S Voltage Regulators

Similar documents
COOPER POWER SERIES. QD3 Quik-Drive Tap-Changer Position Indicator Drive Gear Kit Number B11. Voltage Regulators MN225056EN

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

COOPER POWER SERIES. Mounting bracket KA19H3 assembly and installation instructions. Reclosers MN280072EN

Effective May 2017 Supersedes October 1998 (S )

COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

COOPER POWER SERIES. Reclosers MN280015EN

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

ARM SERIES Switching Relays With Priority

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

Item Model Description Voltage Amps Watts Plug

INSTALLATION GUIDE Fryer Module

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Easy-Lam School Budget Roll Laminator

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road Dunkirk, NY ARH-1 ARH-2 ARH-3

INSTALLATION GUIDE Induction Cooktops

Item Model Description Voltage Amps Hz

Power Supply Display Module PSDM. Installation and Operation Manual

Dielectric Fluids. Envirotemp FR3 Fluid Storage and Handling

DISPOSER CONTROL CENTER

ARGO DPM-2 OUTDOOR TEMPERATURE SETBACK CONTROL

INSTALLATION GUIDE Steamer Module

Owner's Manual TABLE OF CONTENTS

USERS INFORMATION MANUAL

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Fall Detection and Alert

U ser's Guide PC6010

MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL

Series: MBC1-TC Mini Benchtop Temperature Controller

Operator s Manual CHEESE MELTER/WARMER OVEN ENGLISH

Trainee Handbook. Module 0.1. JSTC Rules and Safety Procedures

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

SECTION 1-1 SAFETY PRECAUTIONS

HI COD REACTOR and Test Tube Heater 2008 Series

INSTALLATION INSTRUCTIONS

UV Lamp and Quartz Sleeve Replacement/Maintenance

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

SECTION 1-1 SAFETY PRECAUTIONS DOUBLE ARM MIXER CHAPTER 1: SAFETY

PISTON DEPOSITOR TABLE OF CONTENTS

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

26 LB CAPACITY ICE MAKER

ORP/MILLIVOLT CONTROLLER

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Remote Relay Module (RRM)

Model SS2000C31 SmartSystem Load Management System

INSTALLATION INSTRUCTIONS

CH750, CH751 & CH951 CHILLERS

The Professional s Choice

Installation and Operation Manual

Installation and Operating Instructions

Dual Column Dehydrating Breather Manual

Fig. 1 - Unit PHD4 and WPH4

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Installation Instructions

INSTALLATION AND OPERATION MANUAL TURBO CONVECTION OVEN TCO85

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

FDCL221 Line separator

Automatic Water System Pump SERIES

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

Installation Instructions

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

Owner s Information Manual

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Control Panel User Guide

Installation Instructions

Liebert InteleCool Warranty Inspection Check Sheet

CHILLER. Model CH3000. Operator s & Installation Manual

OPERATING & MAINTENANCE INSTRUCTIONS

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Installation Instructions

Installation Instructions

Owner's Manual TABLE OF CONTENTS

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

User Manual. 40 Tower Fan MODEL: WFTR40W

Overload LED On & Power LED On

Solution Ultima Series Operators Manual ISSUE 1.00

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

Transcription:

Voltage Regulators Tap-Changer Diagnostics Contents Product Information........................... 1 Safety Information............................ 2 Setup Procedure.............................. 3 Product Information Introduction Tap-Changer Motor Trouble Diagnostics Output (TCMT): A Status Indication/Alarm introduced with the January 2009 release of the Leader/Follower version of CL-6 firmware (rev 1.06.20). TCMT will detect and notify you of impending mechanical problems with your voltage regulator. An active status of this output indicates a problem preventing the tap-changer motor from performing or completing (or the control not sensing) an operation either called for by an Automatic Regulation Tapping request or a Remote Manual Tapping request received through Digital SCADA communications. Problem detection includes but is not limited to the following: Blown motor fuse Failed/failing motor capacitor Failed/failing tap-changer motor Stalled tap-changer motor Faulty motor signal output wiring Failed/failing holding switch circuit Failed/failing control motor circuit components Incorrect setting of controls tap-changer configuration (FC049) This Output is available through SCADA or separately as a configured CL-6 Alarm State as defined in this document. Read This Manual First Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment Additional Information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user's purpose, please contact your Cooper Power Systems sales representative. Quality Standards Service Information S225-11-6 ISO 9001 Certified Quality Management System 0112 New Issue 1

