RL-S EuroBrite Ring Light

Similar documents
BL-S EuroBrite Backlight

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

INSTRUCTION MANUAL C-4010 SCAN HERE

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Global Water Instrumentation, Inc.

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Feniex Hammer S Distributed By: Feniex Hammer Instruction Manual / feniex.com

Spectrum Illumination Machine Vision Lighting

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

IR detection module VPAC-1000F user's guide

E3M-V. Mark Sensor. Applications

STATUS ALARM HISTORY ALARM RESET

Sidekick II Receiver Model # SK2-SS 418MHz

LMA LINE MONITOR ALERT USER S MANUAL

USER MANUAL Table of Contents

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Introduction... 1 System Overview... 1 System Diagram... 2

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Preamplifier Power Supply PPS-02 user's guide

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

BLK-4/EWP Line Status LED Strobe/ Beacon Light Kit

NT DUAL CHANNEL DISPLAY. User Guide

IFS Fiber Module Installation & Operation Instructions

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Installation Instructions for the

Proliphix Thermostat Installation Guide. Release 2.0

Ultrasonic Reflective Sensor

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

METEOROLOGICAL INSTRUMENTS

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

onlinecomponents.com

SPILLSTOP ULTRA Hose Protection Overfill Prevention System

Phone: Fax: Web:

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

DHM5150 Human Motion Sensor Module User Manual

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

818E Series Energy Detector. User s Manual

Smart Home Outdoor Siren

The Affordable, All-Purpose Sensor That's EZ To Use!

Installation and Programming Instructions for the Federal Signal Serial Interface Module

PM100/PM100E PLANTER MONITOR. Operator s Manual

Universal Fan and Light Remote Control

BLK-4/EWP Line Status LED Strobe/ Beacon Light Kit

Alarm Tone Generator Model AG17

USER MANUAL Table of Contents

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Document No

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

CM Series. 2D Imager Modules. Compact 2D Imager Module for Kiosk Data Capture Operations FEATURES & BENEFITS DIFFERENTIATION VALUE TO CUSTOMERS

IFS Fiber Module Installation & Operation

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Active Infrared Multi Beam Sensors

IFS Fiber Module Installation & Operation Instructions

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

ALM100 Alarm Module. User s Manual

OmniCure AC5 Series. UV Curing Solutions. Applicable for the following UV LED Head models:

ELLA ID. High CRI, High lm/w OptoDrive LED-module

IFS Fiber Module Installation & Operation Instructions

Welcome to MultiSight TM Vision Sensor Hands-On Lab

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Active Infrared Multi Beam Sensors. R Series

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

VERSA INDOOR OLED LIGHT. Operating Instructions

IR detectors user's guide

General Purpose Photoelectric Sensor

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Model 1916-C/-R Hand-held Optical Power Meter

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

IFS Fiber Module Installation & Operation Instructions

Model NT20e Installation Guide

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

RMS-I-DE-01 Smoke Detector

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

SEC Signature Process Gas Analyzer

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

ELECTRONIC COMMUNICATING THERMOSTAT COOL AUTO. Hold Prog Mode Fan. Owner's Manual. RC-120 Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool

English. Series. Installation and Use Manual

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

HFX Fiber Optic Component 50 Mbps, 650 nm LED

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

OmniCure AC8-Series User Guide

SPILLSTOP ULTRA Alarm Controller with Hose Protection Overfill Prevention System

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

SPACE DETECTOR SP Presentation

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

Transcription:

S Version Combination Strobe/Continuous Product Highlights Cost-effective, feature-rich design Robust, sealed IP67 enclosure On-board smart driver - seamless strobe or continuous Adaptive Overdrive - optimized power under all strobe conditions Adaptive Power - factors in your light heat sink options and external temperature options to maximize performance and lifespan General Specifications Electrical Specifications Driver internal to light source inputs are tolerant to 3VDC Color WHI, 455, 47, 55, 53, 59,625, 66, 73, 85, 94 Current ~.54A Current draw will depend on what the EuroBrite is trained to do. If it is attached to a heat sink; draw will be slightly higher. No heat sinking; draw will be slightly lower. Input Voltage Range Maximum Input Current Strobe/On-Off Control Analog Intensity Control Trigger-to-Pulse Latency Normal Operating Temperature Weight (g) 24V nom. (min 22/max 28).42-.49A up to 5X overdrive, active high Analog.7-V;.7V=% V=% µsec - 6 C 72.4g (6.oz) Standard Cable Information Photobiological Risk Factor IEC 6247 No cable included; see part number LC2-M2-5-FM or use standard coded 5-pin M2. Exempt : 85, 94 Group (Low-Risk): 455, 47, 55, 53, 59, 625, 66, 73, WHI Compliance IP Rating Lumen Maintenance IP67 L7 = 5, hours

