to get there. together. Infrared Sources Swiss made

Similar documents
Laser Gas Detection OEM Gas Sensing Solutions

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Dated 15-Dec-2000; J. Schilz, subject to change

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Thermopile Sensor TPS 230 / 3365

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Sensirion Sensor Solutions. Humidity and Temperature Liquid Flow Gas Flow Differential Pressure

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Spectrum Detector, Inc.

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

Temperature dependent Components within the Pyroelectric Detector

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

gray Laser Power Detectors For fast and accurate measurements

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Sensors for Cell Phones

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Basics. Conversion principle and parameters of pyroelectric detectors

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Key Features. General Description

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Autonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll

Recalibrate the way you look at gas detection

Technological advances within the field of micro multisensors: A Nordic perspective

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Lamp Supply (Recommended)

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

APPLICATION NOTE. 1. Introduction Application Considerations

COMPANY PRESENTATION. 1. June 2016

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

OMA-300 Process Analyzer

Solder joints point to point. Technology day AB Tehnik 2016 Technology Day AB Tehnik

User Detection Sensors

Chemistry Instrumental Analysis Lecture 14. Chem 4631

SPECTRAL INSTRUMENTATION

Broadening IR applications through using spectral filters

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

APPLIED. OMA-406R Rackmount Process Analyzer

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

White Paper MEMS Non-Contact Temperature Sensor

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

More Precision. thermometer // Non-contact IR temperature sensors

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

DHM5150 Human Motion Sensor Module User Manual

Innovative Technology for Traditional and Challenging Applications

Exercise 1: IR Transmission and Reception

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

ADPRO PRO Series by Xtralis

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

Improving Productivity, Quality and Security

FRT Multi Sensor Metrology for Wafer Industries

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Complete Gas Analysis

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

SILICON V-GROOVE ALIGNMENT BENCH FOR OPTICAL COMPONENT ASSEMBLY

The Optical Scattering Calibration System at SNO+ IOP 2015

DESCRIPTION AND SPECIFICATION

Challenges in industrial point sensing- NDIR John Saffell

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Mark Farries. Gooch & Housego

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

SprintIR -6S CO2 Sensor

GAS PLUS ALARM SYSTEM

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Uncooled Infrared Imaging: Higher Performance, Lower Costs

OPTICAL FIBER SOLUTIONS

Company profile and Products

Dräger Flame 2500 Flame Detection

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

FUNCTIONAL SAFETY MANUAL

CO 2 Laser. High Reliability and Performance

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

KERONE (AN ISO 9001: 2008 CERTIFIED COMPANY)

Danfoss gas detection units

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Technical specifications of FT-IR Spectrometer

Transcription:

to get there. together. Infrared Sources Swiss made

p. 2 www.axetris.com

Overview Axetris infrared (IR) sources are micro-machined, electrically modulated thermal infrared emitters featuring true black body radiation characteristics, low power consumption, high emissivity and a long lifetime. The appropriate design is based on a resistive heating element deposited onto a thin dielectric membrane which is suspended on a micro-machined silicon structure. The sources are packaged in compact cans and are available with protective cap or with reflector. They can be fitted optionally with Sapphire, CaF₂, BaF₂ or Germanium broadband filters. Axetris IR sources are ideally suited for compact IR gas detection modules where a high emissivity, high reliability and low power consumption are key requirements. IR Source MEMS chip Table of contents Technology Highlights & Applications 4 Product Portfolio 5 Electrical / Optical Characteristics 6 Benefits 7-9 Main Measurement Principles 10 IRS LabKit 11 Axetris A Company of the Leister Group p. 3

Technology Highlights & Applications Technology highlights True black body radiation (2 to 14 μm) High emissivity Fast electrical modulation (no chopper wheel needed) High modulation depth High electrical input to optical output efficiency Low power consumption Long lifetime Rugged MEMS design (passed the requirements of IEC 60721-3-7 Class 7M3, except for BaF₂ and CaF₂ broadband filters) Measurement principles n-dispersive InfraRed spectroscopy (NDIR) Photo-Acoustic Spectroscopy (PAS) Attenuated Total Reflectance spectroscopy (ATR) Target gases CO, CO₂, VOC, NO x, NH₃, SO x, SF₆, hydrocarbons, humidity, anesthetic agents, refrigerants, breath alcohols Applications Medical: Capnography, anesthesia gas monitoring, respiration monitoring, pulmonary diagnostics, blood gas analysis Axetris IR sources are available in a variety of packages, and have options for a range of reflectors and broadband filters. Industrial: Combustible and toxic gas detection, refrigerant monitoring, flame detection, fruit ripening monitoring, SF₆ monitoring, semi-conductor fabrication Automotive: CO₂ automotive refrigerant monitoring, alcohol detection & interlock, cabin air quality Environmental: Heating, ventilating and air conditioning (HVAC), indoor air quality and VOC monitoring, air quality monitoring p. 4 www.axetris.com

