Isolated Thermocouple Module

Similar documents
Analog Input Module IC670ALG630

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Module Features are-configurable, no module jumpers to set

Duct Mount. Installation Instructions

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

3500/61E & 3500/67E Temperature Monitor

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Figure 1. Figure 2. See notes 1 and 2 below.

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

SEC Signature Process Gas Analyzer

UDC 700 Universal Digital Controllers and Indicator Specifications

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Operating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com

Environmental Monitoring SmartSlot Card

UDC100 Universal Digital Controller Specifications

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Booster Power Supply Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

Remote Sensor Module: EB-RSM-01

Instruction Manual WARNING

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

RAM3 Remote Alarm Module

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

OVEN INDUSTRIES, INC.

Controllers. Instruction Manual WARNING

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Protocol Station Remote Alarm

Remote Relay Module (RRM)

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Instruction Manual Model Backup Switch, 1 for 8

Installation and Operations Manual

INSTALLATION INSTRUCTIONS TALKBACK MODULE

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

Chore-Tronics Load Cell Indicator

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Model 144H. Product Data Sheet , Rev DB February Content

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

CD6102 / CD6102 OC / CD6102-2

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

OPERATING INSTRUCTIONS

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

RC-2000 Thermostat Installation Instructions

* These Remote Mics must be SPRM-GP

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Installation Manual COPYRIGHT NOTICE

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Vanguard. Toxic & combustible gas detector

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

NT DUAL CHANNEL DISPLAY. User Guide

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

FW-RA-LED Remote Multiplex Annunciator Panels

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Beacon 410A Gas Monitor Operator s Manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Mark 25 Ultrapure Water Conductivity Analyzer

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Single Station Remote Alarm

Model 144H. Product Data Sheet , Rev DB February Content

6502B RF Distribution

VNC Versatile Network Controller Operation and Installation Manual

ALM100 Alarm Module. User s Manual

RK Carbon Monoxide Transmitter Operator s Manual

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Nov 08 PRODUCT SPECIFICATION SHEET

SC-6 Six Supervised Control Module

Environmental Monitoring Card

Installation & Operation Manual

Transcription:

User Manual for the HE693THM665, HE693THM666, HE693THM667, HE693THM668 Isolated Thermocouple Module Twelfth Edition 19 April 2004

PREFACE 19 APR 2004 PAGE 3 PREFACE This manual explains how to use the Horner Isolated Thermocouple Module. Copyright (C) 2004 Horner APG, LLC., 640 North Sherman Drive, Indianapolis, Indiana 46201. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior agreement and written permission of Horner APG, LLC. All software described in this document or media is also copyrighted material subject to the terms and conditions of the Horner Software License Agreement. Information in this document is subject to change without notice and does not represent a commitment on the part of Horner APG, LLC. UL is a trademark of Underwriters Laboratories, Inc. CE Mark is a trademark of the European Community. For user manual updates, contact Technical Support at the following locations: North America: (317) 916-4274 www.heapg.com Europe: (+) 353-21-4321-266 www.horner-apg.com

