PREMISES FIRE SAFETY HANDBOOK

Similar documents
PREMISES FIRE SAFETY HANDBOOK

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

PREMISES FIRE SAFETY HANDBOOK

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

EMERGENCY EVACUATION PLAN

EMERGENCY EVACUATION PLAN

BUILDING FIRE STRATEGY

(Fire) Emergency Evacuation Plan

BUILDING FIRE STRATEGY

BUILDING FIRE STRATEGY (Operational & Fire Engineering Information)

BUILDING FIRE STRATEGY

Charlotte Building, 17 Gresse Street, London W1T 1QL

PREMISES FIRE SAFETY HANDBOOK. Institute of Education University College London 20 Bedford Way, London WC1E 6BT

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

BUILDING FIRE STRATEGY (Operational & Fire Engineering Information)

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Fire Safety Policy. Somerville College Woodstock Road Oxford OX2 6HD

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS

EVACUATION PROCEDURES IN EDUCATION PREMISES

Policy for Safe Evacuation of Persons with Disabilities

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

Fire safety procedure

UCL FIRE EXTINGUISHER SCALING & LOCATION POLICY

Fire Safety Protocol

Health and Safety Services. Safety Guide 5. Fire drills

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

University of London

DEF Fire Evacuation and Emergency Planning Criteria

Evacuation Procedures For

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY

PERSONAL EMERGENCY EVACUATION PLANS (PEEP s)

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP

Fire Evacuation Procedure Stroud Campus

FIRE EMERGENCY ACTION PLAN (EAP)

Fire Evacuation Procedure WISE Campus

Wellsprings Primary School. Fire Emergency Evacuation Plan

Fire Safety Awareness Workbook

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

St Edward s Oxford FIRE SAFETY POLICY

Fire and Emergency Evacuation Procedures

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

HEALTH & SAFETY MANAGEMENT ARRANGEMENTS FOR FIRE SAFETY

Department of Biological Sciences National University of Singapore. 4. Procedures: ACTIONS TO BE TAKEN IN THE EVENT OF FIRE DURING OFFICE HOURS

Duties and Responsibilities of Fire Marshals

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

FIRE PROCEDURES 1. APPOINTMENTS

Fire Evacuation Procedure WISE Campus

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

Contents HEALTH AND SAFETY MANAGEMENT SYSTEMS FIRE PREVENTION AND EVACUATION PROCEDURE. 1. Introduction. 2. Warning in the event of fire

Fire Risk Assessment Guidance

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

Fire Safety Policy and Procedures

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

FIRE SAFETY POLICY. Health and Safety. Reviewed by: Health & Safety Committee (2 May 2018) Approved by: Council (25 June 2018)

Fire Safety Procedures and Associated Training

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

Arbour House. Fire Policy and Procedures

Fire Safety Procedures & Risk Assessment Policy

Fire Risk Management Policy. UK September 2017

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

Fire Evacuation Procedure Filton Campus

Fire Safety, Fire Procedures and Fire Risk Assessment Policy. Three Schools Policy

Fire Evacuation Procedure Stroud Campus

NEWBATTLE ABBEY COLLEGE. Fire Safety and Emergency Evacuation Policy and Procedure

FIRE SAFETY AWARENESS

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Fire Safety Policy. Reviewer: Senior Deputy Headmaster Last Reviewed: September Version 1

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Safety Policy. Signed Date September on behalf of the Management Committee. on behalf of The Woodlands

FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS

SHREWSBURY COLLEGE EMERGENCY PROCEDURES. Firearm and Weapon Attacks

Fire Risk Assessment Safety Checklist

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire. This policy applies to all members of our school community, including those within the EYFS setting.

Ruishton C of E Primary School

Evacuation Policy for People with Special Needs

Fire Safety Management Policy. This plan should be read in conjunction with the Health and Safety Policy.

