Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Similar documents
Property of Monitronics Inc

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Property of Monitronics Inc

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Control/Communicator Installation Manual

TABLE OF CONTENTS TABLE OF CONTENTS 1

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

GEM-P800 Programming Instructions

Control/Communicator

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

First Alert 1200C Installer Notes M. Leuck

Installation Instructions

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

INSTALLATION MANUAL & PROGRAM RECORD SHEET

EVO192 v3.0 Fire and Burglary What s New

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

INSTALLATION MANUAL PC56O. Version 1.OA

NX-4V2 Control Panel Installation Instructions

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A

INSTALLATION MANUAL PC15OO

CC488. Quick Reference Guide Solution Ultima 880

Radionics D4112 Program Sheet

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

System Programming Guide

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Installation Manual Premier 412/816/832. Issue 10

AXI LED USER MANUAL (REV. 1.0)

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Contents. Glossary

GEM-P800. Control Panel/Communicator. Installation Instructions

CC408. Quick Reference Guide Solution 880

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

NetworX Series NX-4V2 Control Panel Installation and Startup

INSTALLATION MANUAL PC25OO

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Quick Programmer s Manual

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

2000 Series. Program Entry Guide. Control Panels

Training Manual Multi-Language with Wireless

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

Version 1.03 January-2002 USER S MANUAL

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

VISTA-100 Commercial Fire & Burglary Partitioned System

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Security System. User Guide for the LED Command Center

System Introduction. 1.1 Specifications

R E G E N C Y Model 2615 Control/Communicator. Installation Manual. Part Number , Rev. A Initial Release Date: March 1995 Revised August 1998

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. 1.1 Specifications S E C T I O N 1

Installation Instructions

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

Contact ID as of 2/2/2015

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

INSTALLATION MANUAL. PC3OOO Version 7.6W

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

Summit 3208GLD USER MANUAL. Electronics Line

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2.

FBII Security System. Programming Guide. Version 2.X. N9938PRV3 4/04 Rev. A

Sentry 4 Zone Alarm Panel User Manual

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

/10 Rev A

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

Digiplex Control Panel (DGP-848) - V4.0

8-zone Expansion Module

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

Independent Zone Control (I.Z.C.)

4-PGM Expansion Module

Solution-8248 Installation Manual ISSUE 1.16

Series. NX-4-EUR Control Panel. Installation manual

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

SMS8 Alarm Control Panel

Security System. User s Guide for the Text Command Center

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

Watchguard WGAP864 User Manual

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Transcription:

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response Option (10 msec ) LED Zone Display Upon Entry 40 Second Dialer Delay on Stay For All Zones 6 Programmable User Codes 4 Selectable Emergency Keypad Conditions False Alarm Reduction Features 2 Programmable Trigger Output C/S Test Timer Offset 2 Alarm Event History Log Bell Supervision For NFPA 72 LED or LCD Keypad Compatible 2 Programmable Entry Delay Times Unattended and On-Line Downloading

XL-2G Gold Terminal Connections 1+ 2-3+ 4+ 5-6+ 7+ 8-9+ Zone Zone Zone Zone Zone Zone # 1 # 2 # 3 # 4 # 5 # 6 2.2K 2.2K 2.2K 2.2K 2.2K 2.2K Zones 1(+) &2(-) Zone 1 (requires 2.2k EOL resistor) 2(-) & 3(+) Zone 2 (requires 2.2k EOL resistor) 4(+) & 5(-) Zone 3 (requires 2.2k EOL resistor) 5(-) & 6(+) Zone 4 (requires 2.2k EOL resistor) 7(+)& 8(-) 8(-)& 9(+) Zone 5 (requires 2.2k EOL resistor) Zone 6 (requires 2.2k EOL resistor) Maximum loop resistance 100 ohms Programmable loop response 10ms. or 280ms.