Product Portfolio Type EMIRS200 *WD (top of refl.)/ Power in < 20 angle Broadband filter Cap / Reflector Measurement principles/ Typical application Product photo Chip on Header 12% Custom specific absorption cells Standard TO-Cap 12% CAP 0-53/40-0 STD absorption cells Low Profile TO-Cap 12.3% CAP 0-45/28-0 STD absorption cells Standard Reflector 1 5 15 mm / 60% Yes REF W-55/40-0 NDIR, ATR / STD absorption cells Standard Reflector 2 0 7 mm / 54% REF W-40/43-0 NDIR, ATR / Short absorption cells Standard Reflector 3 10 30 mm / 82% Yes REF W-90/151-0 NDIR, ATR / Long absorbtion cells Ø 10 mm Standard Reflector 4 15.7% Yes CAP W-36/12-0 STD absorption cells EMIRS50 TO-46 Chip on Header 12% Customer specific absorption cells TO-46 Standard TO-Cap 12% CAP 0-30/25-N-0 Standard absorption cells TO-46 Standard Reflector 5 17% Yes CAP W14/13-0-0 Standard absorption cells TO-46 Standard Reflector 6 10 30 mm / 81% REF W57-50-M-00 Standard absorption cells or open path Customized Products Custom Custom Custom NDIR, PAS, ATR / Custom specific absorption cells The IR source is available with a range of broadband filters shown on page 9. Please contact your sales representative for more information. *Working Distance (top of reflector) Axetris A Company of the Leister Group p. 5

Electrical / Optical Characteristics Parameter Unit Value Min Value Typical Value Max Conditions / Remarks EMIRS200 Electrical cold resistance R C22 Ω 35-55 Electrical hot resistance R H500C Ω 54-89 Heater power P H mw 350 450 550 On-Time state Heater voltage V H V 4.9 5.6 6.3 On-Time state Heater membrane temperature T M C 330 450 500 Turn on time τ on ms - 18 - Turn off time τ off ms - 8 - Frequency Hz 5-50 Lifetime years 10 At temperature <500 C Emissivity ε > 0.85 Mean from 2 to 14 μm Heater area A H mm² 2.1 x 1.8 Housing/TO-header temperature T TOH 40 85 at T A = 22 C EMIRS50 Electrical cold resistance R C22 Ω 22-36 Electrical hot resistance R H500C Ω 32-53 Heater power P H mw 170 187 210 On-Time state Heater voltage V H V 2.5 2.7 3.0 On-Time state Heater membrane temperature T M C 330 463 500 Turn on time τ on ms - 10 - Turn off time τ off ms - 5 - Frequency Hz 10-100 Lifetime years 10 At temperature <500 C Emissivity ε > 0.85 Mean from 2 to 14 μm Heater area A H mm² 0.8 x 0.8 Housing/TO-header temperature T TOH 40 85 at T A = 22 C The on-time state defines the power limitation not the average power. The real values can slightly differ from the shown numbers. p. 6 www.axetris.com

Benefits True black body radiation (wavelength from 2 μm to 14 μm) Microscopic image of the MEMS chip packaged on a TO39 header (left). Temperature distribution of the heated membrane (right). High emissivity A unique thin film process creates a pure black body structure with emissivity close to 1. Black dendritic surface structure Fast electrical modulation and high modulation depth MEMS technology offers the possibility to achieve thin and low-mass membrane with short time constant, enabling IR-source to be modulated at high frequency with high modulation depth. Front and backside of the IR Source MEMS chip EMIRS200 (left), EMIRS50 chip (right) Driven with a constant voltage square-wave drive and measured with a high speed broadband detector. Axetris A Company of the Leister Group p. 7

High electrical input power to optical output efficiency Due to the black surface, the IR source has excellent electrical to optical conversion efficiency. The black body surface guarantees maximized emissivity while the thin membrane is responsible for optimized heat flux. Efficiency optimization by heat flux simulation. Reliability of the MEMS structure The semiconductor MEMS manufacturing technology guarantees high reliability and quality of the IR sources. In addition to the strict quality control system during wafer-level manufacturing, every single IR source is subjected to a final burn-in and test. Lifetime reliability plot for IR Sources in modulated mode with 10Hz (EMIRS200), 30Hz (EMIRS50) with a typ. duty cycle of 62% (dashed line) and CW mode (solid line). The Mean Time To Failure (MTTF) for membrane breakage of the IR source is based on a statistical analysis of lifetime data collected from several years of reliability testing. Reliability of the membrane breakage depends greatly on the type of packaging, the electrical input power and the operating mode. Processed wafer of IRS MEMS-based chips before dicing p. 8 www.axetris.com

