a guide to the interpretation of

Similar documents
secure signalling systems for I&HAS

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide

TECHNICAL BULLETIN No: 0040

WEBWA al Y arm 2 sig 4 nall2 in 4

Loss Prevention Standard

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

Security Systems and Alarms Inspection Board. Code of Practice For Scaffold Alarm Systems

A guide to the changes of Amendment 1 of BS

A guide to the changes between BS 8418:2010 and BS 8418:2015

A basic guide to BS 8418:2015 CCTV Systems for Installers

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Technical Specification for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

DRAFT EUROPEAN STANDARD pren NORME EUROPÉENNE EUROPÄISCHE NORM October English version

Australian/New Zealand Standard

Changes in NFPA

IMQ SPA scope as CertAlarm CCB and RTL. Last update: 12th June 2017

Loss Prevention Standard

Security Systems and Alarms Inspection Board. Code of Practice For Vacant / Void Property Alarm Systems

Specification for testing to be conducted at periodic surveillance of products and systems

DRAFT TANZANIA STANDARD

VdS Guidelines for Hazard Warning Systems (HWS) VdS 3431en. System requirements. VdS 3431en : (01)

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

August 2013 Technical Requirements for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

The New EMC Directive 2004/108/EC

Loss Prevention Standard

BS 8418: 2015 Installation and remote monitoring of detector-activated CCTV systems Code of practice

DRAFT EUROPEAN STANDARD pren NORME EUROPÉENNE EUROPÄISCHE NORM April English version

Changes for EN50131 BS8243 PD6662

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

The New EMC Directive 2004/108/EC

Confused by standards Standards for social alarms

Loss Prevention Standard

Electronic Fire and Security Systems: Intruder and Hold-Up Alarm Systems Installation (SCQF level 6)

CONNECTIONS OF CUSTOMER-PROVIDED PREMISES EQUIPMENT. CONTENTS Page

Promatrix 6000 I EN de I 1. ISO7240 PAVIRO. Installer checklist

ALARM SYSTEMS - INTRUSION AND

Electromagnetic Locking Devices Performance Requirements

HazLoc Essential Guides:

Electromagnetic Compatibility of Alarm Systems

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

User/Installation Guide

Florida Building Code 2010

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Chubb Monitoring Solutions

AS/NZS IEC :2013

600 Range Dialer Installation Manual. Version 1.0

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Fire alarm provisions for alerting the Fire Service

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Standard PRC Transmission Relay Loadability

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

COMMISSION DELEGATED REGULATION (EU) /... of

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Technical standards to support the evolution of technology enabled care services

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Technical Bulletin CE marking: from 1st July 2013

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

INTERNATIONAL STANDARD

AS/NZS IEC :2016

GRADESHIFT UDL INSTRUCTION MANUAL

User/Installation Guide

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

TECHNICAL BULLETIN No. 0018

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

Loss Prevention Standard

Code of Practice for Design, Installation, Commissioning & Maintenance of Duct Smoke Detector (DSD) Systems

Vocia VACIE. Reference Guide

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

Fire detection and fire alarm systems

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

26 of 128 9/23/2014 9:25 AM

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

VACIE REFERENCE GUIDE REVISION 1.2.6

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

Changes to UK alarm standards. PD6662:2010 April Honeywell Security

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

Shipboard incinerators with capacities up to 4000 kw

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

Guide to Membership Assessments

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

PD6662:2010. A guide from Honeywell Security Group

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

AS/NZS IEC :2016

Guidance on Video Smoke Detection Technology (VSD)

Transcription:

a guide to the interpretation of EN50136-1-1 & EN50136-2-1 for alarm transmission systems & equipment June 2007 For other information please contact: British Security Industry Association t: 0845 389 3889 f: 0845 389 0761 e: info@bsia.co.uk www.bsia.co.uk Form No. 201. Issue 1 This document is the copyright of the BSIA and is not to be reproduced without the written consent of the copyright owner.

