RF one-step BNC/TNC connectors for coaxial cable termination

Similar documents
8Electrical Interconnect Products

SolderSleeve Shield Terminators

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Single Wall Tubing CGPE-105. Brightly Colored, Shiny, Non-Flame-Retardant Polyolefin Tubing. Product Facts

Weight / 003 -Z M5 (SUCOFEED ¼ HF) bulk 10 pcs g / 5.25 oz.

PolySwitch TS600 Overcurrent Protection Devices

Z-PACK TinMan 85 ohm Connector Overview

Gardian W51. Approvals

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

DTS SERIES CONNECTORS

Installation Procedure and Inspection Criteria for SolderSleeve Coaxial Cable Terminators on Coaxial Cables Rated For At Least 125 C.

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Gas Discharge Tubes GTCX28-XXXM-R05 Series

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Gas Discharge Tubes GTCX25-XXXM-R02 Series

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

Cable Actuated Sensor Industrial Incremental Encoder Output

PT9420 (Extended Range)

S200 SHIELD TERMINATORS


C Electrical Connection Kit

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

Installation Procedure for D-200 series Shielded Cable Splice Kits with MiniSeal Crimp Primary Splices

QUADRAX D-SUB CONNECTORS

Industrial Strength Leak Detection

M7100 Pressure Transducer

C A Heating Cable Gland Kit

Seal Kits for BUDI Enclosures

DATASHEET PolySwitch RKEF Devices

RayClic Connection System

TE Connectivity's AMP NETCONNECT Cable Management

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

OPERATION MANUAL Model 8011 & mA

DP86 Constant Voltage with Fitting

Telecom Fuses. Benefits. Features. Applications

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

PT9600. Cable Actuated Encoder Reel. General. Environmental

MODEL 4000A & 4001A ACCELEROMETER

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

U5600. Wireless Pressure Transducer SPECIFICATIONS

Cable Actuated Sensor Industrial User Scalable VDC Output

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

AquiTron. AT-WM Water Monitor DATA SHEET

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Standard SPECIFICATIONS FEATURES APPLICATIONS

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Mar11 Rev C

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

C910 Series. Single-point heat-tracing control system

Cable Actuated Sensor Industrial User Scalable 4 20mA

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

D5100 Industrial Differential Pressure Transducer

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

M5200 Industrial Pressure Transducer

MODEL 834M1 ACCELEROMETER

Your Pick... One Solution

Raychem Link Boxes. Cable Services Limited. Powering the UK

OPERATION MANUAL MODEL 4610 ACCELEROMETER

U5300 Industrial Pressure Transducer

PT9150 (Extended Range)

TraceTek TT1000 Modular Sensing Cable

QuickStat-TC Installation & Operation Manual

LOW PRESSURE Intrinsically Safe Transducer AST44LP

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

SolderSleeve Insulated Electrical Termination Devices

This document provides assistance with the selection of elements of the C5C copper pairs connection system. It includes the following sections:

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Jun08 Rev C

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

M5800 Pressure Transducer with Rotatable Display

P125 High Pressure Sensor

Gas Discharge Tubes. Features: Benefits: Applications:

Industrial Strength Leak Detection

HVS S 15kV Class

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Kabelkatalog.indd. Spectrum Elektrotechnik GmbH Fax: Phone:

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

OPERATION MANUAL MODEL & ACCELEROMETER

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

OPERATION MANUAL MODEL 805 ACCELEROMETER

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

D5100 Industrial Differential Pressure Transducer

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

M5800 Pressure Transducer with Rotatable Display

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

ELAF LOAD CELL SPECIFICATIONS FEATURES

Raychem Heating System

Jan05 Rev A EC

OPERATION MANUAL MODEL 3038 ACCELEROMETER

Transcription:

