ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Similar documents
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Installation and Maintenance "L" and "LS" Series

Installation and Testing of Inverted Bucket Steam Traps Manual

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Clean Steam Generators

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

INSTRUCTION MANUAL HS-229G

Rada 25R Installation and Maintenance

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

TITAN FLOW CONTROL, INC.

Industrial Vacuums, Inc

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

Service Parts, Kits and Accessories

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

INSTALLATION, OPERATION

Sound Cover [ , , , ]

MN908 No. 282C Replaces 282B LB7013

INSTRUCTION MANUAL HS-208REVI

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. QuickTrap FX1 Trap Unit X1. Manufacturer

Design Criteria. Installation

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Bulletin 301-N SERVICE GUIDE. Armstrong Inverted Bucket Steam Traps

Rada 320R Installation and Maintenance

TrueClean ToteCleaner

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS FS SERIES. QuickTrap FS3/FS5/FS5H.

mechanical. OPERATION Rapidrop Global

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

SERVICE GUIDE Armstrong Inverted Bucket Steam Traps

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

INSTALLATION, OPERATION

Inverted Bucket Steam Traps

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

XT Series Thermostats

Ace Heaters LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Ace Heating Solutions, LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

AeroVent 3X Product Manual

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Installation Instructions PP-AS20 Anti-Scale System

MaxLite LED MICRO-T PANEL

INTERMEDIATE GUIDE BRACKET

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Operation & Maintenance Manual

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

MEMOIRS VITREOUS CHINA TOILETS

HotPoly Tote Tank / IBC Heaters (TTH Series)

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

TOUCHDOWN 48 CEILING FAN

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

TrueClean ToteCleaner

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

INSTALLATION, OPERATION

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.

Torrena 42 Ceiling Fan

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

Installation & Maintenance Instructions

Camarillo 52 Ceiling Fan

Corrosion Resistant Fluid and Air Handling Systems.

Duct Mount. Installation Instructions

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

INSTALLATION AND OPERATION INSTRUCTIONS

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

THE THERMOSTATIC STEAM TRAP

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

VSA/VSB & KSA/KSB Series Air Doors

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

NXT Hg5 Amalgam Separator Installation and Operations Manual

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Hg5 Amalgam Separator Installation and Operations Manual

Pressurized Filter Up to 1250 gallons

Installation, Operation and. Maintenance Instructions

NXT Hg5 mini Amalgam Separator Installation and Operations Manual

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Transcription:

ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59

Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting. 8 Torque values. 9 Repair Parts. 10 Warranty Terms 11 2

General Safety Information Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance of the Armstrong ICS Float and Thermostatic steam trap. Selection or installation of equipment should always be accompanied by competent technical assistance. You are encouraged to contact Armstrong International, Inc. or its local sales representative for additional information. 2017 Armstrong International, Inc. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 3

Product Information 1. Product Information: The ICS Float and Thermostatic steam trap is used for continuous drainage of condensate and high-capacity venting of air and Co 2, when steam pressure may vary from maximum steam supply pressure to vacuum. 1.1. Product Range Armstrong ICS Float and Thermostatic steam trap is available with flanged connections of 150RF, 300RF, PN40RF, socket weld and screwed connections in 1/2 (15 mm), 3/4 (20 mm), 1 (25 mm), 1-1/2 (40 mm) and 2 (50 mm) sizes with a maximum operating pressure to 465 psig (32.0 barg). Refer table 4.1. Connection Size 1/2 (15 mm) 3/4 (20 mm 1 (25 mm) 1-1/2 (40 mm) 2 (50 mm) Orifice Size in (mm) PMO psig (barg) 11/64 (4.3) 75 (5.1) 1/8 (3.1) 150 (10.3) 7/64 (2.8) 175 (12.0) 3/32 (2.4) 225 (15.5) 5/64 (2) 300 (20.6) 1/16 (1.6) 465 (32.0) 5/16 (8) 40 (2.7) 1/4 (6.3) 65 (4.4) 7/32 (5.5) 100 (6.8) 3/16 (4.8) 150 (10.3) 5/32 (4) 200 (13.6) 1/8 (3.2) 300 (20.6) 3/32 (2.4) 465 (32.0) 1-3/8 (35) 100 (6.8) 1 (25) 200 (13.7) 3/4 (20) 465 (32.0) Table 4.1 Figure 4.1 4

Product Installation 2. Installation 2.1. Pre-Installation Before installing the trap, blow down piping that leads to the trap inlet. Purpose of blowing down is to clean the line out of any debris that could damage the trap. Make sure that the Maximum Operating Pressure (PMO) of the trap is adequate for the installation. (The PMO is stamped on the nameplate). 2.2. Installation of ICS F&T Trap Install so the trap inlet is below the outlet of the equipment to be drained. Use good piping practices. Make inlet piping as short as possible. Use a minimum number of elbows and other restrictions in inlet and outlet piping. Install a dirt pocket in the line ahead of the trap. To allow maintenance and provide maximum service, install a valve on each side of the trap and a downstream testing tee. All valves should be of the full ported type to avoid restricting flow. Provide a strainer ahead of the inlet. Install a union upstream and downstream of the trap unless the discharge line is open and short. Avoid elevating the condensate if the equipment is under modulated control. If the discharge piping is to be elevated, ensure that adequate differential pressure exists always to provide proper drainage. When elevating condensate, install a check valve in the discharge piping near the trap to prevent backflow when the system is not in operation. Figure 5.1 5

