GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

Similar documents
Forehead Thermometer Instruction manual

Dual-Mode Infrared Thermometer Instruction Manual

Forehead Thermometer Instruction Manual

CLETEF-786. Infrared Thermometer Instruction Manual

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

NON-TOUCH THERMOMETER User Manual

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

No Touch Thermometer

Instructions. Consumer Info-Line

Forehead Infrared Thermometer

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

High Temperature InfraRed Thermometer with Laser Pointer

Kinsa Smart Ear ThermometerTM Instructions For Use

THERMOFOCUS 0800H5 Professional

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

Dual Laser InfraRed (IR) Thermometer

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

The design of the human body infrared thermometer

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

for a healthy world Product catalogue 2010/ 2011

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Dual Laser InfraRed (IR) Thermometer

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

THERMOFOCUS 01500A3 THERMOFOCUS

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

I/R Thermometer Gun 12:1

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

CareTemp Touch Free Thermometer. Directions for use

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

USER MANUAL Digital CO Monitor Model CO30

Manual PCE-889 pyrometer

HV2R ROTARY LASER INSTRUCTION MANUAL

IRT2 Dual Laser IR Thermometer - User Guide

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Product catalogue

Refrigerator/Freezer Thermometer

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

WIRELESS FRIDGE THERMOMETER Instruction Manual

Refrigerator/Freezer Thermometer

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

EST User Manual. (Please read this manual carefully before using)

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

T5000 LCD Digital Fan Coil Thermostat

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION


Oxygen Monitor Operating Manual

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections:

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

T-32-TS Touchscreen Thermostat. Installation Manual

High Resolution Display WIRELESS COLOR WEATHER STATION

RS Pro Infrared Temperature Sensor

Precision Infrared Thermometer. Users Manual

CO2 Monitor Operating Instructions

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

USER GUIDE Heat Index Psychrometer

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Commodity Description

WIRELESS COLOR WEATHER STATION

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Analog Room Pressure Monitor RPC Series

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

WBGT Heat Stress Meter

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

HIn3550 Magnetic Field Monitor User's Manual

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

KM300 Carbon Monoxide Detection System Installation Manual

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

CLEO VERSATILITY IN VITAL SIGNS

Wet Bulb Thermo-Hygrometer Datalogger

Indoor/Outdoor Temperature Alert

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

AlcoBlow. User Handbook

Chapter 5 Inspection and maintenance

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Chapter 5 Inspection and maintenance

DP 300 mobile dew point instrument

Ambient Weather WS-25 Wireless 8-Channel Floating Pool and Spa Thermometer with Indoor Temperature and Humidity User Manual

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Transcription:

GHC-1001 0482 Thermee Non-Contact Forehead Thermometer Instruction manual V2.5 1

Introduction Thank you for choosing the NON-contact Digital Infrared Forehead Thermometer from Ginger Hill Creations, Forehead Thermometer for short in these instructions With this unique technology, the forehead thermometer can give you accurate results with non-contact, stable measurement and without the interference from ambient temperature. The product will self-test every time it starts up to make sure of normal operation and accuracy. The forehead thermometer can be used to measure body temperature, which is suitable for people of all ages. It can be used to measure the temperature of milk and many other items as well. In our examples we will use milk but feel free to adapt it as needed. Please read the instructions carefully before using the product, and put it in a safe and secure place for reference. 2

Contents Cover Page..1 Introduction.....2 Contents...3 1.The advantages of our Forehead Thermometer GHC-1001...4 2.Necessary safety instructions...4 3.Instructions for product designs...5 4.How to measure with the forehead temperature...6 5.How to measure the milk temperature...6 6.Instructions for display and operation...6 7.Technical specifications...9 8.After-sale service... 11 9.Security type... 11 10.Correspondence:... 11 11. Additional Use and Care....11 3

1.The advantages of a Forehead Thermometer Multiple uses (measurement of body temperature and milk temperature) Forehead Thermometer provides measurement of body temperature, which is from 32 to 42.2 (from 89.6 to 107.9 ), and milk temperature, which is from 0 to 100.0 (from 32.0 to 212.0 ). The product consists of ABS common plastics, TPR plastics, temperature sensor, Infrared temperature measuring element, microcomputer controlled circuit and LCD. Convenient of use Special ergonomic design for easy use No interference for your normal life. Ability to take measurements during your children s sleep Comfortable compared with rectal thermometers for children, and more rapid and simple compared with mouth thermometers and more flexible compared with contact forehead thermometer. Read multiple groups of memory data The user can read 20 groups of memory data by choosing memory mode, which is effective for tracing the change of temperature over time. Safe and hygienic No-contact measurement won t bring about the accumulation of bacteria, and it doesn t need to be cleaned very often. There is no danger of breaking the glass or swallowing mercury It is totally safe for children to use. Fever warning When the readings exceed 37.5 /99.5, the product shall warn patients that he/she may have a fever by 7 rapid, short rings and red backlight.(for normal body temperature, the signal is long ring and green backlight) Extensive clinical data of hospital use has been tested. In cooperation with partner hospitals the unit has been subjected to precise clinical verification, with the support of extensive clinical data and professional medical experts. 2.Necessary safety instructions Operating Conditions: Temperature: 10 C to 40 C Humidity: <80% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa Storage and Shipping Conditions: Temperature: -10 C to 60 C 4