Easy, quick installation Outstanding cable-retention force Solder-solder connection type (center conductor and braid) RF one-step BNC/TNC connectors for coaxial cable termination Applications RF one-step BNC/TNC connectors are single-piece assemblies for terminating the center conductor and the braid of a broad range of coaxial cables. The connectors are fully intermateable with MIL-C-39012 connectors and are available in 50-ohm and 75-ohm versions. Features/Benefits One-step termination for easy, quick installation and lower installed cost. Exceptional cable retention force to withstand high vibration and frequent mates and demates. Fully soldered center conductor and braid. Excellent built-in strain relief against vibration and excessive handling. Long-term reliability. Controlled soldering termination. Use with standard RG/U cables and Raychem Cheminax cables. Three product sizes to accommodate a wide range of cables. Meets performance requirements of MIL-C-39012 up to 2.8 GHz. Product Options and Dimensions (mm/in) BNC TNC Contact/cable transition (male or female see part number selection table) Fig. 1 24.5 max. (.965) Fig. 6 24.5 max. (.965) Fig. 2 Rightangle 28.0 (1.09) 31.5 max. (1.23) Fig. 7 Rightangle 28.0 (1.09) 33.5 max. (1.32) Fig. 3 bulkhead Fig. 8 bulkhead Fig. 4 Fig. 9 Fig. 5 panel 4 x M2.5 x 0.45 Fig. 10 panel 4 x M2.5 x 0.45

Part Selection Process 1. From Product Options and Dimensions on the first page, select the connector style you need (BNC or TNC, or, male or female contacts) and note the Figure number of the style you selected. 2. From the tables that follow, find the appropriate table for the connector style and Figure you selected. 3. From the appropriate table, select the connector part number based on the RG cable type or Raychem cable part number. For cable types not shown use the cable dimensions. D E F G Note: The cable dimensions in each table are keyed to the diagram on the right. Part Number Selection BNC Coaxial Connectors (ohms) RG cables Raychem cables (min. max.) (min. max.) (max.) (max.) Part Number BNC straight s, male contacts (Figure 1) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RBD-50-S-00 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RBD-50-M-00 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RBD-50-L-00 (.060.217) (.035.118) (.060) (.025) RBD-75-S-00 (.138.276) (.083.197) (.118) (.050) RBD-75-M-00 75 RG-6, RG-11, RG-12, RG-59 5.0.12.5 4.1 9.5 7.3 2.45 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RBD-75-L-00 BNC right-angle s, male contacts (Figure 2) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RBD-50-S-01 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RBD-50-M-01 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RBD-50-L-01 (.060.217) (.035.118) (.060) (.025) RBD-75-S-01 (.138.276) (.083.197) (.118) (.050) RBD-75-M-01 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RBD-75-L-01

TNC Coaxial Connectors (ohms) RG cables Raychem cables (min. max.) (min. max.) (max.) (max.) Part number TNC straight s, Female contacts (Figure 9) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RTD-50-S-03 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RTD-50-M-03 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RTD-50-L-03 (.060.217) (.035.118) (.060) (.025) RTD-75-S-03 (.138.276) (.083.197) (.118) (.050) RTD-75-M-03 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RTD-75-L-03 TNC straight panel s, female contacts (Figure 10) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RTD-50-S-04 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RTD-50-M-04 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RTD-50-L-04 (.060.217) (.035.118) (.060) (.025) RTD-75-S-04 (.138.276) (.083.197) (.118) (.050) RTD-75-M-04 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RTD-75-L-04 Hole pattern for panel-mounted products (mm/in) Panel thickness: 3.2 (.125) max. RBD-XX-X-04 RTD-XX-X-04 RBD-XX-X -02 RTD-XX-X -02 12.7 (.5) 12 (.47) 20.5 (.8) min. 12.7 (.5) 11.2 (.44) 3 (.12) 18 (.7) min. 12.9 (.51)

BNC Coaxial Connectors (ohms) RG cables Raychem cables (min. max.) (min. max.) (max.) (max.) Part number BNC straight bulkhead s, female contacts (Figure 3) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RBD-50-S-02 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RBD-50-M-02 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RBD-50-L-02 (.060.217) (.035.118) (.060) (.025) RBD-75-S-02 (.138.276) (.083.197) (.118) (.050) RBD-75-M-02 75 RG-6, RG-11, RG-12, RG-59 5.0-12.5 4.1 9.5 7.3 2.45 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RBD-75-L-02 BNC straight s, female contacts (Figure 4) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RBD-50-S-03 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RBD-50-M-03 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RBD-50-L-03 (.060.217) (.035.118) (.060) (.025) RBD-75-S-03 (.138.276) (.083.197) (.118) (.050) RBD-75-M-03 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RBD-75-L-03 BNC straight panel s, female contacts (Figure 5) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RBD-50-S-04 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RBD-50-M-04 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RBD-50-L-04 (.060.217) (.035.118) (.060) (.025) RBD-75-S-04 (.138.276) (.083.197) (.118) (.050) RBD-75-M-04 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RBD-75-L-04