Benefits of broadband filters Complements detector filter Eliminates background signal and improves S/N ratio Protects the IR source in harsh environments Prevents parasitic influence of the sample gas (for tightly sealed broadband filter installation) IR source with broadband filter Transmission curves for the different filter types. Application specific design options Axetris offers customized IR sources. Packaging, reflector designs and filter types can be configured for OEM customers to meet their specific product needs. The reflector for example, optimizes the angular distribution of radiation and, therefore, the optical signal. Custom Reflector Optimization of the emission distribution with Zemax Reflectors collimate IR radiation on axis. (red: high emission density per area; blue: low emission density per area). Angular radiation distribution with standard cap and reflectors. Axetris A Company of the Leister Group p. 9

Main Measurement Principles n-dispersive InfraRed (NDIR) principle n-dispersive InfraRed spectroscopy utilizes a broadband infrared source covering the entire wavelength spectrum needed to measure a large variety of gases. The specific wavelengths desired to measure the gas(es) of interest are selected with narrow band pass filters. The radiation is absorbed by the gas resulting in a signal decrease which is proportional to the gas concentration inside the sample volume. Thermopiles or pyroelectric detectors are commonly used for this spectroscopy technique. IR signal gas concentration Photo-Acoustic Spectroscopy (PAS) principle When infrared radiation is absorbed, the absorbing gas is heated. This heating causes a thermal expansion which, in turn, is responsible for a pressure increase in the sample volume. When the radiation is switched off, the gas cools down and the pressure decreases accordingly. With a pulsed IR source, a pressure wave e.g. soundwave is created which can be detected with a microphone. The higher the concentration of the gas of interest (appropriate wavelength has to be chosen with filters), the higher the signal. PAS is not limited to gases but can also be applied to liquids and solids. sound signal gas concentration Attenuated Total Reflectance (ATR) principle When radiation is totally reflected from an interface a small part of it will be transmitted into the adjacent medium. This evanescent wave experiences an exponential decay with penetration depths in the order of the wavelength. The amount of light that is coupled into this evanescent wave depends on the difference of refractive indices of the two adjacent media. In ATR spectroscopy, a crystal made of a high refractive index material serves as the light guiding medium. The sample, usually a liquid, is brought into contact so that the evanescent wave can interact with it. The appropriate wavelength is chosen with a narrow band pass filter. Depending on the state or quality of the sample, more or less light is coupled out and the signal on the detector then changes accordingly. Line arrays of thermopiles or pyroelectric detectors are frequently applied gas concentration in these setups. IR signal p. 10 www.axetris.com

IRS LabKit Faster and easier design-in of Axetris IR Source Very efficient tool for evaluating the ideal drive mode for achieving the best signal/noise ratio Quick and easy start-up and measurement within minutes Includes everything you need Simple Graphical User Interface (GUI) based on LabVIEW software Set and update all drive parameters live from the GUI Live diagram plots for data display and recording Visualized drive mode limitations (recommendations) Export of bitmap and Excel data Graphical User Interface (GUI) Direct connection to a PC with RS232 protocol and USB TO socket and connector for external IR source connection I/O analog interface for detector synchronization and signal evaluation IRS LabKit driver board Parameter Unit Value Conditions / Remarks Drive Modes P / V / I CW / Wave signal Power control P mw 50 800 Power regulated Voltage control V V 0.5 10 Voltage regulated Current control I ma 5 100 Current regulated Waveform signal CW / SQ Wave Signal Frequency Hz 0 (CW), 4 50 Duty cycle % 5 90 Analog I/O V 0 5 Synchronization of detector circuit, detector signal recording Axetris A Company of the Leister Group p. 11

About Axetris AG Axetris serves OEM customers with micro-optical components, micro technology-based (MEMS) infrared light sources, mass flow meters and controllers, and laser gas detection modules used in industrial, telecom, environmental, medical, analytical and automotive applications. Our multi-disciplinary and highly skilled engineering and manufacturing teams combine broad experience in design, manufacturing and metrology from MEMS components to advanced optical and electronic sensor modules. Axetris supports its customers with in-depth application know-how. Customers benefit from excellent product value, consistent high product quality and outstanding customer support. OEMs rely on Axetris worldwide as a competent partner for customer-specific solutions from concept to volume production. Axetris is ISO 9001:2015 certified and operates its own 6-inch to 8-inch wafer MEMS foundry for its own products and contract manufacturing for external customers. A wafer back end, a sensor assembly and calibration facility under clean room conditions completes the manufacturing infrastructure of Axetris. Corporate Headquarters of the Leister Group, Switzerland Contact Switzerland USA China Japan Axetris AG (Headquarters) 6056 Kaegiswil phone +41 41 662 76 76 axetris@axetris.com www.axetris.com Leister Technologies LLC Itasca, IL 60143 phone +1 844 293 8747 axetris.usa@axetris.com www.axetris.com Leister Technologies Ltd. Shanghai 201 109 phone +86 21 6442 2398 axetris@axetris.cn www.axetris.cn Leister Technologies KK Shin-Yokohama 222-0033 phone +81 45 477 36 37 axetris@axetris.jp www.axetris.jp Swiss Made Quality. Axetris is an ISO 9001:2015 certified enterprise.