Venmar Ventilation inc. is North America s most important manufacturer of residential air quality equipment.

Similar documents
big building site We have the product for you 1 Ventilateur Optimum

SA-20WB-HPE SA-20WB-LPE SA-20WT-HPE SA-20WT-LPE SA-30WT-HPE SA-30WT-LPE SA-20WB-HP SA-20WB-LP SA-20WT-HP SA-20WT-LP SA-30WT-HP SA-30WT-LP

Ventis Direct Vent. Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

The best way to enhance indoor air quality

Builder s Technical Sessions. Attic Ventilation. Presented by: Rob Kaethler. Presented in Partnership with: Insert your logo here

Siding Installation Guide

V ENTILATION V IEWS. News, opinions, ideas and technical advice from the ventilation specialists at Air Vent

AirScape Solar Attic Fan. Installation Manual SAF10R SAF25R

CMHC HOME MAINTENANCE CHECKLIST

GUIDE TO GOOD VENTILATION

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

INSTALLATION AND SERVICE MANUAL

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Home Maintenance Schedule

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

Do not use this vent pipe or fittings for venting incinerators of any kind.

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

about your house Attic Venting, Attic Moisture, and Ice Dams Figure 1 Typical attic floor insulations

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Installation Guide Maibec Regular Siding

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Innovative designs for the construction industry

Pellet Vent INSTALLATION INSTRUCTIONS

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

HEAT RECOVERY VENTILATOR

Pellet Vent INSTALLATION INSTRUCTIONS

Maintence/Renewal Report

Vent Supplement Ultra-80, -105, -155, -230 & -310

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

Good News at Home Hankey & Brown Inspection Service June 2013

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

READ AND SAVE THESE INSTRUCTIONS

MODEL CF CEILING SUPPORTED CHIMNEY

PA 500/1100V Ultra Quiet Ventilation Fan

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Attic Condensation. Presented by: Joan Maisonneuve Technical Services

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

INSTALLATION AND SERVICE MANUAL

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

DuraTech. Installation Instructions. Combustion Air System

VJ504302SS CHIMNEY RANGE HOOD

CHIMNEY RANGE HOODS MODELS VJ51030SS AND VJ51036SS

READ AND SAVE THESE INSTRUCTIONS

Chapter FUEL GAS CODE*

The Ultimate Home Maintenance Schedule

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Axial fans The right fan for every house

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

OFF-RIDGE VENTILATION PRODUCT BROCHURE

Inspection Checklist Mechanical Rough in

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM

APPUZO RANGE HOOD INSTALLATION

Unvented Roof Assemblies for All Climates by Chris Schumacher

Indoor Air Quality Product Brochure.

Innovative designs for the construction industry.

Heat Recovery Ventilators models:

Innovative designs for the construction industry.

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

PLEASE READ AND SAVE THESE INSTRUCTIONS

Gardian W51. Approvals

ASX7-5-IOM-3 J

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

EUTECTIC EC-10DV Series

This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

BDM Direct Vent systems are for use with direct vent gas fired appliances.

Installation and Operating Instructions

Home Set-up and Maintenance. Maintenance

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

ASX7-4-IOM-6 J

CARE & INSTRUCTION MANUAL

DELUXE ELECTRIC POWER BRUSH

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

CHIMNEY RANGE HOODS MODELS VJ603302SS & VJ604302SS

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

INSTALLATION INSTRUCTIONS

HVAC Equipment Access Equipment Location

Practical and Effective Approaches to Residential Ventilation for Production Builders

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: RHC60IX, RHC90IX. All dimensions in mm Model may vary slightly from images pictured

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions

Ventilation Standards

Principles of Attic Ventilation. Acomprehensive guide toplanning The BalancedSystem for attic ventilation

HotFlashing. HotFlashing TM

Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

Transcription:

Venmar sets the standard for the ventilation industry! Venmar Ventilation inc. is North America s most important manufacturer of residential air quality equipment. With over twenty-five years of innovation, Venmar Ventilation has been recognized as leader in the field with its leading-edge technology and breakthrough ideas. From basement to attic, kitchen to bathroom, Venmar s wide range of high quality products has been developed to meet your every ventilation need. You have ventilation problems? Venmar has the solution! Venmar attic ventilators give you the following advantages Better corrosion resistance through the use of 24 and 26-gauge G90 galvanized steel and baked enamel polyester paint; Innovative design to prevent rain and snow infiltration; Easy installation thanks to its multi-slope base; Exclusive gutter to evacuate condensation and prevent roof material degradation; Fine mesh grill (1/4 x 1/4 ) to prevent blockage of the ventilator.