PAGE 4 19 APR 2004 PREFACE LIMITED WARRANTY AND LIMITATION OF LIABILITY Horner APG, LLC. ("HE -APG") warrants to the original purchaser that the Isolated Thermocouple Module manufactured by HE -APG is free from defects in material and workmanship under normal use and service. The obligation of HE-APG under this warranty shall be limited to the repair or exchange of any part or parts which may prove defective under normal use and service within two (2) years from the date of manufacture or eighteen (18) months from the date of installation by the original purchaser whichever occurs first, such defect to be disclosed to the satisfaction of HE-APG after examination by HE-APG of the allegedly defective part or parts. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES AND HE-APG NEITHER ASSUMES, NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR HE-APG, ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS Isolated Thermocouple Module. THIS WARRANTY SHALL NOT APPLY TO THIS Isolated Thermocouple Module OR ANY PART THEREOF WHICH HAS BEEN SUBJECT TO ACCIDENT, NEGLIGENCE, ALTERATION, ABUSE, OR MISUSE. HE-APG MAKES NO WARRANTY WHATSOEVER IN RESPECT TO ACCESSORIES OR PARTS NOT SUPPLIED BY HE-APG. THE TERM "ORIGINAL PURCHASER", AS USED IN THIS WARRANTY, SHALL BE DEEMED TO MEAN THAT PERSON FOR WHOM THE Isolated Thermocouple Module IS ORIGINALLY INSTALLED. THIS WARRANTY SHALL APPLY ONLY WITHIN THE BOUNDARIES OF THE CONTINENTAL UNITED STATES. In no event, whether as a result of breach of contract, warranty, tort (including negligence) or otherwise, shall HE -APG or its suppliers be liable of any special, consequential, incidental or penal damages including, but not limited to, loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, down time costs, or claims of original purchaser's customers for such damages. To obtain warranty service, return the product to your distributor with a description of the problem, proof of purchase, post paid, insured and in a suitable package. ABOUT PROGRAMMING EXAMPLES Any example programs and program segments in this manual or provided on accompanying diskettes are included solely for illustrative purposes. Due to the many variables and requirements associated with any particular installation, Horner APG cannot assume responsibility or liability for actual use based on the examples and diagrams. It is the sole responsibility of the system designer utilizing the Isolated Thermocouple Module to appropriately design the end system, to appropriately integrate the Isolated Thermocouple Module and to make safety provisions for the end equipment as is usual and customary in industrial applications as defined in any codes or standards which apply. Note: The programming examples shown in this manual are for illustrative purposes only. Proper machine operation is the sole responsibility of the system integrator.

PREFACE 19 APR 2004 PAGE 5 REVISIONS TO THIS MANUAL 1. Revised Table 1.1. 2. Revised Section 3.1 Example 3. Revised Table 3.2.

PAGE 6 19 APR 2004 PREFACE

PREFACE 19 APR 2004 PAGE 7 TABLE OF CONTENTS PREFACE...3 LIMITED WARRANTY AND LIMITATION OF LIABILITY...4 ABOUT PROGRAMMING EX AMPLES...4 REVISIONS TO THIS MANUAL...5 TABLE OF CONTENTS...7 CHAPTER 1: INTRODUCTION...9 1.1 Description...9 1.2 Specifications... 10 CHAPTER 2: INSTALLATION... 11 2.1 Wiring... 11 2.2 External Cold Junction Compensation... 12 2.3 Remote Terminal Strip (Isothermal Block).... 13 CHAPTER 3: CONFIGURATION... 15 3.1 Foreign Module Configuration... 15 3.2 Configuration Parameters... 16 3.3 Temperature Scaling... 16 CHAPTER 4: DIGITAL FILTERING... 17 4.1 THM 668 and THM667 Digital Filtering... 17 4.2 THM666 and THM665 Digital Filtering... 17 CHAPTER 5: ALARMS & SETPOINTS... 19 5.1 Alarms... 19 5.2 Alarm Setpoints... 19 CHAPTER 6: CONFORMANCE STANDARDS... 21 6.1 CE Mark and Compliance with EMC Directive... 21 CHAPTER 7: RECOMMENDATIONS & APPROVALS... 23 7.1 UL Approved... 23 7.2 Installation Hints and Recommendations... 23

PAGE 8 19 APR 2004 PREFACE

CH. 1 19 APR 2004 PAGE 9 CHAPTER 1: INTRODUCTION 1.1 Description The Isolated Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PC without external signal processing (transducers, transmitters, etc.). All analog and digital processing of the thermocouple signal is performed by the module. These backplane-isolated (or bus-isolated) modules report temperature values to the PLC I/O table in increments of 0.5 C, 0.5 F, 0.1 C, or 0.1 F respectively. The module features six thermocouple channels whose temperature values are reported to 6 %AI input registers. Each channel can be individually configured for a specific type of sensor wire. There are 6 %I alarm bits and one setpoint alarm for each channel. (The HE693THM667 has 12 alarm bits and two setpoints per channel.) Alarm setpoints are configured for each channel using 6 %AQ registers. An available feature on the isolated thermocouples is the use of external AD592 cold junction compensation. This allows cold junction compensation to be accomplished in a remote isothermal terminal strip with standard copper wire run from the remote terminal strip to the module. There are four versions of the Horner APG Isolated Thermocouple Input Module: HE693THM668, HE693THM667, HE693THM666 and HE693THM665. The HE693THM668 is a six-channel module with +/-1500V AC isolation to the PLC backplane and +/-250V AC isolation channel-to-channel. The HE693THM667 is similar to the HE693THM668 except that the HE693THM667 has 2 setpoints per channel. The HE693THM666 is equivalent to the HE693THM668 with the addition of a 60Hz notch filter. The HE693THM665 is also equivalent to the HE693THM668 with addition of a 50Hz notch filter. The purpose of these filters is to eliminate noise generated by power lines in the United States (60Hz) and Europe (50 Hz). Figure 1.1 View of Isolated Thermocouple Module

