Product Information and Technical Guide

Similar documents
Product Information and Technical Guide

Product Information and Technical Guide

Product Information and Technical Guide

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

Product Information and Technical Guide

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

APARTMENT MAINTENANCE SERIES

Fast Track Troubleshooting

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

SERVICE DATA SHEET (9704) Rev. D

! WARNING CAUTION DANGER WARNING CAUTION

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

Product Information and Technical Guide

FFTR1514TW.jpg DRFFTR1514TB0.wmf CAWWTR1611SW0.wmf SHFFTR1614RW0.wmf SYFFTR1514RB1.wmf W eps S eps

Service Manual Electric Cooktop

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Norcold Repair Guide for Ice Maker

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Fast Track Troubleshooting

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

CAUTION. No-Load Performance, Controls in Normal Position

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Fast Track Troubleshooting

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

Fast Track Troubleshooting

FOR SERVICE TECHNICIAN S USE ONLY

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Beverage Air IMPORTANT

CABINET PARTS For Models: ET21MMXJW01, ET21MMXJT01 (White) (Biscuit)

UNIVERSAL SATELLITE DEVICE MINI - CAN VENDOR

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

Fast Track Troubleshooting

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

USER GUIDE. TL6015W TL6018W 60cm Larder

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Fast Track Troubleshooting

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Image Key Part Number Description Substitution Qty.

Automatic Ice Maker. Service Manual VT ICEMAKER 15

Bottom Mount Refrigerator---Technical Information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Repair Parts List REFRIGERATOR MODEL NUMBER GT15B83V. When requesting service or ordering parts, always provide the following information:

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Volts 115 Wiring Diagram Owner's Guide Energy Guide Service Data Sheet Installation Instructions

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

WESTINGHOUSE REFRIGERATOR SIDE BY SIDE FROST FREE V SERIES

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

KAR-5 TECHNICAL EDUCATION KUWS246 WINE CELLAR JOB AID

V Refrigeration Module

CABINET PARTS REFRIGERATOR. For Models:ET21PKXGW03, ET21PKXGT03 (White) (Biscuit) Part No Litho In U.S.A. (cre) 1

FOR SERVICE TECHNICIAN S USE ONLY

TROUBLESHOOTING VANGUARD

V Refrigeration Module

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Instruction Manual. Chest Freezer MODEL: KI130CF2

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

AIR CONDITIONER ELECTRONIC CONTROL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CABINET PARTS REFRIGERATOR. For Models: 8ET1FTKXKT00 (Biscuit) Litho In U.S.A. (mdg) 1. Part No

FOR SERVICE TECHNICIAN S USE ONLY

RPI Industries, Inc.

KM-61BAH KM-101BAH KM-151BAH

POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

SERVICE MANUAL REFRIGERATION

Fast Track Troubleshooting

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KELVINATOR REFRIGERATORS NO FROST H & SH SERIES

InstructIon Manual KrEs EQuIPMEnt stands

REFRIGERATOR MODELS: WRT111SFAW00 (White) WRT111SFAB00 (Black) WRT111SFAF00 (Satina) 11/25/ Whirlpool Corporation Part No. W Rev.

Ice Maker (Fresh Food Compartment)

CABINET PARTS REFRIGERATOR. For Models: GT2SHMXMS01 (Stainless Steel) Litho In U.S.A. (ebk) 1. Part No

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

Owner s Manual Ultimate 340

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)

smeg LARDER Instruction booklet

Quest Dry 105, 155, and 205 Dual

Split Floor-Mounted Cooling System Operation Care Installation Manual

Transcription:

Product Information and Technical Guide Side by Side and Top Mount Refrigerators January 2004 - March 2004 White-Westinghouse 5995413308 July 2004

TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------ 2 Service Data Sheet, Refrigerant Charge & Energy Efficiency Rating Indexes ------------------- 3-7 Troubleshooting Guide --------------------------------------------------------------------------------------------- 8-12 Appendix A - Service Data Sheets 240379007 --------------------------------------------------------------------------------------------------------- A1 - A2 240379011 --------------------------------------------------------------------------------------------------------- A3 - A4 240379012 --------------------------------------------------------------------------------------------------------- A5 - A6 240379013 --------------------------------------------------------------------------------------------------------- A7 - A8 240379014 --------------------------------------------------------------------------------------------------------- A9 - A10 240379015 --------------------------------------------------------------------------------------------------------- A11 - A12 241588200 --------------------------------------------------------------------------------------------------------- A13 - A14 240389613 --------------------------------------------------------------------------------------------------------- A15 - A16 240389615 --------------------------------------------------------------------------------------------------------- A17 - A18 240389016 --------------------------------------------------------------------------------------------------------- A19 - A20 240389618 --------------------------------------------------------------------------------------------------------- A21- A22 241532603 --------------------------------------------------------------------------------------------------------- A23-24 1

SAFE SERVICING PRACTICES - ALL APPLIANCES To avoid personal injury and/or property damage, it is important that Safe Servicing Practices be observed. The following are some limited examples of safe practices: 1. DO NOT attempt a product repair if you have any doubts as to your ability to complete it in a safe and satisfactory manner. 2. Before servicing or moving an appliance: Remove the power cord from the electrical outlet, trip the circuit breaker to the OFF position, or remove the fuse. Turn off the gas supply. Turn off the water supply. 3. Never interfere with the proper operation of any safety device. 4. USE ONLY REPLACEMENT PARTS CATALOGED FOR THIS APPLIANCE. SUBSTITUTIONS MAY DEFEAT COMPLIANCE WITH SAFETY STANDARDS SET FOR HOME APPLIANCES. 5. GROUNDING: The standard color coding for safety ground wires is GREEN, or GREEN with YELLOW STRIPES. Ground leads are not to be used as current carrying conductors. It is EXTREMELY important that the service technician reestablish all safety grounds prior to completion of service. Failure to do so will create a hazard. 6. Prior to returning the product to service, ensure that: All electrical connections are correct and secure All electrical leads are properly dressed and secured away from sharp edges, high-temperature components, and moving parts All non-insulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal parts and panels All safety grounds (both internal and external) are correctly and securely connected All panels are properly and securely reassembled ATTENTION!!! This service manual is intended for use by persons having electrical and mechnical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. Electrolux Home Products, Inc. cannot be responsible, nor assume any liability, for injury or damage of any kind arising from the use of this manual. 2004 Electrolux Home Products, Inc. 2

