Pivot Stove Hydronic Installation Guide

Similar documents
ADVANCE ECB ELECTRIC COMBINATION BOILER

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313

Efficiency Maximiser for Solid Fuel Central Heating

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

Samsung EHS Heat Pump Test

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Hydraulic Installation

THERMAL STORE MAINS PRESSURE SYSTEM

Link-Up. Solid Fuel Association Guide to Central Heating.

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Assessment Schedule - TS.6

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

INSTALLATION & TECHNICAL MANUAL

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

INSTALLATION INSTRUCTIONS ONE LARGE ZONE

CalMag Heating Pack Installation Instructions

THERMAL STORE MAINS PRESSURE SYSTEM

Tuzio Milano Towel Warmer

Metering systems 0548EN April 2014

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Wood Boiler Plumbing Schematics

ADVANCE ELECTRIC THERMAL STORE

CPC-150-ABIAB. Important Installation Notes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Components for solar heating systems

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation Instructions Solar Controller Kit (Part Number AQ )

High Output Boiler Systems

WATER BOILER METOS MARINE WKI MG MW,

Installation, Operating and Servicing Instructions

VSL II QUICK START GUIDE

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Hot Chocolate Dispenser

Installation, Operating and Servicing Instructions

Columbia Boiler Company

Installation and Servicing Instructions. Alpha FlowSmart

Schuco SS-TC/SC Cylinders

DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

CPC-150-ANA. 150 litres, 535mm x 1300mm high. Pandora Heat Bank. 100kW Plate Heat Exchanger with 22mm Thermostatic Mixing Valve.

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

INSTALLATION INSTRUCTIONS

INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

R557R EN January 2012

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Hydraulic Separation Moving Beyond Priamry / Secondary Piping...

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Demand Duo Principle of Operation:

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

BMW E36 Thermostat Removal And Coolant Flush

Gas, oil and heating products. The main line products at competitive prices with even better prices on our VALUE range.

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

SEALED THERMAL STORE

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION DVI/6000. Version presented DVI/6000 PIGNAT S.A.S. Subject to technical modifications

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Mercury Mixing Kit (Code: ME1053)

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

CalMag Filter Installation Instructions

CENTRA-COIL QUALITY HOT WATER SERVICE

SmartRad Planning Manual

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Allcan TM Installation Manual

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

Water Piping and Pumps

BOILER APPLICATION GUIDE for:

Crown Boiler Company

Unvented Direct & Indirect Hot Water Cylinders (400L L)

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

warm water underfloor heating installation manual v4b-aug 08 Nu-Heat design innovation expertise service

DIVISION 15 MECHANICAL

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Slant Fin Corp. Installation and Operation Instructions

HVAC No. MFG Part No. Description Size Price

Plumber Level 3 Rev. May 2011

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

A student investigated how much energy from the Sun was incident on the Earth s surface at her location.

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

Transcription:

Pivot Stove Hydronic Installation Guide

Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header tank. Spill Tray Both formats Header Tank & Hot Water Service, spill tray is a mandatory requirement. Pipe Flow & Return From the appliance, YOU CAN NOT RESTRICT the pipe size leaving the appliance. The flow & return pipe work should always be installed on a rise to allow the water to thermosiphon Note that on the flow line (no pumps or valves) that will isolate or restrict the flow to be installed. Minimum 1 copper to be used between the header tank and appliance. Flow Line going into the header tank is to be submerged below the water line to avoid oxidization if boiling occurs. Recommended to lag copper with Armaflex Connection To The Appliance The connection between the Appliance and copper should always be made with Hemp & Paste Water Level In Header Tank The water level is recommended in the header tank to be filled to 40% capacity. Require ½ cold water supply. Flow to be 40mm below water level Flow line 25mm min used Drip tray required Cold inlet feed required Drain point required Header tank must be 40% full Header Tank

