Forehead Thermometer Instruction manual

Similar documents
GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

Dual-Mode Infrared Thermometer Instruction Manual

CLETEF-786. Infrared Thermometer Instruction Manual

Forehead Thermometer Instruction Manual

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

No Touch Thermometer

Instructions. Consumer Info-Line

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Forehead Infrared Thermometer

NON-TOUCH THERMOMETER User Manual

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

Kinsa Smart Ear ThermometerTM Instructions For Use

The design of the human body infrared thermometer

CareTemp Touch Free Thermometer. Directions for use

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

High Temperature InfraRed Thermometer with Laser Pointer

THERMOFOCUS 0800H5 Professional

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

I/R Thermometer Gun 12:1

Dual Laser InfraRed (IR) Thermometer

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

for a healthy world Product catalogue 2010/ 2011

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

WIRELESS FRIDGE THERMOMETER Instruction Manual


Dual Laser InfraRed (IR) Thermometer

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

EST User Manual. (Please read this manual carefully before using)

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

THERMOFOCUS 01500A3 THERMOFOCUS

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Oxygen Monitor Operating Manual

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Concrete and Mortar Moisture Tester Model HI-520. Operating Manual

WBGT Heat Stress Meter

Precision Infrared Thermometer. Users Manual

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

KM300 Carbon Monoxide Detection System Installation Manual

CO2 Monitor Operating Instructions

KANE-ALERT-CO 2 Monitor with Temperature

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Manual PCE-889 pyrometer

HV2R ROTARY LASER INSTRUCTION MANUAL

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

Buzzer Unit. TAN-5000 Series. Operating Manual

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Product catalogue

T5000 LCD Digital Fan Coil Thermostat

Security GSM Alarm System

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

HIn3550 Magnetic Field Monitor User's Manual

Room Temperature Sensor

PDA20DX Air Purifying Dehumdifier Manual

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Laser Distance Sensor Type M Analog-Output

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

RS Pro Infrared Temperature Sensor

Commodity Description

IRT2 Dual Laser IR Thermometer - User Guide

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Refrigerator/Freezer Thermometer

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

Design Manual Installation Operation Maintenance

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

TM-802 Formaldehyde Meter User s Manual

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

TrueAlarm Analog Sensing

USER MANUAL Digital CO Monitor Model CO30

Refrigerator/Freezer Thermometer

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections:

This instruction manual explains the use of three models listed on the left.

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Digital Wall Clock LED. Model Number: MWC01 READ AND SAVE THESE INSTRUCTIONS

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

2-Channel Smoke Detector SD - 110

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Transcription:

048 Forehead Thermometer Instruction manual 9 1

Introduction Thank you for choosing the NON-contact Digital Infrared Forehead Thermometer, Forehead Thermometer for short. With the unique technology, the forehead thermometer can give the result with non-contact, stable measurement and without the interference from ambient temperature. The product will self-test every time it starts up to make sure the normal operation and accuracy. The forehead thermometer can be used to measure the body temperature, which is suitable for people of all ages. It can be used to measure the temperature of milk as well. 19.Accuracy for clinical test The maximum allowable error for clinical test is specified in the formula below: Terror = T1-Tref 0.3 /0.6 (for 95%) Among which: T1 and T represent temperature value for thermometer under test respectively, Tref represents the constant reference temperature It is recommended that the professional users apply technical inspection once every two years in accordance with Medical Products User Law 8.After-sale service The device is under warranty for two years since the date of acquisition. Application for repairing should be presented during the warranty period. The damage caused by improper use is not under warranty scope. Batteries and packaging are not under warranty scope as well. 9.Security type The signal indicates that the thermometer is a BF type device with internal power supply. + T-Tref Please read the instructions carefully before using the product, and put it in a safe and secure place for reference. 10.Authorized European Representative: Wellkang Ltd Suite B, 9Harley Street, LONDON, W1G9QR,U.K. 8