Model Service Data Sheet Charge Energy Efficiency Rating Brand CRTE151AQ1 240379011 4.5 443 Crosley CRTE151AW1 240379011 4.5 443 Crosley CRTE171AQ1 240379011 4.5 460 Crosley CRTE171AW1 240379011 4.5 460 Crosley CRTE183AQ0 240379011 4.25 479 Crosley CRTE183AW0 240379011 4.25 479 Crosley CRTE187AK0 240379013 4.25 479 Crosley CRTE187AS0 240379013 4.25 479 Crosley E23CS75DSS1 241532603 5.75 687 Electrolux FRS23BH6CS2 240389616 5 583 Frigidaire FRS23F4CB5 240389616 5 686 Frigidaire FRS23F4CQ4 240389616 5 686 Frigidaire FRS23F4CQ5 240389616 5 686 Frigidaire FRS23F4CW4 240389616 5 686 Frigidaire FRS23F4CW5 240389616 5 686 Frigidaire FRS23FCDB0 240389616 5 686 Frigidaire FRS23FCDQ0 240389616 5 686 Frigidaire FRS23FCDW0 240389616 5 686 Frigidaire FRS23H5DSB0 240389618 5 583 Frigidaire FRS23H7CB2 240389615 5 583 Frigidaire FRS23H7CQ2 240389615 5 583 Frigidaire FRS23H7CW2 240389615 5 583 Frigidaire FRS23KF6CB2 240389615 5 583 Frigidaire FRS23KF6CQ2 240389615 5 583 Frigidaire FRS23LH5DS0 240389616 5 583 Frigidaire FRS23LH5DW0 240389616 5 583 Frigidaire FRS23R4CB4 240389615 5 686 Frigidaire FRS23R4CB5 240389616 5 686 Frigidaire FRS23R4CQ4 240389615 5 686 Frigidaire FRS23R4CQ5 240389616 5 686 Frigidaire FRS23R4CW4 240389615 5 686 Frigidaire FRS23R4CW5 240389616 5 686 Frigidaire FRS23W3AQB 240389615 5 686 Frigidaire FRS23W3AQC 240389616 5 686 Frigidaire FRS23W3AWB 240389615 5 686 Frigidaire FRS23W3AWC 240389616 5 686 Frigidaire FRS26BH6CW4 240389615 5.25 618 Frigidaire FRS26DR7DS0 240389618 5.25 618 Frigidaire FRS26F4CB2 240389616 5.25 727 Frigidaire FRS26F4CB3 240389616 5.25 727 Frigidaire FRS26F4CQ2 240389616 5.25 727 Frigidaire FRS26F4CQ3 240389616 5.25 727 Frigidaire FRS26F4CW2 240389616 5.25 727 Frigidaire FRS26F4CW3 240389616 5.25 727 Frigidaire FRS26FCDB0 240389616 5.25 727 Frigidaire FRS26FCDQ0 240389616 5.25 727 Frigidaire FRS26FCDW0 240389616 5.25 727 Frigidaire FRS26H7CQ4 240389615 5.25 618 Frigidaire FRS26H7CW4 240389615 5.25 618 Frigidaire FRS26HF6BB6 240389615 5.25 618 Frigidaire FRS26HF6BQ6 240389615 5.25 618 Frigidaire FRS26HR4DB0 240389616 5.25 618 Frigidaire FRS26HR4DQ0 240389616 5.25 618 Frigidaire FRS26HR4DW0 240389616 5.25 618 Frigidaire FRS26LF7DS0 240389616 5.25 618 Frigidaire FRS26LF8CB1 240389615 5.25 618 Frigidaire 3

Model Service Data Sheet Charge Energy Efficiency Rating Brand FRS26LF8CQ1 240389615 5.25 618 Frigidaire FRS26LH5DB0 240389616 5.25 618 Frigidaire FRS26LH5DQ0 240389616 5.25 618 Frigidaire FRS26LH5DS0 240389616 5.25 618 Frigidaire FRS26LH5DW0 240389616 5.25 618 Frigidaire FRS26R2AQ7 240389616 5.25 727 Frigidaire FRS26R2AQ8 240389616 5.25 727 Frigidaire FRS26R2AW7 240389616 5.25 727 Frigidaire FRS26R2AW8 240389616 5.25 727 Frigidaire FRS26R4CB2 240389616 5.25 727 Frigidaire FRS26R4CB3 240389616 5.25 727 Frigidaire FRS26R4CQ3 240389616 5.25 727 Frigidaire FRS26R4CW2 240389616 5.25 727 Frigidaire FRS26R4CW3 240389616 5.25 727 Frigidaire FRS26RBCW2 240389616 5.25 727 Frigidaire FRS26RBCW3 240389616 5.25 727 Frigidaire FRS26RLECS1 240389616 5.25 727 Frigidaire FRS26RLECS2 240389616 5.25 727 Frigidaire FRS26W2AQ7 240389613 5.25 727 Frigidaire FRS26W2AW8 240389616 5.25 727 Frigidaire FRS26W2AW9 240389616 5.25 727 Frigidaire FRT14A2AW4 240379015 4.5 440 Frigidaire FRT14A2AZ4 240379015 4.5 440 Frigidaire FRT15A2DW0 240379015 4.5 443 Frigidaire FRT15A2DZ0 240379015 4.5 443 Frigidaire FRT15B1BW2 240379015 4.5 443 Frigidaire FRT15B3AQ5 240379015 4.5 443 Frigidaire FRT15B3AT5 240379015 4.5 443 Frigidaire FRT15B3AW5 240379015 4.5 443 Frigidaire FRT15B3AZ5 240379015 4.5 443 Frigidaire FRT15G4BQ3 240379015 4.5 443 Frigidaire FRT15G4BW3 240379015 4.5 443 Frigidaire FRT15HB3DQ0 240379015 4.25 376 Frigidaire FRT15HB3DW0 240379015 4.25 376 Frigidaire FRT15HB3DZ0 240379015 4.25 376 Frigidaire FRT17A2AQ4 240379011 4.5 460 Frigidaire FRT17A2AW4 240379011 4.5 460 Frigidaire FRT17A2AZ4 240379011 4.5 460 Frigidaire FRT17B3AQ5 240379011 4.5 460 Frigidaire FRT17B3AT5 240379011 4.5 460 Frigidaire FRT17B3AW5 240379011 4.5 460 Frigidaire FRT17B3AZ5 240379011 4.5 460 Frigidaire FRT17G4BD3 240379011 4.5 460 Frigidaire FRT17G4BQ3 240379011 4.5 460 Frigidaire FRT17G4BW3 240379011 4.5 460 Frigidaire FRT18B1BW4 240379015 4.5 479 Frigidaire FRT18B4AQA 240379015 4.5 479 Frigidaire FRT18B4AWA 240379015 4.5 479 Frigidaire FRT18B4AZA 240379015 4.5 479 Frigidaire FRT18B5ABB 240379014 4.25 479 Frigidaire FRT18B5AQB 240379014 4.25 479 Frigidaire FRT18B5AWB 240379014 4.25 479 Frigidaire FRT18B6CB7 240379014 4.25 479 Frigidaire FRT18G4AQC 240379011 4.5 479 Frigidaire FRT18G4AWC 240379011 4.5 479 Frigidaire FRT18G7CW4 240379015 4.5 479 Frigidaire 4

