Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96
XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response Option (10 msec ) LED Zone Display Upon Entry 40 Second Dialer Delay on Stay For All Zones 6 Programmable User Codes 4 Selectable Emergency Keypad Conditions False Alarm Reduction Features 2 Programmable Trigger Output C/S Test Timer Offset 2 Alarm Event History Log Bell Supervision For NFPA 72 LED or LCD Keypad Compatible 2 Programmable Entry Delay Times Unattended and On-Line Downloading
XL-2G Gold Terminal Connections 1+ 2-3+ 4+ 5-6+ 7+ 8-9+ Zone Zone Zone Zone Zone Zone # 1 # 2 # 3 # 4 # 5 # 6 2.2K 2.2K 2.2K 2.2K 2.2K 2.2K Zones 1(+) &2(-) Zone 1 (requires 2.2k EOL resistor) 2(-) & 3(+) Zone 2 (requires 2.2k EOL resistor) 4(+) & 5(-) Zone 3 (requires 2.2k EOL resistor) 5(-) & 6(+) Zone 4 (requires 2.2k EOL resistor) 7(+)& 8(-) 8(-)& 9(+) Zone 5 (requires 2.2k EOL resistor) Zone 6 (requires 2.2k EOL resistor) Maximum loop resistance 100 ohms Programmable loop response 10ms. or 280ms.
Panic Circuit or Keyswitch 8 10 NON SUPERVISED Panic Normally open, NON-SUPERVISED 24 hour hardwired panic circuit can be programmed as audible or silent. A momentary device recommended. (max. 3 feet from panel on UL installation) Terminals may also be used to connect a keyswitch which will toggle to arm and disarm the control panel Earth Ground Terminal # 11 Connect to cold water pipe utilizing #18 awg wire at 15 foot maximum.
Keypad Connections 12-13 14 15+ Neg. Data Data Pos. In Out Maximum of 4 keypads, max. loop length is 500 ft. with 22 awg wire 4600SM 4600RM 6615 6805(LCD) 30mA current draw each Keypads should be connected prior to power up. Regulated Power 12-15+ Negative Positive 500 ma at 11.8-12.5 VDC includes power used by keypads and smoke detectors.
Smoke Detector Power OR Trigger #1 Output 15+ 16- Positive Negative Accepts 4 wire smoke detectors only, approximately 50mA of current for powering all smoke detectors and E.O.L. relay ( Recommended FBI model 620). *These terminals adhere to fire verification logic* * when used to power smoke detectors.* Two Trigger Outputs Terminals 15+ & 16- may also be used as trigger #1 output Trigger Outputs #1 & #2 may also be connected using the XL-2GTC trigger connector cable
Telephone Line Connections 17 18 19 20 Green Red Brown Gray Telco Tip Telco Ring Home Tip Home Ring Plug into USOCRJ31X jack or CA31A(Canadian) Do not connect to phone line with call waiting, unless call waiting interrupt numbers are programmed into phone sequence. *Do not connect to phone line with Fax or modem in use* Constant DC Power Terminal # 21 Constant unregulated 10.0-15.5 VDC, powers devices using constant DC voltage Connected to Bell fuse (F3)
Bell Output 22 23 Positive Negative Total output 1 AMP 10.5-15.5 VDC(Res.) or 12.0-14.4 (comm.) Constant voltage for burglary and pulsed for fire. (750mA for UL) NFPA 72 Signaling Device Supervision For Mechanical Bells, Self Contained Siren/Speakers, Speakers Connected To Siren Driver Program Loop # 6 As a Fire Zone An Open Circuit (Not A Short) will initiate a Fire Trouble Condition
22+ NFPA 72 Signaling Device Supervision XL-2G FBII VS-299 Voice Siren Driver VS-299 Speaker Bell Output 23-10K 1/4Watt Siren Driver (+) (-) To 24 Hour Zone FBII 679S Siren Driver To 24 Hour Zone (+) 22+ Bell Output 23-679S Siren Driver 2.2K EOL (-)
