DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Similar documents
LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation WARNING SXWS9561. Stainless Steel Panel Shower

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation Instructions

Terreon Lav Decks WARNING

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

LA90 DISCONTINUED IMPORTANT!

LA45 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Models: FM FM WARNING

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation Instructions OBSOLETE

Installation Instructions

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation Instructions

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

PAT BASIN MODEL 9121, 9131, & 9141

Installation. S Series Navigator Thermostatic Mixing Valve

Installation Instructions

Installation Instructions

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

Installation Instructions

Installation Instructions

FAQ s ABOUT TOPZERO STAINLESS STEEL SINKS: >What type of stainless steel does TopZero use?

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

01694-REVC_081315_ENGLISH

Installation Instructions

LVSD2 Verge Wash Basin LVS-Series

Stainless Steel. Care and Cleaning. Mott Manufacturing Limited PO Box 1120 Brantford, Ontario N3T 5T3 Canada

Installation Instructions

Installation & Operation Manual

Installation & Operation Manual

MERIDIAN MODEL# 3793

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

FL-2H, FL-2L Frequency Lavatory System FL-Series

Drop-In Installation Instructions. Undermount Installation Instructions

KOHLER Care and Cleaning Guide

Installation and Maintenance Instructions

Installation S

SS-1N Express Lavatory System SS-Series

Please do not return this product to the retailer!!! If you find that you have any trouble with assembly or missing or damaged parts please contact

Chiller with BP-1 1/2 oz Pump

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Installation & Operation Manual

Installation S

Installation S

RIGA ZUHNE

Installation S

Installation S

Care and Maintenance Guide

Express Lavatory System SS-Series

Product Care and Maintenance Information

Kitchen Solutions. Sophisticated Affordable Elegant. Stainless Steel.

MODENA ZUHNE

LD-5010 OmniDeck with WashBar 5000 Series

TSL-Aerofoil. wall mounted basin. installation + maintenance

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Syrup Server. Thank You MODEL: SY MODEL: SY for purchasing this Syrup Server to heat and neatly dispense sticky syrups and sauces.

Ligature Resistant. ADA Compliant

CARRON PHOENIX Homecare Pack

Care & Maintenance Kastell Kitchens

GRANITE COMPOSITE SINK

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE

LVSD2 Verge Wash Basin LVS-Series

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

INSTALLATION AND CARE GUIDE MARCO VANITY FRAME BASE & SINKTOP E E E E052463

Bottle Pump. Thank You MODEL: BP-1

INSTALLATION INSTRUCTIONS

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

LVQD3 Verge with WashBar Technology LVQ-Series

INSTALLATION & OPERATION MANUAL

INSTALLATION INSTRUCTIONS

Classic 6 & 18 Prep Procedure Tables Owner s Manual

Composite Sinks Installation, Use and Maintenance

ConserveWell DROP-IN UNIT

We recommend regular maintenance to keep your sink looking its best!

Transcription:

OmniDeck - 4000 Series -3 shown with optional equipment Table of Contents Supplies Required... 2 Components... 3 4 Dimensions... 5 6 Rough-Ins... 7... 8 Cleaning and Maintenance... 9 215-1702 Rev. C; ECN 13-11-001 2013 Bradley Page 1 of 9 7/31/2013 P.O. Box 309, Menomonee Falls, WI USA 53052-0309 PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817 bradleycorp.com

IMPORTANT! THIS SIDE UP Packing List Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical power MUST remain off until installation is completed. After installation is complete, turn on the water supply first, then turn on the electrical power. Hardware supplied by installer must be appropriate for wall construction. Wall anchors used must have a minimum pull-out rating of 1,000 lbs. Product warranties and service parts information may be found on our web site at bradleycorp.com. Supplies Required (by others) ½" Nominal copper tubing for hot/cold or tempered supply piping 1½" NPT drain piping PC-Concrete injectable repair and anchoring epoxy or equivalent For Optional Mounting Brackets: ³ ₈" wall anchors and fasteners For Optional Trap Cover: four #10 wall anchors and fasteners (for each cover) Screen filter(s) as needed, if not included with faucet(s) 2 7/31/2013 Bradley 215-1702 Rev. C; ECN 13-11-001

