Australian/New Zealand EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZ. Cerc1ficace ofconfor1221t:y. Issue No.: 6 Date oflssue:

Similar documents
Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IT S WHAT S INSIDE THAT COUNTS

FLASHLIGHT ANSI STANDARDS

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IT S WHAT S INSIDE THAT COUNTS

of Conformity IECEx Gert f cate Test Safe

IECEx Certificate of Conformity

ALTAIR 5X Multigas Detector Product Specification

IECEx Certificate of Conformity

IECEx Certificate of Conformity

ALTAIR 2X Gas Detectors It s what s inside that really counts

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Australian/New Zealand Standard

altair 2X Gas Detectors

srra, of Conformity IECEx Gert f cate ?-ot,b

PERSONAL COMBUSTIBLE GAS DETECTOR

IECEx Certificate of Conformity

AS/NZS :2008

IECEx Certificate of Conformity

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IT S WHAT S INSIDE THAT COUNTS

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

IECEx Certificate of Conformity

Intrinsically Safe Solutions

FLASHLIGHT ANSI STANDARDS

IECEx Certificate of Conformity

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Intrinsically Safe or Explosionproof? Understanding the technology

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

IECEx Certificate of Conformity

Australian/New Zealand Standard

Australian/New Zealand Standard

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

AS/NZS IEC :2015

altair 2X Gas Detectors

IECEx Certificate of Conformity

Certificate of Compliance

Safe Operation Manual. Honeywell IQ Force Gas Detector

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Clip SGD. Portable single Gas Detector. User manual

IECEx Certificate of Conformity

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

AS/NZS IEC :2013

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

10yr O2NE & Safe-Ox. User Manual

IECEx Certificate of Conformity

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Inductive slot sensor

Control Panels Switchgear Motors Generators Analysers Rooms/Buildings. Pressurized Enclosure. Static Pressurization. Leakage Compensation (LC)

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Certification Supplement Manual

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Fixed Gas Detection System/Meridian CERTIFICATION

User s Manual YTA610 and YTA710 NEPSI Certification

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

TX6831 Data Sheet. Features. Benefits

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

AS/NZS :2011. Household and similar electrical appliances Safety AS/NZS :2011. Part 1: General requirements

Solar Separator Alarm Type Installation, Operation & Maintenance

IR25 Dual Gas Series Datasheet

AS/NZS :2014

Combustible Dusts What do I do???

slra IEC of Gonformity IECEx Cert f cate ü* t4

IECEx Certificate of Conformity

SenSmart Universal Gas Detector Series

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Guide to Intrinsically Safe Portable Radios

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

GasAlertMicroClip X3 Specifications

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

ALTAIR 5X Multigas Detector

Technical Data. Dimensions

14300 MAINS SEPARATOR ALARM MANUAL

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Single Gas Clip and SGC Plus User s Manual Rev 2.3

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

D Guard TM. Digital Guard Intrinsically Safe Intelligent Gas Detector. Part Number xxx. Manual Revision v2.09 (updated 20 April 2010)

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

ALTAIR 5X Multigas Detector

IR15 Dual Gas Series Datasheet

Transcription:

Australian/New Zealand Certtfic f on heme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZ Cerc1ficace ofconfor1221t:y Certificate ANZEx 06.34X Issue 0 Date oflssue: 2006-06-26 Issue 6 Date oflssue: 26-02-11 Applicant: Mine Safety Appliances Company, LLC 1000 Cranberry Woods Drive Cranberry Township PA 16066 United States of America Electrical Apparatus: Altair Pro Portable Single Gas Detector Type of Protection: Ex ia Marking Code: Ex ia IIC T4 (Ta= 50 C) Manufacturer: Mine Safety Appliances Company, LLC 1000 Cranberry Woods Drive Cranberry Township PA 16066 United States of America Manufacturing Location(s): As above The EPEE cer1ijicatio11 database located al l1ttp:llwww.aw;.ex.co111.a11 show lhe validity of this Certificate. Test I~ A u S T A A L I A Certificate Issued by: TestSafe Australia iz, I I 919 Londonderry Road, Londonderry NSW 2753 -T -, I Australia Phone: +61 2 4724 4900 Fax: +6124724 4999 http://www.testsafe.com.au l------!----j I www.jas-anz.org/register j EPF9_18 Pagel of6