Transformer 24 25 Connect 12 VAC 20VA transformer, utilizing 18 awg wire max 15 feet from panel. Use unswitched 120 VAC outlet Backup Battery: Red(+) and Black(-) flying leads connected to 12VDC 4-6 AH gel cell. Battery test approx. every 4.5 minutes. Low battery condition occurs at 11VDC. Ground Start Recommended is the use of an FBII module 117. SYSTEM STABILIZATION ON POWER UP Two Minute Delay Reduces Motion Detector False Alarms
XL-2G Keypad Programming 01 Primary Telco # L5 L6 L7 L8 L9 L10 L11 L12 02 Secondary Telco# L5 L6 L7 L8 L9 L10 L11 L12 03 Callback # L5 L6 L7 L8 L9 L10 L11 L12 0-9 Valid B = * C = 3 Sec Pause E = *70 (Touch-tone) or 1170C (Rotary) F = 800 prefix
04 Dialer Options 1601 L1 Dialer Formats Dialing Format Pulse Touchtone CS Reporting Format 0 Standard Or 4 X 2 1 Standard Or 4 X 2 2 Extended 3 Extended 4 Partial Extended 5 Partial Extended 8 None No Dialer/ Local System
04 Dialer Options 1601 L2 Central Station Receiver Type E FBI, Rad Handshake Typical CS Format Pulse Speed Frequency Parity Receiver 10 PPS 20 PPS 40 PPS 1400 HZ 2300 HZ 0 FBI, Ademco,Silent Knight 1 FBI 2 FBI 3 FBI 4 FBI, Silent Knight, Adcor,Ademco 5 FBI, Radionics 6 FBI, Franklin,Sescoa,Dti,Varitech 7 FBI, Radionics 8 FBI 9 FBI A FBI B FBI, Radionics
04 Dialer options 1601 L3 Message length, swinger shutdown FBI, Rad CS Reporting Format Lenth Swinger Dialing Pulse Type 3 X 1 3 X 2 4 X 1 4 X 2 Shutdown U.S European 0 1 2 3 4 5 6 7 8 9 A B C D E F * For UL installations swinger shutdown must not be selected*
04 Dialer Options 1601 L4 System options : Keypad panic silent/audible, C/S split reporting, C/S test, bell test Keypad Panic C/S Split Cancel Code Bell Ringback System Bell Audible / Silent Reporting Silent / Audible Test 0 1 2 3 4 5 6 7 8 9 A B C D E F
05 Keypad Conditions 1270 L1 Enable: Keypad Panic(* & #), System Stay Mode- Dialer Delay, Stay Mode- Bell Instant Keypad Aux (1&3) Digit Keypad Stay Mode Stay Mode Keypad Auxiliary Panic Dialer Delay Bell Instant Audible / Silent 0 1 2 3 4 5 6 7 8 9 A B C D E F
05 Keypad conditions 1270 L2 Panic/keyswitch, hard wired panic silent/audible, A/C Line Frequency, Keypad Quick Commands ZONE # 7 INPUT A/C Quick Panic Keyswitch Line Frequency Commands Digit (Audible / Silent) 50Hz / 60Hz Enabled 0 1 2 4 5 6 8 9 A C D E
05 Keypad Conditions 1270 L3 C/S Test Timer Interval and European Ring Detect Digit C/S Test Time Interval European 1 Hour 24 Hour Weekly 27 Days 60 Days 90 Days Ring Detect 0 1 2 3 4 6 7 8 9 A B C E F *All test time intervals are reset after a successful CS report *
05 Keypad conditions 1270 L4 Restore follows bell or loop, CS test ringback User on line, Instant Arming Enabled Digit Restore After User-On C/S Test Keypad Ringback Instant Bell Loop Line Silent Audible Arming 0 1 2 3 4 5 6 7 8 9 A B C D E F
06 System Time-outs 665F L1 Entry delay #1: Zones 1-3 only 30 seconds L2 Exit delay System wide 60 seconds Digit Entry Time-outs 0 1 Second 1 5 Seconds 2 10 seconds 3 15 seconds 4 20 seconds 5 25 Seconds 6 30 Seconds 7 35 Seconds 8 40 Seconds 9 45 Seconds A 50 Seconds B 55 Seconds C 1 Minute D 1 Minute 5 Seconds E 1 minute 10 Seconds F 3 Minutes Digit Exit Time-outs 0 1 Second 1 10 Seconds 2 20 seconds 3 30 seconds 4 40 seconds 5 50 Seconds 6 1 Minute 7 1 Minute 10 Seconds 8 1 Minute 20 Seconds 9 1 Minute 30 Seconds A 1 minute 40 Seconds B 11minute 50 Seconds C 2 Minutes D 2 Minutes 10 Seconds E 2 Minutes 20 Seconds F 3 minutess