7.Abnormal state 8.Sound and backlit 9.Automatic shutdown function 10.Low-voltage function 11.Memory function 1.Current consumption 13.LED backlit specifications 15.Operational conditions 16.Type of measuing 17.battery 18.Battery life LCD s L if the measured temperature is below the minimum of measurement range. LCD s H if the measured temperature is below the minimum of measurement range. LCD s Er1 if the temperature measurement circuit is abnormal (fault of SENSOR or the temperature measurement circuit), or the ambient temperature exceed 10 ~40 (50-104 ). There shall be ErC if the calibration process is not completed or EEPROM is abnormal. volume 50 db (the perpendicular distance from db Volume sensor to thermometer is 10cm ) Two kinds of backlist: red and green Forehead temperature mode: 1.There shall be one long beep and green backlit for 3seconds when the temperature is between 3.0 /89.6 to 37.6 /99.6..There shall be seven short beeps and red backlit for 3 seconds when the temperature is between 37.6 /99.6 to 4. /107.9. Milk temperature mode: 1. There shall be one long beep and green backlit for 3seconds when the temperature is between 0.0 /3.0 to 100.0 /1.0. 10s±1s The product shall low-voltage signal if the voltage is below.61v±0.15v. Memorize 0 groups of measured temperature. I stand-by <μa; I working <0.5mA; I Buzzer on <ma;i banklight <15mA Red 1.cd/m Green.0cd/m ASTM 10-40 (50-104 )/15-95%RH Applicable for forehead temperature and milk temperature Changeable for two 1.5V triple A batteries More than 1000 times Contents 1.The advantages of Forehead Thermometer the device...1.necessary safety instructions...1 3.Instructions for product designs... 4.How to measure the forehead temperature...3 5.How to measure the milk temperature...3 6.Instructions for and operation...3 7.Technical specifications...6 8.After-sale service...8 9.Security type...8 10.Authorized European Representative:...8 7 3

1.The advantages of Forehead Thermometer Multiple use(measurement of body temperature and milk temperature) Forehead Thermometer provides measurement of body temperature, which is from 3 to 4. (from 89.6 to 107.9 ), and milk temperature, which is from 0 to 100.0 (from 3.0 to 1.0 ). The product consists of ABS common plastics, TPR plastics, temperature sensor, Infrared temperature measuring element, microcomputer controlled circuit and LCD. Convenient for use Special ergonomic design for easy use No interference for your normal life. Available for measurements during children s sleep Comfortable compared with anus thermometers for children, and more rapid and simple compared with mouth thermometers and more flexible compared with contact forehead thermometer. Read multiple group of memory data The user can read 0 groups of memory data by choosing memory mode, which is effective for tracing the change of temperature. Safe and hygienic No-contact measurement won t bring about the accumulation of bacteria, and it doesn t need to be clean on purpose practically. There is no danger of breaking the glass or swallowing the hydrargyrum It is totally safe for children to use. Fever warning When the readings exceed 37.5 /99.5, the product shall warn patients that he/she may have a fever by 7 rapid, short rings and red backlit.(for normal body temperature, the signal are long ring and green backlit) Extensive clinical data of hospital The cooperation with designated hospitals is subjected to precise clinical verification, with the support of extensive clinical data and professional medical experts..necessary safety instructions Operating Conditions: Temperature: 10 C to 40 C Humidity: <80% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa Storage and Shipping Conditions: Temperature: -10 C to 60 C Humidity: 0-95% RH, non-condensing Power Off Mode It shall ErC if there is EEPROM data reading error or the correcting process is not finished.please contact your supplier. There shall be low-voltage signal(no twinkling) when the battery voltage is below.61v±%.please replace the battery. 3 short tick and red backlit for 3seconds. In any mode,if no operation for 10 seconds,it will power off automatically. Attention: Electromagnetic interference: the device contains sensitive electronic component and shall not use under the condition with electromagnetic interference,( such as the place nearby the mobile phones and microwaves ) Please dispose the used products and batteries in accordance with local regulation requirements when the products and batteries are not available. Please take out the battery if the device unused for long time. 7.Technical specifications Items models 1.Applicable regulations and laws.temperature units Standards Forehead thermometer the device ASTM 1965 GB/T 19146-010 /, adjustable Forehead temperature mode:3.0-4. / 89.6 F 3.Measurement 107.9 F range Milk temperature mode:0.0-100.0 /3.0 F 1.0 F 4.Precision ±0. /±0.4 F 5.Display resolution 6.Latency Time 0.1 /0.1 1 second 1 6