Mechanical Specifications 4X.9 x.3 OBROUND M2, 5 PIN CONNECTOR, MALE 2. (4.72). (4.33). (.39) () () 8. (.32) 2 (4.4) 2. (4.72) 32.4 (5.2) 3.3 (.8) 5.72 (.62) () DIMENSIONS ARE IN MILLIMETERS (INCHES) Part Number Key Model Control Model Indicator Lens Option Spectral Wavelength RL X XXXXXX X XXX RL S (strobe) 522 M (medium spread) W (wide spread) (royal blue) 455 (blue) 47 (cyan) 55 (green) 53 (amber) 59 (red orange) 625 (red) 66 (IR) 73 (IR) 85 (IR) 94 (White) WHI Ex: RL-S522W-625 RL-S522M-WHI Beam angle (FWHM): M (standard) = 2 W = 32 Stock Product: shipped within 3 days RL-S522M-47 RL-S522M-625 RL-S522M-WHI Build to Order: shipped within 2 weeks 2

Optical Performance Intensity Distribution 8-% 6-8% 4-6% 2-4% -2% -% =25mm Optical measurement taken using RL-S522M-WHI @ 3 mm Area of Illuminance & Intensity Working Area (FWHM) @ Working Distance Light Output 37.2 DIA (mm) @ 2 (mm) 47.3 DIA (mm) @ 3 (mm) Irradiance (W/M²): Min 88.4 ; Typ 4. Illuminace (klux): Min 28.3 ; Typ 33.3 Irradiance (W/M²): Min 64.3 ; Typ 75.6 Illuminace (klux): Min 2.8; Typ 24.5 23.4 DIA (mm) Irradiance (W/M²): Min 26.4 ; Typ 3. @ 6 (mm) Illuminace (klux): Min 8.5 ; Typ. 3

Operation & Wiring Modes of Operation Continuous Strobe Thermal Foldback Factory Reset To enable output: Tie Trigger+ (black) HIGH to >.5V. The light remains ON as long as Trigger+ is high Analog dimming is available: pin 5, gray EuroBrite S-version uses Adaptive Overdrive to produce overdrive pulses while the trigger is HIGH. Overdrive period occurs from -5msec; light output can be increased by as much as 5X. Overdriving does not occur when pulses exceed 5msec. Analog dimming is available: pin 5, gray To engage Thermal Foldback: Before turning the light on, tie pin 2 (white) to pin 3 (GND, blue). Onboard thermistor is sampled for 5 minutes. Light intensity will automaticaly adjust based on the case tempurature during the training period. The beginning of training is signified by a series of rapid flashes. While training, the light will blink every two seconds. A few slower blinks signal the end of the training period To engage Factory Reset: Before turning the light on, tie pin2 (white) to pin 3 (blue). For factory reset to occur, the light must be trained for thermal foldback first. Light will appear dim for 3-5 seconds then brightness will be set to factory default. After factory reset is complete disconnect white wire from blue wire for normal operation (before turning light back on). Tying pin 2 (white) to pin 3 (blue) will alternate between factory reset and thermal foldback modes. Standard Wiring Information Male 5-Position Pin Function Wire Color Type 24VDC Brown Power 2 Thermal Foldback White Input 3 GND Blue Power 4 Trigger + Black Input 5 Analog Gray Input Wiring Diagrams Basic Strobe Connection 5-3VDC * Analog Dimming ON GRAY / PIN 5 BLACK / PIN 4 OFF -VDC I/O PNP / SOURCING GND BLUE / PIN 3 GND BLUE / PIN 3 *External resistors may not be needed Check documentation on I/O for recommendations and voltage limits Analog dimming works in both strobe and continuous 4

Warranty Information Every Advanced illumination, Inc. (Ai) product is thoroughly inspected and tested before leaving the factory. Products are warranted to be free of defects in workmanship and materials for a period of two years from the original date of purchase. Should a defect develop during this period, please contact Ai Customer Service or your Ai distributor for a Return Merchandise Authorization (RMA), and return the complete product, freight prepaid, to Ai. If a defect is found, Ai will - at our discretion - repair or replace the product without charge. Ai claims no liability for any implied warranties, including merchantability and fitness for a specific purpose. Electromagnetic Compatibility This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) as stated in the product specifications. These requirements and limits are designed to provide reasonable protection against harmful interference only when the product is operated in its intended industrial electromagnetic environment. To minimize the potential for electromagnetic interference or unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Customer Service For information on existing orders, or to make an order adjustment, contact us Monday through Friday 8: am to 5: pm, EST or send an email to orders@advill.com. Company Information Advanced Illumination 44 State Garage Road, Rochester VT. 5767 Phone: 82.767.383 Fax: 82.767.383 Email: info@advancedillumination.com Web: advancedillumination.com 25 Advanced Illumination Inc. All rights reserved 5