PAGE 10 19 APR 2004 CH.1 1.2 Specifications Specification Power Consumption Number of Channels Types Supported Backplane Isolation Channel Isolation A/D Conversion Time Common Channel Points Operating Temperature Operating Mode Input Range (Temp) Table 1.1 - Specifications THM668, THM667, THM666, THM665 Specification 200mA @ 5VDC I/O Points Required 6 J,K,N,T,E,R,S,B,C ±1500 VAC to PLC backplane ±250V AC channel-tochannel 5ms NONE 0 to 60 C (32 to 140 F) J: -210 to +760 C E: -270 to +1000 C K: -270 to +1372 C C: 0 to +2320 C R: 0 to +1768 C Self-Scan T: -270 to +400 C N: -270 to +1300 C S: 0 to +1768 C B: +45 to +1820 C Input Impedance Maximum Sustained Differential O/L Common Mode Rejection A/D Conversion Type Scan Rate Open Thermocouple Response Relative Humidity Resolution Accuracy THM668, THM667, THM666, THM665 6%AI, 6%AQ, 16%I 1000M ohms @ < 100mV ±35V >100dB 18-bit integrating 40 channels per second Programmable Upscale or Downscale 5% to 95% non-condensing 0.5 C, 0.5 F, 0.1 C, 0.1 F J: ± 1.0 C S: ± 2.0 C T: ± 1.0 C E: ± 2.0 C K: ± 1.0 C B: ± 2.0 C 100 to 1820 C N: ± 1.0 C R: ± 2.0 C C: ± 4.0 C

CH. 2 19 APR 2004 PAGE 11 CHAPTER 2: INSTALLATION 2.1 Wiring The following figures illustrate the connections for proper thermocouple use. Figure 2.1 depicts normal connections. Figure 2.2 depicts the proper connections with the use of the optional remote terminal strip. Figure 2.1 Normal Wiring Connections

PAGE 12 19 APR 2004 CH.2 AD592 located on Remote Isothermal Block Figure 2.2 Wiring Connections for Optional Remote Terminal Strip 2.2 External Cold Junction Compensation The THM668 supports remote cold junction compensation. This allows the thermocouple sensors to be connected to a remote terminal strip. Standard shielded copper wiring can then be run between the remote terminal strip and the module terminal strip. The remote terminal strip must be "isothermal" in nature. It should be constructed with a built-in AD592 temperature sensor and even thermal characteristics. The module can detect the presence of an external AD592 temperature sensor and perform cold junction compensation based upon the remote sensor instead of the module's on-board AD592. Horner APG offers an isothermal remote terminal strip (HE693ISOBLK). See Section 2.3 for more information on the HE693ISOBLK.

CH. 2 19 APR 2004 PAGE 13 THM668 THM667, THM666, THM665 Channel 1 Channel 2 Table 2.1 Connections Between Remote Terminal Strip and ISOBLK Module Isothermal Isothermal Module THM668 Isothermal Isothermal Module Block Block DB25 Terminal THM667, Block Block Terminal Screw Pin THM666, Screw DB25 Pin Terminal THM665 Terminal TC-1 3 7 Channel 5 TC-5 7 12 TC+1 16 9 TC+5 20 14 TC-2 4 11 Channel 6 TC-6 8 16 TC+2 17 13 TC+6 21 18 NC 1 2 SHIELD 25 19 Not Connected NC 14 1 SHIELD 13 20 Channel 3 TC-3 5 15 Not Used TC-7 9 NC TC+3 18 17 TC+7 22 NC Channel 4 TC-4 6 8 Not Used TC-8 10 NC TC+4 19 10 TC+8 23 NC 2.3 Remote Terminal Strip (Isothermal Block). The Horner APG HE693ISOBLK is a remote terminal strip which can be used in conjunction with the HE693THM668/667/666/665. It features an isothermal terminal strip, with integrated AD592 temperature sensor. Connections between the remote terminal strip and the isolated thermocouple module are accomplished through a DB25 connector. Pinouts for the ISOBLK screw terminals, DB25 connector, and the isolated thermocouple terminal strip are shown as follows. Cabling constructed by the customer connects the ISOBLOCK s DB25 female connector and the THM668/667/666/665 module s terminal strip. Figure 2.3 - Pinouts