Optional Components Strainer and ADA Offset Tailpiece (269-1751) Trap Cover for Rectangular Undermount (S45-2708) Trap Cover for Spherical Undermount (S45-2704) 1½" Polypropylene P-trap (269-1697) or 1½" Polished Chrome-Plated Brass P-trap (S29-094) Left-hand Mounting Bracket with Mounting Strip (S45-2452LH) Right-Hand Mounting Bracket with Mounting Strip (S45-2452RH) TMA Prepack (S45-2703) Waste Receptacle with Textured Lid Putty (S50-372) Coal (S50-372B) Handle Repair Kit (S65-244) Base Leveler Repair Kit Stainless Steel (S65-245) Plastic (S65-287) Bradley 215-1702 Rev. C; ECN 13-11-001 7/31/2013 3

Optional Components Plug-in transformer option (PT) includes Transformer (S53-338), Adapter (S53-339), and Grounding Kit (S53-349) for CAP-DCG and CAP- DCA Faucets Optional Transformer P19-231F IR-DCD Faucet (S53-336) Battery Box for CAP-DCG and CAP- DCA Faucets CAP-DCA Faucet (S53-334) Plug-In Transformer Option (PT) for IR-DCD Faucet (S53-337) 6315-KT0000 Soap Dispenser Kit (batteries and 1000-shot soap included) 6324 Soap Dispenser, Plastic Globe (16-oz.) 6324-67 Soap Dispenser, Stn. Steel Globe (16-oz.) 6324-68 Soap Dispenser, Plastic Globe (32-oz.) 6334 Soap Dispenser 4 7/31/2013 Bradley 215-1702 Rev. C; ECN 13-11-001

Dimensions Dimensions for three-station lavs are shown and are for reference only. Dimensions for other configurations are similar. with Evero Rectangular Undermount Bowl 4⁵ ₈" (117mm) 12" (305mm) Min. 24" (610mm) Max. with Stainless Steel Spherical Undermount Bowl Apron height 15" ADA (381mm) 15" ADA (381mm) 45" ADA (1143mm) 12¼" (311mm) Floor 75" ADA (1905mm) To Be Determined 16" (406mm) 45" ADA (1143mm) 75" ADA (1905mm) To Be Determined Side splash height 34" ADA 4¼" (108mm) 11¼" (286mm) Min. 24" (610mm) Max. Apron height Side splash height 34" ADA Floor Bradley 215-1702 Rev. C; ECN 13-11-001 7/31/2013 5

Dimensions - Side View Standard Height (Evero Rectangular Undermount Bowl) 14⁵ ₁₆" (364mm) Standard Height (Stainless Steel Spherical Undermount Bowl) 15¹ ₈" (384mm) 34" 27" (686mm) Juvenile Height (Rectangular Undermount Bowl) 17" (432mm) 14⁵ ₁₆" (364mm) 15¾" (400mm) 34" 27" (686mm) Juvenile Height (Spherical Undermount Bowl) 17" (432mm) 15¹ ₈" (384mm) 15¾" (400mm) 31" (787mm) 31" (787mm) 24" (610mm) 12¾" (324mm) 24" (610mm) 12¾" (324mm) 17" (432mm) 17" (432mm) 6 7/31/2013 Bradley 215-1702 Rev. C; ECN 13-11-001

