COVER PLATE GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL

Similar documents
INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve

Reserve Exposed Thermostatic Valve Installation Instructions

Butler Mill and Brassworks Ltd. Exposed 1/2 Thermostatic Valve Installation Instructions

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

Installation Instructions / Warranty

Installation Instructions / Warranty. Massaud

Installation Instructions / Warranty. PuraVida 15775XX1

Installation Instructions / Warranty

Installation Instructions / Warranty. Metris 31060XX XX XX1

Installation Instructions

TUB AND SHOWER FAUCET

Installation Instructions Model: EB Single-Lever Lavatory Faucet

Installation Instructions / Warranty

Installation Instructions / Warranty

1/7 SPOUT INSTALLATION

Faucet Care and Maintenance Guide. Answers to frequently asked questions on how to keep your Delta faucets at their best

Installation Instructions / Warranty

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

Installation Instructions / Warranty

Installation Instructions / Warranty

Shower Heads EDO COLLECTION

Owner s. 18 Misting MF18W. To view

TUB AND SHOWER FAUCET

Installation Instructions / Warranty. Starck 10111XX XX XX1

PL-004-SS. * Proper water pressure is required for simultaneous operations

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Single Lever Pull Out Kitchen Faucet

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Version: 1.1 INSTALLATION GUIDE WATERFALL SHOWER SYSTEM

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

SAVE THESE INSTRUCTIONS

I mpo rta n t : Please re g is t e r y ou r p rod uct onli ne at www. santecfaucet. com wi thi n 30 da ys o f pu rc h as e. S an t e c reser v e s

INSTALLATION FOR THERMOSTATIC VALVES

Installation & Operation Manual

BATHTUB INSTALLATION MANUAL

Thermostatic Valve and Trim

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

Forteza Series Granite Kitchen Sink

Installation Instructions

Models: FM FM WARNING

Finished Excellence. Limited Lifetime Finish Warranty. Armaturen.Accessoires.Interiors.Culture Projects.

PD-811 PD-811 propriétaire Owner s manual Manuel du PD D P

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS. Uptown Contempo Widespread Faucets Part # s: 8880-****, 8881-****

Whole House Filter Model: WH-LD

Spa Control System OWNER S MANUAL

INSTALLATION INSTRUCTIONS

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Karbon Kitchen Sink Tap

Model pictured: ST6001

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

O w n e r s M a n u a l

(The chances are you re never going to read me) Owner s Manual.

Installation Instructions

Thermostatic Concealed Shower Valve

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

CORALAIS BODYSPA BATH AND SHOWER FAUCET

INSTALLATION INSTRUCTIONS (please become familiar with these instructions before installing).

MODENA ZUHNE

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

O w n e r s M a n u a l

Flipside Handshower and Showerhead Installation and User Guide

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

ERGOMAX 7 INSTALLATION

Central Brass. Installation Guide C O M P A N Y

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

Installation and User Guide

TIMES SQUARE TWO-HANDLE THERMOSTAT

MINIATURE THERMOSTATIC VALVE

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL


Laundry Kit With flexi-neck faucet and storage cabinet

Single Handle Lavatory Faucet

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Solinder Single Lever Basin Faucet

Murano Shower Cabin Installation Instruction

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

RIGA ZUHNE

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

OWNER S MANUAL & WARRANTY

Installation Instruction

Use and Care Manual VERONA 32 OM 16 GAUGE STAINLESS STEEL SINGLE BOWL OVERMOUNT SINK ZUHNE

Artisan Thermostatic Bath Filler

ispring Whole House Water Filter Systems USER S MANUAL

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.]


INSTRUCTION MANUAL HS-229G

Aquila Single Lever Vessel Faucet

Transcription:

Sigmatherm INSTALLATION INSTRUCTIONS 1" & 1-1/4" Thermostatic Mixing Valve Single Exit For use with 1" and 1-1/4" Copper Pipe Only 0 SHUT-OFFS PLASTIC HOUSING BUSHING SQUARE TUBE THERMO POINTER ASSEMBLY THREADED TUBE NOTE: NEVER CUT INSIDE THREAD END COVER PLATE SIGMA ESCUTCHEON GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL SIGMA HANDLE This valve is single exit only. (Top Exit) Bottom outlet is for draining valve only and is supplied with a plug. Installation Please Note: The first step in installation, removal of the cartridge, has already been done at the factory. The cartridge has been packaged separately from the valve body to prevent clogging the cartridge during installation. Install the cartridge only when the hot and cold water lines are flushed and fully operational. The water heater must be working or the unit will not work. We recommend the installation of in-line plumber supplied shut-off valves close to the hot and cold inlets. Please remember the cartridge should be removed and cleaned annually for optimum useful life of the system. The following parts may be ordered to extend stem: 4-1/2 Threaded Tube (Part #18.30.088) 5 Square Tube (Part #18.30.087) Cover Page 1 of 9