TNC Coaxial Connectors (ohms) RG cables Raychem cables (min. max.) (min. max.) (max.) (max.) Part number TNC straight s, male contacts (Figure 6) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RTD-50-S-00 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RTD-50-M-00 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RTD-50-L-00 (.060.217) (.035.118) (.060) (.025) RTD-75-S-00 (.138.276) (.083.197) (.118) (.050) RTD-75-M-00 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RTD-75-L-00 TNC right-angle s, male contacts (Figure 7) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RTD-50-S-01 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RTD-50-M-01 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RTD-50-L-01 (.060.217) (.035.118) (.060) (.025) RTD-75-S-01 (.138.276) (.083.197) (.118) (.050) RTD-75-M-01 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RTD-75-L-01 TNC straight bulkhead s, female contacts (Figure 8) RG-196,RG 316 5030A1317 (.060.217) (.035.118) (.060) (.025) RTD-50-S-02 RG-303, RG-400 5020A1311 (.138.276) (.083.197) (.118) (.050) RTD-50-M-02 RG-225, RG-214 (.197.500) (.161.375) (.287) (.100) RTD-50-L-02 (.060.217) (.035.118) (.060) (.025) RTD-75-S-02 (.138.276) (.083.197) (.118) (.050) RTD-75-M-02 RG-144, RG-216 (.197.500) (.161.375) (.287) (.100) RTD-75-L-02

Product characteristics Solder Transition Center contact Dielectric insulator Connector body Insulation sleeve Shield Insulation sleeve and solder Material Center contact Dielectric insulator Transition Connector body Solder and flux Braided shield Insulation sleeve Strain relief/sealing sleeve Typical Performance Dielectric withstand voltage Insulation resistance Gold-plated beryllium copper (female) Gold-plated brass (male) PTFE Silver-plated brass Nickel-plated brass Sn63Pb37, RMA flux Tin-plated copper wire per ASTM B3 Radiation-crosslinked, heat-shrinkable polyvinylidene fluoride (Kynar), transparent blue Radiation-crosslinked, heat-shrinkable modified polyolefin with adhesive, black 1500 V 5000 megohms Temperature rating 55 C to 150 C Contact resistance-straight Inner 1.5 milliohms, outer 1.0 milliohm Contact resistance-right angle Inner 2.5 milliohms, outer 1.5 milliohms Cable retention force 295N (66 lb) to 822N (196 lb) Voltage rating 500 V RMS Connector durability 500 mating cycles minimum Electrical Performance Nominal impedance 50 and 75 ohms Frequency range Up to 2.8 GHz Specifications Installation Raychem RB-115 For proper installation of these devices, the correct heating tool and reflector attachment must be used. Any one of the following Raychem heating tools is recommended: Steinel Model HL1802E CV-1981 Refer to Raychem installation procedure RPIP 683-00 for detailed instructions. Cheminax and Raychem are trademarks of Tyco Electronics Corporation. Kynar is a trademark of Elf Atochem North America, Inc. All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics only obligations are those in the Standard Terms and Conditions of Sale for this product and in no case will Tyco Electronics be liable for any incidental, indirect or consequential damages arising from the sale, resale, use, or misuse of the product. Tyco Electronics Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right to make changes in materials or processing without notification to the Buyer which do not affect compliance with any applicable specification. Tyco Electronics Corporation Tyco Electronics UK Ltd. Tyco Electronics Raychem K.K. Raychem Singapore Pte. Ltd. Raychem Raychem Raychem Raychem 305 Constitution Drive Cheney Manor Industrial Estate 3816 Noborito, Tama-ku No. 26 Ang Mo Kio Ind. Park Menlo Park, CA 94025 Swindon, Wiltshire SN2 2QE Kawasaki 214-8533 Singapore 569507 U.S.A. U.K. Japan www.tycoelectronics.com 1997, 2000 Tyco Electronics Corporation Printed in USA H56351 10/00