Contents 1. Introduction 3 2. Scope 3 3. Abbreviations 3 4. References in EN50131-1 relevant to the ATS 4 5. Clarification of requirements of EN50136-1-1 6 6. Clarification of requirements of EN50136-2-1 8 Page 2

1. Introduction The EN50136 family: Alarm systems Alarm transmission systems and equipment - has been in force for some years. In the process of developing products to this family of standards following the introduction of European standards for the intruder alarm industry through the implementation of the PD6662:2004 scheme, it has become clear that some clarification and guidance is needed in relation to these standards. It is intended this guideline can be used by manufacturers to self-certify their products to conform to the European standards, or be offered to a test house to clarify relevant tests and results. This guidance document may change as other product specifications (Technical Specifications) are published and adopted in the UK or changes are made to the PD 6662 scheme. Only those items in the EN50136 family that give concern are listed. All other clauses or parts of the European standards are believed to be self-explanatory and already in line with the requirements of PD 6662. Advisory note: This guide has been produced for use in PD6662:2004 Scheme for the application of European standards for Intruder and Hold up alarm systems. With the implementation of PD6662:2010 and the dual running period associated with this transition, other BSIA Industry guidance may have been produced for the later Scheme and therefore you should ensure you seek the appropriate guidance. If you are unsure please contact the BSIA Technical team on 085 389 3889 or email: technical@bsia.co.uk 2. Scope The EN50136 family of standards is relevant to alarm transmission systems designed for and used in all types of alarm system including fire and social alarms. This document is relevant specifically to the use of such systems in intruder alarm systems installed to the EN50131 family of standards (UK PD6662 scheme). Notes: (i) (ii) References to EN50131-1 are taken from pren50131-1:2004, unless otherwise stated. The EN50136 family of standards includes requirements for availability that are not called up by EN50131-1 for I&HAS and hence are not mandatory for ATS used with such systems. However, where the ATS is shared with fire and/or social alarm systems, the requirements of EN54-21 and/or EN50134-5 become relevant, making the availability requirement mandatory. This should be taken into account in the implementation of this guide. 3. Abbreviations SPT RCT Supervised premises transceiver Receiving centre transceiver These terms (as defined in EN50136) are more specific than the generic alarm transmission equipment (ATE) and are therefore preferred where relevant. Page 3

4. References in EN50131-1 relevant to the ATS Clause 6 Security Grading This clause identifies the various security grades that may be used. The specific requirements for these grades are identified in Tables 10 and 11. Clause 7 Environmental Classification This clause details the conditions for the environmental classes permitted for components falling within the EN50131 family, with associated test procedures to verify equipment suitability detailed in EN50130-5. Environmental requirements and tests for ATE are found in EN50136-2-1. Clause 8.1.4 Recognition of Faults Table 1 identifies the types of fault that must be identified within the I&HAS. The requirement for ATS fault does not require the identification of the specific type of fault or of the specific path affected where multiple paths are provided. Details of information requiring transmission via the ATS are in Table 7. Note 1: PD6662:2004 Clause E.1.1 confirms that I&HAS fitted with dual path ATS should respond to an ATS fault affecting one path only, without requiring identification of which path. Note 2: Certain requirements (eg clause 8.6 paragraph 6) require that the CIE be able to distinguish between faults affecting all paths and faults affecting only one path. Note 3: Fault signals may be notified globally or be individually identified. Clause 8.3.1 and 8.3.2 Access Levels These access levels are for the I&HAS. EN50136-2-1 identifies the specific recommendations for ATE. It is not mandatory for all levels to be provided if not relevant. Clause 8.3.3 and 8.3.4 Setting and Unsetting For UK purposes, DD243:2004 details acceptable methods of setting and unsetting including remote execution from the ARC. Clause 8.3.9 Restoring Restoration is dealt with as a SYSTEM function not being specific to the SPT or any other individual piece of equipment. Remote restoration whether electronic or by anticode is permitted, provided the requirements of clause 8.3.2 are met. Page 4