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Ealing Independent College. Fire Policy. This Policy Applies to all students and staff of Ealing Independent College

Millfield Schools Fire Risk Prevention Policy

Transcription:

UCL ESTATES Fire Safety UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK Regulatory Reform (Fire Safety) Order 2005 188 TOTTENHAM COURT ROAD University College London 188 TOTTENHAM COURT ROAD, LONDON, W1T 7PH (UCL Estates seminar rooms only & forms part of 1-19 Torrington Place) Contents 1. Introduction... 1 2. General Building Description... 2 3. Means of Escape (MoE)... 2 4. Instruction to Building Occupants... 3 5. Specific Evacuation Instructions... 4 6. Emergency Disabled Evacuation Provisions... 5 7. Centrally Timetabled Space - Disabled Access Provisions... 6 8. Fire Alarm (specific Information)... 6 9. Fire Extinguishers... 6 INTRODUCTION NOTES This document provides information that you need to know in order to use your building safely whilst complying with UCL policy and fire safety legislation. Each UCL building has been given a risk rating, and this dictates how often fire safety reviews take place, as well as how often departmental staff and fire evacuation marshals should receive full fire safety training. UCL Departments must ensure that: all staff are adequately trained on induction; this training is refreshed periodically (depending on the fire risk rating); fire evacuation marshals (FEM) are appointed for each floor the building; fire evacuation marshals are suitably trained, including refresher trained periodically (depending on the fire risk rating); departmental areas and the risks contained therein are managed safely; appropriate arrangements are in place to ensure the safe evacuation of disabled people; Fire Safety Reviews - UCL Fire Safety Team will periodically carry out fire risk assessments and fire safety reviews. The period in which these reviews will take place will be dictated by the determined risk of the building. Every October - a fire drill will be carried out in most UCL buildings and following the drill, fire FEMs will receive a Toolbox Talk of relevant information to report to their colleagues. A report will be published on line, and this process will act as an annual training supplement to ensure that UCL people remain aware of the significant findings of our fire risk management process. 1. Introduction This short guide provides basic fire safety information to for occupants and visitors to 188 Tottenham Court Road. Date Last Amended: Jan 16 EP: 1 of 6. Issued by: Fire Safety Manager, Safety Services, UCL Estates, Gower Street, London WC1E 6BT / fire@ucl.ac.uk

Premises Fire Safety Handbook Bldg Name: 188 Tottenham Court Road (363) 2. General Building Description For fire safety purposes 188 Tottenham Court Road (Bldg: 363) and 1-19 Torrington Place (Bldg: 086) except for retail shops at ground & lower ground levels are a single building, with interconnecting fire alarm systems. A separate Emergency Plan is provided for 188 TCR and the shops have distinct emergency evacuation arrangements to the UCL Demise, but have a right of escape from lower ground floor through the rear car park of 1-19 TP and out to the street. 1-19 Torrington Place is formed of the Main Tower (East Wing) comprising of ground & 11 storeys with lower ground floor and sub-basement / garage area; and the West Wing, which is over the shops on Tottenham Court Road between first floor & fifth floors attached at upper levels to the main east tower. There is escape to ground level but no separate building access to the west wing except through the main tower (east wing). 188 Tottenham Court Road forms the basement of the west wing with the ground level / lower ground floors occupied by shops & businesses except for the small UCL entrance to sub-basement located at 188 TCR, which has its own separate Fire Strategy (Bldg:363). General arrangement plans are attached including the Fire Assembly Point location 3. Means of Escape (MoE) 3.1. Escape from Basement & Sub Basement Levels (a). Main Entrance & Basement - normal access and egress is via protected main stair ( H) off 188 Tottenham Court Road. (b). Seminar Rooms at Sub-Basement Level SB1 to SB5 - escape is via two x escape stairs: (1). Through SB5 North ( O) - which ascends to lower ground level and discharges into the rear car park area. Once in the car park escape is by travelling across to and up the vehicle ramp onto Torrington Place and proceeding to the Huntley Street fire assembly point. (2). Adjacent to SB1 South ( F) - ascends to street level discharging on Torrington Place adjacent to main staff entrance and proceed to the TCR Fire Assembly Point. 3.2. Note - the Sub Basement area is sprinkled (meaning that any fire will be checked and/or suppressed with water spray automatically, whilst raising the fire alarm summering the fire brigade. Date Last Amended: Jan 16 EP: 2 of 6. Issued by: Fire Safety Manager, Safety Services, UCL Estates, Gower Street, London WC1E 6BT / fire@ucl.ac.uk