Solar / Radiator Set Up Stove Inlet 1 Stove outlet 2 Domestic Water Outlet 4 5 Overflow Domestic Water Inlet 3 Right Angle Flow Valve Right Angle Return Lock Shield Notes: 1. Flow to enter in side of tank, on rise at all times. 2. Return line to be installed below tank, on gradient at all times 3. Domestic cold water inlet to feed coil. 4. Domestic hot water lead to house. 5. Overflow vent pipe to be drained off the roof externally in copper. 6. Field pump thermostat to activate on at 65 degrees. 7. Field pump to be 8. Field pump to be installed above BCU and electricals, are to be facing upwards. 9 & 10. Flow and return manifolds to be installed horizontally at all times. 11. Flow and return manifolds to be installed horizontally at all times. 12. Hot Water System flow on top and return on bottom. Check valve 13 Field Pump 10 Radiator Radiator 13 BCU on BCU off 6 7 Manifolds 11 Pivot Stove and Heating Hydronic Manual Pump 8 12 Thermostat Wiring Project Number N/A Date 24/9/16 Drawn By Pivot Hydronics Checked By Pivot Hydronics A- 3.00 6 7 8 REV - Sheet Number 3 *NOT TO SCALE* Hydronic Systems

Notes: Gasification System Check valve 3 1 Header Tank Feed Point 2 6 Right Angle Flow Valve Right Angle Return Lock Shield 1. Flow to enter in side of tank. 2. Return line to be installed below tank 3. Domestic cold water inlet to lead coil. 4. Field pump to be wired directly into gasogen boiler to be activated. *see page...* 5. Re-circulation pump to be wired directly to gasogen to be activated. *see page... * 6. Buffer Tank 400ltr. 7. Immersion thermostat to activate field pump on at 70 degrees. 8. Secondary field pump to service hydronics. 9. Thermostat to call pump off when return temperature is reached at 45 degrees. 10. Expansion tank & auto fill system kit to be installed on return line. 11. Manifold arrangement. Field Pump 4 7 8 11 Field Pump 5 9 Pivot Stove and Heating Hydronic Manual Thermostat Wiring 7 9 10 Project Number N/A Date 24/9/16 Drawn By Pivot Hydronics Checked By REV - Pivot Hydronics A- 5.00 Sheet Number 5 *NOT TO SCALE* Hydronic Systems

Installation of BCU Boiler Control Unit Installation of BCU, Pump and check valve When installing the BCU, recommended 300mm (minimum) higher than the appliance to allow for thermosiphoning. Ensure that pump is fitted with 2 sensor tee s and 2 thermostat s: One thermostat to trigger the pump to turn ON at 15 C. The other thermostat to turn the pump OFF at 55 C allowing a consistent circulation between the appliance and the BCU. Installation of Pump in Field Note the field pump is recommended to branch off on the flow line above the location of the sensor tee and BCU, yet below the swing check valve. Pump is to be fitted with isolation ball valve unions to allow the pump to be isolated for servicing and general maintenance. The correct installation of the pump is to fit the electrical board in a position that it is not facing below the flow line. Adjustments on ensuring this is achieved can be found in the operational manual of the pump. To be installed horizontally. As part of the commissioning, ensure that the pump is correctly bled Refer to the operation manual. Check Valve Install check valve 200mm below header tank on flow line Ensure that the check valve is after the pump has been teed off

Installation of Thermostat, Sensor Tee and Check Valve Sensor Tee Ensure that the Sensor Tee is fitted on the flow line between the appliance and the header tank. This is to be fitted as close to appliance to allow an accurate gauge of the water temperature. Follow wiring diagram. This should be fitted with Hemp & Paste Thermostat - Refer to wiring diagram The thermostat is to be connected to the pump the pump activated to turn on when the set temperature is reached. Ensure that pump is fitted with 2 sensor tee s and 2 thermostat s: One thermostat to trigger the pump to turn ON at 15 C. The other thermostat to turn the pump OFF at 55 C allowing a consistent circulation between the appliance and the BCU. BCU is to be fitted with a thermostat that is activated to come on at 15 C. Follow wiring diagram. The secondary pump in the field, which is branched off the flow line, is ideally set to 65 C to begin with this can be increased or lowered depending on the application. The goal is to pull the water off before boil point in the header tank. Check Valve Check valve to be installed above pump on the flow line, minimum 200mm below header tank. This will reduce thermosiphoning, ensuring heat is pulled off the boiler and not the header tank.