1. The measured value exceeds 0 /3.0 under milk temperature mode.. The measured value exceeds 3 short tick and red backlit for 3seconds. 3 /89.6 Under forehead temperature mode. Inquiry for memory data, Storing 0 groups of data LCD Operational method and instruction for s Sound and backlit C/F conversion Click button (3) for 4-8seconds and LCD s - - - with M signal twinkling. Click button (3) again and the LCD s the first data group with M signal twinkling. Click button (3) and it shall the serial number for 1 second and then the measured data. There are 0 groups of data. Mark:The memory is forehead data only. The LCD shall only - - -, / and M signal with M signal twinkling if there is no test data. LCD Operational steps Press button (3) for 8-1seconds under shutdown state, and the temperature unit shifts automatically. Press button (3) within 5 seconds after release, and the temperature unit shifts again unless the release time exceeds 5 second. The products shall be automatic startup and enter into the milk temperature mode. Error message It shall Er1 when ambient temperature exceeds 40.0 /104 or drop below 10.0 /50.0. Sound and backlit 3 short tick and red backlit for 3seconds. Atmospheric pressure: 860hPa to 1060hPa The device is not used for newborn baby. The device is not continuous monitoring device. the device is not waterproof. Please do not douse it into the water or other liquids. Cleaning and disinfection procedure shall be in comply with the instructions specified in [cleaning and storage] Please do not use the product if the temperature sensor or the forehead thermometer shows any sign of damage. Do not try to repair the product if it is damaged. Please contact the nearest Customer Service. the device consists of precision parts with high quality. Please prevent the product from falling off. Protection shall be provided for no intense shock and vibration. Do not twist the forehead thermometer and the temperature sensor. Battery Installation: 1. Put the two AAA batteries into battery compartment in correct polarities.. Push the battery cover horizontally along the arrow. Notes: If you are the first time using the thermometer, please pull out the Plastic sheet. Battery polarities should be correctly installed. Otherwise, damage may be caused to the device. Please put in or remove batteries in right order, or may cause damage to the device bracket. Please remove the batteries if the thermometer will not be used for a long time. Warnings Please put the forehead thermometer out of children s reach Medical assistance can t be replaced by the use of infrared forehead thermometer The forehead thermometer is not waterproof! Do not douse into liquid. 3.Instructions for product designs (1)Temperature sensor () Press button for measuring body temperature (3) Press button for measuring milk temperature 5

(4) LCD screen (5) Battery cover 4.How to measure the forehead temperature the device measures the infrared energy emitted from forehead, which will focus through lens and convert to temperature value by thermopile and measuring circuit. It is recommended that you press button () and scan the forehead from one side to another at a distance from 1cm to 6cm, then release the button with the maximum value ed. Fixed point measurement may result in error diagnosis. 5.How to measure the milk temperature the device measures the infrared energy emitted from feeding bottle, and it shall the milk temperature by transition calculation and emission rate compensation. Please use the press button (3) for startup when measuring. In order to avoid the inaccuracy: Please make sure that there is no dirt in on the temperature sensor Please make sure that there is no intense emotion and movement before measuring. There shall be no water on the forehead. If the device is transferred from one condition to another which has different ambient temperature, it is suggested to deposit for more than 30minutes. Do not hold the device for long time as it is highly sensitive to heat. the device has undergone clinical test, it is safe and accurate when using in accordance with operation manual. 6.Instructions for and operation LCD Operational method and instruction for s 1.Measurement of body temperature 1.Aim the temperature sensor (1) at the measurer s forehead directly (effective distance from 1 to 6 cm) under shutdown state, and press button () or hold down button (), it shall measured value when Sound and backlit Forehead temperature mode 1.When temperature value is between3.0 /89.6 and 37.6 /99.6,there shall be one long ring and green backlit for or releasing button, which is under forehead temperature mode. Holding down the button and scanning over the forehead are suggested. The system will read sequentially and record the maximum.measurement of milk temperature Press button (3) within 4 seconds and release it under shutdown state. It shall measured value, which is under milk temperature mode. 3.Press button () or (3) under startup mode and enter measurement mode again. Attention: There shall be 7 short rapid ticks when the measured temperature exceed 37.5 /99.5, which is a warning for patients that he/she may have a fever There shall be signal for relative mode under measurement preparedness. The or signal shall twinkle. If the measurer presses button() or (3) again, the measurement mode is available. 1.The measured value exceeds 100 /1.0 under milk temperature mode..the measured value exceeds 4. /107.9 Under forehead temperature mode. 3second..When temperature value is between37.6 /99.6 to 4. /107.9, there shall be 7 short ticks and red backlit for 3seconds Milk temperature mode 1.When the temperature value is between 0.0 /3.0 to 100.0 /1.0, there shall be a long tick and green backlit for 3senconds. 3 short tick and red backlit for 3seconds. 3 4