Connections Installation Instructions For 1" and 1-1/4" Valves Assembly USE TOP EXIT ONLY SIZE COPPER PIPE TO MATCH VALVE PORTS Plug on bottom of valve for draining body in case of severe cold temperature. Reverse steps performed when removing the cartridge to re-install the cartridge (see p. 3 for diagram). Assemble the cartridge (2), the cover (3) with its screws, fit the threaded tube (9), and screw home. Place the plate (7) and the dial (11) onto the assembly. Make a cutting mark 3/16" from the dial face. Remove the tube, cut it, and debur the cut carefully. Screw the tube home again. -Important- Connect the hot water to the side with the red mark and the cold water to the side with the blue mark. The plastic housing should act as a depth guide for the plumber. Install the valve so the housing extends beyond the finish wall 1/2". Cut the plastic housing flush with the FINISH wall. The plastic housing is to remain with the valve body always for maintenance reasons. Valve is shipped with standard extensions. Flushing Lines Flush the supply pipes completely and carefully by closing the body with the cover and its screws without the cartridge. Keep foreign matter OUT of the cartridge. - Screw the bushing onto the threaded tube. Slide the square tube into the bushing and drive it completely into the control spindle. - Make a cutting mark on the square tube flush with the bushing. Remove the square tube, cut it, and debur carefully. Replace the tube into the bushing and push it all the way into its recess. Page 2

Temperature Calibration Cartridge Removal Guide (Future reference ONLY) Let the water flow and bring this to a mean temperature by actuating the bushing (12). Note this temperature. Place the pointer assembly (6) on the bushing and position the red index opposite the graduation corresponding to the temperature noted. Tighten up the cap setscrew and fit the knob (4) again. When in use, if a water above 104 o F is desired, press the red index and turn the knob to the left. Maintenance Filter Cleaning If the cartridge is installed prior to flushing the lines you may inadvertantly clog the filters. Dirty filters may lead to a reduction in the flow rate. It is then necessary to clean them with a brush after removing the cartridge (2) from the body of the appliance (see "Cartridge Removal Guide). Brush the outsides of the filters ONLY. NEVER undo the brass screws, as doing so will VOID THE WARRANTY. D. Cleaning the Cartridge If the cartridge is installed prior to flushing the lines you may inadvertantly clog the filters. It will be necessary to remove the cartridge from the mixing valve - never take the cartridge apart or you will void all warranties. Simply soak the entire cartridge in plain vinegar for 1 to 3 hours and reinstall the valve. 90% of the time the valve will then work normally. See Operating Incidents for further details. Emptying in case of Frost When the appliance is exposed to freezing conditions it is ESSENTIAL to empty it: - either by turning on a tap at the bottom outlet - or by opening the cover (3) of the appliance. Page 3

GENERAL THERMOSTATIC INFORMATION FOR HOME OWNER Please read the complete Thermostatic instructions and cautions contained in this booklet before attempting to install the Thermostatic Valve System. Please be sure the Homeowner is provided the booklet for future reference for regular maintenance. FEATURES: The Eurotherm brand of Thermostatic valves have been in use worldwide for over fifty years. Complete serviceability from front of all units. Sizes vary from 1/2-3/4-1, 1-1/4, 1-1/2. and 2 for residential use. Cartridge is constructed using Bi-Metal Strip and Built-in Check Valves. The Bi-Metallic cartridge delivers the highest flow rate in the industry today. The Bi-Metallic cartridge has the fastest response time plus + (or) minus -1 second, and 1 Fahrenheit when fluctuation in supply pressure occurs. Extension kits are available through your dealer at an extra charge. Keep in mind that the distance the shower head or other exit is from the valve will depend on how fast you feel the instantaneous correction in the temperature. Uniform dials and push-button over-rides are interchangeable on all sizes of valves. Page 4

FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE DAMAGE OR IMPROPER OPERATION AND VOID THE WARRANTY. 1. Flush all rough-in piping thoroughly to remove sediment, flux and other debris. 2. Hot and cold inlets are clearly marked. DO NOT REVERSE CONNECTIONS, THE UNIT WILL NOT WORK CORRECTLY. 3. DO NOT USE DIRECT HEAT, OR ANY TORCH ON ROUGH VALVES. 4. If unit comes with a black or gray plastic outer ring -- read directions and be sure you keep above ring installed even after the trim is installed. 5. Minimum and maximum finished wall tolerances are clearly marked. (SEE EXPLODED VIEW OF VALVE) 6. It is extremely important that the rough mixing chamber be free of all debris before installation of the thermostatic cartridge. Read all instructions on boxes, valves and cartridges. 7. Under no circumstances should the thermostat cartridge be dismantled. Doing so will void any warranty and generally make the cartridge inoperable. MAINTENANCE The Bi-Metallic strip cartridge has two filter screens and a simple cleaning with a toothbrush will remove surface debris. Soaking the cartridge in a 50/50 solution of clear household vinegar and water will remove lime scale, and lime deposits caused from your water. Regular cleaning each year will extend the life of the cartridge. Never use a screwdriver on any thermostatic cartridge. Never take a thermostatic cartridge apart as you will damage this precise instrument. Call your dealer or the factory for answers to your questions. Page 5