Tap-Changer Diagnostics Cooper Power Systems products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Cooper Power Systems employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission. The instructions in this manual are not intended as a sub stitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. This manual may contain four types of hazard statements: DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING: Indicates a hazardous situation which, if not avoided, could result In death or serious injury. Hazard Statement Definitions CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Caution: Indicates a hazardous situation which, if not avoided, could result in equipment damage only. Information Safety Instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER: Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. WARNING: Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. WARNING: This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. WARNING: Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. 2

S225-11-6 SCADA Reporting Setup procedure Called Motor Trouble, this DNP Status (Object 1/2, factory Mapped Index 090, Internal Absolute point #103) can be read/ reported from the control and can be included in any custom user defined map. Factory configured mapping is shown here. Figure 1. DNP Data Dictionary Mappings, User 1. There are two things to note when using SCADA communication to monitor the Motor Trouble State: 1. The DNP Status is not dependant upon being configured as an Alarm to be read/reported through DNP communications. 2. The status will become active any time the control sends a tap command and it is not successfully completed. The status will not clear until the control sends a tap command and the regulator completes a successful tapping operation. While the status is active, the control will continue to send a tapping command every 30 seconds as long as the sense voltage remains out of band. 3

Tap-Changer Diagnostics Configuring the Status Alarm Called Motor Trouble, this Status Alarm can generate Events, System Profile snapshots, and report an alarm state. In the example below, this Alarm feature is configured to: 1. Illuminate the Red Alarm LED on the CL-6 front panel, (assigning a priority value between 1 and 50, has the effect of illuminating the alarm LED when the status item is active). 2. Record a time and date stamped Event in the Event Recorder. 3. Record a System Profile Snapshot in the Data Profiler. Figure 2. Alarm Configuration. 4. Report the Alarm state through DNP for a standard Class 0 Static scan and/or a Class 1 Event scan. Figure 3. DNP Data Dictionary Mappings, User 2. 4

S225-11-6 Diagnostic Output Supplementary Settings 1. For both native SCADA reporting and Status Alarm Indication, in order to prevent false-positives due to the tapchanger.being at the limits (Hard position indicator limit switches are factory set to 16 Raise and 16 Lower), the Soft- ADD-AMP Feature must be enabled and the limits set to match the position indicator limit switches. Figure 4. All Settings. 2. For Status Alarm Indication, Status Alarms must be enabled in the control: Figure 5. All Settings. 5

Tap-Changer Diagnostics Proactive Testing of the Motor Circuit The Tap-Changer Motor Trouble Problem Diagnostics Output (TCMT) can be combined with the Preventative Maintenance Tapping (PMT ) feature to regularly test the motor circuit. By setting up the TCMT and then enabling PMT Mode A configured with a 1 day countdown timer, as shown in Figure 6, the control will exercise the motor circuit a minimum of once a day. The complete operation takes less than 1.5 seconds to perform with a Quik-Drive (QD) Tap-Changer on a Cooper Power Systems Voltage Regulator. Figure 6. All Settings. 6

S225-11-6 PMT also includes the added benefit of insuring that along with the base Tap-Changer Movable Contact operation (PMT Mode A), the Tap-Changer Reversing Switch is also operated (PMT Mode B). PMT Mode B can be enabled using the steps in Figure 7. Figure 7. All Settings. When PMT Mode B is active, unless the normal tap-changer operation has caused the mechanism to cycle through neutral at least once during the day, the control is going to run it up one step past neutral and then back to its original position (on Cooper Power Systems QD mechanisms the operation time is less than 5 seconds). In this example, the operation will take place between 1:00 and 2:00 AM as long as the load current of the system does not exceed 50% of rated value. Contact your Cooper Power Systems representative to answer questions or assist with implementing Tap-Changer Motor Trouble Diagnostics (TCMT) Outputs. 7

Tap-Changer Diagnostics 2012 Cooper Industries. All Rights Reserved. Cooper Power Systems, ADD-AMP, Quik-Drive, and PMT are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written permission of Cooper Industries. One Cooper www.cooperpower.com Online S225116 Rev 0 2300 Badger Drive Waukesha, WI 53188 USA 8