Panic Circuit or Keyswitch 8 10 NON SUPERVISED Panic Normally open, NON-SUPERVISED 24 hour hardwired panic circuit can be programmed as audible or silent. A momentary device recommended. (max. 3 feet from panel on UL installation) Terminals may also be used to connect a keyswitch which will toggle to arm and disarm the control panel Earth Ground Terminal # 11 Connect to cold water pipe utilizing #18 awg wire at 15 foot maximum.

Keypad Connections 12-13 14 15+ Neg. Data Data Pos. In Out Maximum of 4 keypads, max. loop length is 500 ft. with 22 awg wire 4600SM 4600RM 6615 6805(LCD) 30mA current draw each Keypads should be connected prior to power up. Regulated Power 12-15+ Negative Positive 500 ma at 11.8-12.5 VDC includes power used by keypads and smoke detectors.

Smoke Detector Power OR Trigger #1 Output 15+ 16- Positive Negative Accepts 4 wire smoke detectors only, approximately 50mA of current for powering all smoke detectors and E.O.L. relay ( Recommended FBI model 620). *These terminals adhere to fire verification logic* * when used to power smoke detectors.* Two Trigger Outputs Terminals 15+ & 16- may also be used as trigger #1 output Trigger Outputs #1 & #2 may also be connected using the XL-2GTC trigger connector cable

Telephone Line Connections 17 18 19 20 Green Red Brown Gray Telco Tip Telco Ring Home Tip Home Ring Plug into USOCRJ31X jack or CA31A(Canadian) Do not connect to phone line with call waiting, unless call waiting interrupt numbers are programmed into phone sequence. *Do not connect to phone line with Fax or modem in use* Constant DC Power Terminal # 21 Constant unregulated 10.0-15.5 VDC, powers devices using constant DC voltage Connected to Bell fuse (F3)

Bell Output 22 23 Positive Negative Total output 1 AMP 10.5-15.5 VDC(Res.) or 12.0-14.4 (comm.) Constant voltage for burglary and pulsed for fire. (750mA for UL) NFPA 72 Signaling Device Supervision For Mechanical Bells, Self Contained Siren/Speakers, Speakers Connected To Siren Driver Program Loop # 6 As a Fire Zone An Open Circuit (Not A Short) will initiate a Fire Trouble Condition

22+ NFPA 72 Signaling Device Supervision XL-2G FBII VS-299 Voice Siren Driver VS-299 Speaker Bell Output 23-10K 1/4Watt Siren Driver (+) (-) To 24 Hour Zone FBII 679S Siren Driver To 24 Hour Zone (+) 22+ Bell Output 23-679S Siren Driver 2.2K EOL (-)

Transformer 24 25 Connect 12 VAC 20VA transformer, utilizing 18 awg wire max 15 feet from panel. Use unswitched 120 VAC outlet Backup Battery: Red(+) and Black(-) flying leads connected to 12VDC 4-6 AH gel cell. Battery test approx. every 4.5 minutes. Low battery condition occurs at 11VDC. Ground Start Recommended is the use of an FBII module 117. SYSTEM STABILIZATION ON POWER UP Two Minute Delay Reduces Motion Detector False Alarms

XL-2G Keypad Programming 01 Primary Telco # L5 L6 L7 L8 L9 L10 L11 L12 02 Secondary Telco# L5 L6 L7 L8 L9 L10 L11 L12 03 Callback # L5 L6 L7 L8 L9 L10 L11 L12 0-9 Valid B = * C = 3 Sec Pause E = *70 (Touch-tone) or 1170C (Rotary) F = 800 prefix

04 Dialer Options 1601 L1 Dialer Formats Dialing Format Pulse Touchtone CS Reporting Format 0 Standard Or 4 X 2 1 Standard Or 4 X 2 2 Extended 3 Extended 4 Partial Extended 5 Partial Extended 8 None No Dialer/ Local System

