Laboratory Automation & Robotic System Enclosures

Similar documents
BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

OUR TRUSTED SERVICE & SUPPORT

CLEAN AIR SYSTEM.

Precision Containment for All Applications

CIRCULAIRE LAMINAR AIR FLOW

Quick Reference Guide to Cabinet types

L a b o r a t o r y E q u i p m e n t C a t a l o g

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Class II ECO Generation 8 Microbiological Safety Cabinet

Gelaire BH-EN and UltraSafe cabinets

LABORATORY CABINETS 103

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

IVF/ART Series Laminar Flow Cabinets

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

B. Design meeting requirements of the particular class and type of cabinet as follows:

INCREASE YOUR LAB EFFICIENCY

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Innovation in air purification unmatched air quality

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Laminar Flow Cabinets eco air V

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Thermo Scientific 1300 Series A2

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

CIRCULAIRE FORMALIN CONTAINMENT SYSTEMS.

Biological Safety Cabinets or Fume Hoods Which one to use?

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Safe Operating Procedure (Revised 2/10)

INCREASE YOUR LAB EFFICIENCY

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Biological Safety Cabinets. Biological Safety Cabinets

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Down flow clean air cabinet Star of the Universe. Fortuna

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Biological Safety Cabinet

Florida International University. Biosafety Cabinet Program

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

AGN 088 Air Flow and Cooling

Ergonomic and Green Class II s

INCREASE YOUR LAB EFFICIENCY

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Technical Catalogue laboratory furniture system

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Environmental Health and Safety Biological Safety Program Guidance Document

Electrostatic Precipitator

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

PART III. Laboratory equipment

Technical Catalog laboratory furniture system

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

INCREASE YOUR LAB EFFICIENCY

TOPAIR CLEAN AIR SOLUTIONS CATALOG

Technical Catalogue laboratory furniture system

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Microbiological Safety Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Technical Catalog laboratory furniture system

Control of Biological Hazards

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

XPert Balance and Bulk Powder Enclosures

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

AGN 088 Air Flow and Cooling

Secuflow laboratory fume cupboards

Microbiological Safety Cabinets

OPERATION AND MAINTENANCE MANUAL

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Secuflow laboratory fume cupboards

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

Technical Catalog laboratory furniture system

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

BioSafety Cabinet- Class 100

Mars Pro. Mars Pro. Ultrasafe Class 2 An Ultrasafe Triple Filter - Microbiological Safety Cabinets. Cytosafe 3 filter Class 2 cabinets

laboratory & sterilization technology

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Clean. Easy. COMPLIANT.

Appendix A.4.1. Safe Fume Hood User Guide

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Fume Hood Safety TYPES OF FUME HOODS

Halton Rex for Vario R6O - Variable air volume chilled beam

INCREASE YOUR LAB EFFICIENCY

ZHENGZHOU FEILONG MEDICAL EQUIPMENT CO.,LTD

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets

Mars. Mars Class 2. Microbiological Safety Cabinets. ScanLaf...Advanced Designs for your Safety & Comfort. Class 2 Safety Cabinets

Ventilation for Healthcare Facilities

Ventilation for Healthcare Facilities. Topics to be Covered

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

Transcription:

LA Product Range Laboratory Automation & Robotic System Enclosures A World Class Manufacturer of Enclosures

Innovative Solutions for Advancing your Research Bigneat manufacturing a smarter range of enclosures This brochure will enable you to make a quick and easy selection of the model and size of safety enclosure for containing your laboratory automation equipment. Step 1 Knowing the protection you and/or your process requires, choose your model Step 2 Knowing the footprint of your chosen equipment, specify the size you will need Step 3 Choose your options Step 4 To request a comprehensive Speed Quote send us an email or call us detailing your needs to find out more call or email or visit Front Cover: Installation at Columbia University, USA. Picture courtesy of Tecan Schweiz AG

