Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

Similar documents
The smart way to instant hot water comfort.

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Systems and Plumbing Products

Taco 00 Series Cartridge Circulators

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

GRUNDFOS PLUMBING & HVAC PRODUCTS

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

POULTRY MARKET CATALOG

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

hydronic S Y S T E M S & C O M P O N E N T S

Astro Express 2 - Hot Water Delivery System

Family of Circulators

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Indirect Fired Water Heater

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

In-Line Air Separators

Hydronic Accessories

Machine Tool Coolant Units

PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com

Instruction Sheet RMB - Radiant Mixing Block

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

1900 Series In-Line Pump

Hydronic Mechanical Panels

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Hydronic Specialties and Circulator Pumps

Tube Clamp Submittal Information Revision A: July 25, 2013

FI / SFI Frame-Mounted End Suction Pumps

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

Automatic Temperature Controller (ATC)

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

MACH N-407 Heat Pump Air-Cooled Chiller

Honeywell Water Solutions. Thermostatic Mixing Valves

Heat Pumps COMFORT NEED IT. When You

Heat Pump Water Heater. Table of Contents

Home. One Source For All Your Potable Water Needs

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Technical Data Manual Model Nos. and pricing: see Price List

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

MAC N-407 Air-Cooled Chiller

ACT D MAND KONTROLS System FACTS AND QUESTIONS (FAQ)

Hydronic Heating and Plumbing Products

Grundfos is pleased to announce the sales release of many exciting new products.

Hot-Water Circulation

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

CHUGGER PUMP Chugger Max Models

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

5. CONDENSATE PUMPS/UNITS

Canadian Retail. Parts Catalogue

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Canadian Retail. Parts Catalogue

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

EXTROL EXPANSION TANKS

Hydronic Heating and Plumbing Products

Hydronic Heating and Plumbing Products

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

INSTANT HOT WATER RECIRCULATING SYSTEM

Hydronic Heating and Plumbing Products

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PAL Cyclone Pump 2100GPH / 33 Ft. Cord

Tepid Water Delivery System

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Instruction Sheet X Pump Block (XPB)

ecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price:

Cool IR. Model C104 - Cooling System. Instruction Manual

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

ASSE 1017 Point of Source Commercial. Mixing Valves. Mixing Valves. MVA (34A) Series/MVAH Hydronic Series

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

INSTANT-FLOW C-MICRO WATER HEATER

Standard Features & Accessories. Model Options

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

KEENER GRINDER PUMPS

ultracirc Domestic hot water / Sanitary pumps Instant hot water at every faucet More comfort Saves water and energy

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

VERTICAL FAN COIL UNITS

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

Comfort Series Instant Hot Water System

INSTANT-FLOW C-MICRO WATER HEATER

ECO1ZN3P, ECO2ZN4P ECO

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

*RENTAL* Explosion Proof Portacool Portable Evaporative Cooler - C1D1 - Water Mist Cooler - 30" OD

TYPE LF/LC/LCV END SUCTION PUMPS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

10-MINUTE "EXPERT" dahl Edition

HYDROPONICS INDOOR GARDENING PRODUCTS

Owner s Manual Therma-Stor II Heat Recovery System

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

ph COOLING TOWER CONTROLLER

Transcription:

Plumbing ECM High-Efficiency Hot Water Recirculation System Enjoy instant hot water comfort while avoiding a major renovation. The Hot-LinkPlus-e system installs easily into existing plumbing with a tank water heater. No dedicated hot water return line is needed! The system combines the ECM high-efficiency 006e3 hot water circulator with the award-winning SmartPlug Instant Hot Water Control and Hot-Link for maximum comfort and efficiency. Enjoy water savings of up to 12,000 gallons per year. You can expect trouble-free performance reinforced by SureStart automatic unblocking and air purging. Ideal for retrofits, the Hot-LinkPlus-e requires no programming and is built with the reliability that s made Taco famous. Install it, forget it. Instant hot water for existing plumbing systems; no dedicated return line needed Taco Catalog # 100-153 Supersedes: New Effective Date: 02/27/18 Printed in USA

A bundle of efficiency for instant hot water when you need it. Hot-LinkPlus-e 006e3 ECM Circulator Taco trusted 00e series quality and reliability Install it, forget it. 13 Shut-off head, 11 gpm max flow Easy to use dial: - Low, Medium, High - 003 & 006 performance point references Easy installation: - Compact design for tight spaces - Multiple connection options available High-efficiency ECM motor uses up to 85% less electricity SureStart automatic unblocking and air purging mode Whisper quiet operation ¾ NPT male & female union fitting set included Double insulated, no ground wire required Includes a 6ft. power cord Dial Setting Set dial to the 006 performance point NOTE: Figures are for reference purposes only. Refer to ASTM guidelines for piping flow and velocity standards. For PEX, refer to pipe manufacturer guidelines. Includes 6ft. power cord, fittings and braided hose connections.