Sigmatherm Technical Information The Sigmatherm Thermostatic Valve is designed to operate at water pressures as low as 14 psi and as high as 140 psi. If you have lower or higher pressure please consult the factory representative for suggestions or solutions. 1/2", 3/4", and 1" units are most commonly used for the deluxe shower, suite, or residential bath. These units are available in any of our handle and finish trims. For more details contact your sales representative. 1-1/4", 1-1/2", and 2" units do not come with decorative trim, as these valves are very large and require easy access to install and use. Call for further details. Important: All main lines must be the same size or larger than the supplied valve or the flow rates will not work. Therefore, if you use a 1-1/4" valve your water system should be based on a minimum 1-1/4" line--absolutely no smaller restriction should be allowed. Water Supply Sigmatherm valves can be supplied from any hot water production system, even by instantaneous domestic production, as far as the generator is capable of supplying very small quantities of hot water (about 0.8 gal/min). - Maximum working pressure 145 PSI - Minimum working pressure 14 PSI - Recommended working pressure 29 to 58 PSI - Maximum test pressure 224 PSI - Maximum hot water temperature 185 F Options 'Reverse' cartridges are available to correct improper installation (this special order is an extra charge and takes 12 weeks for delivery). Shut-Off Valves The mixer itself determines the proportions of hot and cold water required for the mixture. The mixer however regulates the temperature only and not the output; one shut-off valve (or more) must therefore be provided at the outlet(s) to control water flow. Non-Return Valves and Filters Non-return valves are incorporated into the cartridge. Eurotherm incorporates easily accessible stainless steel filters at the inlets of the cartridge. However, in order to access the cartridge, we recommend the installation of in-line plumber supplied shut-off valves close to the hot and cold inlets. Please remember the cartridge should be removed and cleaned annually for optimum useful life of the system. Page 6

NOTES: 1. THE SOLID LINE REPRESENTS THE ACTUAL OUTLINE OF THE TRIM PLATE 7-3/4 ROUND. 2. THE DASHED LINE REPRESENTS THE TYPICAL WALL CUTOUT FOR THERMOSTATIC VALVE INSTALLATION FOR 3/4" AND 1" SIZE VALVES. THE VALVE COMES WITH A WATER CONTROL RING! THIS MUD GUARD RING IS PART OF THE INSTALLED ROUGH VALVE. THIS GUARD MUST REMAIN WITH THE VALVE AND THE INSTALLED APPLICATION. THIS GUARD PREVENTS WATER FROM FLOWING INTO THE WALL WHEN THE COVER IS REMOVED TO SERVICE THE THERMOSTATIC CARTRIDGE. Page 7

OPERATING SOLUTION FOR SIGMATHERM THERMOSTATIC MIXERS USING 3/4", 1", 1-1/4", 1-1/2", AND 2" BI-METAL CARTRIDGES In the event of an operating problem with a Sigma thermostatic mixer, review the following information. Make sure hot and cold inlets are correctly connected to the marked hot and cold side of the mixer. Be sure there is sufficient water pressure and that you have calibrated the mixer valve correctly. Check whether the screens are clean of debris. The main operating problems, their causes and remedies are described below. If the problem is caused by the mixer, return the replaceable mechanism or the complete mixer (industrial models) to the factory. OPERATING DEFECTS REASON REMEDIES cf verso 1 - When first using a new appliance, only - The water inlets are reversed. 1 hot or cold water is delivered. - The bimetal strip is not properly centered (*), 5 - The distributing valve is not free (*). 7 2 - The mixed water temperature follows the - The control system is incorrectly calibrated 2 position of the graduated regulator but with a 6 certain delay. 3 - The appliance does not deliver mixed water or 3 only when the regulator is turned up all the way. - One of the water inlets doesn t work. 4 - The mixed water is delivered in spurts and the flow rate is low except at one temperature or the - One of the water supplies doesn t provide 4 limited temperatures. sufficient water. The bimetal strip is not properly centered (*), 5 - From time to time the appliance only delivers - The distributing valve is not free (*), 5 hot or cold water. - Series 7100-7200 ou x 222 : The slide valve is 7 blocked. 8 6 - The water is always supplied at the same - The bimetal strip does not move the distributing 7 temperature hot or cold. valve : } (*) a) Because the distributing valve is not free (*). b) Because the regulating screw does not act on 10 the mechanism (*). - Series 7100-7200 ou x 222 : The slide valve is 8 blocked. 7 - The temperature is irregular, especially when - There are foreign particles beneath the flow rates are low. membrane (*). - The membrane is damaged (*). 8 - Series 7100-7200 ou x 222 : The slide valve is blocked. 8 - Insufficient mixed water is supplied. - Pressure is too low. 3 - One of the water supplies is insufficient. 9 9 - The different water supplies intercommunicate 6 in the mixer. (*) On all models except on the Series x 222. 7100, 7200, 9100, 8100, 8140. Page 8

