Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Similar documents
Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 7000 Fixed gas detector

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger X-am 2500 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detector

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger X-am 2500 Multi-Gas Detector

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

ALTAIR 5X Multigas Detector

Monitores Personales. Personal Monitor

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

D D D Dräger Gas Detection ST Dräger: Technology for Life

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

micropac. Personal Gas Detection Instruments

ALTAIR 5X Multigas Detector Product Specification

PROTÉGÉ ZM SINGLE GAS MONITOR

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

Polytector III G999 for Ex zone 0

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Pac 8000 Single-Gas Detection Device

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

GasAlertMicroClip X3 Specifications

VENTIS PRO SERIES. Product Guide

Dräger Pac 8500 Single-Gas Detector

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-zone 5500 Area Monitoring

Dräger Pac 6000 Single-Gas Detector

1.1 Definitions of alert icons. For your safety

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

G-TECTA TM. Portable Gas Detection Instruments

DRAEGER GAS DETECTION PIONEERING SOLUTIONS

Dräger Pac 7000 Single-Gas Detection Device

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger X-am 2500 (MQG 0011) Technical Manual

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger REGARD -1 Control System

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Sieger Apex. Flexibility that meets your requirements

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger PointGard 2100 Detection of toxic gases and vapours

MSA Portable Gas Detection

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Pac 6000 Single-Gas Detection Device

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

An easy and flexible way to do gas detection.

OLC(T) 100 FIXED GAS DETECTOR

Dräger Polytron Pulsar 2 Open Path Gas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Pac 8500 Single-Gas Detection Device

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Pac 3500 Single-Gas Detection Device

Neotronics Impact & Impact Pro

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

Dräger Polytron 7000 Detection of toxic gases and oxygen

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger X-zone 5500 Area Monitoring

IMR IX176 Portable Gas Detector User Manual

Hygrometer / Air Quality Meter

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

CO warning instruments and gas spillage detectors

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

Catalytic Bead DrägerSensors for Fixed Gas Detectors

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

GAS DETECTION & RESPIRATORY PROTECTION

For the Safety of Your

PERSONAL COMBUSTIBLE GAS DETECTOR

ALTAIR 5X Multigas Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Transmitters/Sensors. OLCT Series

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

Dräger X-zone 5500 Multi-Gas Detection Device

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Transcription:

DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger X-am 7000 ST-2660-2003 Dräger X-am 7000 is the innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The Dräger X-am 7000 can be equipped with three electrochemical, and two catalytic bead, infrared or photoionisation sensors. It is the ideal companion in a great number of applications where reliable monitoring of Oxygen, toxic and combustibles gases and vapors in the ambient air is necessary. ST-65-2006 Modular, rugged and waterproof. Flexibility through sensor variety The extensive portfolio of over 25 different DrägerSensors allows the detection of more than 100 gases and vapors. The measuring range of the EC, Cat-Ex, IR and PID sensors can be changed to another gas within a list of gases by a push of a button without the necessity of re-calibrating. In this way the instrument can be adapted easily to various applications. DrägerSensors are renowned for fast response, minor cross sensitivities, high accuracy and long life. Intelligent and interchangeable sensors Each sensor is recognized automatically by the instrument. All sensors are pre-calibrated, and a reconfiguration of the Dräger X-am 7000 is done by simply changing a sensor. I.e. no additional service or maintenance is necessary. Intuitive software functions The software menu of the Dräger X-am 7000 was designed in partnership with our customers making it simple and easy to use. Functions such as TWA and STEL values, as well as functions, like peak hold can be viewed or switched on quickly and with minimal training. Leak search functionality Searching a leak has been revolutionized by the Dräger X-am 7000. In the trackingmode, the instrument generates an increasing or decreasing rate of beeps, depending on the gas concentration detected. Rugged and waterproof Additional to the built-in dust and splash water protection, the Dräger X-am 7000 can be submersed without damage. A specially designed rubber-boot protects the instrument against damage from a drop of 1.5 m (5 ft.). Built for longevity The completely new design of the rechargeable battery block with intelligent charging management guarantees full functionality of the instrument over a period of up to 20 hours (depending on the battery type). An alcaline battery pack is also available. The DrägerSensors used in the Dräger X-am 7000 have a typical life of over 5 years. If, in time, an exchange is necessary, the modular approach of the instrument allows this in a few simple steps.

DRÄGER X-AM 7000 Multiple Warning Systems Alarm conditions can not be ignored because of the sound of an extremely loud multi-tone horn. In addition the visual alarm can be seen through 360 ensuring it attracts the users attention. By generating a life-signal every six seconds the Dräger X-am 7000 confirms it is functioning normally. Information at a glance The large graphic Display and the alarmauto-zoom function guarantee easy recognition of the values and symbols displayed for immediate judgement about the situation or hazards. All information is provided in plain text. Data management A built-in data memory logs up to 3000 sets of values that is data logging of 100 hours when recording one set per minute. The data can be transmitted and evaluated on a PC using an infrared interface together with the Dräger GasVision software package. Strong Built-in Pump The built-in high power pump allows to sample gas through an up to 45 m/150 ft. long tube. The operation of the pump is continuously monitored, and the instrument will generate an alarm if the flow is too low. DrägerSensors Equipped with 3 electrochemical and 2 catalytic bead, infrared sensors or photoionisation sensors Alarm functions 360 -all around visible and > 100 db multitone audible alarm Large display Clearly structured, scratch resistant display with information in plain text ST-67-2006 Robust enclosure Rugged, waterproof with standard rubber-boot ORDER INFORMATION Dräger X-am 7000, basic unit with rubber-boot, carrying strap, 83 17 400 calibration adapter, water- and dustfilter In order to get a fully operational unit a power pack and up to 5 sensors have to be ordered. And optional, a built-in pump or a datalogger can be ordered. Power supply units NiMH-power pack 4,8 V / 3,0 Ah 83 17 408 NiMH-power pack 4,8 V / 6,0 Ah 83 17 454 Alkaline-power pack 83 17 550 Instrument options Upgrade pump, incl. pump adapter 83 17 804 Upgrade Datalogger 83 18 249

