Ventilation in traditional houses

Similar documents
gaps between walls or ceilings and cornices fixed air conditioners and heaters construction joints between wall materials

THE CAUSES & EFFECTS OF CONDENSATION IN BUILDINGS

Damp, Mould and condensation. The Facts About

Condensation. Some causes, some advice. GGF Condensation Brochure_web.indd 1

Condensation Control in New Homes. Important information for owners and occupiers

Causes and Advice on Condensation

Your comprehensive guide to: Condensation & Mould Growth

Your guide to condensation and how to reduce it. Come home to comfort

The Art of Building Science

Technical Bulletin 005(B) Developed with Building Standards Scotland

Condensation on Your Windows?

Keep your home free from damp and mould

Attic Condensation. Presented by: Joan Maisonneuve Technical Services

Condensation in your Property. A Homeowners guide to. A guide to the causes and how to remedy the problem

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. What is condensation?

A guide to. e Condensation. and how to reduce it

Healthy Homes Standards

Treating condensation, damp and mould

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Condensation On Windows

The Heating System and Ventilation and Combustion Air

R A Y H U D S O N MAYFAIR W1K. 21 st March 2011

Keeping your home free from Condensation, Mould and Damp

RENTED DWELLING REGULATIONS

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

WHHR Midi & Midi Lite

tççç= ÜÉ~íáåÖ çéíáçåë

Twin Wall Installation Instructions And Maintenance Guide

window condensation Don t let a little moisture cause a big problem

ADVICE NOTE CONDENSATION. How to control condensation problems in your flat

DVS HOME VENTILATION SYSTEMS. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 375 [2014]

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Energy problems in small apartment buildings

NZ s home ventilation specialists

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

5 Sidmouth Avenue Newcastle-under-Lyme, ST5 0QN 475,000

A6VS VENTILATION STANDARDS

Building Science Basics

Energy Ambassadors Guide

Moisture Movement. By Ben Gromicko

Rose Tree Cottage, Hetton

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

your home: Damp, condensation & mould

Enlightened Fresh Air For a Healthy House

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Troubleshooting Guide

Asbestos. asbestos in your home.

Habitability Guidelines

Lucci Designer Hi Flow Exhaust Fan

Green Flag Level Two Survey: Indoor Air Quality Program

Highweek Village, Newton Abbot, TQ12 1QQ 425,000

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Building Regulations Approved Document F1 Means of Ventilation April 2006

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Essex Road, Stevenage, Hertfordshire SG1 3EZ

Dealing with Condensation and Mould Growth.

Lo-Carbon Quadra SELV

(Unless you have supplied it or got it from another organisation) (Unless you put it up without our permission)

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK

INSTALLATION INSTRUCTIONS GB/IE

research highlight Assessment of Suite Compartmentalization and Depressurization in New High-Rise Residential Buildings

Development of Boiler Design

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

anglia Condensation in your property A guide to the causes and how to remedy the problem

murraydonald.co.uk/property

MECHANICAL VENTILATION

A GUIDE TO SELECTING THE RIGHT FAN

Condensation and Mould Advice for Tenants

Inspection Checklist Mechanical Rough in

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

Condensation and Mould

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

GLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY

CHIMNEYS AND VENTS CHAPTER 8

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

LINLITHGOW ELWINSIDE COTTAGE STRAWBERRY BANK, FRIARS BRAE FIXED PRICE 250,000 25,000 BELOW HOME REPORT VALUATION

Controlling condensation in your home

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Permanent Ventilators (for the Supply of Combustion Air)

HOTLINE:

(TAPE #504) Dial-U-TELETIP Script AIR-TO-AIR HEAT EXCHANGERS" Roger A. Peterson

Riva Studio Dedicated Sealed External Air Kit

Tyrwhitt Road Brockley 1,950,000 Freehold

BWTD1 Fully integrated air-vented tumble dryer

Bedford Road, Hitchin, Hertfordshire SG5 2TP

Decorative Fuel Effect Appliances

^ STUV 21: MODEL SPECIFICATIONS

i PSV WHOLE-HOUSE VENTILATION SYSTEM

NORTHSIDE, LOCKERLEY GREEN, ROMSEY, HAMPSHIRE SO51 0JN OFFERS INVITED AROUND 385,000 FOR THE FREEHOLD

London Road, Beccles,, NR34 9NH

Understanding your Central Heating System

Buying & Installation Guide

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Transcription:

Ventilation in traditional houses

Introduction The proper ventilation of living and working spaces is an important consideration in any buildings design and function, both for the good health of its users and the correct performance of its component parts. While to some extent these principles apply to modern structures, they are crucial to the correct function of a traditionally built structure. A traditionally built structure is normally made up of a fairly limited range of largely natural materials, that all transfer or disperse water, or water vapour, fairly easily through and around the structure. Maintaining this free movement of moisture in the air is an important aspect of maintaining your home. Failure to manage ventilation can contribute to a build up of damp in walls and joinery elements, often leading to outbreaks of insect attack and other forms of decay. There is evidence to suggest that poor ventilation can aggravate respiratory diseases and reduce general quality of life of the occupants. This INFORM guide will consider ways to ensure such movement is maintained and consider the various components that make up an appropriate ventilation regime for a traditional structure. Despite recent masonry work to the elevation, this sub floor vent ha Sub floor ventilation Many older buildings have timber floors on the ground floor, built on timber joists over the base of the house (often called the solum) with a void space between. The size of this space varies considerably, but normally joists sit at least a few inches off the ground or solum level. As this space is in close contact with the ground, a free moving air supply is required to ensure the humidity levels are kept low. This ventilation is normally achieved by iron grilles which are often set into the plinth or base course of the house. It is important that these air entry points are kept clear of any obstruction. In many repair projects, such important elements are neglected; rising ground levels, vegetation and even successive over-painting can obstruct these openings and lead to a lack of circulation, resulting in a build up of stagnant air.

is advisable. Invariably condensation forms during the night due to the greater temperature difference. ined blocked; note also the risen ground level. Windows Older windows are often considered draughty; however it is accepted by designers and building control that air changes in a building are essential. Even modern windows, made fully airtight, require a conscious breach of that air tightness in the form of trickle vents. Traditional windows, being less fully sealed, allow an element of trickle ventilation in themselves. A traditional sash window, which allows adjustable air openings at the top and bottom, is able to allow warm moist air (higher up in the room) to escape out the top, and cooler dryer air (from outside) to enter lower down. Adjustment of the sashes can be carried out to achieve the best balance for the prevailing conditions on the day. As a guide to humidity, a rough indicator is that if condensation forms on the window glass during the day, more ventilation Chimneys and flues Although many households do not use wood or coal burning fires for heating, fireplaces and associated flues remain an important element in moisture control and ventilation generally. Regardless of status, most hearths and flues should be kept open, and if not in use, the chimney capped with a well ventilated cowl. Working chimneys assist in drawing out any moisture from the wall core, especially from exposed weather facing gables where water often penetrates. Deposited combustion products within the chimney tend to be hydroscopic and will absorb moisture from the air; for this reason alone an airflow should be maintained. From the mid 19th C cast iron grates were fitted with a hinged iron plate that could be closed shut when the fire was not in use; where this is not available the common solution of a bung of newspaper or rags is sufficient to prevent draughts, but allows some air movement. Hidden ventilation features in Randolph Crescent, Edinburgh The pediment above the door admitted warmed air, and gaps in the cornice (now blocked) allowed it to be drawn away.

is advisable. Invariably condensation forms during the night due to the greater temperature difference. Chimneys and flues Although many households do not use wood or coal burning fires for heating, fireplaces and associated flues remain an important element in moisture control and ventilation generally. Regardless of status, most hearths and flues should be kept open, and if not in use, the chimney capped with a well ventilated cowl. Working chimneys assist in drawing out any moisture from the wall core, especially from exposed weather facing gables where water often penetrates. Deposited combustion products within the chimney tend to be hydroscopic and will absorb moisture from the air; for this reason alone an airflow should be maintained. From the mid 19th C cast iron grates were fitted with a hinged iron plate that could be closed shut when the fire was not in use; where this is not available the common solution of a bung of newspaper or rags is sufficient to prevent draughts, but allows some air movement. Hidden ventilation features in Randolph Crescent, Edinburgh The pediment above the door admitted warmed air, and gaps in the cornice (now blocked) allowed it to be drawn away. Warm air circulation in a Late 19th C town house. From the early 19th C many higher status structures were incorporating sophisticated passive air circulation techniques, mainly using the draw from hearths and flues (see cover illustration featuring a house in Randolph Crescent, Edinburgh, built in 1839) to allow warmed air to circulate through the building. Perforations in the cornice and door mouldings allowed warmed or vitiated air to be drawn up through the floors by the hearths above. In the later 19th C air circulation in houses became quite an advanced part of the design process, chimney flues incorporated foul air flues and other features, especially at the upper end of the residential market, with dedicated boilers heating the air, that ran in special ducts, terminating in decorative grilles in the principal rooms.