Hot-LinkPlus-e SmartPlug Instant Hot Water Control Application: The Taco Hot-LinkPlus-e SmartPlug is designed to upgrade any domestic plumbing system. It adds intelligence to your system by learning when hot water is used in the home. The pipe-mounted temperature sensor records daily hot water usage patterns during the course of a week. Recorded data is used to automatically run the 006e3 at the same times the following week. So hot water is always available when it's needed. If your usage pattern changes, the SmartPlug adjusts automatically. No programming required. Benefits: Easy to install: Upgrades your existing plumbing to provide "Smart" hot water. Water conservation: The average residence can save up to 12,000 gallons* of water per year by eliminating the wait for hot water to arrive at fixtures and taps. Hot-LinkPlus-e SmartPlug Control Options & Features: Smart Mode: When set to "Smart" mode, the SmartPlug monitors and records the home's hot water usage pattern over a 7 day period. The SmartPlug will use the preceding week's usage pattern to automatically cycle the 006e3 ON, so hot water is always available when it's needed. The recording and repeating process is continuous, week after week. Pulse Mode: When set to "Pulse" mode, the SmartPlug will continuously cycle the 006e3 ON for 5 minutes, then OFF for 10 minutes to maintain hot water at all fixtures. Vacation Mode: After 36 hours of no hot water usage, the SmartPlug will automatically turn the 006e3 OFF and remain off until hot water usage is detected. Exercise Function: While in vacation mode the SmartPlug will cycle the 006e3 for 10 seconds every 7 days to prevent any corrosion or scale build up. LED Indicator lights: Green: Power Yellow: Mode Setting Red: Error code diagnostics Comfort and convenience: Hot water is available in seconds. No timers or programming required. Efficiency: Smart setting maximizes hot water comfort and energy savings. Reliability: The HotL-LinkPlus-e SmartPlug and 006e3 provide whisper quiet operation and industry leading electronics for proven performance and dependability. * Source: Department of Energy study Simple installation

Hot-LinkPlus-e Hot-Link Hot water without the waste! Installation is a snap using your existing plumbing. The Hot-Link bypass valves unique thermal disk technology sends cooled water back to the water heater so hot water lines remain hot. Install the Hot-Link bypass valve at the faucet furthest away from the water heater. Then install the 006e3 circulator at the water heater. From Water Heater To Water Heater Hot-Link Closed Hot-Link Open Save up to 12,000 gallons per year water that normally goes down the drain while waiting for hot water. Exclusive clean in place undersink valve design

Submittal Data Information Hot-LinkPlus-e Submittal Data # 101-203 Effective: 02/27/18 006e3 Specifications Maximum Shut-off Head: 13 feet Maximum Flow: 11 gpm Maximum Operating Pressure: Maximum Water Temp: 203 F (95 C) Minimum Water Temp: 36 F (2 C) Electrical Specifications: Voltage: 120V, 60 Hz Single phase Max. Operating Power: 44W Max. AMP Rating: 0.54 150 psi (10 bar) Equipped with a composite casing designed for open loop potable water systems and closed hydronic systems Not suitable for chilled water Taco circulator pumps are for indoor use only Acceptable for use with water or maximum of 50% water/glycol solution in closed hydronic systems ISO 228-G1 (DIN 259/BS 2779) G System Model Number Pump Dimensions & Weights Model Number (Part Number) 006e3LC VM1212-DY1-UP2A01 Mounting Positions F D C HLPe-1 A B A B C D F G Ship Wt. in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg 5-1/2 140 4-7/8 124 2-5/8 67 3-1/4 82 5-1/8 130 5-1/8 130 3.5 1.6 006e3 Materials of Construction Casing:... Composite Stator Housing:... Composite Cartridge:... Composite Impeller:... Composite Shaft:... Ceramic Bearings:... Carbon Thrust Bearing:... Ceramic O-Ring & Gaskets:...EPDM Electrical Data Model Volts Hz Ph Max.Amps Watts RPM All Models 120 60 1.54 44 1440-3720 Motor Type ECM, Permanent Magnet, Thermally Protected SmartPlug Specifications Input: 120VAC, 50/60HZ, single phase, 6A Output: 120VAC, 50/60HZ, Single phase, 1/2 hp (limited to 6 FLA, 36LRA) Hot-Link Dimensions & Weights: Connection A B C D Ship Wt. in. mm in. mm in. mm in. mm Lbs. Kg 1/2 MNPT 4 102 4-7/16 87 1-3/4 41 2-1/2 64 0.37 0.17 : NTC Thermistor, 10K ohm @ 77 F, B= 3392 Fuse: 125V, 6A, Medium Acting 5x20 mm glass, Littelfuse p/n 0233006 mxp Ambient Operating Temp: 50-104 F, 10-40 C B A C Hot-Link Materials of Construction Body...Nylon Thermal Disk Actuator...Bi-Metal O-Ring Seals... EPDM SmartPlug SmartPlug Components Connector Strap A D MINIMUM AREA REQUIRED TO MOVE STEM C Integral Flow Check (IFC ): Body, Plunger... Acetal O-Rings...EPDM Screen...304 SS Stem...Nylon Actuator Cartridge...Stainless Steel Braided Flex Hoses...Stainless Steel B D MINIMUM AREA REQUIRED TO MOVE STEM FOR INDOOR USE ONLY

Typical Installation (FOR REFERENCE ONLY) Hot Cold Hot Cold HOT COLD Optional 2 nd Hot-Link location (2) New 1/2 x1/2 Taco supplied flex lines (female to female) The furthest fixture from the water heater is preferred HOT COLD Hot-Link includes (2) plastic wall anchors & screws 1/2 1/2 WATER SUPPLY HOT WATER LINE Use (2) existing 3/8 x1/2 female to female flex lines COLD WATER LINE SmartPlug Strap Cold Inlet Mixing 006e3 ECM Circulator SmartPlug Water Heater Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436 www.tacocomfort.com