TECHNICAL DATA. Wet 26a. February 22, 2009

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

Instructions for Installation, Operation, Care and Maintenance

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

DISCONTINUED PRODUCT

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

Finishes Plain Brass Chrome Plated and other Finishes Available Upon Request. For cabinets and other accessories refer to separate sheet.

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

Victaulic Europe Phone: Fax:

TotalPac 3 Wet pipe system c/w retard chamber

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Finishes Plain Brass Chrome plated and other fin ishes available upon request. For cabinets and other accesso ries refer to separate sheet.

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

mechanical. OPERATION Rapidrop Global

DISCONTINUED PRODUCT. reference publication

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Electric Release Panel Wiring Tips

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

A. This section includes design and performance information for fire protection and suppression systems.

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

SECTION AUTOMATIC SPRINKLER PIPING

Model DDX Deluge Valve

FireLock NXT TM Automatic Valve Systems

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

TECHNICAL DATA OBSOLETE

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

10.85 VicFlex Sprinkler Fittings

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

TECHNICAL DATA. 319a. January 27, 2012

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

VicFlex TM Stainless Steel Sprinkler Fittings

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

Gas Station & C Store SECTION CWM Job No

SECTION SPRINKLER SYSTEMS

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TotalPac 3 Firecyle III Deluge Remote controlled system

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

All electrical systems and components require CSA approval stamped on the nameplate of the heater.

ADDENDUM NO. 3 March 19, 2018

Worldwide Contacts. Technical Data

SECTION FIRE-SUPPRESSION STANDPIPES

SECTION WET-PIPE FIRE-SUPPRESSION SPRINKLERS

Technical Data. Sizes 2 12 Inch (DN50 DN300)

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

TotalPac X Single interlock SUREFIRE system

FIRELOCK NXT AUTOMATIC VALVE SYSTEMS NOT JUST VALVES SIMPLICITY.

SECTION DRY-PIPE SPRINKLER SYSTEMS

40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

OPEN SPRINKLER SYSTEM

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

SECTION WET-PIPE SPRINKLER SYSTEMS

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION WET-PIPE SPRINKLER SYSTEMS

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

TotalPac X Firecycle III Preaction Double interlock system

Flow Control for Fire Protection

WET-PIPE SPRINKLER SYSTEMS

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

SECTION FIRE PROTECTION

TOTALPAC2 Integrated Fire Protection System

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

2. Welding Materials and Procedures shall conform to the ASME Code.

Flow Control for Fire Protection

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Copyright 2016 AIA MasterSpec Full Length 09/16 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO VICTAULIC COMPANY.

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

North Hanover Township School District North Hanover Township, New Jersey

Transcription:

R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.70 Series 759 FireLock Alarm Check Valve Grooved Grooved PRODUCT DESCRIPTION U L FM U L C See Victaulic publication 10.01 for details. The Victaulic Series 759 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve is trimmed with a water bypass line, which has an in-line swing check valve. The bypass line allows pressure surges to enter the system and to be trapped above the alarm check valve s clapper without the clapper lifting and causing false alarms. When a significant flow of water occurs, such as from an open sprinkler head, the alarm valve s clapper lifts and allows water to enter the system. Simultaneously, water enters an intermediate chamber, which allows the water to activate an alarm either through a water motor alarm or through a water pressure alarm. These alarms continue to sound until the flow of water is stopped. The Victaulic Series 759 alarm check valve is made from high strength, low weight ductile iron, and offers easy access to all internal parts. All internal parts are replaceable without having to remove the valve from the installed position. The rubber clapper seal is easily replaceable. The valve can be installed in either the vertical or horizontal orientations, and it can be used in both constant and variable pressure systems when the optional retard chamber is included in the trim piping. The 3-8" (88,9-219,1 mm) valve is rated to 175 psi (1200 kpa) and is tested hydrostatically to 350 psi (2400 kpa). The Series 759 is available grooved grooved (all sizes). Standard grooved dimensions conform to ANSI/AWWA C606. Also available in JIS standard sizes. Options Optional equipment includes a non-interruptible pressure switch, which allows the activation of an electric alarm panel or remote alarm. The valve can be used in both constant pressure and variable pressure installations with the optional retard chamber. The body is tapped for main drain and all available trim configurations. The trim includes an alarm test valve, which allows testing of the alarm system without reducing the system pressure. Series 759 can be purchased with separate trim kits, for either the vertical or horizontal configurations. VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Phone: 1-800-PICK-VIC (1-800-742-5842) Fax: 610-250-8817 e-mail:pickvic@victaulic.com Victaulic Company of Canada Phone: 416-675-5575 Fax: 416-675-5565 e-mail: viccanada@victaulic.com Victaulic Europe Phone:32-9-381-1500 Fax: 32-9-380-4438 e-mail: viceuro@victaulic.be Victaulic America Latina Phone: 610-559-3300 Fax: 610-559-3608 e-mail: vical@victaulic.com Victaulic Asia Pacific Phone: 65-235-3035 Fax: 65-235-0535 e-mail: vicap@victaulic.com 3034 Rev.C 11/01 Registered Trademark of Victaulic Copyright 2001 Victaulic Printed in U.S.A.