1 Rough-Ins Typical bowl deck installation is shown. Other bowl configurations are similar. Mounting bracket locations will vary depending on deck configuration. Juvenile height counter surface mounting is 31" (787mm) max. Adjust all other juvenile height mounting locations accordingly. Rectangular undermount trap cover is shown. Stainless steel spherical trap cover rough-in is similar. 12½" Variable (318mm) Min. with Battery Box 2" (51mm) 2" (51mm) 1½" (38mm) Trap Cover 4" (102mm) 27" (686mm) 1 (483mm) 5½" (140mm) 8¼" (210mm) Ref. 5¾" (146mm) 3¼" (83mm) 5⁵ ₈" (143mm) 11¼" (286mm) 24" (610mm) 27¾" (705mm) 34" Counter Surface Max. ADA Finished Floor Code Description Qty. A ³ ₈" Bracket Anchors With a Min. Pull-Out Force of 1,000 Lbs. (Reinforce Wall at Anchor Points) 2 per bracket B #10 Wall Anchors and Screws 4 H, C ½" Nominal Copper Tubing for Hot/Cold Supplies (or Tempered Line), Stub-Out 2" from Wall 2 D 110V GFI Protected Electrical Outlet (AC Option Only) 1 E 1½" NPT Drain, Stub-Out 2" from Wall 1 F #10 Anchors and Screws (TMA Option Only) 2 G ¼" Wall Anchors and Screws (Provided) (CAP-DCG, CAP-DCA and IR-DCD Faucet Options Only) 4 Bradley 215-1702 Rev. C; ECN 13-11-001 7/31/2013 7

2 Apply PC-Concrete injectable repair and anchoring eopxy (or equal) to the top of the mounting strips (left-hand bracket shown). CAP-DCA faucet shown, others are similar 6324 soap dispenser shown, others are similar CAP-DCA battery box Drain Plastic hose from TMA/Tempered Line Adaptor to battery box. Drain and P-trap (view from top of bowl) P-trap elbow Position the trap covers snug to the underside of the basin. Secure the trap covers to the wall with four #10 fasteners (supplied by installer). P-trap rotated back to fit up with the strainer Strainer and P-trap to be assembled as shown for proper fit-up of trap cover. Strainer elbow rotated toward the back wall 8 7/31/2013 Bradley 215-1702 Rev. C; ECN 13-11-001

Cleaning and Maintenance for Evero Material Description: Evero Natural Quartz Material is made from a blend of acrylic modified bio-based polyester resin, natural quartz, granite, and other exotic minerals and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Routine Cleaning: For regular cleaning, use standard commercial or household products such as Simple Green, Creamy Cleanser brand, Formula 409 or Windex. Stubborn Stains: Remove tough stains, with non abrasive cleaners and pads such as a white Scotch Brite pad and Lysol. Special Situations for Evero Material Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit thoroughly after cleaning. Restoring the surface: Refresh and restore the rich surface with a color enhancer such as Tenax Ager, if needed. NOTICE! Do not use strong acid or alkaline chemicals and cleansers to clean Evero. If these chemicals come in contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects. Repair Kits: Evero repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days. Evero is a unique, cast solid surface material. Aggregate flow and distribution as well as shades of color can vary from product to product creating natural characteristics. Cleaning and Maintenance for Stainless Steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. Always start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia. Apply the cleaning solution per the manufacturer's instructions and always use a soft cloth or sponge to avoid damaging the finish. Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball stainless steel cleaner or a soft abrasive. Always follow the manufacturer's instructions and apply in the same direction as the polish lines. NOTICE! Never use ordinary steel wool or steel brushes on stainless steel. Always use stainless steel wool or stainless steel brushes. Fingerprints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance with the manufacturer's instructions. Many of these products leave a protective coating that helps prevent future smears and fingerprints. Grease and Oil: To remove grease and oil use a quality commercial detergent or caustic cleaner. Apply in accordance to the manufacturer's instructions and in the direction of the polish lines. Precautions: Avoid prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thiocyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment, especially if acid conditions exist. NOTICE! Do not permit salty solutions to evaporate and dry on stainless steel. The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the stainless steel structure. NOTICE! Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear. The use of these cleaners should be avoided. Brand Names Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. Bradley 215-1702 Rev. C; ECN 13-11-001 7/31/2013 9