Safety Enclosure This non-filtration enclosure is constructed to protect operators from potentially hazardous moving mechanical laboratory equipment. model: LAEN Large optically clear acrylic windows and doors allow maximum penetration of ambient external lighting to minimise shadows. The enclosure is fitted with a laboratory grade 16mm high-pressure laminate work surface. An epoxy-coated steel stand with self-levelling/lockable castors can be provided for full mobility and a storage cupboard can be fitted as an option to this stand. Acrylic Window Normal (white) lighting is incorporated as standard. Enclosure general construction: Textured finish epoxy-coated, steel frame modules, colour - white. Clear acrylic (8mm) panels installed in UHMW tracking. Lab grade HPL 16mm composite laminate work surface. Enclosures & Sizes RE1235/01 1235 1015 1333 1115 873 1190 RE1520/01 1520 735 978 1400 593 835 RE1850/01 1850 1015 1463 1730 873 1320 Stands & Sizes PART mm NUMBER WIDTH DEPTH HEIGHT RE1235/03 or /04 1235 1015 850 RE1520/03 or /04 1520 735 850 RE1850/03 or /04 1850 1015 850 Stand materials of construction: White epoxy coated mild steel with levelling/lockable castors. Sliding Doors Services Port /03 Open Stand /04 Cupboard Stand Light Switch Included enclosure features & options (refer to back page) CF CS ES FC HP LT SP TC TS UV Stand choice SO SC option/upgrade stand required Double Socket Note: Acrylic triple sliding doors and rear panel can be removed for full access.

Enclosure for Operator Protection This enclosure is designed and constructed to provide operator protection from both contact with moving automated mechanical equipment and potentially hazardous fumes released from the enclosed processes. The gas-spring assisted steel and clear-acrylic upper access door is fitted with a neoprene gasket to ensure airtight sealing when closed and interlocked with the lower steel door. The lower door incorporates triple clear-acrylic sliding windows and enables excellent access to the interior during robot set-up and maintenance. Room air is drawn through the intake slots incorporated in the lower sliding windows. Both access doors are locked down using two 'T' handles during normal operation. The carbon and HEPA filters installed in the multiple roof-mounted fan and filter modules absorb any hazardous compounds or particulates, such as DMSO and return safe air back into the laboratory. An LCD membrane-type control panel provides audible and visual alarm indication of low airflow and door open warning. An epoxy-coated steel stand fully supports the enclosure and self-levelling/lockable castors provide full mobility. A storage cupboard can be fitted as an option to this stand. Fan & Filter Housing model: LAOP Enclosure general construction: Gloss finish epoxy-coated, steel frame modules, colour - white. Epoxy-coated steel doors, fitted with neoprene seals. Clear acrylic, 8mm panels fitted to UHMW triple tracking. Lab grade HPL, 16mm composite laminate work surface. Interlocking Gas- Spring Assisted Door Filtration: Chemcap TM carbon filters are highly efficient, absorbing a wide range of commonly used chemicals (more details available on request). Pre-filters remove particles down to 5 micron, whilst the Class H14 HEPA filters remove particulates down to 0.3 micron. Services Port LCD Control & Alarm Panel Enclosures & Sizes RO1500/01 1500 1180 2400 1420 1100 1180 RO1800/01 1800 1180 2400 1720 1100 1180 RO2200/01 2200 1180 2400 2120 1100 1180 RO2600/01 2600 1180 2400 2520 1100 1180 RO3200/01 3200 1180 2400 3120 1100 1180 Included features & options (refer to back page) Stand choice CF CS ES FC HP LT SP TC TS UV SO SC option/upgrade Cupboard Note: Acrylic side & rear panels are removable for full access.

