Similar documents
Long lasting unit provided by heavy-duty, corrosion-resistant, galvanized steel construction.

Helps reduce cycle time and increase productivity with advanced SPRAY-CURE technology.

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

STR-Series Indirect-Fired Air Turnover Units

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

Contents INDEX. TDM Series Indirect Fired Heaters

13 GEP A L P - 1 A

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL SPECIFICATIONS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SUBMITTAL SCHEDULE & DATA

SKYPAK II, 3 Ton Series, gives you a

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

RGE 13 A T - 1 A

Equipment Specifications

Now In Production JULY 2008

TSTAT0201CW Recommended (sold separately)

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Q-Tec TM QC-Series Chilled Water Air Conditioner

PART NO. COMBUSTION AIR TERMINATION CAP

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

General Description. Operation

Q-TEC QC-Series Chilled Water Air Conditioner

PART NO. COMBUSTION AIR CAP

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

U n i t H e at e r s

PART NO. THROUGH THE ROOF VENT CAP

Plenum Fans. Model HPA. Direct Drive

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

LUH HORIZONTAL FAN-FORCED UNIT HEATER

48TM GAS HEATING/ELECTRIC COOLING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Cooling Capacity CFM in. w.c. (125 Pa)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

48TF GAS HEATING/ ELECTRIC COOLING UNITS

SKYPAK II Heating & Cooling Self Contained Packages

MERIT SERIES Downflow

TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

F Series - Refrigeration dryers

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

SKYPAK II, 3 Ton Series, gives you a

TSTAT0101SC Recommended (order separately)

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Center Mount Unit Coolers

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

2 shp 13 lc 1 36 t - 1 a

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

ELITE SERIES Downflow - High Efficiency Blower Motor

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Appendix 13. Categories of Cooling and Heating systems

G6RC Series TECHNICAL SPECIFICATIONS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

CoolSpot Engineering Guide

RSG16**S1M. Split System Air Conditioner 16 SEER

INDIRECT GAS-FIRED AIR HEATER

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

TECHNICAL SPECIFICATIONS

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

VERT-I-PAK SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Wt. Lbs Model Number (BTUH) Hz

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

System Control. Installation, Operation & Service Manual WARNING. Installer

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

RG7D 1-Stage Heat Series

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

GB Condensing Gas Boiler

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Installation, Operation & Service Manual

Direct Fired Heater Model AD Specification

Transcription:

7400-Series Small Indirect-Fired Air Turnover Units For Heating and/or Cooling Applications Industry-Leading 85% Efficient Burner Exceeds market benchmarks for drum-and-tube indirect-fired air turnover equipment. Can be ideal for smaller commercial, institutional and industrial spaces: Compact design allows unit to be placed in facilities with ceiling height as low as 13ft. Dependable, Trustworthy Operation: Unit includes touchsafe electrical panel, factorymounted rotary disconnect, high temperature limit switch and power cut-off switches at inlet plenum access as standard. Helps minimize heat stratification: Can maintain uniform vertical and horizontal building temperatures. Unique, Modular Design: Cooling module can be added to non-cool units in field. 1.800.536.3461 www.rapidengineering.com

PID 7400-Series PID small air turnover units are typically installed in new or retrofit commercial and industrial applications. Reliable, Efficient System Operation Provided by: Four-sided inlet and three-sided discharge plenums with grilles to provide consistent and efficient air movement throughout the space. High temperature limit switch, which monitors discharge temperature to prevent an overheating situation. Power burner with built-in combustion fan to eliminate induced draft fan in flues less than 40ft in length. Factory-mounted rotary disconnect which automatically cuts power to unit when control enclosure door is opened. Touch-safe electrical panel to prevent finger access to hazardous components. Two-stage, R410A A-frame cooling coil, mounted above heat exchanger. Unit-mounted seven-day programmable thermostat with fan-only and temporary override features. Ease of Maintenance Provided by: Filters housed in filter racks located on exterior of inlet plenum for easy cleaning and changing. Fan and fan motor easily accessible through inlet plenum. Exterior-mounted burner assembly provides unobstructed access for operation and maintenance. Long Lasting Construction Provided by: Fully-painted cabinet that provides long-lasting and visually-pleasing unit exterior. Heavy-duty durable propeller fan with 10 gauge blades and heavy-gauge welded venturi frame for low ambient sound. Multi-pass, drum-and-tube heat exchanger consisting of 321 stainless steel primary drum and mild steel secondary tubes. Premium efficiency, totally-enclosed fan-cooled (TEFC) motor as standard to protect against damage. Self-standing cabinet composed of 20 ga galvannealed steel. Suit Most Applications with Availability of: Natural gas or LPG burner. Cooling coil assembly that can retrofit air-only or heat-only units in the field. Units for single-phase, three-phase and 575 V applications. Optional matching condenser unit for cool-only and heat-cool units. PID 7400-Series Applications Automotive Centers. Maintenance Facilities and Industrial Facilities Heat-cool unit can quickly achieve space temperature setpoint after opening and closing of bay doors. Commercial Spaces Heat-cool units can maintain year-around comfort in open commercial spaces such as showrooms. Indoor Sports Facilities 100% return air operation helps provide quick recovery of space temperature when switching from unoccupied periods to occupied periods. Pharmaceutical/Cosmetic Storage Heat-cool unit can maintain strict FDA-stipulated temperature ranges for regulated products. Retrofit Facilities Units require no ductwork that could potentially conflict with other product or equipment in the space. Warehousing and Storage Areas Constant circulating airflow keeps dust from settling on boxes, helps prevent consumer perception of "old parts".

