R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D

Similar documents
Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Exhibition Hall 1. Fachprogramm. Technical Programme

Use of transcritical CO 2 in industrial applications

investment in R&D, the commitment to - name.

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

CO 2 Ice Bank Answer to the next requirements

DTI Kenneth Bank Madsen Global Application Expert Food Retail

Environmentally friendly refrigeration systems for industrial use

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

Natural Refrigerants.

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

PACKAGED REFRIGERATION EQUIPMENT

From the Field to the Supermarket

FACT SHEET 6 Transport Refrigeration

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Safe Handling of Ammonia & Reporting Leaks. Andrew Keeley, Senior Project Professional

Mechanical Systems Mechanical Systems

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Nature can make it I N N O VAT O R S I N R E F R I G E R AT I O N A N D C O O L I N G T E C H N O L O G I E S

Green economy with natural refrigerants

Chapter 1 Preface & General

Energy Efficiency Considerations in Refrigeration Systems

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

ECO-FRIENDLY STORES Commitment and Efficiency

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Make value of the waste energy from your cooling units and heat water for free

Natural refrigerant trends in EU, Japan & North America

Fabrication of Hot and Cold Water Dispenser

This presentation is posted for public use. ACEEE does not endorse any product or service.

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Guidance for Stationary Refrigeration & Air-Conditioning

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

ABSTRACT. 2 CanmetENERGY

Transcritical CO2 Bottle Cooler Development

Winter sports fun all year round, thanks to natural refrigerants

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

HFCs or the Old Refrigerants - what is the best Choice?

FACT SHEET 9 Large Air-Conditioning (air-to-air)

DK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS

CO 2 transcritical FTE System Full Transcritical Efficiency

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Air-cooled Screw Chillers Model RTAF G Process

Natural Refrigerant Market Trends

48th International HVAC&R Congress Belgrade 2017

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

Process glycol chillers

Product Offering for 2017

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Ammonia. Background on ammonia as a refrigerant

Natural refrigerants - naturally efficient

Air Conditioning and process cooling Energy Components at a Glance

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

Welkom. Optimalisatie CO2 systemen m.b.v. ejecteur

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Chapter 2. Alternatives to HCFCs and their Characteristics

Thermodynamics II Chapter 5 Refrigeration

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

SUBCRITICAL & TRANSCRITICAL SYSTEMS

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

COMPANY Presentation Focus on SANDEN Environmental Solutions

COMPACT CO 2 /NH 3 REFRIGERATION UNIT FOR THE COLD STORAGE

BLAST FREEZING ROOMS

EN aquatech.piovan.com

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

TEKO services. At a glance.

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Adaptable in Adelaide

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

CO2 TRANSCRITICAL BOOSTER SYSTEMS

ISSN Vol.08,Issue.21, November-2016, Pages:

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

COOL PLUS KENYA (K) LIMITED

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

2. CURRICULUM. Sl. No.

An Efficient Cold Store Facility

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Simply fresh today and tomorrow

Refrigerants & Cooling in renovation buildings

Heat pump and energy recovery systems

Rapid Freeze F L A K E I C E E Q U I P M E N T

Save energy and protect the environment

Brazed Plate Heat Exchanger for CO Applications

Emerging Refrigeration Technologies

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

Thermodynamics I. Refrigeration and Heat Pump Cycles

Industrial Heat Pumped Hot Water

Refrigeration Systems Handbook

recooler HP EQKR HEAT PUMP

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Transcription:

R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D TECHNICAL UNIVERSITY OF CIVIL ENGINEERING BUCHAREST The Faculty of Building Services Thermodynamics Heat and Mass Transfer President ROMANIAN GENERAL ASSOCIATION OF REFRIGERATION Past President ASHRAE DANUBE CHAPTER BELGRADE December 2015

INTRODUCTION - TEWI - GWP R134 =1430 GWP NH3 = 0 ODP NH3 = 0 3 500 3 260 3 000 2 500 2 000 1 500 1 300 1 000 500 0 R404A R134a R744 (CO2) 1

AMMONIA INDUSTRIAL REFRIGERATION IN ROMANIA IN THE LAST YEARS Fruites, 2% Vegetables, 2% Poultry Farms, 2% Food Industry Skate ring, 1% Diary, 2% Slaugther house, 5% Chemicals, 1% Drinks, 2% Warehouse, 3% Storage, 80%