PAGE 14 19 APR 2004 CH.2 NOTES

CH. 3 19 APR 2004 PAGE 15 CHAPTER 3: CONFIGURATION 3.1 Foreign Module Configuration Figure 3.1 depicts the Foreign Module Screen. Figure 3.1 Foreign Module Screen To reach this screen, select I/O Configuration (F1), cursor over to the slot containing the module and select Other (F8), and Foreign (F3). Example. The example screen above defines the following configuration parameters: %I Ref. Adr : %I1 Starting reference for 16 %I bits. %I Size : 16 Alarm bits (first six successive bits used for the six channels). 32 (for THM667) %Q Ref. Adr. : 0 Not Used. %Q Size : 0 Not Used. %AI Ref. Adr %AI1 Starting reference for 6 %AI words. %AI Size : 6 Registers used to store temperatures. %AQ Ref. Adr. :%AQ1 Starting reference for 6 %AQ words. %AQ Size : 6 Registers used to store setpoint values for alarm bits. 12 (for THM667) Byte 1 : 1 Smart Module. Byte 2 : 10 Digital filter set to 4 samples (Binary numbers only). Byte 3 2 Resolution format set to 0.1 degrees Celsius. Byte 4 : 0 Open thermocouple response set to Upscale. Byte 5 : 0 Channel 1 configured to use J-type sensor wire. Byte 6 : 1 Channel 2 configured to use K-type sensor wire. Byte 7 : 0 Channel 3 configured to use J-type sensor wire. Byte 8 : 1 Channel 4 configured to use K-type sensor wire. Byte 9 : 4 Channel 5 configured to use E-type sensor wire. Byte 10 : 2 Channel 6 configured to use N-type sensor wire. Byte 11 : 0 Use internal cold junction compensation.

PAGE 16 19 APR 2004 CH. 3 3.2 Configuration Parameters Necessary parameters are %I Size, %AI Size, %AQ Size, and Bytes 1-11. %I Size %AI Size 16 *32 (*THM667) 6 6 Table 3.2 Configuration Parameters %AQ Size Byte 1 Byte 2 Byte 3 Byte 4 Byte 5-10 Byte 11 *12 (*THM667) Smart Module 1 Digital Filter Format Resolution 00: 0.5 C 01: 0.5 F 02: 0.1 C 03: 0.1 F Up/Down Break 00: Upscale Break 01: Downscal e Break T/C Type 00: Type J 01: Type K 02: Type N 03: Type T 04: Type E 05: Type R 06: Type S 07: Type B 08: Type C 09: OFF Cold Junction 00: Internal 01: External 3.3 Temperature Scaling Temperature values are written to the %AI registers in 0.1 C, 0.1 F, 0.5 C or 0.5 F increments depending upon the value of Byte 3. Table 3.4 Temperature Scaling BYTE 3 Format Resolution Formula 00 0.5 C 0.5 C = %AI / 2 01 0.5 F 0.5 F = %AI / 2 02 0.1 C 0.1 C = %AI / 10 03 0.1 F 0.1 C = %AI / 10

