Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Similar documents
Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Assistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T.

THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER

Experimental Investigations on Packed Bed Solar Air Heater

Thermo-Hydraulic Performance Evaluation Using W-Discrete Rib in Solar Air Heater

Design and Fabrication of Solar Air Heater to Increase Heat Transfer Rate using Artificial Roughness

Design and Thermal Analysis of Solar Plate Collector with and Without Porous Medium

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

2. HEAT EXCHANGERS MESA

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Performance Analysis for the Double- Pass Solar Air Collector with and Without Porous Media

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Performance analysis of overlapped solar air heater using CFD

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Global Journal of Engineering Science and Research Management

A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS

Performance Evaluation of Hybrid Solar Water Heating System Using Wire Screen Packed Solar Air Heater

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Performance Study of Triple Concentric Pipe Heat Exchanger

Falling Film Heat Exchangers for Solar Water Heaters

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Performance Analysis of Solar Air Heater Using Three Wire Mesh

Greek Symbol η collector efficiency Rim angle

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

ENSC 388: Engineering Thermodynamics and Heat Transfer

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

6340(Print), ISSN (Online) TECHNOLOGY Volume 3, Issue (IJMET) 2, May-August (2012), IAEME

Compression of Fins pipe and simple Heat pipe Using CFD

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

American International Journal of Research in Science, Technology, Engineering & Mathematics

Enhancement of COP in Vapour Compression Refrigeration System

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

THE PERFORMANCE STUDY OF A SOLAR FLAT PLATE TYPE AIR COLLECTOR WITH NATURAL AND FORCED CONVECTION

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

1, 2

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Modified Air Cooler with Split Cooling Unit

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Heat Transfer Enhancement in Shell and Tube Condenser

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Design and Development of Water Cooled Condenser for Domestic Refrigerator

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

a Heat Exchanger using FEA Tool

To investigate the surface properties for increasing efficiency of solar water heater

International Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October

Experimentation of Heat Pipe Used In Nano-Fluids

ANALYSIS OF THERMAL PERFORMANCE OF SOLAR AIR DRYER FOR THREE DIFFERENT ABSORBER PLATES

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Investigation and Optimization of Air Cooled Condenser of Chillers by Replacing Cu to Al Tubes

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

LAB EQUIPMENT DETAILS

Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

EXPERIMENTAL EVALUATION OF CONDENSATION HEAT TRANSFER COEFFICIENT OF R-417A IN HORIZONTAL TUBES

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

A Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Design, Development and Experimental Investigation of Volumetric Air Receiver

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

SCIENCE CHINA Technological Sciences

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Transcription:

Research Paper EFFECT OF ELLIPTICAL INCLINED DIMPLES ON NUSSELT NUMBER AND FRICTION FACTOR FOR ARTIFICIALLY ROUGHENED DUCT OF SOLAR AIR HEATERS Raman Kumar a, Harvinder Lal b Address for Correspondence Department of Mechanical Engineering, Ramgarhia Institute of Engineering and Technology (RIET) Phagwara, Punjab, India ABSTRACT An experimental investigation has been carried out for a range of system and operating parameters in order to analyze effect of artificial roughness on heat transfer and friction in solar air heater duct having inclined dimples as roughness geometry. An increase in heat transfer and friction loss has been observed for duct having roughened absorber plate. Experimental data have been used to develop Nusselt number and friction factor correlations as function of system and operating parameters for predicting performance of the system having investigated type of roughness geometry. The aspect ratio of the duct is of order (W/H =10) and the range of Reynolds number is (8000 25000). KEY WORDS: Solar air heater, artificial roughness, heat transfer coefficient, Nusselt number and friction factor. India INTRODUCTION Energy is a basic need for human being; it is a prime agent in the generation and economic development. Energy resources may be classified in two ways conventional and non-conventional energy resources. Solar energy is available abundance on earth in the form of radiation. Solar energy is used for heating application and converts it into thermal energy. Solar air heater is the cheapest way of converting solar energy into thermal energy solar air heaters form the major component of solar energy utilization system which absorbs the incoming solar radiation, converting it into thermal energy at the absorbing surface, and transferring the energy to a fluid flowing through the collector. Solar air heaters because of their inherent simplicity are cheap and most widely used collection devices. These have found several applications including space heating and crop drying. The efficiency of flat plate solar air heater has been found to be low because of low convective heat transfer coefficient between absorber plate and the flowing air which increases the absorber plate temperature, leading to higher heat losses to the environment resulting in low thermal performance. Thermal Performance of solar air heaters is comparably poor from solar water heaters. Thermal performance may be increased by increasing convective heat transfer coefficient. There are two way for increasing heat transfer coefficient either increase the area of absorbing surface by using fins or create the turbulence on the heat transferring surfaces. Turbulence can be increased by artificial roughness. Artificial roughness is basically a passive heat transfer enhancement technique by which thermo hydraulic performance of a solar air heater can be improved. The artificial roughness has been used extensively for the enhancement of forced convective heat transfer, which further requires flow at the heat transferring surface to be turbulent. However, energy for creating such turbulence has to come from the fan or blower and the excessive power is required to flow air through the duct. Therefore, it is desirable that the turbulence must be created only in the region very close to the heat transferring surface, so that the power requirement may be lessened. Several investigations have been carried out to study the effect of artificial roughness on heat transfer and friction factor for two opposite roughened surfaces and the correlations were developed by different investigators The application of artificial roughness in the form of fine wires on the heat transfer surface has been recommended to enhance the heat transfer coefficient by several investigators When a fluid enters in closed channel at a uniform velocity, the fluid particles in the layer in contact with wall of the channel come to complete rest. This layer also causes the fluid particles in the adjacent layers to slow down gradually as result of friction. To make up this velocity reduction, the velocity of the fluid at the midsection of the rectangular duct has to increase to keep the mass flow rate through the rectangular duct constant. As a result, velocity gradient develops along the channel. Due to roughness element lies under the absorber plate, the flow becomes turbulent because of reattachment point or brakeage of hydrodynamic boundary layer at regular interval. In this phenomenon heat transfer coefficient, friction factor and pumping power of fluid increase through this artificial roughened rectangular duct. The effect of roughness and operating parameters on the heat transfer coefficient has been examined and a comparison of performance of roughened solar air heater with that of conventional solar air heater having smooth duct has been made. The heat transfer coefficient of a solar air heater can be increased by providing artificial roughness on the underside of the absorber plate. An experimental investigation has been carried out in the present work to study the heat transfer by using inclined elliptical dimples on the underside of absorber plate of a solar air heater under simulated conditions. Artificial roughness can be produced by several methods such as by Casting, welding and wire fixation in the form of transverse continuous ribs, transverse broken ribs, inclined and V-shaped or staggered ribs; rib formation by machining process in the form of chamfered ribs, wedge shaped ribs, combination of different integral rib roughness elements and by using expanded metal mesh ribs as has been described by Bhushan and Singh [2]. Gupta [15] et al. reported effect of transverse wire roughness on heat and fluid flow characteristics for solar air heater ducts with an absorber plate having transverse wires fixed on its underside. Muluwork et al. [5] compared thermal performance of staggered discrete V-apex up and down with corresponding transverse staggered discrete ribs. Momin et al. [8] experimentally investigated effect of geometrical parameters of V- shaped ribs on heat transfer and fluid flow

characteristics in rectangular duct used in solar air heaters. Jaurker et al. [9] experimentally investigated heat transfer and friction characteristics of ribgrooved artificial roughness. Saini and Saini [10] used expanded metal mesh to create artificial roughness on absorber plate and investigated effect of system and operating parameters on heat transfer and friction loss. Karwa et al.[16] performed experimental study to predict the effect of rib head chamfer angle (φ) and duct aspect ratio on heat transfer and friction factor in a rectangular duct roughened with integral chamfered. Bhushan and Singh analyzed the effect of artificial roughness on heat transfer and friction in solar air heater duct having protrusions as roughness geometry. Varun et al. [11] presented a review on artificial roughness investigations reported in literature. Pardeep et al. [12] investigated the effect of streamlined dimples on roughened absorber plate. It has been revealed from various experimental investigations reported in literature that inclined elliptical dimples as artificial roughness is a good technique for enhancing heat transfer coefficient between absorber plate and air flowing in the duct. However, it results increase in friction loss, due to increase in degree of turbulence in flow regimes, which hamper economical violability of solar air heaters. In order to overcome this problem, an experimental investigation has been carried out in the present work to study the heat transfer and friction loss by using inclined elliptical dimples in the form of protruded dimples on the underside of absorber plate of a solar air heater for a range of system and operating parameters. EXPERIMENTAL SET-UP AND PROCEDURE A test rig has been designed and fabricated to generate experimental data which consists of air duct (2400 mm x 840 mm x 70 mm) is made up of wooden ply board of 20 mm thickness with length of entry, test and exit sections are 900 mm, 1000 mm and 500 mm respectively. Schematic and photographic views of experimental set-up are shown in Fig. (1) and Fig. (2) Respectively. The air duct is provided with temperature and pressure drop measuring instruments along with mounted electric heater assembly, converging plenum of length 500 mm was provided on exit side of the duct. Electric heater (2400 mm x 840 mm) have been placed on top of the duct being fabricated by combining series and parallel loops of heating wire on mica sheet to get uniform heat flux. Backside of the heater was insulated with glass wool to minimize the heat loss. Variac (0-250V) was provided to control electric supply to the electric heater. Absorber plate (20 SWG GI sheet) of size 2400 mm x 880 mm have been provided with streamlined protruded dimples (artificial roughness element) on air duct side. An orifice-meter with U-tube manometer was used to measure the mass flow rate of the air. Two gate valves one at entry and other at exit of centrifugal blower has been installed for smooth controlling of flow of air through the duct. Copper-constantan thermocouples were used to measure temperature of air and absorber plate at different locations as shown in Figs. (3) and (4). Pressure drop across test section of the duct has been measured with micromanometer. Photographic view of dimpled plate used in the present experimental investigation is shown in Fig. (5). Fig.1: Schematic of experiment set up. Fig.2. Photographic view of experimental set- up Table 1 shows range/value of parameters used in present experimental investigation. Streamlined protrusion is protruded on the underside of the absorber plate. All measuring instruments and equipments like orifice meter, temperature indicator, and temperature selector switch, micro manometer and U-tube manometer were properly inspected before starting the experimentation and any leakage in joints of the test rig, joints were proper filled with glue. Five values of flow rate were used for each set and following data were collected at an interval of one hour in each set of experimentation: Pressure drop across orifice meter to measure flow rate of air. Pressure drop across test section of duct. Temperature of absorber plate at various locations in test section of the duct. Temperature of air at various locations in test section of the duct. Voltage and current supplied to electric heater. Table 1: Range / Value of parameters Accuracy of experimental data was verified by conducting experiments for a conventional smooth duct. Nusselt number and friction factor values were determined from experimental data and compared with the values obtained from the following Nusselt number and friction factor correlations reported by Momin et al. [8] for rectangular smooth duct. Dittus- Boelter correlation for Nusselt number is Nu s = 0.023 Re 0.8 Pr 0.4 (1) Blasius equation for friction factor is 0.25 f s = 0.085 Re (2) Fig. (12) and Fig. (13) Shows comparison of Nusselt number and friction factor for smooth absorber plate. A reasonably good data ensures accuracy of the data