Australian/New Zealand Certfftcatton Scheme for Cert-.ificace of Conform.icy Certificate ANZEx 06.34X Issue 0 Date of Issue: 2006-06-26 Issue 6 Date oflssue: 26-02-11 This certificate is granted subject to the conditions as set out in Standards Australia/Standards New Zealand Miscellaneous Publication MP87.1:2008. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0:21 IEC 60079-11:21 Explosive atmospheres - Part 0: Equipment- General requirements Explosive gas atmospheres - Part 11: Equipment protection by intrinsic safety 'i' This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standard(s) listed above. ASSESSMENT & TEST REPORTS: The equipment listed has successfully met the assessment and test requirements as recorded in: Test Report No. and Issuing Body: 35308, TestSafe Australia Quality Assessment Report No. and Issuing Body: FR/INE/QAR08.01/05, Ineris File Reference: 25/004372 Ujen Singh 11 February 26 Signed for and on behalf of issuing body Date of Issue Quality & Certification Manager Position This certificate is not transferable and remains the property of the issuing body and must be returned in the event of it being revoked or not renewed. EPFOl9 18 Page 2 of6

.:-..;.. Australian/New Zealand Certfflcatiom Cerl".ificat"e of Conform.icy- Certificate ANZEx 06.34X Issue 0 Date oflssue: 2006-06-26 Issue 6 Date oflssue: 26-02-11 Schedule EQUIPMENT: The "Altair Pro" portable single gas detector is initially available in three gas models e.g. 02, CO and H 2 S. The 0 2 model is called "Altair Pro 0 2 ". The gas sensing cells are of the electro-chemical type. The instrument is powered by a replaceable CR2 lithium cell. The LCD display panel on the front displays an indication of the level of the detected gas. A push button allows users to select the information viewed on the LCD display. Audible and visual alarm indicators are located on the front of the apparatus, and an imbalanced motor produces an optional vibration alert when in alarm mode. CONDITIONS OF CERTIFICATION: It is a condition of safe use that the lithium batteries of Panasonic CR-2PA/1B, Energizer CR2 EL1CR2BP, Varta CR2 6206 and Varta (Power One) CR2 CR15H270, 6206 shall be used in the apparatus. DOCUMENTS: Drawing/Document Pagels: Title: Revision Date: Level: (yyyy-mm-dd) SK3098-14 1 of7 Altair Pro Marking Details 00 2006-06-16 SK3098-14 2 of7 Altair Pro Assembly Details 00 2006-06-16 SK3098-l 4 3 of7 Schematic, Sin~le Gas, Altair Pro 00 2006-06-16 SK3098-14 sheet 4 of7 Altair Pro Parts List 00 2006-06-16 SK3098-14 & attachment B, SK3098-14 & attachment C, 5 of7 PCB Artwork, (Altair Pro PCB) (ref. & 10 10073836) 00 2006-06-16 sheets 5 of7 PCB Artwork, (Altair Pro 02 PCB) (ref. & 10 10066405) 00 2006-06-16 sheets SK3098-14 6 of7 Special Component Requirements 00 2006-06-16 SK3098-14 7 of7 Altair Pro Overview 00 2006-06-16 EPF9 18 Page 3 of6