Premises Fire Safety Handbook Bldg Name: 188 Tottenham Court Road (363) 4. Instruction to Building Occupants Relevant Information Building Fire Risk Rating: Fire Risk Assessment: Fire Risk Assessment Review: Department Fire Risk Review (iaw TN077): Staff Training (TN086): FEM Training (TN099): Fire Drill: Persons with Disabilities: Other Information: Category 2 Risk. Fire Risk Assessment in this building will be undertaken every 3 years (subject to building changes or alterations) Interim A (Annually) - Fire Safety Staff; Departments - review annually & keep completed copies locally for fire brigade inspection; New Staff Induction - immediate on arrival carry out full walk of building, escape routes & staff member to complete Basic Fire Safety elearning on Moodle Refresher - full training as per induction to be completed by all staff on periods determined in risk rating time line above. (Additional refresher training will be delivered by means of Toolbox Talks. These will be given following fire risk assessments, reviews and fire evacuation drills, at least annually to FEMs. This information will then be cascaded to all staff by FEMs). Minimum number of trained FEMs per floor in this building is: THREE (3) New / Initial FEM training - completed through elearning on Moodle. Refresher - the FEM refresher period is determined in risk rating time line below. (Additional refresher training will be delivered by means of Toolbox Talks. These will be given following fire risk assessments, reviews and fire evacuation drills, at least annually, to FEMs). Scheduled annually for start of term (October) Department to provide PEEPs and specific arrangements (see details below) None Date Last Amended: Jan 16 EP: 3 of 6. Issued by: Fire Safety Manager, Safety Services, UCL Estates, Gower Street, London WC1E 6BT / fire@ucl.ac.uk

Premises Fire Safety Handbook Bldg Name: 188 Tottenham Court Road (363) 5. Specific Evacuation Instructions Local fire information: Fire Notices (and in some premises, additional supplementary instructions) located throughout the premises at fire points and within residential sleeping accommodation rooms provide the local fire Emergency Plan and you should be aware of their contents. on discovering a fire: On discovery or being made aware of a fire, immediately raise the alarm to give warning throughout the building by operating the nearest fire alarm manual call point (red). On hearing the fire alarm: The fire alarm system: Calling the fire brigade: Evacuation procedure and using lifts during fire: Fire Assembly Point: Electronic security door release mechanisms see TN002 and TN004: On hearing the fire alarm, leave the building immediately by the nearest available fire exit (this may not necessarily be the way you entered the building). (1). This building is equipped with a single stage addressable fire alarm system. Which when activated, emits a continuous warning throughout the building. (2). Automatic Fire Detection (AFD) smoke & heat detecting devices are provided for early warning of fire to aid faster escape. (3). Manual Call Points (MCPs) - means for raising the fire alarm in addition to fire detection is by operating MCPs that may be found on routes leading from the building (including corridors, landings, staircases & final exits). Dial Ext: 222 (020-7679-2222) on a UCL Internal Extension and report the fire (use the Building Reference number to assist in identifying the premises or the address shown on the UCL Fire Notices). This building s fire alarm system is monitored on a 24-hour basis who will summon the Fire Brigade. However, you should always make an Emergency Telephone call (Ext: 222 ) to raise the alarm. On hearing the alarm or being directed by a Fire Evacuation Marshal (FEM), occupants are to evacuate the building by the nearest available escape stair, corridor or exit route to the Final Exit from the building. If your escape route is blocked / obstructed by fire or smoke, you should turn your back on the fire and follow the alternative route from the building by following the green fire escape directional signage provided. Lifts should not be used in the event of the fire alarm sounding. On leaving the building you should proceed to the Fire Assembly Point; the location of the Fire Assembly Point(s) is indicated on the local Fire Notices provided, which may also be supplemented with additional information such as local escape route plans etc. Do not obstruct the building entrances as this may hinder access to the fire brigade crews & appliances. Beware of the road traffic and your and others safety during the evacuation! Where fitted doors forming part of the Means of Escape (MoE) may be provided with Electromagnetic Security Locks (Gallagher): (1). Generally, locks release on activation of the fire alarm system (but there are some specialist exceptions to this requirement); (2). Each door in direction of escape is provided with an independent break glass emergency release device (green box) that may be activated to release the door in an emergency. Date Last Amended: Jan 16 EP: 4 of 6. Issued by: Fire Safety Manager, Safety Services, UCL Estates, Gower Street, London WC1E 6BT / fire@ucl.ac.uk

