Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle

Similar documents
High efficient heat pump system using storage tanks to increase COP by means of the ISEC concept - Part 1: Model validation

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Development of a gas fired Vuilleumier heat pump for residential heating

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

Feasible Working Domains Decision Support for Heat Pump Projects

Modelling of Split Condenser Heat Pump with Limited Set of Plate Heat Exchanger Dimensions

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Influence of Compressor Control Strategy on Energy Efficiency and Product Temperature for Professional Counter Cabinets

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Can painted glass felt or glass fibre cloth be used as vapour barrier?

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

Compression of Fins pipe and simple Heat pipe Using CFD

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Chapter 9. Refrigeration and Liquefaction

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

(Refer Slide Time: 00:00:40 min)

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Shortcut Model for Predicting Refrigeration Cycle Performance

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Comparison of fin-and-tube interlaced and face split evaporators with flow maldistribution

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Cooling load calculations of radiant and all-air systems for commercial buildings

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Modelling the Performance of a Diffusion Absorption Refrigeration System

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Sub-Critical Operation of the CO2 Expander/ Compressor

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Applications of Thermodynamics: Heat Pumps and Refrigerators

International Journal of Informative & Futuristic Research ISSN (Online):

On the Architectural Engineering Competences in Architectural Design MSc in Engineering with Specialization in Architecture Kirkegaard, Poul Henning

Comparison of radiant and convective cooling of office room: effect of workstation layout

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Moisture permeability of some porous materials

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Energy and Exergy Performances of Air-Based vs. Water-Based Heating and Cooling Systems: A Case Study of a Single-Family House

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Efficiency of Non-Azeotropic Refrigerant Cycle

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Global Journal of Engineering Science and Research Management

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

CL4001 HEAT TRANSFER OPERATIONS

Performance of an Improved Household Refrigerator/Freezer

Homework Chapter2. Homework Chapter3

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Chapter 10 VAPOR AND COMBINED POWER CYCLES

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Thermal Environment Evaluation in Commercial Kitchens of United States

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

An interdisciplinary approach to identify adaptation strategies that enhance flood resilience and urban liveability

Engineering Thermodynamics. Chapter 7

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Air and operative temperature measurements in a plus-energy house under different heating strategies

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

Operation and maintenance service provision in uncertain times the case of the FLSmidth Group during the Arab Spring

Villa Bagatelle Technical Report

Households' energy use - which is the more important: efficient technologies or user practices? Gram-Hanssen, Kirsten

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Transcription:

Downloaded from orbit.dtu.dk on: Oct 18, 2018 Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle Carlson, H; Commisso, Marcello Benito; Lorentzen, Bent Published in: Proceedings of the 25th Intersociety Energy Conversion Engineering Conference Publication date: 1990 Document Version Publisher's PDF, also known as Version of record Link back to DTU Orbit Citation (APA): Carlson, H., Commisso, M. B., & Lorentzen, B. (1990). Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle. In Proceedings of the 25th Intersociety Energy Conversion Engineering Conference (Vol. Volume 5, pp. 366-371). IEEE. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