DIMENSIONS Standard Trim D G B A I C E F H D VALVE SIZE Nominal inches Actual mm GROOVED GROOVED Dimensions inches/mm A B C D E F G H I Aprx. Wgt. Each lbs./kg Without Trim 3 10.50 17.00 24.00 9.00 11.00 13.00 5.00 5.00 2.00 17.0 29.0 88,9 266,7 431,8 609,6 228,6 279,4 330,2 127,0 127,0 50,8 7,7 13,2 76,1 mm 10.50 17.00 24.00 9.00 11.00 13.00 5.00 5.00 2.00 17.0 29.0 266,7 431,8 609,6 228,6 279,4 330,2 127,0 127,0 50,8 7,7 13,2 4 11.37 17.00 27.00 9.00 15.00 12.00 5.00 6.00 2.00 30.0 40.0 114,3 288,5 431,8 685,8 228,6 381,0 304,8 127,0 152,4 50,8 13,6 18,1 6 14.10 19.00 30.00 10.00 16.00 14.00 6.00 7.00 1.00 63.0 73.0 168,3 358,1 482,6 762,0 254,0 406,4 355,6 152,4 177,8 25,4 28,6 34,0 165,1 mm 14.10 19.00 30.00 10.00 16.00 14.00 6.00 7.00 1.00 63.0 73.0 358,1 482,6 762,0 254,0 406,4 355,6 152,4 177,8 25,4 28,6 34,0 8 17.00 22.00 32.00 10.00 16.00 16.00 7.00 8.00 94.0 109.0 219,1 431,8 558,8 812,8 254,0 406,4 406,4 177,8 203,2 N/A 42,6 49,4 With Trim Excess Pump Trim D K G B A J C E F I H D VALVE SIZE Nominal inches Actual mm GROOVED GROOVED Dimensions inches/mm A B C D E F G H I J K Aprx. Wgt. Each lbs./kg Without Trim 3 10.50 12.00 28.00 8.00 12.00 17.00 7.00 5.00 2.00 13.00 5.00 17.0 29.0 88,9 266,7 304,8 711,2 203,2 304,8 431,8 177,8 127,0 50,8 330,2 127,0 7,7 13,2 76,1 mm 10.50 12.00 28.00 8.00 12.00 17.00 7.00 5.00 2.00 13.00 5.00 17.0 29.0 266,7 304,8 711,2 203,2 304,8 431,8 177,8 127,0 50,8 330,2 127,0 7,7 13,2 4 11.37 14.00 32.00 9.00 15.00 17.00 7.00 6.00 2.00 12.00 5.00 30.0 40.0 114,3 288,5 355,6 812,8 228,6 381,0 431,8 177,8 152,4 50,8 304,8 127,0 13,6 18,1 6 14.10 16.00 36.00 10.00 16.00 20.00 9.00 7.00 1.00 14.00 6.00 63.0 73.0 168,3 358,1 406,4 914,4 254,0 406,4 508,0 228,6 177,8 25,4 355,6 152,4 28,6 34,0 165,1 mm 14.10 16.00 36.00 10.00 16.00 20.00 9.00 7.00 1.00 14.00 6.00 63.0 73.0 358,1 406,4 914,4 254,0 406,4 508,0 228,6 177,8 25,4 355,6 152,4 28,6 34,0 8 17.00 18.00 38.00 10.00 17.00 21.00 9.00 8.00 0.50 15.00 7.00 94.0 109.0 219,1 431,8 457,2 965,2 254,0 431,8 533,4 228,6 203,2 12,7 381,0 177,8 42,6 49,4 With Trim 10.70-2

PERFORMANCE PRESSURE DROP PSI 6.0 5.0 4.0 3.0 2.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 HYDRAULIC FRICTION LOSS FLOW OF WATER AT +65 F (+18 C) THROUGH FULL OPEN VALVE 76,1 mm; 3" (88,9 mm) 4" (114,3 mm) 165,1 mm; 6" (168,3 mm) 8" (219,1 mm) SERIES 759 0.3 0.2 0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE GPM The chart at right expresses the frictional resistance of Victaulic Series 759 Alarm Check Valve in equivalent feet (meters) of ANSI standard wall straight pipe. FRICTIONAL RESISTANCE SIZE Nominal Inches Actual mm Equivalent Length of Pipe Feet/meters 3 16 88,9 4,9 76,1 mm 16 4,9 4 26 114,3 7,9 6 32 168,3 9,8 165,1 mm 32 9,8 8 27 219,1 8,2 Expressed in equivalent length of pipe C=120. 10.70-3