Premises Fire Safety Handbook Bldg Name: 188 Tottenham Court Road (363) 6. Emergency Disabled Evacuation Provisions Relevant Information Mobility Impaired Persons (MIP) or Persons with Disabilities: Personal Emergency Evacuation Plan (PEEP) Disabled Refuge Facilities: (Generally, only provided on individual Risk Assessment or as part of a PEEP initiated by the Department): Disabled Refuge Communications Facilities: (Communication facilities for disabled refuges have BT big button telephone or system complying BS5839-9): Disabled Evacuation Lift: Deaf Persons Fire Alarm Alerting Facilities (change to alerting facilities for hearing impaired people): General Emergency Evacuation Plan (GEEP): Other Information: Department s local management arrangements and fire evacuation strategy for MIP and disabled persons should not rely solely on the Fire & Rescue Service, rescuing people waiting in refuges but for the Department to have satisfactory arrangements in place to assist persons from the building. Managers should review & use the Disable Information Emergency Egress Assessment & personal Emergency Evacuation Plan (PEEP) available from www.ucl.ac.uk/fire/documents under Disabled Some UCL buildings have refuge areas, which are surrounded by fire-resisting construction. These are to be considered as temporary waiting areas only. Disabled people should never be left in the building, as departments must always have sufficient procedures in place to evacuate all relevant persons. The refuge may be used as a safe place for a less ambulant person to wait for everyone else to leave, before making their way down the stairs (with assistance if necessary) at their own pace. (1). Local coms by phone or talk box with local instructions and numbers to call; (2). Mobile Users should call the UCL Security Control Room (available 24/7) who can arrange help and assistance on: 020 7679 3333 (Ext: 33333) Alternative Number (24/7) - 020 7387 5256; UCL Security Ops (24/7) - 020 7679 2108 (Ext: 32108); None Deaf Messaging System (DMS) (see UCL Fire Safety Tech Note TN 007) - a DMS is provided and connected to the fire alarm system to send out a text message upon fire alarm activation to those who have opted into the service. Blue information stickers at the entrance to the building provide the text information and instructions; DMS Ref text 1-19TPDMS30 The building is provided with fire safe lobbies to each stair - which will provide time for arrangements to be made for others to assist. The person you are visiting will take you to the refuge, which is within the evacuation stairway at each level of the building and ensure that FEM s or others are informed that a refuges is being used. If you are able, make you own way down the stairs in your own time, once all other occupants have passed you. 1x refuge provided by horizontal escape into subbasement / garage area of 1-19Torrington Place. Otherwise, no Refuge provided, as basement and other areas of 188 TCR low fire risk and the area is Sprinkled. Date Last Amended: Jan 16 EP: 5 of 6. Issued by: Fire Safety Manager, Safety Services, UCL Estates, Gower Street, London WC1E 6BT / fire@ucl.ac.uk

Premises Fire Safety Handbook Bldg Name: 188 Tottenham Court Road (363) 7. Centrally Timetabled Space - Disabled Access Provisions Centrally Timetabled Lecture Theatres & Seminar Rooms - Mobility Impaired Persons (Wheelchair) Emergency Egress Facilities / Arrangements Lecture Theatre / Seminar Room Locations Accessible / Egress Evacuation Arrangements (None 1 / Limited 2 / Accessible 3 ) Seminar Room B1 (Basement) Level Seminar Rooms SB 1 to SB5 Sub-basement Area None Accessible Not Designated as Wheelchair Accessible Access is via 188 TCR entrance ramp at ground level, and by using lift to sub-basement level. Emergency Egress - proceed to Seminar Room SB5 and leave via the escape stair lobby ( O) into the garage area of 1-19 Torrington Place; then travel up the vehicle ramp to rear car park at lower ground floor level. Once in the car park escape is then via vehicle ramp onto Torrington Place and proceed to the Huntley Street Fire Assembly Point. 8. Fire Alarm (specific Information) Call points - fire alarm manual call points are found in routes leading from the building (including corridors, landings, staircases & final exits), to raise the alarm manually; Sounders - fire alarm sounders provide a two tone electronic sweep sounders; Weekly testing of the fire alarm - see www.ucl.ac.uk/fire/documents TN062; 9. Fire Extinguishers Extinguishers; o Each level contains one x water and 1 x 2Kg Carbon Dioxide extinguishers on backboards at fire points; Fire Blankets - are provided in kitchens and tea points; See www.ucl.ac.uk/fire/documents TN027, TN030 & TN035; Sprinklers - are provided in part of the basement and the garage area only; 1 None - No MIP (specifically wheelchair) Access or Egress available due to location, steps or lifts; 2 Limited - Emergency egress requires management & other assistance, should be planned & written up on PEEP; 3 Accessible - MIP Access and Egress available without general assistance as generally facility where practical to self-escape; Date Last Amended: Jan 16 EP: 6 of 6. Issued by: Fire Safety Manager, Safety Services, UCL Estates, Gower Street, London WC1E 6BT / fire@ucl.ac.uk

Fire 1-19 Torrington Place & 188 Tottenham Court Road On discovering a fire - operate the nearest fire alarm call point. Dial Extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number - 086 & 363 Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road Issued by: the Fire Safety Manager, UCL Estates, Gower Street, London, WC1E 6BT.