06 System Time-outs 665F L3 Burglary Bell Cutoff 15 Minutes L4 Fire Bell Cutoff Infinite Digit Burglary & Fire Bell Time-outs 1 3 Minutes 2 6 Minutes 3 9 Minutes 4 12 minutes 5 15 Minutes 6 18 Minutes 7 21 Minutes 8 24 minutes 9 27 Minutes A 30 minutes B 33 Minutes C 36 minutes D 39 Minutes E 42 minutes F Infinite
07 Miscellaneous 2C05 System Options L1 Entry Delay # 2 Zones 4-6 only ( Valid choices are selected from question # 6 ) L2 Ring Count for panel pick up for a remote communications session & dialer delay Digit Ring Count For Dialer Pickup Delay 0 Remote Communications Disabled 1 2 Rings 2 4 Rings 3 6 Rings 4 8 Rings 5 10 Rings 6 12 Rings 7 14 Rings 8 Remote Communications Disabled 9 2 Ringss A 4 Rings B 6 Rings C 8 Ring D 10 Rings E 12 Rings F 14 Rings
07 Miscellaneous 2C05 System Options L3 Smoke Power or Trigger #1 output types L4 Trigger # 2 output types Valid Entries Description of Operation 0 = Smoke power output Used in Fire verification to reset smokes 1 = Fire bell on Follows fire bell timer 2 = Burg bell on Follows burg bell timer 3 = Line seizure Follows line seizure relay 4 = Ready Follows ready LED 5 = Armed Follows armed LED (steady states only) 6 = Exit time ON during exit time 7 = Entry time ON during entry time 8 = Fire only latch Goes ON with Fire bell, OFF with code 9 = Burg only latch Goes ON with Burg bell, OFF with code A = Strobe B = Panic alarm C = Shock asterisk reset D = Shock code reset E = Duress Goes ON steady w/burg, pulse w/fire OFF with code Zone 7 (hardwired panic) ON with Alarm OFF with code * Activates for 2-6 seconds Normally sinking current: arming floats for 2-6 seconds Pulse 2-6 Sec. Following Duress Code
Unless otherwise specified, trigger output normally floats and actively sinks on activation 08 Account # 1 Valid entries: 0-9 & B - F 09 Account # 2 Valid entries: 0-9 & B - F
10 Zone programming 2031 L1 & L2 #1 Zone Type, L3 & L4 C/S Code Burglary (Controlled ) Zones Digit Zone Type Zone Options Instant Delay Int. Follower Chime Day Bypass In Stay Fast Zone 10 ( None W/O Options ) 11 12 13 14 15 18 19 1A 1B 1C 1D 20 ( None W/O Options ) 21 24 25 40 ( None W/O Options ) 41 44 45 48 49 4C 4D 24 Hour Zone Types 24 Hour Zone Options 24 Hour Alarm Fire 24 Hour Trouble Audible Silent 81 82 84 (Always Audible) 89 8A
11 Zone programming L1 & L2 Zone type for zone # 2 41 ( Interior ) L3 & L4 CS zone alarm code 32 12 Zone programming L1 & L2 Zone type for zone # 3 10 ( Perimeter ) L3 & L4 CS zone alarm code 33 13 Zone programming L1 & L2 Zone type for zone # 4 10 ( Perimeter ) L3 & L4 CS zone alarm code 34 14 Zone programming L1 & L2 Zone type for zone # 5 10 ( Perimeter ) L3 & L4 CS zone alarm code 35 15 Zone programming L1 & L2 Zone type for zone # 6 10 ( Perimeter ) L3 & L4 CS zone alarm code 36
16 Ambush/AC Loss L1 & L2 Ambush C/S code (user # 6) Immediate and non abortable L3 & L4 A/C Loss C/S code Reported 15 min. after detection AA AA 17 Panic/Low Battery L1 & L2 Panic C/S code (keypad & remote) 22 Immediate and non abortable L3 & L4 Low Battery C/S code AA Reported 4 min. after detection 18 Open/Close, 24 Hour test L1 Opening C/S code (1st digit of 4x2 code) 2nd digit is the user slot number 1-6 L2 Closing C/S code (1st digit of 4x2 code) 2nd digit is the user slot number 1-6 A A L3 & L4 C/S test code AA