TRIM PACKAGES Trim packages available: 1. Vertical trim for the Series 759 Alarm Check Valve installed vertically. 2. Horizontal trim configuration for the Series 759 Alarm Check Valve installed horizontally. Trim packages include: 1. All required pipe and fittings. 2. All standard trim accessories. 3. All required gauges. Optional accessories: Series 752 Retard Chamber - Required when the Series 759 Alarm Check Valve is installed in a variable pressure installation in order to reduce the possibility of false alarms. Series 760 Water Motor Alarm - The Series 759 Alarm Check Valve is designed to activate a mechanical alarm when a sustained flow of water (such as an open sprinkler head) causes the alarm check s clapper to lift from its seat. Alarm pressure switch - The Series 759 alarm check valve is designed to allow the installation of pressure switches to activate electric alarms and control panels when a sustained flow of water (such as an open sprinkler head) causes the alarm check s clapper to lift from its seat. Waterflow Detectors: Waterflow detectors are available for installation on the riser. MATERIAL SPECIFICATIONS Body: Ductile iron, conforming to ASTM A-395, grade 65-45-15, and ASTM A-536, grade 65-45- 12 Clapper: Ductile iron, conforming to ASTM A-395 Shaft: Type 304 Stainless steel Clapper Seal: EPDM, ASTM D2000 Seat O-rings: EPDM Springs: Stainless steel (300 Series) Quantity 1 6 & 8" Valves 3" Valve 4" Valve (168,3 & No. Part Name (88,9 mm) (114,3 mm) 219,1 mm) 1 Valve Body 1 1 1 10 2 Cover Plate 1 1 1 3 Cover Plate Bolt 5 5 5 9 4 5 2 3 8 7 6 11 15 14 4 Cover Plate Gasket 1 1 1 5 Clapper Spring 2-Part 1-Part 2-Part 6 Shaft Retaining Plug 2 2 2 7 Clapper Arm Washer 2 2 2 8 Clapper Shaft 1 1 1 9 Spring Bushing 2 1 0 10 Clapper 1 1 1 11 Clapper Seal 1 1 1 12 12 Brass Clapper Retaining Ring 1 1 1 13 Exaggerated for Clarity 13 Bolt/Washer 1 1 1 14 Seat O-Ring 1 1 1 15 Seat Ring 1 1 1 10.70-4

LISTED FM PARTS With Vertical Trim Grooved Grooved 4 WATER MOTOR ALARM SERIES 760 U L C 10 2 9 6 3 1 To Water Motor Alarm Open Optional Retard Chamber Assembly 5 8 7 BILL OF MATERIALS 1 Series 759 FireLock Alarm Valve 6 Alarm Test Line Ball Valve (NC) 2 Water Supply Pressure Gauge (0-300 psi) 7 Alarm Line Drain Restrictor (¹ ₁₆") 3 By-Pass Check Valve 8 Main System Drain Valve 4 System Pressure Gauge (0-300 psi) 9 Series 752 Retard Chamber (Optional) 5 Alarm Line Ball Valve (NO) 10 Series 760 Water Motor Alarm (Optional) 10.70-5

PARTS With Horizontal Trim Grooved Grooved To Water Motor Alarm Optional Retard Chamber Assembly Open 10.70-6

LISTED FM PARTS FOR CANADA ONLY Series 759 Trim for Use with Excess Pressure Pump Grooved Grooved 4 Pressure Switch To Water Motor Alarm From Excess Pressure Pump 3 Flow Switch Open 2 From Excess Pressure Pump WATER MOTOR ALARM SERIES 760 U L C 10 6 1 9 Open 5 8 7 BILL OF MATERIALS 1 Series 759 FireLock Alarm Valve 6 Alarm Test Line Ball Valve (NC) 2 Water Supply Pressure Gauge (0-300 psi) 7 Alarm Line Drain Restrictor (¹ ₁₆") 3 By-Pass Check Valve 8 Main System Drain Valve 4 System Pressure Gauge (0-300 psi) 9 Alarm Pressure Switch EPS-10 5 Alarm Line Ball Valve (NO) 10 Series 760 Water Motor Alarm (Optional) 10.70-7

OPERATION The Series 759 Alarm Check Valve s construction includes a clapper, which has a replaceable rubber face. The clapper closure is assisted by a spring, which ensures proper contact of the clapper to the brass seat ring. When installed, the alarm check valve traps pressure above the clapper and prevents the reverse flow of water. Minor pressure surges pass through the bypass loop without lifting the clapper from its seat. The swing check valve in the bypass line traps the pressure above the clapper; this can be observed in the pressure gauges. The system-side water pressure will always be equal to or greater than the supply-side water pressure in the absence of an open sprinkler head. When a sustained flow of water occurs, such as an activated sprinkler head or an open inspector s test connection, the clapper lifts from its closed position; this allows water to enter the intermediate chamber through the holes in the seat ring. The water flows from the intermediate chamber to the alarm line and activates the system s alarms. These alarms continue to sound until the flow of water stops. Operation with an Installed Retard Chamber When the Series 759 Alarm Check Valve is installed with the optional retard chamber, a surge of water, greater than what the bypass line can handle, will lift the clapper. When the clapper lifts, water will enter the intermediate chamber through the holes in the seat ring, and it will fill the retard chamber. The water then drains from the retard chamber through a restricted orifice. A sustained flow of water, as in an open sprinkler head, will lift the clapper. Water will flow into the intermediate chamber, and it will fill the retard chamber completely; these events activate the water motor alarm and/ or the pressure switch for the electric alarm. This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 10.70-8