Table of contents General information Why install an attic ventilator? 4 How to evaluate an attic ventilator s capacity? 4 National Building Code requirements 5 Number of ventilators needed for each roof configuration 6 Basic rules 8 Venmar attic ventilators 9 Recommendations for each type of installation Soffits obstructed by insulation 11 Closed-in soffits 11 Warm or humid air source 12 Gable roof 12 Mansard roof 13 One-sided cathedral ceiling 13 Asymmetrical roof (without cathedral ceiling) 14 Cathedral ceiling with one slope 14 Installation steps Attic ventilator components 15 Required tools and materials 15 Existing roof 16 New roof 17 Flat roof 18 Table of contents 3

Why install an attic ventilator? Installing an attic ventilator prevents : 1 Accumulation of ice on the roof; 2 Frost in the attic; 3 Water infiltration that can damage your ceiling; 4 Accelerated degradation of materials. Moreover, the National Building Code requires adequate attic ventilation. How to evaluate an attic ventilator s capacity? 4 According to both CSA standard CAN-3-A93-M82 (National Building Code) and the Home Ventilation Institute (HVI) certification, the ventilation capacity of attic ventilators in based on net ventilation area. Refer to the table on page 9.

National Building Code requirements 1 Use square footage to determine required ventilation 2/12 slope or more = 1 ft 2 ventilation opening for 300 ft 2 of insulated ceiling surface (1/300). Slope less than 2/12 = 1 ft 2 ventilation opening for 150 ft 2 of insulated ceiling surface (1/150). (fig. 5.1) Exemple : A 40 ft x 30 ft house (with a slope greater than 2/12) A (fig. 5.2) A = 40 ft B = 30 ft B (fig. 5.3) 40 ft x 30 ft = 1, 200 ft 2 300 = 4 ft 2 of ventilation 2 Distribution of ventilation square footage The National Building Code requires that 25 % of the 1/300 must be allocated to each of the upper and lower space of the attic. When used in conjunction with the soffits, the attic ventilator creates an updraft (chimney) effect to adequately ventilate the attic. For this example: One sq.ft. (minimum) in the upper part of the attic. One sq.ft. (minimum) in the lower part of the attic. Refer to Section 9.19 of the National Building Code for more information. (fig. 5.4) 25 % 25 % 5 General information

Number of ventilators needed for each roof configuration 1 Determine the attic surface area In order to determine the attic surface area of an irregular shaped house, divide the surface into several regular shapes. A B A = 40 ft B = 25 ft C = 15 ft D D = 10 ft C (fig. 6.1) To determine the total surface area, add up the surface of each section: (A x B) + (C x D) = total surface (40 ft x 25 ft) + (15 pi x 10 ft) (1, 000 ft 2 ) + (150 ft 2 ) = 1, 150 ft 2 Total attic surface = 1, 150 ft 2. 2 Determine the number of ventilators required 25 % Refer to section ventilated roof area covered by ventilator in the table found on page 9. This shows the attic ventilator s capacity to ventilate the upper space of the attic. 6 (fig. 6.2) 25 % Be sure to ventilate the lower part of the roof (with soffits and/or air inlet). For more details go to page 5 to see the National Building Code requirements.

For the example on the previous page, model 60300 would be the best choice because it is designed to ventilate roof area from 700 to 1, 200 sq.ft. (fig. 7.1) NOTE : It is important to choose a ventilator that is rated for an area equal or lightly superior to the actual attic surface area to be ventilated. 3 Distribute the ventilation square footage of the attic One ventilator Install the ventilator in the middle of the roof. (fig. 7.2) More than one ventilator Divide the roof into the number of sections equal to the number of ventilators required. Then install the ventilators in the middle of each section. (fig. 7.3) 1/4 1/2 1/4 General information 7

Basic rules 1 The roof must conform to the existing National Building Code It is very important that the attic insulation is distributed evenly. 2 We strongly recommend that you close off the air inlets not related to the attic ventilation. (fig. 8.1) 3 The soffits must not be obstructed and must meet the National Building Code (see page 5). (fig. 8.2) 4 Error : too close to the soffit Make sure that there are no sources of hot or humid air near the different air inlets. If allowed to enter, such heat or humidity will create condensation in the attic and cause material damage to the roof (see page 11). 8 (fig. 8.3)