Humidity: 0-95% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa The device is not normally used for a newborn baby. The device is not a continuous monitoring device. The device is not waterproof. Please do not wet it with water or with other liquids. Cleaning and disinfection procedure must be in compliance with the instructions specified in [cleaning and storage] Please do not use the product if the temperature sensor or the forehead thermometer shows any sign of damage. Do not try to repair the product if it is damaged. Please contact our Customer Service or Warranty Department. The device consists of precision parts of the highest quality. Please prevent the product from falling. Please prevent any intense shock or vibration. Do not twist the forehead thermometer and the temperature sensor. Battery Installation: 1. Put the two AAA batteries into battery compartment in correct polarities. 2. Push the battery cover horizontally along the arrow. Notes: If this is your first time using the thermometer, please pull out the Plastic battery protector sheet. Battery polarities should be correctly installed. Otherwise, damage may be caused to the device. Please put in or remove batteries in the correct order, or you may cause damage to the device bracket. Please remove the batteries if the thermometer will not be used for a long time. Warnings Please keep the forehead thermometer out of your children s reach Medical assistance can t be replaced by the use of infrared forehead thermometer The forehead thermometer is not waterproof! Do not put it into any liquid. 3.Instructions for product designs (1)Temperature sensor (2) Press button for measuring body temperature (3) Press button for measuring milk temperature 5

(4) LCD display screen (5) Battery cover 4.How to measure with the forehead temperature The device measures the infrared energy emitted from the forehead, which will focus through the lens and convert it to a temperature value by the thermopile and measuring circuit. It is recommended that you press button (2) and scan the forehead from one side to another at a distance from ½ to 2, then release the button with the maximum value displayed. Fixed point measurement may result in an inaccurate diagnosis. 5.How to measure the milk temperature The device measures the infrared energy emitted from a feeding bottle, and it will display the milk temperature by transition calculation and emission rate compensation. Please use the press button (3) for startup when measuring. In order to avoid any inaccuracy: Please make sure that there is no dirt in on the temperature sensor Please make sure that there is no intense emotion and movement before measuring. There should be no water on the forehead. If the device is transferred from one area to another which has different ambient temperature, it is suggested to allow it acclimate for more about 30 minutes. Do not hold the device for long time as it is highly sensitive to heat. the device has undergone clinical testing, it is safe and accurate when used in accordance with the operation manual. 6.Instructions for display and operation Operational method and instruction LCD display Sound and backlit for displays 1.Measurement of body Forehead temperature temperature mode 1.Aim the temperature sensor (1) at 1.When temperature the measurer s forehead directly value is (effective distance from ½ to 2 ) between32.0 /89.6 under shutdown state, and press and 37.6 /99.6,there 6

button (2) or hold down button (2), it shall be one long ring shall display measured value when and green backlit for 3 releasing button, which is under seconds. forehead temperature mode. 2.When temperature Holding down the button and value is scanning over the forehead are between37.6 /99.6 to suggested. The system will read 42.2 /107.9, there sequentially and record the shall be 7 short ticks maximum and red backlit for 3 2.Measurement of milk temperature seconds Press button (3) within 4 seconds Milk temperature mode and release it under shutdown state. 1.When the It shall display measured value, temperature value is which is under milk temperature between 0.0 /32.0 to mode. 100.0 /212.0, there 3.Press button (2) or (3) under shall be a long tick and startup mode and enter green backlit for 3 measurement mode again. seconds. Attention: There shall be 7 short rapid ticks when the measured temperature exceed 37.5 /99.5, which is a warning for patients that he/she may have a fever or There shall be signal for relative mode under measurement preparedness. The or signal shall twinkle. If the measurer presses button(2) or (3) again, the measurement mode is available. 1.The measured value exceeds 100 /212.0 under milk temperature mode. 2.The measured value exceeds 42.2 /107.9 Under forehead temperature mode. 3 short tick and red backlit for 3seconds. 7