04 Dialer Options 1601 L2 Central Station Receiver Type E FBI, Rad Handshake Typical CS Format Pulse Speed Frequency Parity Receiver 10 PPS 20 PPS 40 PPS 1400 HZ 2300 HZ 0 FBI, Ademco,Silent Knight 1 FBI 2 FBI 3 FBI 4 FBI, Silent Knight, Adcor,Ademco 5 FBI, Radionics 6 FBI, Franklin,Sescoa,Dti,Varitech 7 FBI, Radionics 8 FBI 9 FBI A FBI B FBI, Radionics

04 Dialer options 1601 L3 Message length, swinger shutdown FBI, Rad CS Reporting Format Lenth Swinger Dialing Pulse Type 3 X 1 3 X 2 4 X 1 4 X 2 Shutdown U.S European 0 1 2 3 4 5 6 7 8 9 A B C D E F * For UL installations swinger shutdown must not be selected*

04 Dialer Options 1601 L4 System options : Keypad panic silent/audible, C/S split reporting, C/S test, bell test Keypad Panic C/S Split Cancel Code Bell Ringback System Bell Audible / Silent Reporting Silent / Audible Test 0 1 2 3 4 5 6 7 8 9 A B C D E F

05 Keypad Conditions 1270 L1 Enable: Keypad Panic(* & #), System Stay Mode- Dialer Delay, Stay Mode- Bell Instant Keypad Aux (1&3) Digit Keypad Stay Mode Stay Mode Keypad Auxiliary Panic Dialer Delay Bell Instant Audible / Silent 0 1 2 3 4 5 6 7 8 9 A B C D E F

05 Keypad conditions 1270 L2 Panic/keyswitch, hard wired panic silent/audible, A/C Line Frequency, Keypad Quick Commands ZONE # 7 INPUT A/C Quick Panic Keyswitch Line Frequency Commands Digit (Audible / Silent) 50Hz / 60Hz Enabled 0 1 2 4 5 6 8 9 A C D E

05 Keypad Conditions 1270 L3 C/S Test Timer Interval and European Ring Detect Digit C/S Test Time Interval European 1 Hour 24 Hour Weekly 27 Days 60 Days 90 Days Ring Detect 0 1 2 3 4 6 7 8 9 A B C E F *All test time intervals are reset after a successful CS report *

05 Keypad conditions 1270 L4 Restore follows bell or loop, CS test ringback User on line, Instant Arming Enabled Digit Restore After User-On C/S Test Keypad Ringback Instant Bell Loop Line Silent Audible Arming 0 1 2 3 4 5 6 7 8 9 A B C D E F

06 System Time-outs 665F L1 Entry delay #1: Zones 1-3 only 30 seconds L2 Exit delay System wide 60 seconds Digit Entry Time-outs 0 1 Second 1 5 Seconds 2 10 seconds 3 15 seconds 4 20 seconds 5 25 Seconds 6 30 Seconds 7 35 Seconds 8 40 Seconds 9 45 Seconds A 50 Seconds B 55 Seconds C 1 Minute D 1 Minute 5 Seconds E 1 minute 10 Seconds F 3 Minutes Digit Exit Time-outs 0 1 Second 1 10 Seconds 2 20 seconds 3 30 seconds 4 40 seconds 5 50 Seconds 6 1 Minute 7 1 Minute 10 Seconds 8 1 Minute 20 Seconds 9 1 Minute 30 Seconds A 1 minute 40 Seconds B 11minute 50 Seconds C 2 Minutes D 2 Minutes 10 Seconds E 2 Minutes 20 Seconds F 3 minutess

06 System Time-outs 665F L3 Burglary Bell Cutoff 15 Minutes L4 Fire Bell Cutoff Infinite Digit Burglary & Fire Bell Time-outs 1 3 Minutes 2 6 Minutes 3 9 Minutes 4 12 minutes 5 15 Minutes 6 18 Minutes 7 21 Minutes 8 24 minutes 9 27 Minutes A 30 minutes B 33 Minutes C 36 minutes D 39 Minutes E 42 minutes F Infinite