Venmar attic ventilators Multi-slope base Existing base Flat roof base 60300 60100 60350 60310 60110 Opening(s) 3 1 3 3 1 Net Ventilation 1 ft 2 0.60 ft 2 0.80 ft 2 1 ft 2 0.60 ft 2 Area (93, 000 mm 2 ) (55, 800 mm 2 ) (74, 400 mm 2 ) (93, 000 mm 2 ) (55, 800 mm 2 ) Ventilated roof area 700 to 1, 200 ft 2 0 to 700 ft 2 700 to 1, 200 ft 2 360 to 600 ft 2 0 to 360 ft 2 covered by ventilator* Colors Black 60303 Black 60310 Black 60353 Black 60313 Black 60113 Gray 60305 Gray 60105 Gray 60355 Gray 60315 Gray 60115 Brown 60306 Brown 60106 Brown 60356 Brown 60316** Brown 60116** Dimensions A 20 20 20 20 20 B 18 12 3/4 14 29 3/4 24 1/2 C 10 4 3/4 10 10 4 3/4 D 8 8 4 19 3/4 19 3/4 E 12 1/2 12 1/2-18 1/8 18 1/8 F 20 20-3 5/8 3 5/8 G 12 9/16 12 9/16 12 dia. 12 9/16 12 9/16 Venmar attic ventilators 9 *Calculated for attics which have ventilated soffit around the whole house **Special Order

Recommandations for each type of installation

Soffits obstructed by insulation If insulation obstructs the house soffits, use an attic deflector to move the insulation aside. Attic deflector (fig. 11.1) Closed-in soffits If soffits are permanently closed in, install air inlets. Make sure that the number of air inlets meets the National Building Code (see page 5). (fig. 11.2) Air inlet Obstructed soffits 25 % upper 25 % lower 11 Recommendations for each type of installation

Warm or humid air source If a warm air source is located nearby an air inlet, you should install an extra duct fitted with a damper in order to direct the air away from the inlet. Error : too close to the soffit (fig. 12.1) Gable roof 25 % upper Gables block air entry at the soffits. It is therefore important to follow the National Building Code regarding lower-roof ventilation (see page 5). 25 % lower 12 (fig. 12.2)

Mansard roof The lower part of a mansard roof does not need to be ventilated. However, the upper part must meet the National Building Code (see explanation on page 5). Air inlets 25 % upper Obstructed soffits 25 % lower (fig. 13.1) One-sided cathedral ceiling Install one or more ventilators on the non-cathedral side of the roof. Close off 50 % of the non-cathedral soffits and leave the cathedral side 100% open. 50 % closed off (fig. 13.2) Ouvert à 100% 100 % open 13 Recommendations for each type of installation

Asymmetrical roof (without cathedral ceiling) In this case, close off 50% of the soffit located on the shorter side of the roof and leave the soffit on the longer side completely open. 50 % closed off 100 % open (fig. 14.1) Cathedral ceiling with one slope 100 % closed off Double the planned ventilation 100 % open Close off the soffit on the highest side of the roof and leave the soffit on the lower side completely open. Because of its small space, the air inside the roof warms up very quickly. It is therefore necessary to double the planned ventilation. 14 (fig. 14.2)

Attic ventilator components Gutter Water drainage Base Upper section Gutter Required tools and materials The following is required to install an attic ventilator : Tape measure Saw Exacto-type knife Pencil Spatula Hammer Drill Tar Caulking Level Caulking gun Installation steps 15