BCU Recommended Set Up 1 2 3A 2 1 BCU WAX SETTING Set Adjustment 1/2 way in BCU PUMP SETTING Active Pump (2) Earth Pump Pump Active Pump (3) Earth Pump Pump 3A NEUTRAL NEUTRAL Active Thermostat wired to turn off at 55o degrees # See wiring diagram supplied with thermostat Active GPO (1) Earth GPO GPO RECOMMENDED SET UP 3B Active Thermostat wired to come on at 20 o degrees # See wiring diagram supplied with thermostat Active GPO (1) Earth GPO GPO Notes: 1. Allen key to be dialled all the way in. And one an a half turns outwards, this is the correct mix of cold and hot water. 2. Pump setting to be set to number 1 towards the left hand side on the constant setting, as indicated. 3A. Siemens thermostat to activate the BCU to come on at 20 degrees, this is wired into terminal 3 and 1. 3B. Siemens thermostat to be wired to turn the pump of one to temperatures reach 55o. This is wired to terminal 2 &2. 4. Sensor Tee s one to be installed below the BCU on the flow line. Two thermostats required for the BCU. * It is recommended to operate the BCU with two thermostats, one activating the pump at a lower temperature and to shut off at a higher temperature. * Typical install requires only one thermostat to shut off at a higher temperature. 4 4 WAY TEE Supplied by Pivot Pivot Stove and Heating Hydronic Manual Project Number N/A Date 24/9/16 Copper probes 3B Reducing Caps Supplied by Pivot Drawn By Checked By Pivot Hydronics 5 Pivot Hydronics A- 8.00 Reducer Cap Supplied By Pivot Sensor well Supplied by plumber REV - Sheet Number 8 *NOT TO SCALE* Sensor Tee Provision For Field Pump Hydronic Systems

BCU Basic Set Up 2 1 2 1 BCU WAX SETTING Set Adjustment 1/2 way in BCU PUMP SETTING 3 Active Pump (3) Active Thermostat wired to come on at 20 o degrees # See wiring diagram supplied with thermostat Active GPO (1) Notes: 1. Allen key to be dialled all the way in. And one an a half turns outwards, this is the correct mix of cold and hot water. 2. Pump setting to be set to number 1 towards the left hand side on the constant setting, as indicated. 3. Siemens thermostat to be wired to turn the pump of one to temperatures reach 55o. This is wired to terminal 2 &2. 4. Sensor Tee s one to be installed below the BCU on the flow line. Two thermostats required for the BCU. Earth Pump Earth GPO 3 Pump NEUTRAL GPO * It is recommended to operate the BCU with two thermostats, one activating the pump at a lower temperature and to shut off at a higher temperature. * Typical install requires only one thermostat to shut off at a higher temperature. 4 4 WAY TEE Supplied by Pivot Pivot Stove and Heating Hydronic Manual Reducing Caps Supplied by Pivot Project Number N/A Date 24/9/16 Copper probes Reducer Cap Supplied By Pivot Sensor well Supplied by plumber Drawn By Checked By Pivot Hydronics 5 Pivot Hydronics A- 7.00 REV - Sheet Number 7 Sensor Tee Provision For Field Pump *NOT TO SCALE* Hydronic Systems