being collected from self designed and fabricated experimental set-up. Error analysis based on the procedure described by Holman [12] has been carried out to find out uncertainties in measured/calculated values of experimental data. Uncertainty in Reynolds number, Nusselt number and friction factor values has been estimated as 2.45%, 2.34%, and 3.04% respectively. Fig.3. Different locations of thermocouples used to measure absorber plate temperature. Fig.4: Different locations of thermocouples used to measure air temperature in the duct. Fig. 5: Photographic view of inclined dimpled metallic plate Data Reduction Following equations were used for calculating pressure drop across test section m& and orifice plate ( P t and P o ), mass flow rate of air (m), velocity of air (V), heat transfer rate (q), heat transfer coefficient (h), Nusselt number (Nu) and friction factor (f): P = ρ g ( h ) (3) t k t P = ρ g h (4) o w w 2ρ Po Sinθ m& = C d Ao 4 1 β (5) m V = & ρ A (6) c q= mc & T T (7) p o i Also q = ha T T (8) c pm am Therefore, from Eq. (7) and (8) h A q = (9) ( T T ) c pm am Where T pm and T am are mean temperature of absorber plate and air. These were determined from temperature values recorded for absorber plate and air at different locations along test section of the duct. Reynolds number, Nusselt number and friction factor values were calculated by using the following relationships: ρvd Re = (10) µ hd Nu = (11) k 2 Pt D f = (12) 2 4ρ LV RESULTS AND DISCUSSION 0.5 Variation of heat transfer coefficient as a function of mass flow rate of air for smooth and roughened absorber plate is shown in Fig.10. It is noted that heat transfer coefficient is very low for lower values of mass flow rate of air, but increases as mass flow rate of air increases. It may have happened due to turbulence caused by roughness elements in the laminar sub-layer only. Variations of Nusselt number as a function of Reynolds number for smooth and roughened absorber plate is shown in Fig.9. It has been observed that Nusselt number increases consistently with positive slope for entire range of Reynolds number. Also, Roughened plate has shown higher Nusselt number values than that of smooth plate, due to mixing of flow and generation of secondary flows in flow regimes similar to as reported by Saini and Saini [10] for expended metal mesh. Pressure drop increases with rise of mass flow rate of air for roughened and smooth plate as shown in Fig. 12. It is also observed that pressure drop is higher in case of plate roughened with l/e =20 for entire range of mass flow rate of air, due to increase in degree of turbulence in flow regimes, because of presence of roughness element in the duct. Variation of friction factor as a function of Reynolds number for smooth and roughened plate is shown in Fig.11.Mixing of flow may be responsible for higher friction factor for roughened plate as compared to the smooth plate. Fig.9: Effect of Reynolds number on Nusselt number. Fig.10: Effect of mass flow rate on heat transfer coefficient Fig.11: Effect of Reynolds number on fiction factor.