PAGE 17 19 APR 2004 CH.4 CHAPTER 4: DIGITAL FILTERING 4.1 THM 668 and THM667 Digital Filtering The effect of digital filtering (set with Byte 2) on module response to a temperature change. The THM665 and THM666 are approximately 4 times slower due to the effects of the filtering. (% Temp Change Completed vs. Time). THM668/THM667 Digital Filtering 100% % Temperature Change Completed 90% 80% 70% 60% 50% 40% 30% 20% 10% 1 10 11 100 101 110 111 0% 0 2 4 6 8 10 12 14 16 18 20 Response Time (seconds) Figure 4.1 Digital Filtering of the HE693THM668 & HE693THM667 4.2 THM666 and THM665 Digital Filtering The effect of digital filtering (set with Byte 2) on module response to a temperature change. The THM665 and THM666 are approximately 4 times slower due to the effects of the filtering. (% Temp Change Completed vs. Time). THM665/THM666 Digital Filtering 100 % Temperature Change Completed 90 80 70 60 50 40 30 20 10 1 10 11 100 101 110 111 0 0 15 31 46 61 77 92 107 Response Time (seconds) Figure 4.2 Digital Filtering of the HE693THM666 & HE693THM665

PAGE 18 19 APR 2004 CH. 4 NOTES

CH. 5 19 APR 2004 PAGE 19 CHAPTER 5: ALARMS & SETPOINTS 5.1 Alarms Table 5.1 indicates the alarm bits (16 %I) and setpoints (6 %AQ) for the THM668,THM666,and THM665. Also shown are the alarm bits (32%I) and setpoints (12%AQ) for the THM667. Table 5.1 Alarm Bits and Setpoints THM668, THM666, & THM665 THM667 %AQ 1-6 %I 1-16 %AQ 1-12 %I 1-32 %AQ1 = ch. 1 setpoint %I1 = ch. 1 open alarm %AQ1 = ch. 1 high %I = ch. 1 open alarm %AQ2 = ch. 2 setpoint %I2 = ch. 2 open alarm %AQ2 = ch. 2 high %I2 = ch. 2 open alarm %AQ3 = ch. 3 setpoint %I3 = ch. 3 open alarm %AQ3 = ch. 3 high %I3 = ch. 3 open alarm %AQ4 = ch. 4 setpoint %I4 = ch. 4 open alarm %AQ4 = ch. 4 high %I4 = ch. 4 open alarm %AQ5 = ch. 5 setpoint %I5 = ch. 5 open alarm %AQ5 = ch. 5 high %I5 = ch. 5 open alarm %AQ6 = ch. 6 setpoint %I6 = ch. 6 open alarm %AQ6 = ch. 6 high %I6 = ch. 6 open alarm %I7 = Not Used %AQ7 = ch. 1 low %I7 = Not Used %I8 = Not Used %AQ8 = ch. 2 low %I = Not Used %I9 = ch. 1 setpoint alarm %AQ9 = ch. 3 low %I9 = ch. 1 setpoint alarm %I10 = ch. 2 setpoint alarm %AQ10 = ch. 4 low %I10 = ch. 2 setpoint alarm %I11 = ch. 3 setpoint alarm %AQ11 = ch. 5 low %I11 = ch. 3 setpoint alarm %I12 = ch. 4 setpoint alarm %AQ12 = ch. 6 low %I12 = ch. 4 setpoint alarm %I13 = ch. 5 setpoint alarm %I13 = ch. 5 setpoint alarm %I14 = ch. 6 setpoint N/A alarm %I14 = ch. 6 setpoint alarm %I15 - %I 6 = Not Used %I15 - %I6 = Not Used %I17 - %I 4 = Not Used %I 5 = ch. 1 low alarm %I26 = ch. 2 low alarm %I 7 = ch. 3 low alarm %I 8 = ch. 4 low alarm %I29 = ch. 5 low alarm %I 0 = ch. 6 low alarm %I31 = Not Used %I32 = Not Used 5.2 Alarm Setpoints There are three reference types used with the THM668/667/666 and 665: a) %I b) %AI c) %AQ