Fire 1-19 Torrington Place & 188 Tottenham Court Road Torrington Place Additional Fire Instructions: The fire alarm warning in this building is an electronic alarm with a distinctive: 'TWO TONE' Signal This warning denotes that you are to evacuate the premises immediately by the nearest available exit, on leaving the building proceed directly to a Fire Assembly Point. Do not use the lifts, Do not congregate by the main building entrances, Do not obstruct the road or pavements, TOTTENHAM COURT ROAD QUEENS YARD UCL 188 TCR CAPPER STREET UCL: 1-19 Torrington Place HUNTLEY STREET Fire Assembly Points: Huntley Street Tottenham Court Road TORRINGTON PLACE Issued by: Fire Safety Manager, UCL Estates, Gower Street, London, WC1E 6BT

FIRE ALARM INFORMATION Deaf Messaging Service (Fire Alert) at 1-19 Torrington Place & 188 Tottenham Court Road DEAF TEXT MESSAGING SERVICE INSTALLED in this building To connect to the Fire Alarm Activation Deaf Messaging Service for 1-19 Torrington Pl & 188 TCR TEXT this Location: 1-19TPDMS30 To: 07797-870999 Standard Messaging rate applies for more information and terms & conditions visit: www.alarmscom.co.uk Issued by the: Dec 14 Fire Safety Manager, UCL Estates, Gower Street, London, WC1E 6BT / Tel: 020 7679 1240 / Email: fire@ucl.ac.uk

FIRE ESCAPE PLAN 188 Tottenham Ct. Road Room B1 Basement O N Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086+363 M L K J I Room B1 H G F Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. You are here On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Tottenham Court Road Legend Fire alarm call point Safe refuge Fire extinguisher Emergency exit Plan Ref: 086+36304003/110618

FIRE ESCAPE PLAN Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086 Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. O D E Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road F H Room SB.01 You are here Legend 188 Tottenham Ct. Road Room SB.01 Basement Garage Fire alarm call point Fire extinguisher Safe refuge Emergency exit Plan Ref: 086-36304001/110618

FIRE ESCAPE PLAN Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086 Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. O D E Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road F Room SB.1A H You are here Legend 188 Tottenham Ct. Road Room SB.1A Basement Garage Fire alarm call point Fire extinguisher Safe refuge Emergency exit Plan Ref: 086-36304001/110618

FIRE ESCAPE PLAN Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086 Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. O D E Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road F H Room SB.02 You are here Legend 188 Tottenham Ct. Road Room SB.02 Basement Garage Fire alarm call point Fire extinguisher Safe refuge Emergency exit Plan Ref: 086-36304001/110618

FIRE ESCAPE PLAN Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086 Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. O D E Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road Room SB.03 You are here F H Legend 188 Tottenham Ct. Road Room SB.03 Basement Garage Fire alarm call point Fire extinguisher Safe refuge Emergency exit Plan Ref: 086-36304001/110618

FIRE ESCAPE PLAN Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086 Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. O D E Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. You are here Room SB.04 F When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road H Legend 188 Tottenham Ct. Road Room SB.04 Basement Garage Fire alarm call point Fire extinguisher Safe refuge Emergency exit Plan Ref: 086-36304001/110618

FIRE ESCAPE PLAN Fire On discovering a fire - operate the nearest fire alarm call point. Dial extension '222' on a UCL internal telephone giving the building name and this FIRE ZONE Number 086 O You are here Room SB.05 D E Only attempt to fight the fire, if it is safe and practical to do so - using the most appropriate fire extinguisher for the type of fire you intend to tackle. Do not use WATER on ELECTRICAL or FLAMMABLE LIQUID fires. On hearing the fire alarm - leave the building by the nearest AVAILABLE FIRE EXIT. CLOSE - all doors and windows as you leave. Do NOT - stop to collect belongings. Do NOT - use the lift. Do NOT - re enter the building until instructed to do so by the Senior Fire Officer present. When clear of the building - proceed to your designated FIRE ASSEMBLY POINT at: Huntley Street or Tottenham Court Road F H Legend 188 Tottenham Ct. Road Room SB.05 Basement Garage Fire alarm call point Fire extinguisher Safe refuge Emergency exit Plan Ref: 086-36304001/110618