1. The measured value exceeds 0 /32.0 under milk temperature mode. 2. The measured value exceeds 32 /89.6 Under forehead temperature mode. Inquiry for memory data, Storing 20 groups of data Operational method and instruction for LCD display displays 3 short tick and red backlit for 3seconds. Sound and backlit Click button (3) for 4-8seconds and LCD displays - - - with M signal twinkling. silence Click button (3) again and the LCD displays the first data group with M signal twinkling. Click button (3) and it shall display the serial number for 1 second and then display the measured data. There are 20 groups of data. Mark:The memory is forehead data only. silence C/F conversion The LCD shall only display - - -, / and M signal with M signal twinkling if there is no test silence data. LCD Operational steps display Press button (3) for 8-12seconds under shutdown state, and the temperature unit shifts automatically. Press button (3) within 5 seconds after release, and the temperature unit shifts again unless the release time exceeds 5 second. The products shall be automatic startup and enter into the milk temperature mode. Error message It shall display Er1 when ambient temperature exceeds 40.0 /104 or drop below 10.0 /50.0. Sound and backlit silence 3 short tick and red backlit for 3seconds. 8

Power Off Mode It shall display ErC if there is EEPROM data reading error or the correcting process is not finished.please contact your supplier. There shall be low-voltage signal(no twinkling) when the battery voltage is below2.61v±2%.please replace the battery. 3 short tick and red backlit for 3seconds. silence In any mode,if no operation for 10 seconds,it will power off automatically. Attention: Electromagnetic interference: the device contains sensitive electronic component and shall not use under the condition with electromagnetic interference,( such as the place nearby the mobile phones and microwaves ) Please dispose the used products and batteries in accordance with local regulation requirements when the products and batteries are not available. Please take out the battery if the device unused for long time. 7.Technical specifications Items Standards models 1.Applicable regulations and laws 2.Temperature units 3.Measurement range 4.Precision 5.Display resolution 6.Latency Time Forehead thermometer the device ASTM 1965 GB/T 19146-2010 /, adjustable Forehead temperature mode:32.0-42.2 / 89.6 F 107.9 F Milk temperature mode:0.0-100.0 /32.0 F 212.0 F ±0.2 /±0.4 F 0.1 /0.1 1 second 9

7.Abnormal state display 8.Sound and backlit 9.Automatic shutdown function 10.Low-voltage display function 11.Memory function 12.Current consumption 13.LED backlit specifications 15.Operational conditions 16.Type of measuing 17.battery 18.Battery life LCD displays L if the measured temperature is below the minimum of measurement range. LCD displays H if the measured temperature is below the minimum of measurement range. LCD displays Er1 if the temperature measurement circuit is abnormal (fault of SENSOR or the temperature measurement circuit), or the ambient temperature exceed 10 ~40 (50-104 ). There shall be ErC if the calibration process is not completed or EEPROM is abnormal. volume 50 db (the perpendicular distance from db Volume sensor to thermometer is 10cm ) Two kinds of backlist: red and green Forehead temperature mode: 1.There shall be one long beep and green backlit for 3seconds when the temperature is between 32.0 /89.6 to 37.6 /99.6. 2.There shall be seven short beeps and red backlit for 3 seconds when the temperature is between 37.6 /99.6 to 42.2 /107.9. Milk temperature mode: 1. There shall be one long beep and green backlit for 3seconds when the temperature is between 0.0 /32.0 to 100.0 /212.0. 10s±1s The product shall display low-voltage signal if the voltage is below 2.61V±0.15V. Memorize 20 groups of measured temperature. Istand-by<2μA; Iworking<0.5mA; IBuzzer on<2ma;ibanklight<15ma Red 1.2cd/m 2 Green 2.0cd/m 2 ASTM 10-40 (50-104 )/15-95%RH Applicable for forehead temperature and milk temperature Changeable for two 1.5V triple A batteries More than 1000 times 10

19.Accuracy for clinical test The maximum allowable error for clinical test is specified in the formula below: Terror = T1-Tref 0.3 /0.6 (for 95%) Among which: T1 and T2 represent temperature value for thermometer under test respectively, Tref represents the constant reference temperature It is recommended that professional users and clinics conduct a technical inspection once every two years in accordance with the Medical Products User Law 8.Warranty Service The device is under warranty for two years after the date of purchase. Application for repairing should be presented during the warranty period. Any damage caused by improper use is not under the scope of the warranty. Batteries and packaging are not under warranty scope as well. Please return the unit to: Ginger Hill Creations, 16238 Highway 620 N., Suite F-104, Austin TX 78717 for repair or replacement. 9.Security type The signal indicates that the thermometer is a BF type device with internal power supply. + 2 T2-Tref 10. Correspondence Ginger Hill Creations 16238 Highway 620 N. Suite F-104 Austin, TX 78717 11. Additional Use & Care Videos, Coupons, books and Special Features: Visit: www.gingerhillcreations.com 11

Visit Us! www.gingerhillcreations.com for Coupons VIP Reviewers Club Signup Videos Guides Parenting Reports 12