Australian/New Zealand Certification Cerc.Lficace of Co.nfor.rn.1cy Certificate ANZEx 06.34X Issue 0 Date of Issue: 2006-06-26 Issue 6 Date oflssue: 26-02-11 Variations Permitted by Issue 1: Schedule of Variations ~ A new model "Altair Pro-R 02" Remote Oxygen Detector has been added. The "Altair Pro-R 02" remote oxygen detector is identical to the model "Altair Pro 0 2 ". The "Altair Pro-R 02" remote oxygen detector has a jack socket on the front panel where a remote oxygen detecting electrochemical cell is connected. Altair Pro-R 02 Remote Oxygen Detector has been assessed in Test Report 28538. Condition of Certification Relating to Issue 1: 1. It is a condition of safe use that the maximum length of the remote sensor connecting cable in the "Altair Pro-R 02" does not exceed 3.3 metres (10 feet). 2. All previous conditions are still applicable. Drawings Relating to Issue 1: Drawing/Document Pagels: Title: Revision Level: Date: (yyyy-mm-dd) SK3098-14 1 of9 Altair Pro Marking Details SK3098-14 2 of9 Altair Pro Assembly Details SK3098-14 3 of9 Schematic, Single Gas, Altair Pro SK3098-14 4 of9 Altair Pro Parts List SK3098-14 & 5 of9 PCB Artwork, (Altair Pro PCB) (ref. attachment 7 sheets 10075555) SK3098-14 6, 7 of Special Component Requirements 9 SK3098-14 8 of9 Altair Pro Overview SK3098-14 9 of9 Revision History EPFOl9_ 18 Page 4 of6

.;... Australian/New Zealand Certff catfon Scheme for- Cert-.ificat-e of Confor.rrdt-y Certificate ANZEx 06.34X Issue 0 Date of Issue: 2006-06-26 Issue 6 Date oflssue: 26-02-11 Variations Permitted by Issue 2: ~ Adding an alternate case overmould material RTP 2099E X 118617 B (Black) to the apparatus. This change has been assessed in Test Report 30309. Condition of Certification Relating to Issue 2: 1. Drawings Relating to Issue 2: Drawing/Document Pagels: Title: Revision Date: Level: (yyyy-mm-dd) SK3098-14 6 of9 Special Component Requirements 2 2008-05-06 Variations Permitted by Issue 3: ~ Capacitors C13, C14, C22 (0.1 µf 10% each) were added to the Altair Pro microcontroller reset circuit. ~ Capacitors Cl8, C19, C20 (0.1 µf 10% each) were added to the Altair Pro 02 microcontroller reset circuit. ~ An additional Transient Voltage Suppressor was added to the Altair Pro-R 02 version. ~ Added alternate static dissipative overmould material RTP2099 EX 118617 B (various colour) to the apparatus. This change has been assessed in Test Report 30856. Condition of Certification Relating to Issue 3: Drawings Relating to Issue 3: Drawing/Document Pagels: SK3098-14 9 Altair Pro TestSafe Title: Revision Level: 3 Date: (yyyy-mm-dd) 2008-11-06 Variations Permitted by Issue 4: ~ The QAR Issuer was changed from CSA to Ineris. Condition of Certification Relating to Issue 4: EPF9_18 Page 5 of6

Cerc.Lficace of Confor.rnLcy Certificate ANZEx 06.34X Issue 0 Date oflssue: 2006-06-26 Issue 6 Date oflssue: 26-02-11 Variations Permitted by Issue 5: 1. The IR Transceiver (component designator U2) Sharp GP2WO 11 OYPOF is being replaced by a similar device Vishay TFBS4650. 2. Associated capacitor CS decreased in nominal capacitance from 1.0 µf to O.lµF. 3. Protective resistor R3 previously 39.2 n, ± 1 % tolerance, 0.5 W rating, has changed to 100 n, ± 1 % tolerance, 0.5 W rating. This change has been assessed in Test Report 33788. Condition of Certification Relating to Issue 5: Drawings Relating to Issue 5: Drawing/Document Pagels: SK3098-14 28 Altair Pro TestSafe Title: Revision Date: Level: (yyyy-mm-dd) 4 22-05-18 Variations Permitted by Issue 6: The applicant and manufacturer name was changed from Mine Safety Appliances Co. to Mine Safety Appliances Company, LLC. Updated standards to IEC 60079-0:21 and IEC 60079-11:21. This change has been assessed in Test Report 35308. Condition of Certification Relating to Issue 6: Drawings Relating to Issue 6: Drawing/Document Pagels: SK3098-14 28 Altair Pro TestSafe Title: 10069170 3 Label, Approval, Altair Pro 10074734 47 Altair Pro Single Gas Detector Operating Manual Revision Level: 4 6 3 Date: (yyyy-mm-dd) 22-05-18 25-02-27 - EPF9_18 Page 6 of6