TABLE 7 Processing of Signals This table identifies the information that must be transmitted to the ARC. For the UK, additional information is mandatory, as defined in DD243:2004. Note: The reference to zone in note ** to this table must be understood in the context of the definition at 3.1.85. It does NOT refer to the individual device generating the alarm, but to the zone (ie geographical area, etc) in which the device is located. Table 22 illustrates this difference. Clause 8.4.5 and 6 Masking and Reduction of Range The required response to these conditions is EITHER intruder OR fault. It is NOT specified that this should be separately identified to the ARC. Note: UK insurers have requested intruder response for masking events. Clause 8.5 Indications This clause and associated tables prohibit indications at level 1 that are permitted by EN50136-2-1 clause 5.1.1 Clause 8.6 Notification See note to clause 8.1.4, above. This clause also identifies I&HAS responses to ATS faults, including different responses applicable if an ATS fault affects ALL paths. Note: A means of differentiating whether ATS faults affect one path only or all paths is detailed in BSIA Form 175. TABLE 10 Notification requirements a) Where two ATS are specified to meet the requirements of table 10, this should be understood as a standard dual-path system, with the two paths meeting the separate requirements (see Form 171; 8.6 d). b) It has been agreed that equipment used for purposes other than compliance with Table 10 (eg for Up/Down-Loading) is NOT required to comply with the requirements of EN50131-1 table 11, provided that it does not interfere with the mandatory ATS (see Form 171; 8.6 e). c) This table identifies the MINIMUM notification requirements for each I&HAS grade and notification sub-grade. Additional requirements may be imposed by insurers, including the specification of ATS of a superior grade to the I&HAS. TABLE 11 ATS Performance criteria This table identifies how the performance criteria identified in EN50136-1-1 are used to identify the suitability of an ATS for a specific grade and notification sub-grade of I&HAS. Clause 8.7 Tamper Security Where the SPT is individually housed, it must, as a minimum, meet the tamper security requirements for the associated CIE. Page 5

Clause 8.7.3 Monitoring of Substitution Note that this requirement (grade 4 only) is relevant however the equipment is housed, but would not appear to be relevant if the ATE is integrated into CIE. Clause 8.8 Interconnections Note that this requirement is specific to interconnections between components of the I&HAS and thus includes the connection between CIE and SPT. It is NOT relevant to the communication between SPT and RCT. Clause 8.8.4.1 Verification integrity periodic communication For interconnections between CIE and SPT using simplex communication (eg parallel communication), the requirement of this clause may be considered to be satisfied by the SPT initiating a message to the ARC in accordance with EN50136-1-1 clause 6.3.3. Where duplex communication exists (eg serial communication), the fault shall be detected by the CIE. Clause 8.8.5 Security of Communication This requirement includes the communication between CIE and SPT. Note that it is applicable to grade 4 I&HAS only (PD6662:2004 E.5). Clause 8.10 Table 22 Event Logging Note that log events may be stored at the CIE or at the ARC. If the latter, measures must be in place to deal with interruptions to communications. Clause 9 Power Supply The requirements for PSU included as part of SPT are specified in EN50131-6. Clauses 14 and 15 Documentation and Marking Documentation and marking for SPT intended for use in an I&HAS must comply with these requirements in addition to those shown in EN50136-2-1. 5. Clarification of requirements of EN50136-1-1 Clause 1 Scope The concept of Up- & Down-Loading to / from the I&HAS is not mentioned in this family of standards. This does NOT preclude its use (see reference to EN50131-1 Table 10, above). Clause 4.5 Alarm transmission equipment and clause 4.24 Transmission networks Comparison of pren50136-1-5 clause 5 with the notes to these two definitions identify that equipment that is part of the ATS and located at the supervised premises (eg an IP modem or router) may be considered to be part of the transmission network, and is therefore NOT subject to the requirements of EN50136-2-1. Hence, it is also not subject to the requirements of EN50131-1. See also clause 5.2. The point of decision as to which path is used must be part of the CIE or SPT. Page 6