Industrial Rrefrigeration - Logistics Centers - Meat & poultry - Slaughterhouses - Meat storage and processing - Dairy industry - Breweries, Beverages - Breweries - Soft drinks - Fish processing - Cold Store - Ice rinks

COMPRESSORS USED IN ROMANIAN AMMONIA REFRIGERATION PLANTS IN THE LAST YEARS Ammonia Compressors 90% 80% 80% 70% 60% 50% 40% 30% 20% 15% 10% 5% 0% reciprocating 2 stage reciprocating 1 stage screw

CONDENSERS USED IN ROMANIAN AMMONIA REFRIGERATION PLANTS IN THE LAST YEARS Condensers 100% 95% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 5% Water coold Evaporative

EVAPORATORS USED IN ROMANIAN AMMONIA REFRIGERATION PLANTS IN THE LAST YEARS Ammonia Evaporators 45% 40% 40% 35% 30% 30% 25% 20% 15% 15% 15% 10% 5% 0% Fin space 4 mm Fin space 7 mm Fin space 10 mm Fin space 12 mm

Logistic & distribution centers INNOVATION: Danone Logistics, Voluntari, Romania The refrigeration plant for the logistics center of Danone Romania Natural refrigerant, ammonia The system ensure minimum energy consumption including defrost optimization Innovation: compact manifold station ICF Danfoss - quick execution + maximum safety due to the reduction in welding

References Food Processing R717 Customer: Leading food processing company, Romania Modernization and expansion of existing plant with high GWP refrigerant R404A One of the most modern refrigeration plant in Romania Natural refrigerant, ammonia For efficient operation of screw compressors, condenser fans, ammonia and glycol pumps are driven by frequency converters Operating costs optimization via: heat recovery discharge from the oil cooling floating condensing pressure around the plant

Logistics & distribution centers references EXPERTISE: Leading Retail Logistic Center, Romania The most advanced refrigeration plant in Romania for a leading retail group Very high quality standards Natural refrigerant ammonia Heat recovery system in two-stages (one from discharge side, second from oil cooling) Automatic oil recovery system and all major equipment controlled by Variable Speed Drives

ROMANIAN SUPERMARKETS WORKING WITH R134A / R744 (CO2) CASCADE SYSTEM CITY REFRIGERATION CAPACITY [KW] Buzau 65 10 P.Neamt 60 10 FREEZING CAPACITY [KW] Trans critic new commercial applications! Lugoj 80 10 Campina 115 15 Rm.Valcea 80 15 Moinesti 45 10 Brasov 60 10 Tg.Mures 60 10 Mioveni 55 10 Slatina 55 10

Supermarket Hybrid R744/R134a references EFFICIENCY/ENVIRONMENT: Carrefour Buzau, Romania Carrefour Express Buzau, August 2013: Frigotehnica completed the first project with new hybrid technology R744/R134A Efficient and environmentally friendly refrigeration system Heating of the premises with heat recovered from refrigeration circuit and using electric rolling valves

Hypermarket - Transcritical R744 references FIRST CO2 INSTALLATION: Carrefour Galati, Romania the first TRANSCRITICAL CO2 REFRIGERATION SYSTEM IN ROMANIA Complete refrigeration plant Heat recovery: preparation of hot water and for heating of the hypermarket Full compliance with client requirements Romanian engineering, delivery and installation Operation optimized: CO2 sub cooling and parallel compression Installation by our certified technicians.

Hypermarket Transcritical R744 references FULL CO2 INSTALLATIONS: Carrefour Brasov, Romania Carrefour Vulcan, Bucuresti, Romania Carrefour Targu Jiu, Romania, MegamMall Brasov: complete remodeling of an old refrigerating plant (R404A), and was performed while the hypermarket operated in normal conditions Carrefour Vulcan and Targu Jiu: completely new trans-critical R744

TRAINING of PERSONNEL INVOLVED IN THE FIELD OF REFRIGERATION AND AIR- CONDITIONING ACCORDING TO THE EU PROJECTS AND REGULATIONS

CONCLUSIONS AND FUTURE WORK Demonstrating a strong commitment to protect the environment through the use of natural refrigerants and most advanced refrigeration solutions, Romania decided to use green technology for CO2 cascade and trans critic new commercial applications; CO2, Ammonia as ecological refrigerant alternatives; EU refrigeration and air conditioning legislation implementation in Romania.

SUCCESS! Thank you for your attention! gratiela.tarlea@gmail.com www.agfro.ro