MAXIMUM OBTAINABLE EFFICIENCY FOR ENGINES AND REFRIGERATORS BASED ON THE STIRLING CYCLE H. Carlsen, M.B. Commisso, B. Lorentzen The Technical University of Denmark DK-2800 Lyngby ABSTRACT The efficiency of the ideal stirling cycle assumes, that the cylinder volumes are isothermal and that the temperatures in the cylinder volumes are identical to the temperatures in the heat sink and the heat source. The efficiency is then identical to the efficiency of the Carnot cycle. However, in a real stirling machine the cylinder volumes are nearly adiabatic instead of isothermal, and the heat is added or removed in heat exchangers. Then the efficiency of a stirling cycle will always be smaller than for a carnot cycle even with ideal heat transfer in.regenerator and heat exchangers. Especially for stirling based refrigerators, which have been discussed recently as an alternative to refrigerators using CFC-gases, the maximum obtainable coefficient of performance is important. Based on a simplified stirling cycle with ideal heat exchangers and regenerators, the maximum possible efficiency and dimensionless output for a stirling cycle as a function of dead volume, phase angle and temperatures in heat sink and heat source are calculated and compared with the efficiency of the carnot cycle. Also the influence of heat transfer in the cylinder volumes is analyzed, and the effect of "isothermalizers" are discussed. 1. INTRODUCTION The stirling cycle is a closed cycle, were the working medium, which is a gas, is expanded and compressed at different temperatures. In the idealized cycle, expansion and compression are isothermal. Expansion and compression take place in separate cylinder volumes as shown in fig. la. Heat is added from the heat source in the expansion volume at the temperature T, and removed from the compression volume to the heat sink at the temperature T,. As the temperatures are different in the two cylinder volumes, heat is stored in a regenerator. When the gas flows from the hot volume to the cold volume heat is stored. This heat is used for heating the gas, when it flows back from the cold to the hot volume. The stirling cycle can be used for an engine and for a refrigerator as well. If regeneration in the regenerator is perfect and all losses are assumed zero, the ideal stirling cycle has the same efficiency as the Carnot cycle. This requires that the cylinder volumes are isothermal and that there is no temperature difference between the gas in the cylinder and the heat sink and heat source respectively. SYMBOLS A, :Gas flow area A, : Heat transfer area c, c, : Specific heat capacity dh : Hydraulic diameter h : Coefficient of heat transfer L : Heat exchanger length M : Mass of gas m P Q R T : Mass flow : Gas pressure :Heat : Gas constant : Temperature V : Volume vo : Expansion space swept volume W :Work a : Crank angle 0 : Phase angle Dimensionless variables COP : Coefficient of performance : Carnot-COP e? : Number of transfer units Pr : Prandtl number St Stanton number n : Efficiency n : Carnot-efficiency P : Pressure (-4 : Heat T : Temperature V : Volume f : Volume ratio W : Work Indices C D E H W tot : Compression volume : Dead volume : Expansion volume : Heat exchanger volume : Cylinder wall : Total volume 366

the pressure is the same in all four volumes. The efficiency will then be a function of heat exchanger temperatures, dead volumes and phase angle. The efficiency will also be a function of the heat transfer between gas and wall in the two cylinder volumes. The consequence of the simplifications is that the only losses compared to the ideal stirling cycle are due to the non isothermal cylinder volumes. If the wall temperature in the cylinder volumes is specified identical to the temperatures in the respective heat exchangers and the NTU-number in the cylinder volumes approaches infinity, the efficiency will approach the Carnot efficiency, and heat and work will approach the values calculated from the Schmidt analysis. If data from a real engine or refrigerator are used, the regenerator dead volume must be divided into two volumes, which are added to the hot and cold heat exchanger dead volumes respectively. The division must be made so that the volume and mass of gas in the regenerator are unchanged. The mass, temperature and pressure of the gas in the four volumes are calculated from the first law of thermodynamics and the law of continuity by means of a computer program which solves the differential equations. Heat and work are found by integration, and the overall error can be checked from the energy balance. 3. DIMENSIONLESS GROUPS In order to make the results more general, the variables are made dimensionless. The expansion space swept volume V, and heat exchanger temperature TE are used as a reference. The total mass of gas Mtot is also used as a reference. The main advantaae is that the number of variables is reduced considerably: The dimensionless input and output variables to the computer program are defined below. INPUT VARIABLES: Temperature: Temperature ratio: T = TJT, Cylinder wall, expansion space: T~~ = T,JfE Cylinder wall, compression space: T, = T&, Volume: Volume ratio: = compression space swept volume expansion space swept volume Expansion space dead volume: v, = V,No Compression space dead volume: v, = V,N0 Isothermal heat exchanger volume, expansion: VtE = v,/v, Isothermal heat exchanger volume, compression: v, = V)Jv Other variables: Number of transfer units, expansion cylinder: NTU, Number of transfer units, compression cylinder: NTU, Phase angle : 0 Heat capacity ratio: k = cjcv OUTPUT V 0 Pressure: p = P n R T tot E work: w = n R T tot E Heat: 9 = n R T tot E Dimensionless expansion volume: = Oa5 (' - cos ' W Q The variable volumes are expressed by the following Dimensionless compression volume: V, = 0.5 f (1 - WS(U - 0)) +, V The NTU-number is defined from the following - equation: h51 NTU - m c P The NTU-number has been used instead of h 4 as a parameter for several reasons. Normally the NTU-number is related to heat exchangers, but if the heat transfer in the cylinder volumes is increased considerably, it is necessary to design the cylinder volumes as a heat exchanger. The mass flow rate into and out of the cylinder volume will then be important for the heat transfer. Another reason is that a large and constant value of heat transfer causes numerical problems when the mass of gas in the cylinder volume is small as in the top dead point. Furthermore, a comparison between results with constant NTU-number and constant h 4 shows that the difference is small. 4.STIRLING MACHINE REFERENCE DATA As the computer program runs fast even on a IBM AT type personal computer it is possible to investigate the influence 367