PAGE 20 19 APR 2004 CH. 5 The 6 %AI registers report the temperature in the selected format. The 6 %AQ registers (or 12 %AQ for the THM667) can be used to configure the alarm setpoint registers. The 16 %I bits (or 32 %I bits for the THM667) display the alarm conditions. The first six %I are set (1) if the respective thermocouple channel is over the maximum readable temperature or is open. The ninth through the fourteenth %I bits are set while the temperature is above the value specified in the respective %AQ. The setpoint is in the same format as the temperature. The THM667 uses 6 additional %AQ registers (12 %AQ total) and 16 additional %I bits (32 %I total). The first 6 %AQ registers are used to store the corresponding high alarm setpoints while the second 6 %AQ registers store the low alarm setpoints. The first 6 %I bits are allocated for open-channel alarm status. %I 7 and 8 are not used. %I 9-14 are used as a high alarm status bit for each of the six corresponding thermocouple channels. %I 17-24 are not used. The 25th through the 30th %I bits are set while the temperature is below the specified value in the respective %AQ. %I 25-30 are used as a low alarm status bit for each of the six corresponding thermocouple channels. %I30 and 31 are not used. See Table 5.1 for more details. a) Example: Module Configuration is %I1-16, %AI1-6, %AQ1-6 with temperature format = 0.5 C. %AQ1 (channel 1 setpoint) is set to a value of 200 (100 C). %I 1 will remain open (0) unless the temperature reaches the maximum readable value or is open and %I9 will be set high (1) while the temperature is equal to or above 100 C. In other words, if %AI1 is greater than or equal to %AQ1, then %I9 = 1 and %I1 = 0 unless open or maximum readable value is reached.

CH. 6 19 APR 2004 PAGE 21 CHAPTER 6: CONFORMANCE STANDARDS 6.1 CE Mark and Compliance with EMC Directive The Isolated Analog Input Thermocouples are CE-marked to indicate compliance with the EMC Directive. The EMC Directive is concerned with the immunity of electrical equipment to a variety of interference sources and the emissions from electrical equipment which could interfere with the operation of other equipment. The EMC Directive applies to complete installations, and since Horner APG products are included in the installation, Horner APG is supporting the EMC Directive by testing and CE -marking a subset of our equipment Horner APG meets the following criteria covered under the EMC Directive including: a) 89/336/EMC b) 92/31/EEC c) 93/68/EEC Figure 6.1 CE Mark In order to meet CISPR (EN 55011) Group 1, Class A Radiated Emissions levels, all components in the PLC system require the following: a) General 1) All components must be mounted in a metal enclosure or the equivalent. The wiring must be routed in metal conduit or the equivalent. All surfaces of the enclosure must be adequately grounded to adjacent surfaces to provide electrical conductivity. 2) The metal conduit (flexible conduit is acceptable) for all wiring external to the cabinet must be mounted to the enclosure using standard procedures and hardware to ensure electrical conductivity between the enclosure and the conduit. 3) An external EMI filter must be wired to the AC Main for the PLC. Sprague Electric Part Number 259A9098P3 (available from GE Fanuc), or any other EMI filter which provides equivalent performance, may be used. 4) An external ground wire (16 AWG (1.32 mm2), 6" (15.24 cm) maximum length) must be wired from the Series 90-30 power supply safety ground wire terminal to the metal enclosure 5) On AC Main Ports connected to PLC s, MOVs shall be connected Line to Line and Line to Ground. 6) All cables and Analog signals must use shielded cable with a minimum of overall foil.

PAGE 22 19 APR 2004 CH. 6 b) Specifics 1. The thermocouple sensor wire(s) must be fully shielded and grounded to pin 19 and/or 20. 2. The thermocouple sensor wire(s) must have external clamps on Ferrites added when the cable length is greater than or equal to 3 meters.

CH. 7 19 APR 2004 PAGE 23 CHAPTER 7: RECOMMENDATIONS & APPROVALS 7.1 UL Approved The THM668 has met the requirements for Underwriters Laboratories, Inc. Class I Div 2. Figure 7.1 UL Approval 7.2 Installation Hints and Recommendations a) Use fully-shielded high-grade thermocouple sensor wire. Shielded, twisted pair extension wire offers the best noise immunity. b) Extension wiring must be routed in its own conduit. c) A good earth ground is critical for the shielded wire. d) Do not expose the module(s) to excessive EMI or RF interference. e) Do not expose the module(s) to extreme temperature variations. f) Module(s) must be allowed to stabilize for at least 15 minutes after complete connection and power-on. g) Module(s) must be in the upright position (panel-mounted position). h) Special care must be taken with grounded junction sensors to avoid applying a voltage potential to the thermocouple junction. i) Extension wire of the proper sensor type must be used. j) Keep wire lengths to a minimum.

PAGE 24 19 APR 2004 CH. 7 NOTES