Existing roof 1 Determine ventilator position 4 Install the base 1/2 1/4 1/4 Distribute the ventilator(s) evenly over the roof area. Carefully lift up the shingles and slide the ventilator base so that only the side marked A is placed over the shingles (see fig. 16.7). (fig. 16.1) Locate the opening so that the inferior blade of attic ventilator will extend above the roof crest. Remove only those shingles nails located ABOVE and BESIDE the opening. (fig. 16.7) Nail the flat part of the base to the roof, except for the side marked A, in order to prevent water infiltration. Then nail the shingles onto the sides of the ventilator (see fig. 16.6 and 16.7). (fig. 16.2) 2 Create the roof opening (fig. 16.3) Scribe a 12 x12 square on the roof between the rafters (check the position of the rafters from inside the house). Cut the shingles and roofing membrane inside the scribed area and remove them. Cut the opening in the roof. 5 Install the upper section of the ventilator Slide the upper section on the base making sure that it is level. Fit a screw on each side of the ventilator, except for the uppermost side which is inaccessible (screws included). Upper roof Haut de la toiture 3 Prepare the base Apply tar to the underside and topside of the base plate, except on the side marked with an A (see fig. 16.4, 16.5 and 16.6). (fig. 16.8) Lower roof (fig. 16.4) Make sure you do not obstruct the ventilator gutter hole (see fig. 16.5 and 16.6). To ensure water tightness, apply roof caulking to the edges of the base (make sure not to obstruct the ventilator gutter). 16 A (fig. 16.5) (fig. 16.6)

New roof 1 Determine ventilator position 4 Install the base 1/2 1/4 1/4 Distribute the ventilators evenly on the roof. Place the ventilator base on the roof so that only the side marked A is placed on the shingles and the other sides onto the plywood of the roof (see fig. 17.6). A (fig. 17.1) Place the opening so that the inferior blade of the attic ventilator will extend above the roof crest. Nail the flat part of the base to the roof, except for the side marked A (see fig. 17.5 and 17.6). Apply tar to the topside of the base plate, except on the side marked with an A (see fig. 17.6). (fig. 17.5) (fig. 17.2) Continue installing the shingles around the ventilator. (fig. 17.6) 2 Create the roof opening Scribe a 12 x12 square on the roof between the rafters (check the position of the rafters from inside the house). (fig. 17.7) (fig. 17.3) Cut the opening in the roof. Place the shingles up to the lower edge of the hole. 5 Install the ventilator s upper section Slide the upper section on the base making sure that it is level (see fig. 17.8). 3 Prepare the base Fit a screw on each side of the ventilator, except for the uppermost side which is inaccessible (screws included / see fig. 17.5 and 17.6). Apply tar to the underside of the base plate. (fig. 17.4) Make sure you do not obstruct the ventilator gutter hole (see Fig. 17.5). (fig. 17.8) Upper roof Haut de la toiture Lower roof Installation steps To ensure water tightness, apply roof caulking to the edges of the ventilator base (make sure not to obstruct the ventilator gutter). 17

Flat roof 1 Prepare the roof area On the roof cut a 12 x 12 opening. (fig. 18.1) 2 Install the wood base* Install the wood base* over the hole. Nail the wood base* to the roof. (fig. 18.2) Apply the tar on the wood base*. Apply the roofing membrane on the roof until inside the wood base*. (fig. 18.3) 3 Install the upper section of the ventilator Fit a screw on each side Install and nail the ventilator base on the wood base*. Install the upper section on the ventilator base making sure that it is level. Make sure that this one exceeds the edges of the roof. Fit a screw on each side of the ventilator. (fig. 18.4) Important: make sure you include air intake(s) on your roof. 18 (fig. 18.5) * Not included

Five-year Warranty The Venmar Attic Ventilator is made of high-quality 24 and 26-gauge G90 galvanized steel covered with baked enamel polyester paint. Venmar is proud to offer you a five-year corrosion warranty. During this period, Venmar Ventilation inc. will replace the product in-store upon original proof of purchase. IMPORTANT It is the roofer s responsibility to ensure that the base of the ventilator is «completely» watertight by using the appropriate roofing products. The Quebec Association of Master roofers (AMCQ) recommends the following method: Metal Flashing : The flashing must first be coated with a sealer. Then immerse the coated flashing in plastic roofing cement bed and install it on the roof. Brush on hot asphalt then cover with a layer of 15-pond asphalt felt paper. Re-apply hot roofing asphalt and attach a sheet of tar paper or a layer of fibreglass cloth. Cover literally with a final coat of hot roofing asphalt.

Certification Technical data was obtained using CSA s CAN3-A93-M82 Standard and its published results carried out by CRIQ (an industrial research center). For further information, comments, or suggestions, please contact us at Venmar Ventilation inc. 550, Lemire Blvd Drummondville (Quebec) J2C 7W9 Tel: 819 477-6226 Toll-free: 1 800 567-3855 Internet : www.venmar.ca 91077 02/05