In real highperformance stirling machines, heat exchange between the working gas and the walls in the cylinder volumes is insufficient to transport the heat between the working gas and the surroundings. Therefore, heat exchangers.are added between the cylinder volumes and the regenerator as shown in figure 1 b. VHC VOC QE QC Figure 2: Simplified stirling machine cycle for the analysis. 2.THE SIMPLIFIED STIRLING MACHINE In order to calculate the maximum possible efficiency and work, the stirling engine or refrigerator is simplified, so that it only consists of two variable cylinder volumes and two isothermal heat exchanger volumes as shown in figure 2. The isothermal heat exchanger volumes are separated by a regenerator without internal volume. The following assumptions are made: Figure 1: Stirling machine consisting of a) two variable cylinder volumes separated by a regenerator and b) with two heat exchangers included. As a consequence of the poor heat transfer in the cylinder volumes in high performance stirling machines, the cylinder volumes are nearly adiabatic instead of isothermal. Therefore the maximum obtainable efficiency is lower for the stirling cycle, even if all losses are assumed zero. The smaller the temperature difference between the heat sink and heat source is, the larger the reduction in efficiency will be compared to the Carnot efficiency. For stirling based refrigerators, which have been discussed recently as an alternative to refrigerators using CFC-gases, the maximum obtainable coefficient of performance (COP) is important. In a refrigerator the temperature difference between heat sink and source are small compared to an engine, and the penalty from adiabatic cylinder volumes becomes unacceptable. Therefore it is important, especially for stirling refrigerators, to investigate the possibilities for increasing heat transfer in the cylinder volumes in order to improve the actual cycle towards the ideal isothermal stirling cycle. The isothermal process raises the question of isothermalizers as discussed by C.D. West [I] and W.R. Martini [2], who both look at a specific stirling engine. Their conclusions are very different, and a further discussion is necessary. In this paper a dimensionless generalized investigation is made in order to calculate the maximum possible efficiency and work for the basic stirling cycle. Infinite heat transfer in the two heat exchangers, so that the temperature difference between the gas and the wall in the heat exchangers is zero, which means that the gas in the heat exchangers has the same temperatures as the heat sink and source respectively. The regenerator between the two heat exchangers has no internal volume. Infinite heat transfer in the regenerator, so that heat losses are zero, which means that the gas flows into the regenerator with the temperature identical to one heat exchanger and flows immediately out in the other end with a gas temperature identical to the other heat exchanger. Perfect mixing of gas in the two variable cylinder volumes. Heat exchange between working gas and wall in the two cylinder volumes takes place at a constant NTU-number. The cylinder wall temperatures TwE and T, are specified separately. Flow losses in heat exchangers and regenerator are assumed zero. Frictional losses are eliminated. The working gas acts as a perfect gas with c, and c, independent of temperature. Sinusoidal variation of the two cylinder volumes. The assumptions result in a momentary change in gas temperature when the gas flows between the heat exchangers and the cylinder volumes and from one heat exchanger through the regenerator to the other heat exchanger. Also 368

