DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Similar documents
INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

DUAL OPTIC. Installation manual

INDEX. Installation recommendation

English. Italiano. Português. Françias. Español

CONFIGURATION OF THE OPTICALS

Description. Optex Incorporated

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

LUX Hardwired - Installation Notes

English. Series. Installation and Use Manual

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

INDEX. Installation recommendation

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

INDEX. Installation recommendation

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

INDICE. Installation recommendation

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Immunity. P/N: ver.b

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

DD205RF/TX Detector Installation Sheet

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

JUNE 2014 SECURITY SYSTEMS

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Advanced DIGITAL Wired PIR Motion Detector

D-Tect 2 GJD300 Quad PIR Movement Detector

Movement Detector GJD 300

PARVIS Safe and tranquil thanks to Parvis

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

SECURITY PRODUCTS CATALOGUE

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

"Pegaso" wireless alarm system

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Perimeter protection

MADE TO PROTECT OUTDOOR DUAL-TECH CURTAIN DETECTORS AGATE / AOCD-250

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Extended Range DUAL TEC Motion Sensor

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

General Description. Industrial LuNAR DT AM Grade 3 Features

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

HX-80NRAM. High Mount Outdoor Detector

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

D-TECT 3 IP. GJD260 IP Motion Detector

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Radar Sensor. Radar Security Detector Model No. : DND-30L/30W, DND-60L/60W, DND-90L/90W. Feature. Specification. Reference

INFRARED MODULATED BARRIERS

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Installation Instructions

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

High Frequency Sensor

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

SEPTEMBER SECURITY SYSTEMS REV.00

Installation Instructions

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

D-TECT 2 IP. GJD230 IP Motion Detector

Passive infrared ceiling sensor

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

BARRIERE & SENSORI BARRIERS & SENSORS

Installation And commissioning manual. Series S Double Beam 1/16

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

IP65 High Bay Dual Sense Sensor

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

SYSTEMS GROUP. May Zilog and EE-SGI Present. epir TM. The Next Generation of PIR Motion Detector Technology. (Over View)

Infrared Wall Mount Occupancy Sensor

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

Ceiling PIR HS presence detector. Product Guide. Overview. Features

180 Degree Ceiling Mounted Occupancy Sensors

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

FIRERAY 5000 range USER GUIDE

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Acusensor 3. Instruction Manual

"Pegaso" wireless alarm system D.I.Y. wireless kit

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Active Infrared Multi Beam Sensors

Transcription:

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

1. DESCRIPTION Dual Technology Sensor (PIR + Microwave). AND operation in the prevention of "false alarms". IP65 (indoor and outdoor). Mount directly to the wall or by "L" bracket. Sensibility adjustable PIR with angular aperture of about 6. Microwave K-band 24 GHz. IR range adjustable from 0 to 12m. MW range adjustable from 0 to 12m. Function and output ANTI-MASKING for infrared and microwave. High immunity to false alarms. RF immunity up to 2Ghz. Pet Immunity. Small size (135mm x 33mm x 40mm) Processing digital signals of PIR and MW. Security Function. Digital Filter 100Hz. Temperature Autocompensation. Environmental Autocompensation. Operativity Self scanning of PIR technology. Operativity Self scanning of MW technology. Tamper output combined anti- removal and anti-tear. Dip-Switch programming. Politec S.r.l. Man NAT Ver. 1.5 2