Model Service Data Sheet Charge Energy Efficiency Rating Brand FRT18H6CB5 240379014 4.25 407 Frigidaire FRT18H6CQ5 240379014 4.25 407 Frigidaire FRT18H6CSB4 240379015 4.25 407 Frigidaire FRT18H6CSK4 240379015 4.25 407 Frigidaire FRT18H6CW5 240379014 4.25 407 Frigidaire FRT18HB5DW0 240379015 4.25 407 Frigidaire FRT18HS6AB5 240379014 4.25 407 Frigidaire FRT18HS6DB1 240379014 4.25 407 Frigidaire FRT18HS6DQ0 240379015 4.25 407 Frigidaire FRT18HS6DW0 240379015 4.25 407 Frigidaire FRT18IB4AQA 240379015 4.5 479 Frigidaire FRT18IB4AWA 240379015 4.5 479 Frigidaire FRT18IB4AZ8 240379011 4.5 479 Frigidaire FRT18IB4AZA 240379015 4.5 479 Frigidaire FRT18IG4AQA 240379015 4.5 479 Frigidaire FRT18IG4ATA 240379015 4.5 479 Frigidaire FRT18IG4AWA 240379015 4.5 479 Frigidaire FRT18IG4AZA 240379015 4.5 479 Frigidaire FRT18IL6DQ0 240379015 4.25 479 Frigidaire FRT18IL6DS0 240379015 4.25 479 Frigidaire FRT18IL6DW0 240379015 4.25 479 Frigidaire FRT18IS6CB1 240379007 4.25 479 Frigidaire FRT18KB2CW4 240379015 4.5 479 Frigidaire FRT18KG3CW4 240379015 4.5 479 Frigidaire FRT18KG4CW4 240379015 4.5 479 Frigidaire FRT18LN5BQ6 240379015 4.5 479 Frigidaire FRT18LN5BW6 240379015 4.5 479 Frigidaire FRT21BH8CB2 240379014 4.25 432 Frigidaire FRT21BH8CS2 240379014 4.25 432 Frigidaire FRT21BH8CW2 240379014 4.25 432 Frigidaire FRT21BSDSB0 241588200 4.5 432 Frigidaire FRT21C5AQ9 240379014 4.5 509 Frigidaire FRT21C5AW9 240379014 4.5 509 Frigidaire FRT21FG3CQ3 240379014 4.25 509 Frigidaire FRT21FG3CW3 240379014 4.25 509 Frigidaire FRT21FG4CQ3 240379014 4.25 509 Frigidaire FRT21FG4CW3 240379014 4.25 509 Frigidaire FRT21G3CW2 240379012 4.25 509 Frigidaire FRT21G3CW3 240379014 4.25 509 Frigidaire FRT21G4BQ7 240379014 4.25 509 Frigidaire FRT21G4BW7 240379014 4.25 509 Frigidaire FRT21H7ASB5 240379014 4.25 432 Frigidaire FRT21H7ASK4 240379014 4.25 432 Frigidaire FRT21H8CB2 240379014 4.25 432 Frigidaire FRT21H8CQ2 240379014 4.25 432 Frigidaire FRT21H8CSB2 240379014 4.5 432 Frigidaire FRT21H8CSK2 240379014 4.5 432 Frigidaire FRT21H8CW2 240379014 4.25 432 Frigidaire FRT21HS6AW6 240379014 4.25 432 Frigidaire FRT21HS6DB0 240379014 4.5 432 Frigidaire FRT21HS6DQ0 240379014 4.5 432 Frigidaire FRT21HS6DW0 240379014 4.5 432 Frigidaire FRT21IL5DQ0 240379014 4.25 509 Frigidaire FRT21IL5DW0 240379014 4.25 509 Frigidaire FRT21KG3CW3 240379014 4.25 509 Frigidaire FRT21KG4CW3 240379014 4.25 509 Frigidaire 5

Model Service Data Sheet Charge Energy Efficiency Rating Brand FRT21KS6CQ3 240379014 4.5 509 Frigidaire FRT21LR7AB9 240379014 4.25 432 Frigidaire FRT21LR7AQ9 240379014 4.25 432 Frigidaire FRT21LR7AW9 240379014 4.25 432 Frigidaire FRT21LR8DS0 240379014 4.25 458 Frigidaire FRT21P5ABA 240379014 4.25 509 Frigidaire FRT21P5AQA 240379014 4.25 509 Frigidaire FRT21P5AWA 240379014 4.25 509 Frigidaire FRT21P6CQ3 240379014 4.25 509 Frigidaire FRT21P6CSB3 240379014 4.25 509 Frigidaire FRT21P6CSK3 240379014 4.25 509 Frigidaire FRT21P6CW3 240379014 4.25 509 Frigidaire FRT21S6AB8 240379014 4.25 509 Frigidaire FRT21S6AW8 240379014 4.25 509 Frigidaire GLHS237ZCW2 240389016 5 583 Frigidaire GLHS269ZCB4 240389015 5.25 618 Frigidaire GLRS237ZCB4 240389015 5 686 Frigidaire GLRS237ZCB5 240389016 5 686 Frigidaire GLRS237ZCQ4 240389015 5 686 Frigidaire GLRS237ZCQ5 240389016 5 686 Frigidaire GLRS237ZCW4 240389015 5 686 Frigidaire GLRS237ZCW5 240389016 5 686 Frigidaire GLRS267ZCB2 240389616 5.25 727 Frigidaire GLRS267ZCB3 240389616 5.25 727 Frigidaire GLRS267ZCQ2 240389616 5.25 727 Frigidaire GLRS267ZCQ3 240389616 5.25 727 Frigidaire GLRS267ZCW2 240389616 5.25 727 Frigidaire GLRS267ZCW3 240389616 5.25 727 Frigidaire GLRT183TDB1 240379013 4.25 479 Frigidaire GLRT183TDB3 240379014 4.25 479 Frigidaire GLRT183TDQ0 240379015 4.25 479 Frigidaire GLRT183TDW0 240379015 4.25 479 Frigidaire GLRT184TCB7 240379014 4.25 479 Frigidaire GLRT185TDB1 240379012 4.25 479 Frigidaire GLRT185TDB3 240379014 4.25 479 Frigidaire GLRT185TDK0 240379015 4.25 479 Frigidaire GLRT185TDQ0 240379015 4.25 479 Frigidaire GLRT185TDS0 240379015 4.25 479 Frigidaire GLRT185TDW0 240379015 4.25 479 Frigidaire GLRT212IDB0 240379012 4.25 509 Frigidaire GLRT212IDB1 240379014 4.25 509 Frigidaire GLRT212IDQ0 240379012 4.25 509 Frigidaire GLRT212IDQ1 240379014 4.25 509 Frigidaire GLRT212IDW0 240379012 4.25 509 Frigidaire GLRT212IDW1 240379014 4.25 509 Frigidaire GLRT214TCB3 240379014 4.25 509 Frigidaire GLRT214TCQ3 240379014 4.25 509 Frigidaire GLRT214TCW3 240379014 4.25 509 Frigidaire GRS23R4CQ3 240389613 5 686 Frigidaire GS18HTZCQ2 240379011 4.25 431 Frigidaire GS18HTZCW2 240379011 4.25 431 Frigidaire GS18HTZDB1 240379014 4.25 407 Frigidaire GS18HTZDSB0 240379015 4.25 407 Frigidaire GS18HTZDSK0 240379015 4.25 407 Frigidaire GS18HTZDW0 240379015 4.25 407 Frigidaire GS23HSZCC3 240389615 5 583 Frigidaire 6