Clause 4.16 Monitoring Centre The use of this term includes any manned location that monitors, modifies, stores and/or forwards intentionally the alarm information. Clause 5.2 Alarm transmission system configuration The use of a second transmission path as described in this clause is specifically to enable the ATS to meet the availability requirements of EN50136-1-1. As EN50131-1 table 11 currently excludes availability requirements, the reference here and at clause 6.3.4 - is not relevant to ATS for I&HAS. The general requirements for a second path when used with an I&HAS are identified by EN50131-1 tables 10 and 11. Clause 5.4 Alarm transmission system classification As EN50131-1 table 11 currently excludes availability requirements, the classification of ATS for I&HAS is independent of this requirement. Clause 6.3.3 Monitoring of the interconnection with the alarm system It should be noted that this clause deals only with the requirements for the ATS. Requirements for indication of a failure of this interconnection at the I&HAS is dealt with by EN50131-1. See reference to EN50131-1 clause 8.8.4.1, above. Clause 6.3.4 Monitoring of the alarm transmission system The requirement of paragraphs 2 and 3 are specific to meeting availability requirements, as noted at 5.2 (above). Clause 6.4 Alarm transmission system availability including clauses 6.4.3, 6.4.4 and 6.4.5 At present this requirement is NOT called up by EN50131-1 table 11, so that these requirements are not applicable to ATS used with I&HAS. Clause 6.4.2 Alarm transmission assurance This clause requires that means be provided without mandating that it actually be used. It is expected that it will always be used. Clause 6.5.2 Information security The description of encryption algorithms in this clause has been deemed unworkable by the CENELEC Working Group reviewing this standard. The replacement proposed in pren50136-1-5 (clause 6.1) should be used. Clause 7.4 Transmission time The last paragraph of this clause appears to require complex fault logging at the ATE/CIE, which an optional ATE function according to EN50136-2-1 (clause 5.8) and is grade dependant at the CIE. Whilst this function may be carried out at the supervised premises, records at the ARC should always be analysed. Clause 7.5.1 Records At present availability is NOT called up by EN50131-1 table 11, so records specific to this requirement are not required. Page 7

Clause 7.5.3 Analysis Note 2 suggests that there will be a single organisation with overall responsibility for the entire ATS (ie SPT, transmission path, and RCT). This is impossible. The note is informative (and in any case relates to availability which is not required by EN50131-1) and may therefore be disregarded. 6. Clarification of requirements of EN50136-2-1 Clause 5.1.1 Access Level 1 Certain indications permitted at level 1 by EN50136-2-1 are permitted only at level 2 by EN50131-1 (Tables 8 and 9). Clause 5.1.2 Access level 2 Modification of the operating status at access level 2 is restricted to functions permitted by EN50131-1 (eg inhibit) when accessed through the CIE. Clause 5.1.3 Access level 3 This clause requires that level 3 access at the supervised premises be annunciated to the ARC before any ATS parameters are changed. This may be impossible with current equipment where extended format reporting is not in use and reporting channels are limited. Where this is so, the requirement of EN50131-1 Table 22 to log site parameter changes made at site should be applied at all grades. Clause 5.2.3 Parameter read-out The combination of possible, required and allowed in this clause is confusing. It should be taken to read: Read-out of the parameter settings shall be possible at level 3. Clause 5.11 Transmission time Where timings are based on the operation of a switch connected to an input to the CIE, it should be remembered that EN50131-1 allows up to 10.4 seconds for the CIE to detect and process such an action and longer in the case of certain system faults. Clause 6.2 Interface test This test is not required where the SPT is integrated with the CIE. Clause 6.2.1 General interfaces a) This clause includes the requirement for PSUs to be tested to their limits. Test requirements for PSUs used with I&HAS are as specified in EN50131-6. b) In the case of systems using extended format reporting or a serial interface, the requirement for the interface to be tested for transmission of all different alarm conditions should be taken to mean all different types of alarm condition not to alarm conditions from every possible source. Clause 6.2.3 Serial interfaces Each possible alarm message in paragraph 2 should be taken to mean each possible type of alarm message, as in comment re 6.2.1 (above). Page 8

Clause 6.5 Equipment for monitored systems a) Paragraph 2 applies to messages generated to the ARC NOT to the CIE (see comment re clause 6.3.3 of EN50136-1-1, above). b) Item b does not refer to fuses / PSUs that are being used for purposes other than powering the ATE. c) Item b does not apply if loss of power is immediate (see clause 5.4). Clause 7 EMC testing and requirements The current standard for emission requirements is EN61000-6-3 and for susceptibility is EN50130-4. 7.1.2 Supply voltage dips and interruptions (operational). The tests in this section are specific to PSUs, so apply only to SPT supplied with integral PSU. Page 9