NAT MOTHERBOARD 1 4 2 5 3 6 7 8 9 12 10 11 13 14 1 POWER SUPPLY 2 3 4 5 6 ANTI-MASK (anti open collector negative) SBY (positive input) TAMPER (N.C. tamper output) ALARM (N.C. alarm output) TAMPER BUTTONS (anti-removal and anti-tear) 7 DIP SWITCHES 8 TRIMMER MW 9 TRIMMER IR 10 11 12 13 14 RED LED (ALARM) ORANGE LED (PIR) GREEN LED (MW) MICROWAVE 24GHZ PYROELECTRIC SENSOR 10-30 Vcc GND Pay attention to the polarity. Negative always opens in the event of masking. the system is inhibited if an + is connected It opens in case of sensor tampering. It opens in case of detection MW+IR. If they get open give the opening of N.C. System configuration. rotating in clockwise increases the range (sensibility) of MW. rotating in clockwise increases the range (sensibility) of IR. lit up when there is a general alarm, if enabled. lit up when there is a PIR alarm, if enabled. lit up when there is a Microwave alarm, if enabled. Detection sensor MW. Detection sensor IR. Politec S.r.l. Man NAT Ver. 1.5 3

2. MOUNTING The mounting of the NAT can occur in two modes or directly to the wall through the plate or "L" through the mounting bracket angular. WALL MOUNTING 1 3 2 5 4 6 1. Insert the shielded cable alarm in the fixing plate; 2. Fix the plate at wall ; 3. Drill hole in the rubber nut and slide inside the cable; 4. Screw the base on the plate; 5. Fix the NAT motherboard on the support base and connect wires; 6. After the wiring and operation test close NAT sure that the seals and the O-rings are present and not damaged to ensure the integrity of the product. Politec S.r.l. Man NAT Ver. 1.5 4

WALL MOUNT WITH L BRACKET 4 2 1 6 3 5 7 1. Insert the shielded alarm cable into the slots of the bracket angle and fasten it to the wall; 2. pass the cable through the mounting plate; 3. fix the plate to the fastening bracket angle; 4. Drill hole in the rubber nut and slide inside the cable; 5. Screw the base on the plate; 6. Fix the NAT motherboard on the support base and connect wires; 7. After the wiring and operation test close (7) NAT sure that the seals and the O-rings are present and not damaged to ensure the integrity of the product. Politec S.r.l. Man NAT Ver. 1.5 5

3. COVERAGE AREA SIDE VIEW VIEW FROM ABOVE NB: The system can also detect the areas underlying the sensor Nat adjusting the range (sensitivity) of the two technologies (see below). Politec S.r.l. Man NAT Ver. 1.5 6

4. PROGRAMMIN AND OPERATION Install the sensor Nat between 2 and 3 meters in height from the floor concerned following the instructions on page 4. Connect the power supply according to polarity (10-30V) and connect the outputs Alarm, Tamper and Anti-Mask in central according to their usage requirements. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 +/GND ANTI- MASK STAND- BY TMP ALARM Power supply of NAT 10/30Vdc. Open collector negative.opens in the event of masking. Positive input. the system is inhibited if an + is connected. N.C. Tamper output. It opens in case of sensor tampering. N.C. Alarm output. It opens in case of detection MW+IR. MW RANGE (SENSITIVITY) 1-12m REGULATION TRIMMER: Adjust the microwave range through the trimmer, implementing with crossing test. Submitting GREEN LED will help to verify the detection of the passage in different areas (exp. 0m, 4m, 7m, 12m). Test the goodness of the coverage of the affected areas, by adjusting the PIR. POWER LED ON FOR DETECTION TEST Turn on the dipswitch number 4 for the functionality of the LEDs detection. ON 1 2 3 4 Power on for the duration of about 30 seconds if the DIP4 of the LEDs is activated you will see an alternate flashing of these,for the stabilization of the system. Term of flashes you can proceed with the following settings. PIR RANGE (SENSITIVITY) 1-12m REGULATION TRIMMER: Adjust the PIR range through the trimmer, implementing with crossing test. Submitting ORANGE LED will help to verify the detection of the passage in different areas (exp. 0m, 4m, 7m, 12m). Test the goodness of the coverage of the affected areas, by adjusting the MW. Politec S.r.l. Man NAT Ver. 1.5 7