PID 7400-Series Technical Data and Clearances Technical Data Airflow 7400-142 120/1/60 230/1/60 208/3/60 230/3/60 460/3/60 575/3/60 [CFM] 10,000 10,000 10,000 10,000 10,000 10,000 [m 3 /h] 16,990 16,990 16,990 16,990 16,990 16,990 Number of Propeller Fans -- 1 1 1 1 1 1 Propeller Fan Diameter [in] 42 42 42 42 42 42 Sheave Type -- Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable Fan Motor Size [HP] 3* 5 5 5 5 5 Fan Motor Type -- Single Speed, Premium Efficiency, TEFC Total Input [Btu/h x 1000] 400 400 400 400 400 400 [kw] 117.2 117.2 117.2 117.2 117.2 117.2 Total Output [Btu/h x 1000] 340 340 340 340 340 340 [kw] 99.6 99.6 99.6 99.6 99.6 99.6 Efficiency [%] 85 85 85 85 85 85 Gas Connection [in] 3/4 3/4 3/4 3/4 3/4 3/4 [cm] 1.9 1.9 1.9 1.9 1.9 1.9 Minimum Inlet Gas Pressure [in wc] 5.5 5.5 5.5 5.5 5.5 5.5 Maximum Inlet Gas Pressure [in wc] 14 14 14 14 14 14 Flue Diameter [in] 5 5 5 5 5 5 [cm] 12.7 12.7 12.7 12.7 12.7 12.7 Maximum Flue Length [ft] 40 40 40 40 40 40 [m] 12.2 12.2 12.2 12.2 12.2 12.2 Cooling Capacity [T] 20 20 20 20 20 20 [kw] 70.3 70.3 70.3 70.3 70.3 70.3 Refrigerant -- R410A R410A R410A R410A R410A R410A Coil Design -- A-frame A-frame A-frame A-frame A-frame A-frame Coil Circuits -- 2 2 2 2 2 2 Coil Circuit Design -- Intertwined Intertwined Intertwined Intertwined Intertwined Intertwined Disconnect Fuse Size [A] 50 40 25 25 15 12 Full Load Amps [A] 39.0 24.5 18.0 17.0 9.5 8.2 Fan Motor Current Draw [A] 34.0 20.5 14.0 13.0 6.5 5.2 Burner Current Draw @ 120V [A] 12.0 12.0 12.0 12.0 12.0 12.0 Controls Current Draw @ 120V [A] 5.0 5.0 5.0 5.0 5.0 5.0 * Note that a 120/1/60 unit is not available for heat-cool operation Weights 7400-142 Clearances to Combustibles 7400-142 Air-Only Unit Heat-Only Unit Cool-Only Unit Heat-Cool Unit [lb] 1200.0 [kg] 544.3 [lb] 1400.0 [kg] 635.0 [lb] 1350.0 [kg] 612.3 [lb] 1550.0 [kg] 703.1 Top Sides Around Flue [in] 18.0 [cm] 45.7 [in] 18.0 [cm] 45.7 [in] 18.0 [cm] 45.7 Unit ships in two pieces.

PID 7400-Series Dimension Data H H DA DISCHARGE PLENUM DA G DA SPLIT FOR SHIPMENT COIL SECTION F J INSPECTION AND RELIEF PORT Q R P HEAT EXCHANGER SECTION E BURNER BURNER SECTION L M N D CONTROL PANEL K INLET PLENUM / FAN SECTION C A B S DIMENSIONS A B C D E F G H J K L M N P Q R S [in] 50.1 53.2 21.6 37.7 24.9 25.8 34.2 5.0 5.0 7.0 16.0 18.3 15.9 144.2 4.0 11.0 65.1 [cm] 127.3 135.1 54.9 95.8 63.2 65.5 86.9 12.7 12.7 17.8 40.6 46.5 40.4 366.3 10.2 27.9 165.4 IMPORTANT NOTES: All dimensions are subject to change without notice. Due to height of unit, additional support is recommended for top of unit. FILTERS Filter Qty Filter Size Filter Type 2 8 [in] [cm] [in] [cm] 20 x 20 x 1 50.8 x 50.8 x 2.5 16 x 20 x 1 40.6 x 50.8 x 2.5 30% Polyester 30% Polyester LEGEND DA = Discharge Air = Return Air

PID 7400-Series Configurations Air-Only Unit Heat-Only Unit Cool-Only Unit Heat-Cool Unit Note: Not available for 120/1/60.

Thank You for Your Business! Installation Code and Annual Inspections: All installation and service of PID equipment must be performed by a contractor qualifi ed in the installation and service of equipment sold and supplied by Rapid Engineering LLC and conform to all requirements set forth in the Rapid Engineering LLC manuals and all applicable governmental authorities pertaining to the installation, service, operation and labeling of the equipment. To help facilitate optimum performance and safety, Rapid Engineering LLC recommends that a qualifi ed contractor conduct, at a minimum, annual inspections of your PID equipment and perform service where necessary, using only replacement parts sold and supplied by Rapid Engineering LLC. Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through PID representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual. These products are not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Rapid Engineering LLC 1100 Seven Mile Road NW Comstock Park, MI 49321 Telephone: +1.616.784.0500 Toll Free: 800.536.3461 Fax: +1.616.784.1910 www.rapidengineering.com 2013 Rapid Engineeing LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Rapid Engineering LLC. Printed in U.S.A. RP7400BNA 1M 0713 Rev A