Service and Maintenance 3. Service and Maintenance 3.1. Repairing the Trap Close the inlet and outlet valves. Make sure that the trap is cold and then drain the body. Unscrew the cap bolts and carefully remove the body. Remove the mechanism. Discard the old gasket and clean gasket surfaces. Clean any dirt or sediment from the trap body, cap, and mechanism. Check that the cap is free from erosion. Inspect the mechanism for signs of wear or damage. (See Inspection below). Replace the worn or damaged parts (see Replacing the Mechanism on page 7). Install a new gasket in the body and secure the body to the cap using a cross-tightening pattern. See table 8.1 and figure 9.1. Once all the bolts have been securely tightened and the drain plug re-installed, open the valves in the supply and discharge lines. Check the equipment for normal operation. 3.2. Inspection Linkages should be free to move without excessive wear. Valve lever and clip pin holes should be round, not elongated. A properly seating valve has a bright narrow ring all the way around its circumference. A properly wearing seat has a uniform edge with no nicks or wire drawing. Always replace valve and seats as a matched pair. Thermostatic air vent should be replaced at the same time you replace the valve and seat assembly. Floats should show no dents or creases. Shake the float; it should not contain any liquid. Look for pinhole leaks, especially along the seams. If you suspect a leak, immerse the float in hot water and look for bubbles rising to the surface of the water. 3.3. Remove the worn parts - Sizes 1/2 (15 mm), 3/4 (20 mm), 1 (25 mm) Remove the lever and float assembly by pulling out the pivot pin. Remove the valve lever clip by unscrewing the seat. Inspect the valve and seat for wear. If float or lever is damaged, unscrew the float screw to remove the float. Remove thermostatic air vent and replace with new element. 3.4. Installing new mechanism parts Secure the valve lever clip by threading the valve seat through it into the cap. Apply a drop of thread lock compound to the float screw and assemble the float to the lever assembly. Attach the valve lever assembly by inserting the pivot pin and check it for proper alignment. With the valve firmly seated, slide the lever pin back and forth to ensure it moves freely. If it does not, bend the ears on the valve lever clip in or out as needed until it does. 6

Service and Maintenance Continued 3.5. Replacing the mechanism - Sizes 1-1/2 (40 mm) and 2 (50 mm) Clean and inspect the cap to body and cap extension gasket surfaces. Check to see if the erosion shield fits tightly into the cap extension and is flush with the gasket surface. Place the cap extension gasket over the erosion shield and place the cap extension with erosion shield into the cap. MAKE SURE THE EROSION SHIELD OUTLET IS POINTING TOWARDS THE OUTLET CONNECTION. Screw one cap extension bolt (on the outlet side) into the cap and loosely tighten it. Place the other cap extension bolt through the baffle, cap extension and loosely tighten it into the cap. Place another cap extension bolt through the baffle, spacer and tighten it into the cap. Tighten all three bolts, evenly, to 140-170 lbs (190-230 N-m) Screw thermostatic air vent into the cap, using new gasket, to 20-30 ft-lbs (27-40 N/m) 7

Troubleshooting 4. Troubleshooting Problem Causes Solution Steam loss No condensate discharge If trap operates satisfactorily when discharging to atmosphere, but trouble is encountered when connected with the return line Thermostatic element damaged Thermostatic element s gasket damaged Worn valve parts Float punctured or deformed Piece of scale lodged in orifice Back pressure may reduce capacity of trap Replace it Replace it Clean the orifice Check whether, return line is too small Check whether, other traps are blowing steam Table 8.1 8

Torque Value 5. Torque Value Connection Size Bolt Size Torque Value 1/2 (15 mm) 3/4 (20 mm) 7/16-14 UNC 48 Lbf-ft (65 N-m) 1 (25 mm) 1/2-13 UNC 66 Lbf-ft (90 N-m) 1-1/2 (40 mm) 2 (50 mm) M16x2 66 Lbf-ft (90 N-m) Thermostatic Capsule 63 Lbf-ft (85 N-m) Seat (Size: 1/2 (15mm) 1 (25mm)) 49 Lbf-ft (67 N-m) Cap extension (size: 1-1/2 (40mm) 2 (50mm)) 22 Lbf-ft (30 N-m) Table 9.1 Cross Tightening Patterns 6 1 6 BOLT 4 3 2 5 Figure 9.1 9

Repair Parts 6. Repair Parts Size Orifice Mechanism (less float) 1/2 (15 mm) 3/4 (20 mm) 1 (25 mm) 1-1/2 (40 mm) 2 (50 mm) 11/64 C5149-1 1/8 C5149-3 7/64 C5149-4 3/32 C5149-5 5/64 C5149-6 1/16 C5149-7 5/16 C5150-1 1/4 C5150-2 7/32 C5150-3 3/16 C5150-4 5/32 C5150-5 1/8 C5150-6 3/32 C5150-7 20 mm C6213 25 mm C6209 35 mm C6200 Gasket D14236 D11994 Mechanism s Gasket NA Float Capsule Capsule s Gasket A21803 A4751 C6260 B7549 B6991 B2465-3 B2465-3 Table 10.1 1/2, 3/4, and 1 Traps 1-1/2 and 2 Traps Figure 10.1 Figure 10.2 10

Limited Warranty and Remedy 7. Warranty Terms Armstrong International, Inc. or the Armstrong division that sold the product ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory, [unless a Special Warranty Period applies, as listed below]. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. 11

Armstrong provides intelligent system solutions that improve utility performance, lower energy consumption, and reduce environmental emissions while providing an enjoyable experience. Armstrong International North America Latin America India Europe / Middle East / Africa China Pacific Rim armstronginternational.com 59 Printed in U.S.A. - 03/17 2017 Armstrong International