Enclosure for Product Protection This downflow enclosure is designed and constructed to provide product protection. model: LAPP The downflow air is fully filtered by HEPA filters installed in the multiple roof-mounted fan and filter modules to provide sterile air to ISO Class 5 and Class 100 US FED Std. 209D conditions within the enclosure. The high performance airflow system ensures a minimum of 66 air changes per hour is maintained. Fan & Filter Housing The gas-spring assisted steel and clear-acrylic upper access door is fitted with a neoprene gasket to ensure airtight sealing when closed and interlocked with the lower steel door. The lower door incorporates triple clear-acrylic sliding windows and enables excellent access to the interior during robot set-up and maintenance. Both access doors are locked down using two 'T' handles during normal operation. An LCD membrane-type control panel provides audible and visual alarm indication of low airflow and door open warning. An epoxy-coated steel stand fully supports the enclosure and self-levelling/lockable castors provide full mobility. A storage cupboard can be fitted as an option to this stand. Filtration: Pre-filters remove particles down to 5 micron, whilst the Class H14 HEPA filters remove particles down to 0.3 micron. Enclosure general construction: Gloss finish epoxy-coated, steel frame modules for the enclosure and lower stand, colour - white. Epoxy coated, steel doors, fitted with neoprene seals. Clear acrylic, 8mm panels fitted to UHMW triple tracking. Lab grade, HPL 16mm composite laminate work surface. Services Port Interlocking Gas- Spring Assisted Door LCD Control & Alarm Panel Enclosures & Sizes RP1500/01 1500 1180 2400 1420 1100 1180 RP1800/01 1800 1180 2400 1720 1100 1180 RP2200/01 2200 1180 2400 2120 1100 1180 RP2600/01 2600 1180 2400 2520 1100 1180 RP3200/01 3200 1180 2400 3120 1100 1180 Included features & options (refer to back page) CF CS ES FC HP LT SP TC TS UV Stand choice SO SC option/upgrade Cupboard Note: Acrylic side & rear panels are removable for full access.

Enclosure to Provide Operator & Product Protection This bio-safety type enclosure is designed and constructed to provide operator and product protection. model: LABS The gas-spring assisted steel and clear-acrylic upper access door is fitted with a neoprene gasket to ensure airtight sealing when closed and interlocked with the lower steel door. The lower door incorporates triple clear-acrylic sliding windows and enables excellent access to the interior during robot set-up and maintenance. Both access doors are locked down using two 'T' handles during normal operation. Fan & Filter Housing The downflow air is fully filtered by HEPA filters installed in the roof-mounted fan and filter modules to provide sterile air to ISO Class 5 and Class 100 US FED Std. 209D conditions. The high performance airflow system ensures a minimum of 66 air changes per hour is maintained to give effective product protection. Operator protection is achieved by drawing inflow air (which enters through slots in the lower acrylic doors and when a sliding door is open) down through a full width grill along the front edge of the cabinet interior. All cabinet air is HEPA filtered and vented back into the room environment via the fan and filter module in the lower steel stand assembly. An LCD membrane-type control panel provides audible and visual alarm indication of low airflow and door open warning. An epoxy-coated steel stand fully supports the enclosure and self-levelling/lockable castors provide full mobility. A storage cupboard can be fitted as an option to the stand. Filtration: 1st stage Pre-filters remove particles down to 5 micron, whilst the Class H14 HEPA filters remove particles down to 0.3 micron. Enclosure general construction: Gloss finish epoxy-coated, steel frame modules for the enclosure and lower stand colour - white. Epoxy coated, steel doors, fitted with neoprene seals. Clear acrylic, 8mm panels fitted to UHMW triple tracking. Lab grade, HPL 16mm composite laminate work surface. Enclosures & Sizes RB1500/01 1500 1180 2400 1220 1000 1180 RB1800/01 1800 1180 2400 1520 1000 1180 RB2200/01 2200 1180 2400 2120 1000 1180 RB2600/01 2600 1180 2400 2320 1000 1180 RB3200/01 3200 1180 2400 2920 1000 1180 Waste Tips Box Interlocking Gas-Spring Assisted Door HEPA Filtration System LCD Control & Alarm Panel Included features & options (refer to back page) CF CS ES FC HP LT SP TC TS UV Stand choice SO SC option Notes: This enclosure is tested and validated by application of DOP testing for filter integrity and airflow measurement for containment efficiency. Acrylic side and rear panels are removable for full access.