FAUCET & COATINGS CORPORATION LIMITED PRODUCT WARRANTY Product/Finish Warranty: warrants that products are free from defects in materials and workmanship for five (5) years from date of invoice. In addition, our Finish Warranty provides limited LIFETIME coverage for Chrome & PVD finishes, five (5) years for Omega powder coated finishes & Polished Gold. Living finishes are warranted for workmanship only. If any material proves to be defective after inspection by our company, it will be repaired or replaced at our discretion at no charge. However, no claims for labor, shipping costs, or consequential damages will be accepted. What we will do: We will restore any product whose finish proves to be defective back to its original finish at no charge during the appropriate warranty period stated above. Proof of purchase must be provided. After the warranty period, American Faucet and Coatings Corporation will refinish any of its faucets at the prevailing appropriate charge. What you must do: The faucets must be properly installed according to our instructions and specifications & are for residential use only. The faucets cannot be altered in any way. You must maintain and clean the faucets in accordance with the instructions provided with the product. You must use the faucet(s) for residential use only. How to obtain service: Send your name, address, and telephone number along with a statement describing the nature of the problem and your paid sales slip or other proof of purchase to: 3280 Corporate View Vista, CA 92081 We will then contact you and take appropriate action. Do not send us any part(s) of your faucet(s) or its various connecting hoses unless we have contacted you and have sent you an approved RGA form. All transportation charges for returned goods must be paid by the customer. What is not covered: This warranty does not cover the crystal/glass, or porcelain products of any faucet or the drain assembly or aerator on other than the Chrome or PVD finishes. This warranty also does not cover damage caused by accident, alterations, misuse, abuse, normal wear and tear, lime deposits, direct exposure to salty air or corrosive materials, or the color change that takes place with the passage of time, or use in any manner contrary to American Faucet and Coatings Corporation's printed instructions. In the case of in-the-wall installations American Faucet and Coatings Corp. will assume no liability if there is no access. In no event will we be liable for labor of any kind, incidental or consequential damages. This warranty is extended in lieu of all other expressed or implied warranties, whether oral or written. Many installation compounds are harmful to brass and metal finishes. The use of any lead-based or acidic curing adhesive, silicone, mastic, or plumber's putty on or near our finished products will void the finish warranty. Use only sealants which are neutral curing and are not reactive with metal and brass finishes. reserves the right to change, modify or alter its products as deemed necessary. This warranty supersedes any other American Faucet & Coatings Corporation warranties, whether oral or written. Unless otherwise contrary to state law governing the purchase, American Faucet and Coatings Corporation's liability will not exceed the wholesale price for the American Faucet and Coatings Corporation product considered defective. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow exclusion of incidental or consequential damages, so the above limitation may not apply to you. LIFETIME WARRANTY ON 1/4 TURN CERAMIC DISC CARTRIDGE Should the ceramic disc cartridge in your faucet ever fail, will replace the failed part free of charge to the original purchaser of the product. Your cost will be a $9.95 handling and mailing charge. Labor not included. When ordering replacements, denote for widespread or centerset lavatory, Roman Tub, or other. Include age of faucet. (This does not include thermostatic, pressure balance, or diverter cartridges.) CONSUMER WARNING CALIFORNIA PROPOSTION 65 WARNING Among other chemicals known to cause harm, this faucet contains lead, a chemical known to the State of California to cause birth defects or other reproductive harm. All faucets and products made of leaded brass alloys, even those that comply with U.S. Environmental Protection Agency regulations, contribute small amounts of lead to water that is allowed to stand in contact with the brass. This faucet complies with all E.P.A. regulations regarding the amount of lead used in plumbing brass and solder. The amount of lead contributed by any faucet is highest when the faucet is new. The following steps will reduce potential for exposure to lead from faucets and other parts of the plumbing system: Always run the water for a few seconds prior to use for drinking or cooking. Use only cold water for drinking or cooking. If you wish to flush the entire plumbing system of water that has been standing in the pipes or other fittings, run the cold water until the temperature of the water drops, indicating water coming from the outside main. If you are concerned about lead in your water, have your water tested. Page 9