Model Service Data Sheet Charge Energy Efficiency Rating Brand GS23HSZCQ2 240389615 5 583 Frigidaire GS26HSZCC5 240389616 5 583 Frigidaire GS26HSZCQ4 240389616 5 583 Frigidaire PLHT189CSB4 240379015 4.25 407 Frigidaire PLHT189CSK4 240379015 4.25 407 Frigidaire PLHT219TCB4 240379014 4.25 432 Frigidaire PLHT219TCK4 240379014 4.25 432 Frigidaire FSC23F7DB0 241532603 5.75 687 Frigidaire-CD PHSC239DSB0 241532603 6 584 Frigidaire-CD GRT15B3BW3 240379011 4.5 443 Gibson GRT17B3BQ3 240379011 4.5 460 Gibson GRT17B3BW3 240379011 4.5 460 Gibson GRT17G4BQ3 240379011 4.5 460 Gibson GRT17G4BW3 240379011 4.5 460 Gibson GRT21G3CW3 240379014 4.5 509 Gibson GRT21S6CW3 240379014 4.5 509 Gibson WRS23MF5ASA 240389616 5 686 W / W WRS23MW3AQA 240389616 5 686 W / W WRS23MW3AW9 240389615 5 686 W / W WRS23MW3AWA 240389616 5 686 W / W WRS23W0AWA 240389615 5 686 W / W WRS23W0AWB 240389616 5 686 W / W WRT15A0AW4 240379015 4.5 443 W / W WRT15MB3AW4 240379015 4.25 443 W / W WRT15MG4BQ1 240379011 4.25 443 W / W WRT17MB3AW4 240379015 4.25 460 W / W WRT17MG4BQ1 240379011 4.25 460 W / W WRT18A0AWA 240379015 4.5 479 W / W WRT21MG3AQ6 240379014 4.25 509 W / W WRT21MG3AW6 240379014 4.25 509 W / W WRT21MP5AQ7 240379014 4.25 509 W / W WRT21MP5AW7 240379014 4.25 509 W / W WRT21MR7AS6 240379014 4.25 509 W / W WRT21S4AW6 240379014 4.25 509 W / W 7

TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION Compressor will not run. Compressor runs but does not cool. No voltage at wall receptacle. Service cord defective or unplugged at wall receptacle. Low voltage causing compressor to cycle on overload. Control thermostat knob in OFF position. Inoperative control thermostat. Compressor stuck. Compressor windings open. Defrost timer stuck in defrost mode. ADC (Adaptive Defrost Control) not turning on compressor after defrost. Compressor overload stuck open. Relay lead loose. Relay loose or inoperative. Service cord pulled out of harness. Faulty cabinet wiring. Check circuit breaker, fuse or GFCI (Ground Fault Circuit Interruptor - It is not recommended to connect your refrigerator to a GFCI.) Check service cord. Voltage fluctuation should not exceed ± 10% of vac (104-127) Turn control thermostat knob to ON position. Replace control thermostat Replace compressor. Replace compressor. Replace defrost timer. (if equipped) Replace ADC. Replace compressor overload. (if equipped compressor starter relay & overload may be plugged into each other) Repair or replace lead. Repair or replace relay. (if equipped) Repair connection. Repair wiring. System out of refrigerant. Check for leaks. * Compressor not pumping. Replace compressor. * Restricted filter drier. Replace filter drier. * Restricted capillary tube. Replace heat exchanger and evaporator assembly. Moisture in system. See NOTE. * * NOTE: Repair or replace component that is leaking. Replace the compressor if the system is contaminated. Blow out remaining part of system with dry Nitrogen. Pump down and recharge per listing on product serial label. Always replace filter drier when repairing sealed system. 8

PROBLEM CAUSE SOLUTION Compressor short cycles. Compressor runs too much. Noisy. Erratic control thermostat. Faulty relay. Restricted air flow over condenser. Low voltage fluctuation exceeds ± 10% of vac (104-127). Compressor draws excessive watts. Inoperative condenser fan motor. Control thermostat is erratic or not properly set. Refrigerator exposed to high heat. (110 or higher) High room temperature. (110 F or higher) Low pumping capacity compressor. Door gaskets not sealing. Replace control thermostat. Replace relay or starter. Ensure air flow is unobstructed over condenser. Call qualified electrician. Replace compressor. Replace condenser fan motor. Replace control thermostat or reset to normal position. Move refrigerator to cooler location. Advise customer not to install refrigerator where temperature will rise above 110 F because compressor will not maintain proper temperatures. Replace compressor. System undercharged. Check for leaks. * System overcharged. Adjust doors or replace door gaskets. Charge per listing on product serial plate. * Interior light stays on. Check door switch and door adjustment. Contaminants in system. Capillary tube kinked or partially restricted. Flush out system. Replace filter drier, evacuate, and recharge. * Replace heat exchanger and evaporator assembly. * Filter drier partially restricted. Replace filter drier. * Refrigerator and/or freezer compartment overloaded poor air circulation Restricted air flow over condenser. Condenser fan motor is inoperative. (Forced air condenser models only) Tubing vibrates. Internal compressor noise. Loose parts. Compressor operating at high head pressure due to restricted air flow over condenser. Advise customer. Ensure air flow is unobstructed over condenser. Replace condenser fan motor. Adjust tubing. Replace compressor. Check shelving. Ensure air flow is unobstructed over condenser. * See NOTE at bottom of page 8) 9

PROBLEM CAUSE SOLUTION Freezer compartment too warm. Fig. A Freezer compartment too cold. Inoperative evaporator fan motor. Improperly positioned fan blade. Check wiring and evaporator fan motor. (Check ADC on Side-by-Sides.) Position fan blade properly. See Figure A. Evaporated frosted up. Check defrost system, door adjustments, and door gaskets. Inoperative condenser fan motor. (Forced air condenser models only) Restricted air flow over condenser On static condensers, be sure you have 1 between condenser and wall, and 3 over top, or 1 side of condenser is clear. Freezer compartment overloaded poor air circulation. Replace condenser fan motor. Clean condenser. (Dynamic models only.) Advise customer. Low room temperature.(55 ) Advise customer not to install refrigerator where temperature will drop below 60 F. Compressor will not maintain proper temperatures. Freezer or refrigerator compartment doors left open. Control thermostat out of calibration. Door gaskets not sealing. Control thermostat capillary tube improperly positioned. Advise customer. Replace control thermostat. Shortage of refrigerant. Check for leaks. * Restricted filter drier or capillary tube. Evaporator fan motor covered in ice. Inoperative cold control. (Top mount-no Frost or Side-by-Side freezer cold control) Freezer compartment inlet air duct is loose or restricted. Door is loose. Food compartment air return duct blocked (Top Mount only) Diffuser (foam block) in top of food compartment is broken. (Foam block located in control housing.) 5 Adjust doors or replace door gaskets. Reposition temperature sensing element. Check for leaks and burnt compressor windings. * Check seal around ice maker fill spout. Check seal between evaporator cover and liner. (Side-by-sides only) Replace cold control. Re-install air duct or remove obstruction from inlet air duct. Adjust door. If foam block is frozen, replace block. If duct is blocked, remove obstruction. Replace diffuser. (Top Mount only) Freezer compartment cold control installed incorrectly. (Side-by-Sides only) * See NOTE at bottom of page 8 10