Enclosure to Provide Operator & Product Protection Protection This Class II type bio-safety enclosure is designed and constructed to provide operator and product protection to meet the essential requirements of BS EN12469:2000. The downflow and exhaust airflow is filtered by the Class H14 HEPA filters incorporated in a common plenum to provide bio-safety Class II type levels of safety. The high performance airflow system is continuously monitored and automatically compensated by a closed-loop control system to ensure a minimum level of operator and product protection at all times. An LCD membrane-type control panel provides audible and visual alarm indication of low airflow and door open warning. Operator protection is achieved by HEPA filtering the high velocity inflow air, which enters the lower door and is drawn into a profiled grille extending the full width of the frontal area of the enclosure. Product protection is achieved by HEPA filtering downflow air, which provides a downflow velocity of between 0.25m/s and 0.5m/s. Two interlocking, gas-spring assisted fabricated-steel upper and lower access doors are fitted with neoprene seals to ensure an airtight sealing when closed. Both are locked down with T handles during operation. The enclosure includes an epoxy-coated steel stand with self-levelling/lockable castors for full mobility. Enclosure general construction: Gloss finish epoxy-coated, steel frame modules for the enclosure and lower stand, colour - white. Epoxy coated, steel doors, fitted with neoprene seals. Clear acrylic, 8mm panels fitted to UHMW triple tracking. Lab grade, HPL 16mm composite laminate work surface. Enclosure Sizes Recirculation Appropriate for biological processes but should exclude applications where radioactivity may be released. RC1500/01 1500 1400 2550 1420 1060 1180 RC1800/01 1800 1400 2550 1720 1060 1180 RC2200/01 2200 1400 2550 2120 1060 1180 RC2600/01 2600 1400 2550 2520 1060 1180 RC3200/01 3200 1400 2550 3120 1060 1180 Enclosure Sizes Ducted Appropriate for all biological applications, a proportion of the circulated air is exhausted to building ductwork via HEPA filtration system. Please replace RC with RD in part number. Dimensions are the same except the height increases to 2730mm. Included features & options (refer to back page) CF CS ES FC HP LT SP TC TS UV option Class II Type Fan & Filter Housing Waste Tips Box LCD Control & Alarm Panel model: LAC2 Interlocking Gas-Spring Assisted Door Note: This enclosure is tested and validated to the essential requirements of Class II BSC, which includes DOP testing for filter integrity and KI Discus testing for containment. The airflow system provides balanced velocities, however, some turbulence will be experienced due to the presence and repeated movement of the robotics equipment.

Speed Quote Request Email or call us for your speed quote Choose your enclosure Choose your options Please supply all part numbers Anything less than SAFE, just isn t acceptable. to find out more call or email or visit BIGNEAT LIMITED 4 & 5 Piper s Wood Industrial Park, Waterberry Drive, Waterlooville, Hampshire PO7 7XU U.K. Tel: +44 (0)23 92 266400 Fax: +44 (0)23 92 263373 Print 6/07 Feature & Option Details OPTION CODE CF CS ES FC HP LT SP TC TS UV SO SC DESCRIPTION Chemcap TM carbon filtration Arm with shelf for computer monitor and keyboard Electrical socket (double banked) supplied with fly lead for external connection. Provided with IP56 rated sockets in model LAC2 Fumigation connection. A removable coupling for connecting ventilation tubing to building ductwork for use during fumigation. Class H14 HEPA filtration (removes particles >0.3 micron) supplied with pre-filter (removes particles >5 micron) Lighting providing 480 lux Services ports Waste tips chute & box (position to be determined by customer) Tube services option for water and waste UV lighting with key switch and timer Steel stand, open Steel stand, storage cupboard Product Development: Bigneat reserves the right to make modification to designs shown. Quality Assurance: Bigneat is accredited to ISO 9001: 2000