07 Miscellaneous 2C05 System Options L1 Entry Delay # 2 Zones 4-6 only ( Valid choices are selected from question # 6 ) L2 Ring Count for panel pick up for a remote communications session & dialer delay Digit Ring Count For Dialer Pickup Delay 0 Remote Communications Disabled 1 2 Rings 2 4 Rings 3 6 Rings 4 8 Rings 5 10 Rings 6 12 Rings 7 14 Rings 8 Remote Communications Disabled 9 2 Ringss A 4 Rings B 6 Rings C 8 Ring D 10 Rings E 12 Rings F 14 Rings

07 Miscellaneous 2C05 System Options L3 Smoke Power or Trigger #1 output types L4 Trigger # 2 output types Valid Entries Description of Operation 0 = Smoke power output Used in Fire verification to reset smokes 1 = Fire bell on Follows fire bell timer 2 = Burg bell on Follows burg bell timer 3 = Line seizure Follows line seizure relay 4 = Ready Follows ready LED 5 = Armed Follows armed LED (steady states only) 6 = Exit time ON during exit time 7 = Entry time ON during entry time 8 = Fire only latch Goes ON with Fire bell, OFF with code 9 = Burg only latch Goes ON with Burg bell, OFF with code A = Strobe B = Panic alarm C = Shock asterisk reset D = Shock code reset E = Duress Goes ON steady w/burg, pulse w/fire OFF with code Zone 7 (hardwired panic) ON with Alarm OFF with code * Activates for 2-6 seconds Normally sinking current: arming floats for 2-6 seconds Pulse 2-6 Sec. Following Duress Code

Unless otherwise specified, trigger output normally floats and actively sinks on activation 08 Account # 1 Valid entries: 0-9 & B - F 09 Account # 2 Valid entries: 0-9 & B - F

10 Zone programming 2031 L1 & L2 #1 Zone Type, L3 & L4 C/S Code Burglary (Controlled ) Zones Digit Zone Type Zone Options Instant Delay Int. Follower Chime Day Bypass In Stay Fast Zone 10 ( None W/O Options ) 11 12 13 14 15 18 19 1A 1B 1C 1D 20 ( None W/O Options ) 21 24 25 40 ( None W/O Options ) 41 44 45 48 49 4C 4D 24 Hour Zone Types 24 Hour Zone Options 24 Hour Alarm Fire 24 Hour Trouble Audible Silent 81 82 84 (Always Audible) 89 8A

11 Zone programming L1 & L2 Zone type for zone # 2 41 ( Interior ) L3 & L4 CS zone alarm code 32 12 Zone programming L1 & L2 Zone type for zone # 3 10 ( Perimeter ) L3 & L4 CS zone alarm code 33 13 Zone programming L1 & L2 Zone type for zone # 4 10 ( Perimeter ) L3 & L4 CS zone alarm code 34 14 Zone programming L1 & L2 Zone type for zone # 5 10 ( Perimeter ) L3 & L4 CS zone alarm code 35 15 Zone programming L1 & L2 Zone type for zone # 6 10 ( Perimeter ) L3 & L4 CS zone alarm code 36

16 Ambush/AC Loss L1 & L2 Ambush C/S code (user # 6) Immediate and non abortable L3 & L4 A/C Loss C/S code Reported 15 min. after detection AA AA 17 Panic/Low Battery L1 & L2 Panic C/S code (keypad & remote) 22 Immediate and non abortable L3 & L4 Low Battery C/S code AA Reported 4 min. after detection 18 Open/Close, 24 Hour test L1 Opening C/S code (1st digit of 4x2 code) 2nd digit is the user slot number 1-6 L2 Closing C/S code (1st digit of 4x2 code) 2nd digit is the user slot number 1-6 A A L3 & L4 C/S test code AA