PROBLEM CAUSE SOLUTION Refrigerator compartment too warm. Refrigerator compartment too cold. Inoperative evaporator fan motor. Improperly positioned fan blade. Check wiring and evaporator fan motor. (Check ADC on Side-by-Sides.) Position fan blade properly. See page 10, Figure A. Evaporated frosted up. Check defrost system, door adjustments, and door gaskets. Refrigerator compartment overloaded poor air circulation. Advise customer. Low room temperature. (55 ) Advise customer not to install refrigerator where temperature will drop below 60 F. Compressor will not maintain proper temperatures. Freezer or refrigerator compartment doors left open. Damper control out of calibration or not opening. Advise customer. Replace damper control. Shortage of refrigerant. Check for leaks. * Restricted filter drier or capillary tube. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Freezer compartment return air duct restricted. Control thermostat knob set at too warm a position. Inoperative or erratic refrigerator/freezer compartment door switch. Freezer compartment inlet air duct is loose or restricted. Door is loose. Food compartment air return duct blocked (Top Mount only) Inoperative cold control. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Diffuser (foam block) in top of food compartment is broken. (Foam blocked located in control housing.) Check for leaks and burnt compressor windings. * Re-install air duct or remove obstruction from air duct. Adjust door. Remove obstruction from return air duct. Set control knob to a colder position. Replace door switch. Re-install air duct or remove obstruction from inlet air duct. Adjust door. If foam block is frozen, replace block. If duct is blocked, remove obstruction. Replace cold control. Re-install air duct or remove obstruction from air duct. Adjust door. Replace diffuser. (Top Mounts only) * See NOTE at bottom of page 8. 11

PROBLEM CAUSE SOLUTION Refrigerator compartment too cold. (Continued) Evaporator blocked with ice. (See Adaptive defrost Control) Frozen drain. Adaptive Defrost Control (ADC) not responding correctly. Inoperative cold control. Refrigerator compartment inlet air duct loose or restricted. Door is loose. Diffuser (foam block) in top of food compartment is broken. (Foam blocked located in control housing) Door in damper control not closing or not closing all the way. Cold air blowing into food compartment with damper door closed all the way. Inoperative defrost timer. Defrost thermostat terminates too early. Thermostat is open. Refrigerator/Freezer compartment doors left open. Open defrost heater. Air leak around ice maker fill tube, or opening. Ice maker water line and wiring harness openings not sealed. Drain trough not properly formed. Divider (foam block) frozen. Faulty ADC board. Bad wire between ADC, defrost heater, and limiter. Replace cold control. Re-install air duct or remove obstruction from air duct. Adjust door. Replace diffuser. (Top Mounts only) Replace damper control. Check freezer control bulb for correct positioning to ensure it is installed correctly. Check foam seal between damper housing and cabinet liner. Check to see that the control box is mounted flush against the cabinet liner. Check wiring. Repair or replace defrost timer. Check for correct positioning of defrost thermostat. Repair or replace. Advise customer. Replace heater. Seal with permagum. Seal water line and wiring harness openings. Ensure drain trough is at 90 angle to back of freezer and that lip is up on front and ends. Replace divider. Check drain trough. Replace ADC board. Check wiring and wiring connectors. 12

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING SERVICE DATA SHEET INFORMATION Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) IMPORTANT SAFETY NOTICE P/N: 240379007 Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until Holding Switch circuit is completed. All components of ice maker should function to complete the cycle. L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 Base Voltage Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C VAC VAC Thermostat Cut-out 47 F 8 C Ohms 375 35 The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the fill volume must be checked. A - 1 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 2.3 1100 CW Opposite Shaft.15 Running SPECIFICATIONS Electrical Volts 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 CONNECTOR PLUG CONNECTIONS Wire Number W ire Color Connects to: 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue Ground Water Valve Line Neutral

Pictorial Schematic Ladder Schematic A - 2 Compressor Wiring

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: 240379011 IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 375 35 CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 3 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM 2.3 1100 CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO YEL THERMOSTAT C RED NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE

Pictorial Schematic Ladder Schematic NOTE: DENOTES NOT ON ALL MODELS A - 4 COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * 5303918264 5303918264 5303918295 240435705 240435705 5303918295 5303918264 5303918295 Starter/PTC * 218721120 218721120 218721120 218721120 218721120 218721120 218721120 218721120 Run Capacitor * 218909913 218909913 218909912 218909913 218909913 218909912 218909913 218909912 Relay N/A N/A N/A 5304433579 5304433579 N/A N/A N/A Overload N/A N/A N/A 5304433578 5304433578 N/A N/A N/A Control 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 Timer (if applicable) 215846606 215846606 215846606 215846606 215846606 215846606 215846606 215846606 ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit 5303918203 5303918203 5303918203 5303918208 5303918208 5303918208 5303918247 5303918247 Defrost Thermostat Kit 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 Evaporator Fan Motor 240369701 240369701 240369701 240369701 240369701 240369701 240369701 240369701 Condenser Fan Motor N/A 240523601 240523601 N/A 240523601 240523601 240334001 240334001

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: 240379012 IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 375 35 CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 5 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM 2.3 1100 CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO YEL THERMOSTAT C RED NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE

Pictorial Schematic Ladder Schematic A - 6 NOTE: DENOTES NOT ON ALL MODELS COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * 5303918264 5303918264 5303918295 5303918297 5303918297 5303918251 5303918297 5303918251 Starter/PTC * 218721120 218721120 218721120 N/A N/A 218721119 N/A 218721119 Run Capacitor * 218909913 218909913 218909912 N/A N/A 218909913 N/A 218909913 Relay N/A N/A N/A 5304433579 5304433579 N/A 5304433579 N/A Overload N/A N/A N/A 5304433578 5304433578 N/A 5304433578 N/A Control 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 Timer (if applicable) 215846606 215846606 215846606 215846606 215846606 215846606 215846606 215846606 ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit 5303918203 5303918203 5303918203 5303918208 5303918208 5303918208 5303918247 5303918247 Defrost Thermostat Kit 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 Evaporator Fan Motor 240369701 240369701 240369701 240369701 240369701 240369701 240369701 240369701 Condenser Fan Motor N/A 240523601 240523601 N/A 240523601 240523601 240334001 240334001 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET P/N: 240379013 IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 375 35 CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 7 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM 2.3 1100 CW Opposite Shaft.15 Running SPECIFICATIONS NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral LINE GRN / YEL P-3 P-1 THERMAL CUT-OUT GRN / YEL MOLD BRN MOUNTING PLATE MOTOR RED POWER MOLD HEATER 165 WATTS HOLD SWITCH C NC NO YEL THERMOSTAT C RED NO NC WATER FILL SWITCH BLU C NO NC SHUT-OFF SWITCH LT. BLU YEL RED NEUTRAL YEL P-4 P-2 WATER VALVE