In rooms with fireplaces, provision was often made for through floor ventilation. Grilles or vents were fitted in the floor or skirting board either side of the fire place, or close to it. These were fitted to allow the airflow for the fire to come direct from the adjacent area, instead of causing draughts across the room or coming from under the door. humidity reaches a certain point the water will condense on a colder surface, often on an outside window or metal fitting. Reducing the humidity by proper ventilation (window slightly open) and by air coming through from other parts of the house or flat can greatly assist in its reduction. In areas of poor insulation, especially those that are damp, condensation will form even at normal humidity levels, and the reason for this should be investigated and rectified. In addition to natural ventilation from windows, moisture laden air can be removed by active means such as mechanical extract, possibly using redundant chimney flues. In many traditional buildings, where moisture loading was high, such as kitchens, laundries and service areas, many roof spaces were fitted with ventilators, and by the 19th C there were many patented types available, often featuring devices for preventing downdraughts. Where there are encountered they should be maintained. Patent ventilators from C1890. Kitchens and bathrooms Air management is especially important in areas with frequent hot water use, such as kitchens and bathrooms, where a lot of moisture is released into the air. It is important to realise that condensation (water vapour returned to liquid water) is largely the product of those using the building - water vapour from showers, bodies and domestic activity. It is in the poor management of this moisture that leads to condensation. Once the

Fig 5. Loft insulation fitted, but the coombes are kept clear for air movement. Ventilation grille in a late 19th C tenement door. Stairwells and landings In many older houses, tenements or flats, stairwells served as a ventilation pathway. Often at the top, opening onto the roof, were skylights and cupolas, sometimes with adjustable ventilation arrangements. This allowed what is called stack ventilation, whereby hot air rising up through the building was able to escape through the cupola or skylight opening. Cooler air was thus drawn in from other parts of the house, through windows or up through the floors and behind panelling. This natural ventilation feature is utilised extensively in modern low carbon buildings as an alternative to air conditioning or forced draught ventilation. Frequently during repair works these facilities are sealed or removed, causing moist air to accumulate; this moisture then condenses at night onto the glass and timber, causing progressive decay of the timber elements. Where possible such ventilation fittings

should be retained and kept working; a short term repair may cause more extensive problems with the cupola later on. Attics and ceilings Attics are often draughty spaces and where steps are understandably taken to improve insulation but at the cost of reducing air flow. Although this is unquestionably beneficial in energy terms, some thought must be given to ensuring adequate moisture dispersal. Insulation measures should ensure roof voids are adequately ventilated and ventilation from the lower parts of the building, mainly from the gaps between the inner face of masonry and lath and plaster framing and plaster finish, are not closed off. If additional ventilation is required, roof vents can be provided, located discreetly and formed in traditional materials with appropriate detailing. When insulation is applied to the joists in an attic space, avoid fully enclosing the insulation by maintaining an air gap above the insulation layer should attic boards be put down to assist with storage. When packing insulation over the laths over a combed ceiling avoid packing the space tight to the roof sarking, loose fill materials should also be applied in such a way as to allow air circulation. Closed up air vent in public building. A decorative air vent at the top of 19th C stair. When planning re-slating works, ensure that there are gaps between the new sarking boards (traditionally referred to as a penny gap ). These, gaps, when used in conjunction with a breathable roofing paper, will allow sufficient ventilation to prevent condensation in the roof space. Some manufacturers will provide calculations and guidance on roofing papers to ensure the humidity and dew point is designed properly. Signs to look out for Poor air circulation is fairly easy to detect - normally smell will alert a new visitor to a property where ventilation there is poor; regular users of a building may not notice. Cooking smells, for example, will always disperse in a well ventilated property. Some symptoms are closely linked to damp (see Damp INFORM) and again smell, especially in restricted areas such a cupboards, can indicate that air movement behind the framing has been obstructed.

Further reading SPAB Technical Information Sheet No 4 The Need for Old Buildings to Breathe SPAB 1993 Massarwi, I & P, Damp Buildings Old and New, ICROM 1997 Loudon, JC, Encyclopaedia of Cottage, Farm and Villa Architecture and Furniture, Donhead 2000 (reprint) Jackson & Day, Period House, Harper Collins 2005 Gilber. I, The Tenement Handbook, ISBN 978-1873 190 142 Contacts Historic Scotland Technical Conservation Group Longmore House, Salisbury Place, Edinburgh EH9 1SH Tel 0131 668 8668 Email hs.technicalconservationgroup@scotland.gsi.gov.uk Historic Scotland Investment and Projects Team Historic Scotland, Longmore House, Salisbury Place, Edinburgh, EH9 1SH Tel 0131 668 8801 Email hs.grants@scotland.gsi.gov Historic Scotland Inspectorate Historic Scotland, Longmore House, Salisbury Place, Edinburgh, EH9 1SH Tel 0131 668 8716 Email hs.inspectorate@scotland.gsi.gov.uk Principal author: Roger Curtis Published by Technical Conservation Group, October 2008 Historic Scotland, Longmore House, Salisbury Place, Edinburgh EH91SH Tel: 0131 668 8638 Fax: 0131 668 8669 www.historic-scotland.gov.uk email: hs.technicalconservationgroup@scotland.gsi.gov.uk While every care has been taken in the preparation of this book, Historic Scotland specifically exclude any liability for errors, ommissions or otherwise arising from its contents and readers must satisfy themselves as to the principles and practices described.