19 Bypass, Restore, Trouble, Cancel L1 Bypass C/S code (1st digit of 4x2) A Reports zone bypass upon arming (2nd digit from zone code) L2 Restore C/S code (1st digit of 4x2) A Reports 24 hour and burglary zones(2nd digit from zone code) L3 Trouble C/S code (1st digit of 4x2) F Reports Fire trouble or Day trouble (2nd digit from zone code) L4 Cancel C/S code (1st digit of 4x2) 8 Sent if after a violation of a controlled zone, a user code is entered. If the zone is still violated, entry of a user code will transmit cancel code. If the zone is programmed for restoral, then restore code will be sent when loop restores. 20 Keypad Fire/Aux L1 & L2 Keypad fire C/S code (7 & 9) AA C/S Code can vary from any other fire zones L3 & L4 Keypad Auxiliary C/S code (1 & 3) AA
21 C/S Test Timer Offset L1 & L2 C/S Offset in Hours L3 & L4 C/S offset in Minutes AA AA Allows the setting of the time for C/S test to occur offset from the time at installation 00 Installer Code 2468 L1 - L4 This code is used to enter system keypad programming and may only be accessed directly
XL-2G Gold Zone Descriptor Programming Question # 22 (zone 1) through Question # 27 (zone 6) L5 L6 L7 L8 L9 L10 L11 L12 Quest: 22 Front Door 7 increments the character at the cursor * 7 scrolls forward (up) through character set 9 Decrements the character at the cursor # 9 scrolls backwards through character set 0 Inserts space and advances cursor Code Instant moves cursor to the left one space moves the cursor to the right one space Available Characters
! #$%& ( )*+-./0123456789;=@ABCDEFGHIJKLMNOPQRSTUVWXYZ XL-2G Gold Summary Of System Keypad Programming Enter programming mode Code * (installer code) 1 Movement between questions * followed by question # ( i.e.: *06) Advance Between locations (Enter) # D Data entry 0-9 valid entries A T Ques : 11 Loc: 1 A Code 1 A B Code 2 Data: 5 C Code 3 Q D Code 4 U E Code 5 E F Code 6 S T +1 Arm +2 Stay +4 Instant +8 AC/LB Ready +1 Zone 1 +2 Zone 2 +4 Zone 3 +8 Zone 4 +16 Zone 5 Zone 6 Exit system program mode Stay button to exit
XL-2G Gold Keypad Installer Modes Installer Mode 1 (keypad programming) a) Pressing 1 & 3 together in this mode will default system to original factory program b) Pressing 7 & 9 together in this mode will default ONLY end user codes Installer Mode 2 ( system log view) a) View last 2 alarm memory conditions starting with oldest event, the # will advance to most recent event. Installer Mode 3 (unattended downloading) a) enter unattended download mode b) system enters keypad programming, proceed to question 03 and program Downloader phone number c) Proceed to question 02 and enter 6 digit computer designated account number d) Press the Stay button, the control panel will now perform the desired download operation. Installer Mode 4 (on line download) a) Call person at download computer using telco line connected to panel b) Verbally identify the panel account number to operator c) Enter [Code] [*] [installer] [4] or #9 (if programmed) d) Hang up telephone
XL-2G Gold User Functions Arming/Disarming Stay Arming Stay/Instant Arming [Enter any valid user code] [Stay] [Enter any valid user code] [Stay] [Instant] [Enter valid user code] Bypass [Bypass] [Enter valid user code][zone #] Quick Bypass [Bypass] [Zone #] User Code Programming [Code] [Enter master user code (slot #1)] [User slot # to program] [Enter 4 digit code] User Code Deletion [Code][Enter master user code][user #][*] Quick Arming [ # ] [ 1 ] Quick Forced Arming [ # ] [ 2 ] Toggle Chime [ # ] [ 6 ] On-Line Downloading [ # ] [ 9 ] Ambush [ Enter user code slot # 6 ] Keypad Panic [ * ] & [ # ] at the same time ** Keypad Fire [ 7 ] & [ 9 ] at the same time ** Auxiliary [ 1 ] & [ 3 ] at the same time ** ** Functions are used ONLY on the 6805, 6615 & 4600RM keypads