Pictorial Schematic Ladder Schematic A - 8 NOTE: COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * 5303918264 5303918264 5303918299 5303918297 5303918297 5303918299 5303918297 5303918299 Starter/PTC/TSD * 218721120 218721120 241527802 N/A N/A 241527802 N/A 241527802 Run Capacitor * 218909913 218909913 218909915 N/A N/A 218909915 N/A 218909915 Relay N/A N/A N/A 5304433579 5304433579 N/A 5304433579 N/A Overload N/A N/A N/A 5304433578 5304433578 N/A 5304433578 N/A Control 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 Timer (if applicable) 215846606 215846606 215846606 215846606 215846606 215846606 215846606 215846606 ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit 5303918203 5303918203 5303918203 5303918208 5303918208 5303918208 5303918247 5303918247 Defrost Thermostat Kit 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 Evaporator Fan Motor 240369701 240369701 240369701 240369701 240369701 240369701 240369701 240369701 Condenser Fan Motor N/A 240523601 240523601 N/A 240523601 240523601 240334001 240334001 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING SERVICE DATA SHEET INFORMATION Capacitor Run or Induction Run 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) IMPORTANT SAFETY NOTICE P/N: 240379014 Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until Holding Switch circuit is completed. All components of ice maker should function to complete the cycle. L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 375 35 The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the fill volume must be checked. A - 9 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM NOTE: Some products come equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 2.3 1100 CW Opposite Shaft.15 Running LINE POWER NEUTRAL Wire CONNECTOR PLUG CONNECTIONS Number SPECIFICATIONS E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral GRN / YEL P-3 P-1 THER MAL CUT-OUT GRN / YEL MOLD BRN MOUN TING PLATE MOTOR RED MOLD HEATER HOLD SW ITCH YEL T HERMOSTAT WATER FILL SWITCH BLU SHUT-OF F SWITCH LT. B LU YEL RED YEL P-4 LT. BLU P-2 WATER VALVE

Pictorial Schematic Ladder Schematic A - 10 NOTE: DENOTES NOT ON ALL MODELS COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * 5303918264 5303918264 5303918299 5303918297 5303918297 5303918299 5303918297 5303918299 Starter/PTC/TSD * 218721120 218721120 241527802 N/A N/A 241527802 N/A 241527802 Run Capacitor * 218909913 218909913 218909915 N/A N/A 218909915 N/A 218909915 Relay N/A N/A N/A 5304433579 5304433579 N/A 5304433579 N/A Overload N/A N/A N/A 5304433578 5304433578 N/A 5304433578 N/A Control 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 Timer (if applicable) 215846606 215846606 215846606 215846606 215846606 215846606 215846606 215846606 ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit 5303918203 5303918203 5303918203 5303918208 5303918208 5303918208 5303918247 5303918247 Defrost Thermostat Kit 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 Evaporator Fan Motor 240369701 240369701 240369701 240369701 240369701 241537301 240369701 240369701 Condenser Fan Motor N/A 240523601 240523601 N/A 240523601 240523601 240523601 241538001 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING SERVICE DATA SHEET INFORMATION Capacitor Run or Induction Run 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) IMPORTANT SAFETY NOTICE P/N: 240379015 Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until Holding Switch circuit is completed. All components of ice maker should function to complete the cycle. L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 375 35 The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the fill volume must be checked. A - 11 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM NOTE: Some products come equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 2.3 1100 CW Opposite Shaft.15 Running LINE POWER NEUTRAL Wire CONNECTOR PLUG CONNECTIONS Number SPECIFICATIONS E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral GRN / YEL P-3 P-1 THER MAL CUT-OUT GRN / YEL MOLD BRN MOUN TING PLATE MOTOR RED MOLD HEATER HOLD SW ITCH YEL T HERMOSTAT WATER FILL SWITCH BLU SHUT-OF F SWITCH LT. B LU YEL RED YEL P-4 LT. BLU P-2 WATER VALVE

Pictorial Schematic Ladder Schematic A - 12 NOTE: DENOTES NOT ON ALL MODELS COMPRESSOR WIRING Induction Run Compressor with Relay 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * 240550915 240550915 5303918299 240550915 240550915 5303918299 240550915 5303918299 Starter/PTC/TSD * N/A N/A 241527802 N/A N/A 241527802 N/A 241527802 Run Capacitor * N/A N/A 218909915 N/A N/A 218909915 N/A 218909915 Relay 5304433579 5304433579 N/A 5304433579 5304433579 N/A 5304433579 N/A Overload 5304433578 5304433578 N/A 5304433578 5304433578 N/A 5304433578 N/A Control 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 Timer (if applicable) 215846606 215846606 215846606 215846606 215846606 215846606 215846606 215846606 ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit 5303918203 5303918203 5303918203 5303918208 5303918208 5303918208 5303918247 5303918247 Defrost Thermostat Kit 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 Evaporator Fan Motor 240369701 240369701 240369701 240369701 240369701 240369701 240369701 240369701 Condenser Fan Motor N/A 240523601 240523601 N/A 240523601 240523601 240334001 240334001 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Capacitor Run or Induction Run 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 25 to 35% 45 to 55% Freezer Refrigerature 2 to 8 F -17 to -13 C 35 to 40 F 2 to 4 C 0 to 5 F -18 to -15 C 35 to 40 F 2 to 4 C STANDARD - AUTOMATIC DEFROST TOP FREEZER MODELS (R134a) SERVICE DATA SHEET IMPORTANT SAFETY NOTICE P/N: 241588200 INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until Holding Switch circuit is completed. All components of ice maker should function to complete the cycle. L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 110 to 120 psig 758 to 827 kpa 8 to 16 psig 55 to 110 kpa 1 to 4 psig 7 to 28 kpa 150 to 175 psig 1034 to 1207 kpa (Last 1/3 of cycle) 140 to 185 140 to 185 (Running) 1.1 to 1. 6 1.1 to 1. 6 B ase Voltage VAC (127 VAC Max) VAC (127 VAC Max) Cabinet Size 18' & 21' DEFROST SPECIFICATIONS Cut-in 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 375 35 The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the fill volume must be checked. A - 13 14', 15' & 17' 25 F -4 C 47 F 8 C 325 41 Mechanical Timer - Defrost 30 Minutes Every 10 Hours of Compressor Run Time Electronic Timer (ADC) Defrost Up To 24 Minutes Every 6-72 Hours of Compressor Run Time CONDENSER FAN MOTOR RPM NOTE: Some products come equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 2.3 1100 CW Opposite Shaft.15 Running LINE POWER NEUTRAL Wire CONNECTOR PLUG CONNECTIONS Number SPECIFICATIONS E lectrical VAC (127 VAC Max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral GRN / YEL P-3 P-1 THER MAL CUT-OUT GRN / YEL MOLD BRN MOUN TING PLATE MOTOR RED MOLD HEATER HOLD SW ITCH YEL T HERMOSTAT WATER FILL SWITCH BLU SHUT-OF F SWITCH LT. B LU YEL RED YEL P-4 LT. BLU P-2 WATER VALVE