ORDER INFORMATION Chargers Charging module 83 16 487 Power supply for up to eight charging modules 83 15 805 Power supply for one charging module 83 15 635 Wall power supply 83 16 994 Adapter for vehicles 83 12 645 Car mounting kit 83 18 169 Other accessories Pump adapter 83 17 639 Sensor extension cabel for calibration with vapors 83 17 970 Leather carrying case 83 17 683 Nylon carrying case 83 17 684 Carrying strap (carrying belt with plate) 83 16 878 Waist Belt (to adapt to carrying frame) 83 17 682 Carrying clip 83 17 771 Dräger GasVision Software 83 14 034 Dräger CC-Vision Software 64 08 515 Sensors for Dräger X-am 7000 IR Ex 0 to100 %LEL 68 10 460 0 to100 Vol.-% CH 4 IR CO 2 0 to 5 Vol.-% 68 10 590 IR CO 2 HC 0 to 100 Vol.-% 68 10 599 Cat-Ex Sensor 0 to 100 % LEL 68 10 710 Cat-Ex Sensor HC 0 to 100 % LEL 68 10 410 0 to 100 Vol.-% CH 4 PID Sensor 0 to 2000 ppm 83 19 100 DrägerSensors XS R CO 0 to 2000 ppm 68 10 258 H 2 S 0 to 100 ppm 68 10 260 O 2 0 to 25 Vol.-% 68 10 262 DrägerSensors XS EC CO 0 to 2000 ppm 68 09 105 H 2 S 100 0 to 100 ppm 68 09 110 H 2 S HC 0 to 1000 ppm 68 09 180 O 2 LS 0 to 25 Vol.-% 68 09 130 O 2 100 0 to 100 Vol.-% 68 09 550 NO 0 to 200 ppm 68 09 125 SO 2 0 to 100 ppm 68 09 160 NO 2 0 to 50 ppm 68 09 155 COCl 2 0 to 3 ppm 68 08 582 NH 3 0 to 200 ppm 68 09 145 HCN 0 to 50 ppm 68 09 150 Cl 2 0 to 20 ppm 68 09 165 Hydrides 0 to 20 ppm 68 09 135 CO 2 0 to 5 Vol.-% 68 09 175 OV 0 to 200 ppm 68 09 115 OV-A 0 to 100 ppm 68 09 522 Odorant 0 to 40 ppm 68 09 200 PH 3 HC 0 to 1000 ppm 68 09 535 Amines 0 to 100 ppm 68 09 545 CO HC 0 to 1000 ppm 68 09 120 H 2 0 to 2000 ppm 68 09 185 DrägerSensors XS 2 CO 0 to 2000 ppm 68 10 365 H 2 S 0 to 100 ppm 68 10 370 O 2 0 to 25 Vol.-% 68 10 375 ST-2642-2003 Leaksearch made easy by generating tracking sound. ST-2770-2003 High performance pump for professional confined space entry.

TECHNICAL DATA Type Produktname Multi gas measuring and warning device for up to 5 measurement channels: electrochemical sensors (for toxic gases and Oxygen) and 2 catalytic sensors respectively infrared sensors (for combustible gases and vapors or Carbon Dioxide) or photoionisation sensors Size (w x h x d. approx.) 150 x 140 x 75 mm, 5.9 x 5.6 x 3 Weight (approx.) Instrument 600 g, 21 oz. Rechargeable battery 490 g, 17 oz. (3.0 Ah); 730 g, 26 oz. (6.0 Ah) Ambient conditions Temperature - 20 to + 55 C, intermittent - 40 to + 60 C, - 5 to + 105 F, intermittent - 40 to + 130 F Pressure 700 to 1300 hpa, 20.7 to 38.4 inch Hg Humidity 10 to 95 %RH Enclosure rating IP 67 Typical battery life NiMH (4.8 V / 3.0 Ah) > 9 hours NiMH (4.8 V / 6.0 Ah) > 20 hours Alkaline > 20 hours Audible alarm > 100 db (A) at a distance of 30 cm; 1ft. Charging time 3.5 to 7 hours, depending on battery type Pump mode maximum length of tubing 45 m, 150 ft. Approvals ATEX II 2G EEx ia d IIC T4; - 20 Ta + 60 C I M2 EEx ia d I EC-Type Examination Certificate BVS 03 ATEX E 371 X MED Marine Equipment Directive 96/98/EC UL Class I, Div 1, Group A, B, C, D; Temp Code T4 CSA Class I, Div 1, Group A, B, C, D; Temp Code T4 IECEx Ex ia d I/IIC T4; - 20 Ta + 60 C CE-mark electromagnetic compatibility (directive 89/336/EEC) 90 44 772 PI 026 CR-PR-ED Corporate Communications ST Printed in Germany chlorinefree ecological Subject to modifications!

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.