Radiators Manifold & Pipe Radiators When installing the radiators the recommended size for noggins is 90mm or 40mm. This will ensure that you have suitable fixings for your brackets. Bracket locations refer to manufactures design The flow line is recommended fitted on the left hand side of the radiator, at the lowest fixing. Fixing Kit When fitting off the radiator, ensure that the lock shield is fitted on the return line (RHS) and is fully opened (turned anticlockwise). When fitting off the radiators, ensure the right angle valve fitted on the (LHS) and is fully open to the desired temperature. Optional Thermostatic heads are to be fitted on the (LHS) in replacement for the cap on the valve. Manifold / Pipe Between the appliance and the manifold, this should be all installed in copper. From the manifold onwards 16mm multilayered insulated pexal pipe should be installed to the radiators. Ensure the flow line runs to the top ports and the return line runs the lower ports. The auto bleed should be fitted on RHS flow ports Drain point fitted to the return port on the LHS The manifold is recommended to be fitted horizontally and after the pump in the field. The distance from the manifold to the secondary pump in the field is recommended to be no more than 15mm away to avoid heat loss.

In-slab Mixing kit / Pipe / Manifold Mixing Kit (reference 2) All In-Slab designs should incorporate a BCU Mixing kit to be fitted with Hemp & Paste Thermostat fitted on the mixing kit is recommended at maximum to be set at 50 C This should be fitted after the secondary pump in the field yet as close as possible to the manifold servicing the In-Slab. Pipe The pipe used for the In-Slab circuit is recommended to be 16mm oxygen barrier pipe work. No more than 100m of pipe per circuit is recommended. This is broken down to a maximum of 50m on the flow and 50m return lines. No joins or bends to be fitted at any point in the circuit. This can be installed either tied to the mesh or to the insulated panel (Depending on the set up, refer to manufactures specification)

In-slab / Radiator Set Up Check valve 2 Field Pump 8 1 Header Tank Feed Point Manifolds 10 Radiator Right Angle Flow Valve Right Angle Return Lock Shield Notes: 1. Flow to enter in side of tank. 2. Check valve to be installed as recommended on the flow line of the BCU or pump tee off. This will reduce back flow. 3. Domestic cold water inlet to lead coil. 4. Domestic hot water lead to house. 5 & 6. Both pumps are to be activated at the same temerature. 6. Field pump thermostat to activate on at 65 degrees. 7. Field pump to be *** 8 & 9. Field pump thermostat to activate on at 65 degrees. 10. Radiator flow 11. Radiator return 12. In-slab manifold flow 13. In-slab manifold return BCU on 3 7 9 11 BCU off 4 Pump BCU on 5 6 12 Pivot Stove and Heating Hydronic Manual 13 Project Number N/A Date 24/9/16 5 & 6 4 Thermostat Wiring 3 Drawn By Pivot Hydronics Checked By REV - Pivot Hydronics A- 6.00 Sheet Number 6 *NOT TO SCALE* Hydronic Systems

Hydronic Heating Installation Commissioning Procedure (Note that this is to be completed after every installation of any appliance) Step 1. Fill & Test for leaks After the installation is complete and radiators fitted off Fill the system completely, check over all pipe work and ensure that there are no leaks and the system is sound. Step 1. Bleeding the air After the fill test is complete and no leaks found. To correctly bleed each radiator, shut off all isolation valves on the manifold (cold circuit) to restrict flow to the radiators. This will isolate each line, The same can be done for the In-Slab after pressure testing. Open up the furthest line, which is generally fitted on the LHS of the manifold. Aur will build up at the top of each radiator. Using your bleed key, bleed the system until water is evident, then lock off and begin the next line. Use a bowl or cup to catch any water that bubbles out this water may be black in colour and could stain any surface contacted. As soon as air bubbles cease, turn off the air vent. After this is completed on all circuits, open all valves to allow the system to balance. Step 3. Adding Inhibitor & Test Dose Isolate one radiator and fit the inhibitor dose point to the top RHS fitting as per the instructions on the kit. Add the inhibitor as instructed and check the dosage is sufficient. Step 4. System Over View & Initial Light Run through the functions on the appliance and cover what is included in general maintenance to run the system. Explain the purpose of the thermostat and how this can be changed if boiling occurs if any circuits are isolated in future. Explain how the radiator valves can be adjusted and if fitted, the thermostatic head. Explain that the system will make NOISE from expansion. Light the stove and explain the dampening systems.