AIR TO AIR HEAT EXCHANGERS

Similar documents
Installation, Operation, and Maintenance Information

ENCLOSURE COOLING. Glossary

Service Parts for RMR Wall-Mount Enclosures

SEALED ENCLOSURE COOLING

NOREN Products. Compact Cabinet Coolers

Precise Temperature Control; Compact Footprint

RACK-MOUNT Air Conditioners

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

GENESIS Indoor Air Conditioners

Thermal Management INDEX. Management. Thermal TM-1

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

SPECTRACOOL Indoor & Outdoor Air Conditioners

Quality Enclosures. Service Excellence.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

T P A 120 S 4 S N 1 Y

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

HYBRID ADIABATIC Cooling System

Cabinet Cooler Systems

CIRRUS AIRPLANE MAINTENANCE MANUAL

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

SPECTRACOOL Indoor & Outdoor Air Conditioners

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

VA G 052 S

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

The Technology of Modern Filtration KRAD. Compressed Air Dryer with integrated compressed air filters

2 shp 13 lc 1 36 t - 1 a

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

THE ULTIMATE GUIDE TO ENCLOSURE COOLING FOR WATER TREATMENT. The Ultimate Guide to Enclosure Cooling for Water Treatment

Owners Manual Refrigerated Air Dryer MHT SERIES

Gate Operator. Modfications

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

NQ Series Portable Chillers

LQ AQ SQ. Air-cooled and water-cooled portable chillers

FX5 Series Explosion-Proof Electric Air Heaters

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

OACS Outdoor Air-Cooled Central Chillers

Powers Controls Low Temperature Detection Thermostat

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SECTION 50 - CAB CLIMATE CONTROL

HIGH EFFICIENCY AIR HANDLER

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

PROAIR Harsh Environment/Wash Down Air Conditioners

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

REFRIGERATED AIR DRYERS

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

D E F E N D E R Datacom Cabinets

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

Portable Vertical Air-Conditioning and Heating Systems

AC-162 Peltier-Thermoelectric Air Cooler

Gas-Fired Double-Effect Chiller-Heater

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

ShuttleAIRE Systems. A complete range of HVAC systems for small and medium sized vehicles.

1998 Expedition/Navigator Workshop Manual

MECHANICAL SCIENCE Module 2 Heat Exchangers

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Guide To Troubleshooting INEFFICIENT COOLING FANS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

LQ AQ SQ. Air-cooled and water-cooled portable chillers

THRU-THE-WALL AIR CONDITIONERS

.2 Section Waste Management and Disposal.

Thermostat KPU. Data sheet

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

SPECTRACOOL INDOOR/OUTDOOR

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

50TM TFF COMBINATION HEATING/COOLING UNITS

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required

Dual Tower Heat Reactivated Desiccant Air Dryer

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

50TM COMBINATION HEATING/COOLING UNITS

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

SECTION AIR COMPRESSORS AND ACCESSORIES

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Climate Control System

Thermal management of electrical enclosures. Stronger than the elements. Pfannenberg units for outdoor thermal management.

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

5736 N. Michigan Road Indianapolis, IN 46228

COOLING FOR ELECTRONIC PROCESS CONTROL SYSTEMS IN HOSTILE FACTORY ENVIRONMENTS

Transcription:

AIR TO AIR HEAT EXCHANGERS HEAT PIPE TECHNOLOGY CLOSED LOOP DESIGN AVAILABLE IN 120, 230, 24VDC & 48VDC NEMA TYPE 12, 4 AND 4X UL LISTED FOR STANDARD AND HAZARDOUS LOCATIONS

A2A SERIES AIR TO AIR HEAT EXCHANGERS THERMAL EDGE AIR TO AIR HEAT EXCHANGER The Thermal Edge Air to Air Heat Exchanger is a closed loop cooling system which employs the heat pipe principle to exchange heat from an electrical enclosure to the outside. Where ambient temperatures are suitable for heat pipes, they are the most efficient method of cooling as the waste heat is the engine which drives the system. The only power requirement is to operate two circulating fans or blowers. Heat pipes have a liquid refrigerant under a partial vacuum inside sealed tubes. They operate with a phase change process which is much like that of mechanical air conditioning, but without the compressor. The heat pipes are assembled with finned evaporator and condenser sections which are separated by a sealed baffle so as to provide a closed loop. The lower section of the heat pipe assembly is in contact with heated air from the electrical enclosure. The heat causes the refrigerant to change phase (vaporize). The vapor flashes (at the speed of sound) to the top of the pipe which is in contact with the outside (ambient) air. When the outside air temperature is lower than the enclosure temperature, the refrigerant vapor gives up heat to the outside air and returns to the liquid phase. The liquid falls to the bottom and repeats the cycle endlessly, so long as there is a negative temperature differential between the outside air and the enclosure. Heat pipes will not operate in reverse cycle so heat cannot be transferred from the ambient to the interior of the enclosure. The Thermal Edge design has a top-to-bottom enclosure air flow pattern with maximum separation of the inlet and outlet. This design pulls the hottest air from the top of the enclosure and returns the cooled air from the bottom of the heat pipe to the enclosure. The air flow on the ambient side is bottom in, top out, so that the hotter discharge air moves up and away rather than being recirculated. As with all of our coil systems, we use aluminum end plates and baffles which improve conduction and reduce corrosion for longer life. The center aluminum baffle, which is swedged into the heat pipe coil, provides an air tight seal between the two air systems. Outside Air Inside Air