Fig.12: Effect of mass flow rate on pressure drop. Fig.13: Experimental and predicted Nusselt number and Reynolds number. Fig.14: Experimental and predicted Friction factor and Reynolds number. Nomenclature CONCLUSION An experimental investigation on performance of artificially roughened duct used in solar air heaters has been reported in the present paper. Effect of artificial roughness (created by inclined elliptical dimples on absorber plate) on heat transfer and friction has been investigated for Reynolds numbers range of 8000 25000. It has been observed that roughened absorber plate results into higher heat transfer coefficient at the cost of frictional penalty. In order to predict performance of the system thermal efficiency and effective efficiency for roughened solar air heater has been found of the order of 2.3 and 1.9 times respectively as compared to solar air heater having smooth absorber plate. ACKNOWLEDGEMENT The author would like to express a deep sense of gratitude and thanks to Er. Harvinder Lal, Associate Professor and Head, Department of Mechanical Engineering, Ramgarhia institute of Engineering and Technology (RIET), PHAGWARA for their valuable guidance, persistent encouragement and suggestions at every stage of my dissertation. Without able guidance and wise counseling, it would have been impossible to complete the research work in this manner. The author is highly grateful to Principal, Er. R. K Dhawan RIET PHAGWARA for providing moral support and help in each aspect to carry out the present research work. I am deeply indebted to my parents for their best wishes and co-operation extended throughout the work duration. Finally, the author is indebted to all whosoever have helped directly or indirectly in this dissertation work and for friendly stay at RIET Phagwara. REFERENCES 1. Kumar P., Singh S., Mahajan.T., Effect of Relative long-way length on Nusselt number and Friction factor of streamlined dimpled artificially roughened duct solar air heater, Int. J. of Adv. Engg. Tech., IV (2013) 57-60. 2. T. Mahajan, R. Singh, B. Bhushan, Performance Investigation Of Artificially Roughened Duct Used In Solar Air Heaters 3. B. Bhushan, R. Singh, A review on methodology of artificial roughness used in duct of solar air heaters, Energy, 35 (2010) 202-212. 4. K. Prasad, S.C. Mullick, Heat transfer characteristics of a solar air heater used for drying purposes, Appl. Energy, 13 (1983) 83-98. 5. B.N. Prasad, J.S. Saini, Effect of artificial roughness on heat transfer and friction factor in solar air heater, Solar Energy, 41 (1988) 555-560. 6. K.B. Muluwork, J.S. Saini, S.C. Solanki, Studies on discrete rib roughened solar air heaters, In: Proceedings of National Solar Energy Convention-98, Roorkee, India, pp, 75-84, and 1998. 7. R. Karwa, S.C. Solanki, J.S. Saini, Heat transfer coefficient and friction factor correlations for the transitional flow regime in rib roughened rectangular ducts, International Journal of Heat and Mass Transfer, 42 (1999) 1597-1615. 8. J.L. Bhagoria, J.S. Saini, S.C. Solanki, Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge

shaped rib roughness on the absorber plate, Renewable Energy, 25 (2002) 341-369. 9. A.M.E. Momin, J.S. Saini, S.C. Solanki, Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate, International Journal of Heat and Mass Transfer, 45 (2002) 3383-3396. 10. A.R. Jaurker, J.S. Saini, B.K. Gandhi, Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness, Solar Energy 80 (2006) 895-907. 11. R.P. Saini, J.S. Saini, Heat transfer and friction factor correlations for artificially roughened ducts with expanded metal mesh as roughened element, International Journal of Heat and Mass Transfer, 40 (1997) 973-986. 12. Varun, R.P. Saini, S.K. Singal, A review on roughness geometry used in solar air heaters, Int. J. Solar Energy, 81 (2007) 1340-1350. 13. J.P. Holman, Experimental methods for engineers, Tata McGraw-Hill, New Delhi, 2004. 14. R. Singh, R.P. Saini, J.S. Saini, Nusselt number and friction factor correlations for packed bed solar energy storage system having large sized elements of different shapes, Solar Energy, 80 (2006) 760-771. 15. S.K. Verma, B.N. Prasad, Investigation for the optimal thermo-hydraulic performance of Artificially roughened solar air heaters, Renewable Energy, 20(2000) 19 36. 16. Gupta, D., Solanki, S.C., Saini, J.S., 1993. Heat and fluid flow in rectangular solar air heater ducts having transverse rib roughness on absorber plates. Solar Energy 51, pp 31-37. 17. Karwa, R., Solanki, S.C., Saini, J.S., 1999. Heat transfer coefficient and friction factor correlations for the transitional flow regime in rib roughened rectangular ducts. International Journal of Heat and Mass Transfer 42, 1597 1615