 3 15 13 1116 14 14 14 1 17 18 10 R1 20 1 2 Item Part Number Description *R1 N/A 1 005-202-2013-00 2 005-252-1611-00 Plug Pressure Test 2½ w/ O-Ring (4 pk) 3 005-252-1605-00 Plug 2 (6 pk) 4 005-252-2208-00 Plaster Ring 5 005-202-2206-00 Upper Support 6 005-252-081-00 Screw: No. 10X3/4 Security Head (12 pk) 7 005-252-2204-XX Cover 8 005-252-082-00 Screw: No. 8X3/4 Security Head (12pk) 005-252-0872-00 Screw: No. 8X3/8 Security Head (12pk) *10 005-202-1155-00 Plaster Cap *11 005-202-1148-00 Sump Construction Cap 13 006-202-6180-00 Sump Adaptor Kit Required to Reduce Pipe Size 14 004-162-2212-XX High Flow Safety Drain (2pk) (XX = Color Code) 15 005-252-0828-00 Screw: 10X7/8 TORX W/PIN SS B (12 pcs) 16 005-252-2084-XX Cover w/ Screws 17 005-252-0864-00 Screw: 10-32 x 1/2 PHIL FLT HD machine 316SS (12 pcs) 18 005-252-2066-00 Support Concrete 1 005-252-2050-00 Ring Concrete) 20* 005-252-085-00 T25 Security Screwdriver * 004-252-5476-00 Plug Wrench 14 Cap not used. Sump MDX Concrete - 2½" * Not part of MDX² WARNING: MDX² and must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. 11