A2A SERIES- AIR TO AIR HEAT EXCHANGERS All units are available in NEMA Types 12, 4 and 4X Coated coils standard with NEMA Types 4 and 4X Hazardous Location Optional Model Body Style Watts/ C Watts/ F Voltage/Hz. Running Amps Maximum Operating Temperature H x W x D Weight (lbs.) Unit / Ship A2AC040120 Compact 11 6 120 50/60.37 149 F 16.5 x 11 x 3.5 16 / 18 A2AC040230 Compact 11 6 230 50/60.18 149 F 16.5 x 11 x 3.5 16 / 18 A2AC040D24 Compact 11 6 24VDC.80 149 F 16.5 x 11 x 3.5 16 / 18 A2AC080120 Compact 22 12 120 50/60.37 149 F 16.5 x 11 x 3.5 16 / 18 A2AC080230 Compact 22 12 230 50/60.18 149 F 16.5 x 11 x 3.5 16 / 18 A2AC080D24 Compact 22 12 24VDC.80 149 F 16.5 x 11 x 3.5 16 / 18 A2AD120120 Deep 33 18 120 50/60.37 149 F 16.5 x 11 x 5.5 20 / 22 A2AD120230 Deep 33 18 230 50/60.18 149 F 16.5 x 11 x 5.5 20 / 22 A2AD120D24 Deep 33 18 24VDC.80 149 F 16.5 x 11 x 5.5 20 / 22 A2AD120D48 Deep 33 18 48VDC.40 149 F 16.5 x 11 x 5.5 20 / 22 A2AD160120 Deep 44 24 120 50/60.37 149 F 16.5 x 11 x 5.5 20 / 22 A2AD160230 Deep 44 24 230 50/60.18 149 F 16.5 x 11 x 5.5 20 / 22 A2AD160D24 Deep 44 24 24VDC.80 149 F 16.5 x 11 x 5.5 20 / 22 A2AD160D48 Deep 44 24 48VDC.40 149 F 16.5 x 11 x 5.5 20 / 22 A2AT200120 Tall 55 31 120 50/60.47 160 F 29 x 13.88 x 5.5 34 / 36 A2AT200230 Tall 55 31 230 50/60.243 160 F 29 x 13.88 x 5.5 34 / 36 A2AT200D24 Tall 55 31 24VDC 1.94 160 F 29 x 13.88 x 5.5 34 / 36 A2AT200D48 Tall 55 31 48VDC.928 160 F 29 x 13.88 x 5.5 34 / 36 A2AT260120 Tall 71.6 40 120 50/60.47 160 F 29 x 13.88 x 5.5 34 / 36 A2AT260230 Tall 71.6 40 230 50/60.243 160 F 29 x 13.88 x 5.5 34 / 36 A2AT260D24 Tall 71.6 40 24VDC 1.94 160 F 29 x 13.88 x 5.5 34 / 36 A2AT260D48 Tall 71.6 40 48VDC.928 160 F 29 x 13.88 x 5.5 34 / 36 Due to design and part development, all information is subject to change

COMPACT SERIES DEEP SERIES Due to design and part development, all information is subject to change

TALL SERIES Due to design and part development, all information is subject to change

Components are Failing inside electrical enclosures when using Filtered Fan Packages FACT: FILTERED FANS INTRODUCE DIRT AND CONTAMINATION INTO EVERY ELECTRICAL ENCLOSURE USING THEM FACT: DRIVES AND PLCS DO NOT LIKE DIRT, DUST AND CONTAMINATION FACT: FILTERED FANS CAN NEVER PRODUCE A TRUE CLOSED LOOP COOLING SOLUTION FACT: NO MATTER HOW EFFECTIVE YOUR FILTER IS, DIRT AND PARTICULATES WILL ENTER YOUR ENCLOSURE CONSIDER A BETTER SOLUTION - AIR TO AIR HEAT EXCHANGER: ALWAYS CLOSED LOOP LOW COST AND MAINTENANCE FREE EASIER TO MOUNT ON ONLY ONE SIDE OF YOUR ENCLOSURE ENERGY EFFICIENT, USING NO MORE POWER THAN A FILTERED FAN SYSTEM FILTER FREE, SO NO DIMINISHED COOLING CAPACITY. AIR TO AIR HEAT EXCHANGERS ARE AVAILABLE IN NEMA TYPES 12, 4 AND 4X In this image, a standard installation shows where the dirt and particulate will enter the enclosure and be pulled in by the fans on your drives and devices. Filters or not, contamination is invited in by this open loop approach. In this image, a standard installation demonstrates the closed loop condition maintained by the Air to Air Heat Exchanger. Cool air inlet and outlet vents are completely covered by the heat exchanger. This provides NEMA Type 12, 4 or 4X. Contact Us Today to Remove Heat Issues in your Electrical Enclosures!! Phone: 1-888-580-0202 E-mail: thermalinfo@thermal-edge.com UL File # 33288 Under UL standard 1995 All information subject to change without notice A2A Product Sheet 2017-11-02