19 Bypass, Restore, Trouble, Cancel L1 Bypass C/S code (1st digit of 4x2) A Reports zone bypass upon arming (2nd digit from zone code) L2 Restore C/S code (1st digit of 4x2) A Reports 24 hour and burglary zones(2nd digit from zone code) L3 Trouble C/S code (1st digit of 4x2) F Reports Fire trouble or Day trouble (2nd digit from zone code) L4 Cancel C/S code (1st digit of 4x2) 8 Sent if after a violation of a controlled zone, a user code is entered. If the zone is still violated, entry of a user code will transmit cancel code. If the zone is programmed for restoral, then restore code will be sent when loop restores. 20 Keypad Fire/Aux L1 & L2 Keypad fire C/S code (7 & 9) AA C/S Code can vary from any other fire zones L3 & L4 Keypad Auxiliary C/S code (1 & 3) AA

21 C/S Test Timer Offset L1 & L2 C/S Offset in Hours L3 & L4 C/S offset in Minutes AA AA Allows the setting of the time for C/S test to occur offset from the time at installation 00 Installer Code 2468 L1 - L4 This code is used to enter system keypad programming and may only be accessed directly

XL-2G Gold Zone Descriptor Programming Question # 22 (zone 1) through Question # 27 (zone 6) L5 L6 L7 L8 L9 L10 L11 L12 Quest: 22 Front Door 7 increments the character at the cursor * 7 scrolls forward (up) through character set 9 Decrements the character at the cursor # 9 scrolls backwards through character set 0 Inserts space and advances cursor Code Instant moves cursor to the left one space moves the cursor to the right one space Available Characters

! #$%& ( )*+-./0123456789;=@ABCDEFGHIJKLMNOPQRSTUVWXYZ XL-2G Gold Summary Of System Keypad Programming Enter programming mode Code * (installer code) 1 Movement between questions * followed by question # ( i.e.: *06) Advance Between locations (Enter) # D Data entry 0-9 valid entries A T Ques : 11 Loc: 1 A Code 1 A B Code 2 Data: 5 C Code 3 Q D Code 4 U E Code 5 E F Code 6 S T +1 Arm +2 Stay +4 Instant +8 AC/LB Ready +1 Zone 1 +2 Zone 2 +4 Zone 3 +8 Zone 4 +16 Zone 5 Zone 6 Exit system program mode Stay button to exit

XL-2G Gold Keypad Installer Modes Installer Mode 1 (keypad programming) a) Pressing 1 & 3 together in this mode will default system to original factory program b) Pressing 7 & 9 together in this mode will default ONLY end user codes Installer Mode 2 ( system log view) a) View last 2 alarm memory conditions starting with oldest event, the # will advance to most recent event. Installer Mode 3 (unattended downloading) a) enter unattended download mode b) system enters keypad programming, proceed to question 03 and program Downloader phone number c) Proceed to question 02 and enter 6 digit computer designated account number d) Press the Stay button, the control panel will now perform the desired download operation. Installer Mode 4 (on line download) a) Call person at download computer using telco line connected to panel b) Verbally identify the panel account number to operator c) Enter [Code] [*] [installer] [4] or #9 (if programmed) d) Hang up telephone

XL-2G Gold User Functions Arming/Disarming Stay Arming Stay/Instant Arming [Enter any valid user code] [Stay] [Enter any valid user code] [Stay] [Instant] [Enter valid user code] Bypass [Bypass] [Enter valid user code][zone #] Quick Bypass [Bypass] [Zone #] User Code Programming [Code] [Enter master user code (slot #1)] [User slot # to program] [Enter 4 digit code] User Code Deletion [Code][Enter master user code][user #][*] Quick Arming [ # ] [ 1 ] Quick Forced Arming [ # ] [ 2 ] Toggle Chime [ # ] [ 6 ] On-Line Downloading [ # ] [ 9 ] Ambush [ Enter user code slot # 6 ] Keypad Panic [ * ] & [ # ] at the same time ** Keypad Fire [ 7 ] & [ 9 ] at the same time ** Auxiliary [ 1 ] & [ 3 ] at the same time ** ** Functions are used ONLY on the 6805, 6615 & 4600RM keypads