of a large number of parameters on output and efficiency. However, because of lack of space only the most important results are shown here. A set of reference data has been used. These data are based on common practice for stirling machines, except for the refrigerator phase angle, which is chosen as a compromise between cooling effect and efficiency: Temperature ratio, engine: T = 0.33 refrigerator:, f = 1.18 Heat capacity ratio: k = 1.4 Volume ratio: v = 1.0 Expansion space dead volume: v, = 0.05 Compression space dead volume:, v = 0.05 Isothermal heat exchanger volume, expansion: v, = 0.5 Isothermal heat exchanger volume, compression: v, = 0.5 Phase angle, engine: 0 = 120" refrigerator: 0 = 145" The results are calculated as a function of the NTU-number, which has the same value in the compression and expansion cylinder volumes. The engine specifications corresponds to a heater temperature at 700 C and a cooler temperature at 50 C, and the pressure ratio is approximately 2.0. The refrigerator temperature ratio corresponds to a hot end temperature at 40 C and a cold end temperature at -8 C. Hydrogen and air has a heat capacity ratio of 1.4, while helium have 1.67. tain the cylinder wall temperatures TWE and T, identical to the respective heat exchanger temperatures TE and T,. As a consequence of B) there will be a temporary heat transfer between gas and cylinder wall as illustrated in figure 2 by Q'wE and Q',, but the net heat transfer Q, and Q, over a cycle is zero. Most high performance stirling engines are very close to B), as the cylinder volumes are separated from the heat exchangers. As it is difficult to design the pistons in a stirling machine as a part of the heat exchangers, the surface of the piston, which is a part of the cylinder volume, will always act as case B). When the NTU-number is zero, the two cases are identical. When the NTU-number approaches infinity the efficiency for type A) approaches the Carnot-efficiency and the work approaches the value calculated from the Schmidt analysis. For the type 6) machine the gas temperature will be isothermal when the NTU-number approaches infinity, but the efficiency will not approach the Carnot-efficiency, as the gas temperature is different, when it flows into and out of the cylinder volume. In figure 3 the COP relative to the COP, and the dimensionless cooling rate are shown as a function of the cylinder wall NTU-number for a stirling refrigerator. From the figure is seen that the COP'S are identical for the type A) and type 6) refrigerator with adiabatic cylinder volumes (NTU = 0). 0.80 4 5. THE EFFECT OF "ISOTHERMALIZERS" According to the discussion about the influence of "isothermalizers", two different cases are first discussed. The two cases are: A) Cylinder wall temperatures TWE and, T, are identical to the expansion and compression space heat exchanger temperatures T, and T, respectively. For increased NTU-number in the cylinder volumes, the cylinder wall will take care of a part of the heat exchange between the gas and the surroundings. 8) Cylinder wall temperatures, T, and, T, are calculated, so that net heat transfer between the gas in the cylinder volumes and the surroundings is zero for a complete cycle. For increased NTU-number the cylinder volumes will be more isothermal, but they will NOT take care of any heat exchange between the gas and the surroundings. In both cases the wall temperature T, is constant over the cycle. Only the gas temperature in the cylinder volume changes periodically. The consequence of A) is, that the cylinder volumes must be made as a part of the heat exchanger in order to main- 0.00 I.... I.,. 11...1.. a.. '..,..1..1..1..1..1..1... 0.09 0.001 0.01 0.1 1 10 100 1000 NTU -num ber Figure 3. COP/COP, and dimensionless cooling rate as a function of the cylinder wall NTU-number for a stirling refrigerator. When the NTU-number is increased the COP DECREA- SES. For a further increase in the NTU-number, the COP for the type A) refrigerator approaches COP,. For the type B) refrigerator COP decreases below 50% of the COP,. When the NTU-number approaches infinity, the COP only increases to a value close to the value for adiabatic cylinders. The cooling rate decreases for increasing NTU-number. A minimum is obtained between 10 and 100, but the cooling a 369