A - 14 15 & 17 CUBIC FOOT 18 CUBIC FOOT 21 CUBIC FOOT SERVICE PARTS STATIC DYNAMIC E-STAR STATIC DYNAMIC E-STAR DYNAMIC E-STAR Compressor / Kit * 240550915 240550915 5303918299 240550915 240550915 5303918299 240550915 5303918299 Starter/PTC/TSD * N/A N/A 241527802 N/A N/A 241527802 N/A 241527802 Run Capacitor * N/A N/A 218909915 N/A N/A 218909915 N/A 218909915 Relay 5304433579 5304433579 N/A 5304433579 5304433579 N/A 5304433579 N/A Overload 5304433578 5304433578 N/A 5304433578 5304433578 N/A 5304433578 N/A Control 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 5304421256 Timer (if applicable) 215846606 215846606 215846606 215846606 215846606 215846606 215846606 215846606 ADC (if applicable) N/A N/A N/A N/A N/A N/A N/A N/A Defrost Kit 5303918203 5303918203 5303918203 5303918208 5303918208 5303918208 5303918247 5303918247 Defrost Thermostat Kit 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 5303918202 Evaporator Fan Motor 240369701 240369701 240369701 240369701 240369701 240369701 240369701 240369701 Condenser Fan Motor N/A 240523601 240523601 N/A 240523601 240523601 240334001 240334001 Induction Run Compressor with Relay COMPRESSOR WIRING * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 32 to 40% 55 to 65% Freezer Refrigerator L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 130 to 155 psig 896 to 1069 kpa (Last 1/3 of cycle) 120 to 150 130 to 160 (Running) 1.2 to 1. 5 1.2 to 1. 5 B ase Voltage vac (127 vac max) vac (127 vac max) SERVICE DATA SHEET - 240389613 R134a ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE MODELS IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Cabinet Size DEFROST SPECIFICATIONS Cut-in 23' & 26' 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 450 30 Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 15 CONDENSER FAN MOTOR RPM 7 1100 CW Opposite Shaft.1 Running SPECIFICATIONS E lectrical vac (127 vac max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 165 P-3 Wire CONNECTOR PLUG CONNECTIONS Number W ire Color Connects to: P-4 1 Green/Yellow 2 Yellow 3 Black Ground Water Valve Line GREEN/YELLOW GREEN/YELLOW P-1 P-2 4 Lt. Blue Neutral

A - 16 23 CUBIC FOOT 26 CUBIC FOOT SERVICE PARTS STANDARD E-STAR STANDARD E-STAR Compressor Kit * 5303918251 5303918251 5303918254 5303918254 Starter/PTC * 218721119 218721119 218721119 218721119 Run Capacitor * 216787800 216787800 218909901 218909901 Temp. Control-Refr 241507701 241507701 241507701 241507701 Temp. Control-Frzr 450226-07 450226-07 450226-07 450226-07 Timer (if applicable) N/A N/A N/A N/A ADC (if applicable) 241508001 241508001 241508001 241508001 Defrost Kit 5303918253 5303918253 5303918253 5303918253 Defrost Thermostat Kit 5303918214 5303918214 5303918214 5303918214 Evaporator Fan Motor 240315803 240315802 240315803 240315802 Condenser Fan Motor 240397101 240334001 240397101 240334002 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 32 to 40% 55 to 65% Freezer Refrigerator L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 130 to 155 psig 896 to 1069 kpa (Last 1/3 of cycle) 120 to 150 130 to 160 (Running) 1.2 to 1. 5 1.2 to 1. 5 B ase Voltage vac (127 vac max) vac (127 vac max) SERVICE DATA SHEET - 240389615 R134a ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE MODELS IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Cabinet Size DEFROST SPECIFICATIONS Cut-in 23' & 26' 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 450 30 Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. A - 17 CONDENSER FAN MOTOR RPM 7 1100 CW Opposite Shaft.1 Running SPECIFICATIONS E lectrical vac (127 vac max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 165 P-3 Wire CONNECTOR PLUG CONNECTIONS Number W ire Color Connects to: P-4 1 Green/Yellow 2 Yellow 3 Black Ground Water Valve Line GREEN/YELLOW GREEN/YELLOW P-1 P-2 4 Lt. Blue Neutral

A - 18 23 CUBIC FOOT 26 CUBIC FOOT SERVICE PARTS STANDARD E-STAR STANDARD E-STAR Compressor Kit * 5303918251 5303918299 5303918254 5303918298 Starter/PTC/TSD * 218721119 241527802 218721119 241527801 Run Capacitor * 218909912 218909915 218909912 218909915 Temp. Control-Refr 241507701 241507701 241507701 241507701 Temp. Control-Frzr 450226-07 450226-07 450226-07 450226-07 Timer (if applicable) N/A N/A N/A N/A ADC (if applicable) 241508001 241508001 241508001 241508001 Defrost Kit 5303918253 5303918253 5303918253 5303918253 Defrost Thermostat Kit 5303918214 5303918214 5303918214 5303918214 Evaporator Fan Motor 240369701 240369701 240369701 241537301 Condenser Fan Motor 240397101 241538001 240397101 241538001 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 32 to 40% 55 to 65% Freezer Refrigerator L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 130 to 155 psig 896 to 1069 kpa (Last 1/3 of cycle) 120 to 150 130 to 160 (Running) 1.2 to 1. 5 1.2 to 1. 5 B ase Voltage vac (127 vac max) vac (127 vac max) Cabinet Size DEFROST SPECIFICATIONS Cut-in 23' & 26' 25 F -4 C Thermostat Cut-out 47 F 8 C Ohms 450 30 Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time. SERVICE DATA SHEET - 240389616 R134a ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE MODELS IMPORTANT SAFETY NOTICE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. IMPORTANT If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. CAUTION: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. NOTE: This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds. INFORMATION Test Cycling Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. A - 19 CONDENSER FAN MOTOR RPM 7 1100 CW Opposite Shaft.1 Running SPECIFICATIONS P-3 E lectrical vac (127 vac max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 P-4 CONNECTOR PLUG CONNECTIONS Wire Number 1 Green/Yellow 2 Yellow W ire Color Connects to: Ground Water Valve GREEN/YELLOW GREEN/YELLOW P-1 P-2 3 Black 4 Lt. Blue Line Neutral

A - 20 23 CUBIC FOOT 26 CUBIC FOOT SERVICE PARTS STANDARD E-STAR STANDARD E-STAR Compressor Kit * 5303918303 5303918299 5303918303 5303918298 Starter/PTC/TSD * 241524604 241527802 241524604 241527801 Run Capacitor * 218909913 218909915 218909913 218909915 Temp. Control-Refr 241507701 241507701 241507701 241507701 Temp. Control-Frzr 450226-07 450226-07 450226-07 450226-07 Timer (if applicable) N/A N/A N/A N/A ADC (if applicable) 241508001 241508001 241508001 241508001 Defrost Kit 5303918253 5303918253 5303918253 5303918253 Defrost Thermostat Kit 5303918214 5303918214 5303918214 5303918214 Evaporator Fan Motor 240369701 240369701 240369701 241537301 Condenser Fan Motor 240523601 241538001 240523601 241538001 * Typical compressor kit includes compressor, electrical components, and filter-drier

PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65 F (18 C) Ambient 90 F (32 C) Ambient O perating Time 32 to 40% 55 to 65% Freezer Refrigerator L ow Side Pressure ( cut-in) L ow Side Pressure ( cut-out) H igh Side Pressure ( Last 1/3 of cycle) 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 34 to 83 kpa -2 to 2 psig -14 to 14 kpa 130 to 155 psig 896 to 1069 kpa (Last 1/3 of cycle) 120 to 150 130 to 160 (Running) 1.2 to 1. 5 1.2 to 1. 5 B ase Voltage vac (127 vac max) vac (127 vac max) Cabinet Size DEFROST SPECIFICATIONS Cut-in Thermostat Cut-out Ohms SERVICE DATA SHEET - 240389618 R134a ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE MODELS IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. INFORMATION Test Cycling Press the momemtary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle. Water Fill Volume Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. The water fill adjustment screw will change the fill time. One turn is equal to 20cc (.68 oz.). The correct fill is 102 to 110cc (3.25 to 3.5 oz.). When a water valve is replaced, the fill volume must be checked Motor Gear Water Fill Adjustment TURN Mounting Plate Screws Ice Maker ON/OFF Switch A - 21 23' & 26' 25 F -4 C 47 F 8 C 450 30 Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time. CONDENSER FAN MOTOR RPM 7 1100 CW Opposite Shaft.1 Running SPECIFICATIONS CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. Mounting Plate Screw Timing Gear E lectrical vac (127 vac max) 60 Hertz T hermostat O pens at 48 F (9 C) Closes at 15 F (-9 C) 165 Wire CONNECTOR PLUG CONNECTIONS Number 1 Green/Yellow 2 Yellow 3 Black 4 Lt. Blue W ire Color Connects to: Ground Water Valve Line Neutral NOTE This product comes equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds.

A - 22 23 CUBIC FOOT 26 CUBIC FOOT SERVICE PARTS STANDARD E-STAR STANDARD E-STAR Compressor Kit * 5303918303 5303918299 5303918303 5303918298 Starter/PTC/TSD * 241524604 241527802 241524604 241527801 Run Capacitor * 218909913 218909915 218909913 218909915 Temp. Control-Refr 241507701 241507701 241507701 241507701 Temp. Control-Frzr 450226-07 450226-07 450226-07 450226-07 Timer (if applicable) N/A N/A N/A N/A ADC (if applicable) 241508001 241508001 241508001 241508001 Defrost Kit 5303918253 5303918253 5303918253 5303918253 Defrost Thermostat Kit 5303918214 5303918214 5303918214 5303918214 Evaporator Fan Motor 240369701 240369701 240369701 241537301 Condenser Fan Motor 240523601 241538001 240523601 241538001 * Typical compressor kit includes compressor, electrical components, and filter-drier

SERVICE DATA SHEET INFORMATION 241532603 Test Cycling PERFORMANCE DATA NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A with Run/Start Capacitor IMPORTANT 65 F (18 C) Ambient 90 F (32 C) Ambient Variable Speed Standard Variable Speed Standard Operating Time 74 to 84% 32 to 40% 100% 55 to 65% Freezer Refrigerator Low Side Pressure (cut-in) Low Side Pressure (cut-out) High Side Pressure (last 1/3 cycle) -2 to 2 F -19 to -17 C 34 to 39 F 1 to 4 C 5 to 12 psig 43 to 83 kpa -2 to 2 psig -14 to 14kPa 90 to 105 psig 621 to 724 kpa 0 to 4 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 43 to 83 kpa -2 to 2 psig -14 to 14kPa 90 to psig 621 to 793 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C Please return this sheet to its original location. N/A -2 to 2 psig -14 to 14kPa 120 to 135 psig 827 to 931 kpa -1 to 3 F -18 to -16 C 34 to 39 F 1 to 4 C 5 to 12 psig 43 to 83 kpa -2 to 2 psig -14 to 14kPa 130 to 155 psig 896 to 1069 kpa (last 1/3 cycle) 60 to 65 120 to 150 65 to 80 130 to 160 (running).7 to 1.1 1.0 to 1.4.9 to 1.3 1.1 to 1.5 Base Voltage vac (127 vac max) vac (127 vac max) DEFROST SPECIFICATIONS Cabinet Size Thermostat Cut-in Cut-out Ohms 23 25 F (-4 C) 47 F (8 C) 450 30 Electronic Timer (ADC) Defrost 24 minutes every 6 96 hours of compressor run time. Electrical CONDENSER FAN MOTOR RPM 2.8 950 CW Opposite Shaft.1 Running SPECIFICATIONS vac (127 vac max) Thermostat Opens at 48 F (9 C) Closes at 15 F (-9 C) Voltage 85 vac CONNECTOR PLUG CONNECTIONS Wire Number Wire Color Connects to: 1 Green/Yellow Ground 2 Yellow Water Valve 3 Black Line 4 Light Blue Neutral ICE & WATER - AUTOMATIC DEFROST COUNTER DEPTH SIDE BY SIDE - R134a IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200 F and flash ignite (burn) at 500 F. Excessive heat will distort the plastic liner. NOTE This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual defrost, press and hold the Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key 5 times within 6 seconds. A d in the freezer temperature window and F in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, press and hold Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key 5 times within 6 seconds. d and F will be displayed until the defrost cycle is complete. (approx. 8 minutes) Press the momemtary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle. Water Fill Volume Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. The water fill adjustment screw will change the fill time. One turn is equal to 20cc (.68 oz.). The correct fill is 102 to Motor Gear Water Fill Adjustment Mounting Plate Screw 110cc (3.25 to 3.5 oz.). When a water valve is replaced, the fill volume must be checked TURN Mounting Plate Screws Timing Gear Ice Maker ON/OFF Switch A - 23

1 2 1 VAC 2TO5VDC 2 VARIABLE SPEED COMPRESSOR FOR E-STAR Variable Speed Compressor and E-Star only A - 24 SERVICE PARTS 23 CUBIC FOOT STANDARD 1 E-STAR 2 Compressor Kit * 5303918298 241547601 Power Board (Sigma Main) N/A 241511102 Inverter N/A 241577501 Starter/PTC 241527801 N/A Run Capacitor 218909915 N/A Sensor, 240597201 240597201 Damper Assembly 241518401 241518401 Defrost Kit 5303918253 5303918253 Defrost Thermostat Kit 5303918214 5303918214 Evaporator Fan Motor 241509401 241509401 Condenser Fan Motor 241537901 241537901 * Typical Compressor Kit includes compressor, electrical components and filter-drier.