5. ADDITIONAL FEATURES FILTER DISTURBS Turn the DIP switch number 1 to filter and reduce noise at 100Hz. caused by external agents such as NEON lights. N.B.: Use this feature (reduced sensitivity) ONLY in the presence of such a source of disturbance in the extreme vicinity. Carry out a repetition of the MW range adjustment and test the goodness of the coverage of the affected areas by adjusting the PIR. ON 1 2 3 4 ANTI-MASK Turn the dipswitch number 2 for the functionality ANTI-MASK. Activating this function when an object is placed in front of the sensor to blind it and make it ineffective, an active infrared system checks for the presence of these in 3 seconds and gives an output signal through dedicated. The anti-mask microwave verification of the presence of an object check in 20 seconds the presence of an object and gives an output dedicated. N.B.: If DIP 2 (anti-mask) and 4 (LED) are activated when it comes in a stealth mode, led blinking greenorange alert the opening of the contact ANTI-MASK. WARNING: When activated the DIP 2 before leaving the installation spot, you MUST close the sensor NAT and you MUST power down and power up the entire system. ON 1 2 3 4 SECURITY FUNCTION Turn the dipswitch number 3 functionality SECURITY. Activating this function if the MW sensor provides at least 7 distinct surveys in 30 seconds, the alarm signal from a system independently of the PIR sensor readings. Dually the IR sensor provides at least 4 separate surveys in 30 seconds, the system by an alarm signal regardless of the sensor readings MW. ON 1 2 3 4 When the test and programming are ended turn off the LED settings provide to secure the cover. Politec S.r.l. Man NAT Ver. 1.5 8

6. DESCRIPTION OF NOT SETTABLE FUNCTION PET IMMUNITY SYSTEM The system of pet immunity is able to discriminate the small animals up to a maximum of 10kg and not to give an alarm signal. In the case of animals such as dogs and cats perform function tests. SELF-DIAGNOSIS SYSTEM The system will periodically check every 50sec about the functionality of the microwave and PIR system. In case of Malfunction of one of the two detection equipment, this is signaled by the flashing of the LED dedicated (GREEN and ORANGE for MW for IR), steadily. In this condition the system excludes the operation of the technology is not working and the detection will continue to be present in the OR mode. AUTO-THERMAL SYSTEM The system detects the temperature of the surrounding environment through a dedicated sensor and modify the detection parameters of the IR sensor in order to adapt to extreme environmental conditions. AUTO-ENVIRONMENTAL SYSTEM The system locates in the case of heavy rains and snowfall an environmental condition "different" after about 20 seconds and is able to adapt the system to the detection threshold by changing the parameters of both technologies for the duration of the event. Politec S.r.l. Man NAT Ver. 1.5 9

7. APPLICATION Example 1: "wall covering" The sensor can be commonly used for the protection of facades using the bracket to "L", and thanks to the new system of AUTO-ENVIRONMENTAL is able to reduce to zero the possibility of "false alarms". The installation MUST be carried out at height between 2 and 3m by adjusting the range and sensitivity of the two technologies (MW + IR). Example 2: Curtain for windows or doors Politec S.r.l. Man NAT Ver. 1.5 10

8. TECNICAL SPECIFICATION Description Value Max range detection IR Adjustable 1-12m Max range detection MW Adjustable 1-12m MW Frequency / 24.125Ghz Angle IR coverage / 80 vertical 6 horizontal Angle MW coverage / 80 vertical 30 horizontal Power supply / 10 30 Vdc Absorption on alarm / 42mA Absorption standby / 40mA Alarm Output N.C. / Tamper Output N.C. / Max range detection IR Open collector - / Stand-by input INPUT + / Operating Temperature -20 +65 C Dimensions 135mm X 33mm X 40mm Weight 150gr Mounting brackets TOTAL WARRANTY 2 YEARS Politec S.r.l. Man NAT Ver. 1.5 11

Politec S.r.l. Man NAT Ver. 1.5 12