rate for large NTU-numbers is 10% to 15% lower than for the adiabatic refrigerator with NTU = 0. Figure 4 shows the efficiency relative to the Carnot efficiency and the dimensionless work as a function of the NTUnumber for a stirling engine. The same tendency is observed as for the refrigerator, except that the difference between the type A) and the type B) machine is smaller, because of the larger temperature difference between hot and cold space. There is a significant minimum for efficiency and work, and the type B) engine has 10% - 20% lower efficiency and work pr. cycle compared to the type A) engine for large NTU-numbers. For other stirling machine specifications the results are varying, but the tendency is the same. It can therefore be concluded, that "isothermalizers", which are NOT integrated with the heat exchangers will decrease efficiency and work pr. cycle. 6. GENERAL RESULTS As the most favorable results are found for the type A) cylinder volume model, this model is used for the parametric variation. Only results for different temperature ratios T are shown here because of lack of space. The results can be used as a reference for maximum possible efficiency and output. 0 1.oo 0.00 a 0 0.60 0 \ a 0.40, 0.20 1-00 -! 0.80 [o.lo 9 0.60 I '0.40 1 0.00 4.... I...... I.... I...I.,...I...,.....I. B $ 3 0.08 3...J 0.06 o.ob1 6.07 0:r 1 10 100 1000 NTU - n urn ber Figure 4. Efficiency/Carnot-efficiency and dimensionless work as a function of the NTU-number for a stirling engine. If "isothermalizers" are to be used, they must be very effective, since the results here indicates that for typical heat transfer conditions they will, in fact, lower efficiency. If isothermalizers are introduced into a specific design with efficient heat exchangers the work pr. cycle will, normally, be decreased. The results agree with results from C.D. West as described in [l]. Of course the present results are only valid for stirling machines with external heat exchangers. If there are no external heat exchangers, the heat must be transferred in the cylinder volumes, or the cycle will fail. That is a part of the problem, when the results are compared to the results of W.R. Martini as described in [2]. Here there are no external heat exchangers, and when the heat transfer in the cylinder volumes decreases, the rege nerator has to act as a sort of heat exchanger. The validity of the results is therefore limited to stirling engines with heat transfer in the cylinder volumes instead of in separate heat exchangers and can not be compared to the results here and in [l]. I 0.00.001 0 0.01 00.1 1. 10 100 0 1000, NTU - n um ber Figure 5. Stirling refrigerator COP/COP, and cooling effect qe as a function of the NTU-number at four different temperature ratios A: 1.10. B: 1.18, C: 1.28, D: 1.42. Figure 5 contains results for the stirling refrigerator as described previously. The figure shows COP/COP-Carnot and dimensionless cooling rate qe as a function of the NTUnumber in the cylinder volume at four different temperature ratios. Figure 6 contains results for the stirling engine as described previously. The figure shows relative efficiency "P, and dimensionless work as a function of the NTU-number in the cylinder volumes at four different temperature ratios. If the NTU-number for the heat transfer in the cylinder volume is compared to the heat transfer in a heat exchanger, the following considerations can be made: C 2/3 P h = (St Pr ) m - 2/3 A Pr f This equation is introduced in the NTU-number expression: 2/3 A h A (St Pr ) h h NTU = - = - A 2/3 c m f Pr P 370

efficiency and work pr. cycle. 1.oo 0.12 D J- E T 0.80 A 0.00 :.."...,...I.1118.... I. - T >..I. 10.10 *.....,.... 0.06 0.001 0.01 0.1 1 10 100 1000 NTU-number Figure 6. Stirling engine efficiency "Pc and dimensionless work as a function of the NTU-number at four different temperature ratios A: 0.4, B: 0.37, C: 0.33, D: 0.28. Inserting the hydraulic diameter d, = 4 L AJA, we get: 2/3 L (St Pr ) NTU = 4 - d 2/3 h Pr t "lsothermalizers", which take part in the heat exchange between working gas and heat sink and source, must be very efficient, as they might otherwise decrease instead of increasing efficiency. The power per cycle will always be decreased compared to a machine with adiabatic cylinder volumes and efficient heat exchangers. It is also shown that it is very difficult to design a refrigerator based on the stirling cycle, which has a competitive COP compared to conventional CFC-based refrigerators. REFERENCES [l] C.D. West: Stirling Machines - Adiabatic to Isothermal, 3rd International Stirling En.gine Conference, 1986, ISEC 86-VI-67. [2] W.R. Martini: Investigation of the lsothermalization of the Hot and Cold Gas Spaces using Numerical Analysis, 3rd International Stirling Engine Conference, 1986, ISEC 86-VI 1-43. [3] W.M. Kays, A.L. London: Compact Heat Exchangers, McGraw-Hill Book Company, 1984. From [3] it is seen, that the St PrU3 is nearly always between 0.002 and 0.02. The Prandtl number for gases is approximately 0.7. A typical stirling heat exchanger has a Ud, = 50, which results in NTU-numbers between 0.5 and 5. For example, the cooler in the GPU-3 stirling engine has a NTU-number of 1.8. As it is more difficult to design a cylinder volume with efficient heat transfer than designing a heat exchanger, NTUnumbers in the cylinder volumes are likely to be below 5. It might therefore be wiser to insulate the cylinder volumes than making "isothermalizers". However, the results also show that a refrigerator with adiabatic cylinder volumes has a low COP compared to the Rankine cycle, which has a COP close to the Carnot cycle. That is despite a phase angle at 145", which gives a high COP but a low specific cooling rate. If a stirling based alternative to the CFC-based refrigerator is going to be competitive, efficient heat transfer in the cylinder volumes is necessary. 7. CONCLUSION An investigation based on a simplified stirling analysis of an idealized engine has been made. The only losses compared to the ideal stirling cycle are due to non isothermal cylinder volumes. The computer program based on the analysis can be used for the calculation of maximum possible efficiency and work for stirling refrigerators and engines. The results show, that "isothermalizers", which are NOT integrated with the heat exchangers, will always decrease 37 1