Adequate protection of enclosed facilities

Similar documents
MONTREAL PROTOCOL ON SUBSTANCES THAT DEPLETE THE OZONE LAYER UNEP HALONS TECHNICAL OPTIONS COMMITTEE. Technical Note #1 Revision 3

BOC FS125 The Fire Extinguishing Solution

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Comparison of CFC-114 and HFC-236ea Performance in Shipboard Vapor Compression Systems

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

GX-20/FM-200 Fire Extinguishing System

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Fire suppression systems for server rooms and data centres

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

FIRE SUPPRESSION SYSTEM

Suppression Effect of Water Vapor on Flammability Limits of Hydrocarbon Fuels - A Study on Fire Suppression by Water Mist -

ON-BOARD INERT GAS GENERATING SYSTEMS: A BETTER ALTERNATIVE Justin Bright Advisor: Margaret Browning Hampton University. Abstract

How can I protect invaluable assets and the environment from the effects of a fire?

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

This is a repository copy of Fluorinated halon replacement agents in explosion inerting.

CLEAN AGENTS & CLASS C FIRE HAZARDS

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

ASSEMBLY 37TH SESSION

This is a repository copy of Clean Agents in Explosion Inerting. White Rose Research Online URL for this paper:

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

The Problem of Counterfeit Refrigerants

Essentials of Fire Fighting 6 th Edition Firefighter I

Nan-Volatile Precursor (NVP) agents have been prepared which

An Overview of Extinguishing Systems for Computer Equipment

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

SHIPBOARD TOTAL FLOODING FIRE PROTECTION SYSTEMS FOR HALON 1301 REPLACEMENT

WATER MIST CONVENTION AND EXHIBITION

KD Innovative extinguishing with Novec TM 1230 by 3M TM

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

The Science Behind Water Mist Protection of Typical Building Hazards

REFRIGERATION CHAPTER 11

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS


Effectively Managing the Transition to Lower GWP Refrigerants

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

Fire fighting Portable fire extinguishers Performance and construction

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

How can you minimize consequential damages in case of a fire?

Certificate of Compliance

Flammability and New Refrigerant Options

Hazardous Material Safety Program

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

COMMISSION REGULATION (EU)

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

REFRIGERATION CHAPTER 11

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

SEMICONDUCTOR FABRICATION FACILITIES

Ozone Depleting Substances (ODS) Rule Updates

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

REFRIGERATION CHAPTER 11

Specifications for Fluorocarbon Refrigerants

ODS & SGG Alternatives for the Fire Protection Industry 2018

Specifications for Fluorocarbon Refrigerants

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

& Fire Extinguisher Training

tyco Fire & Safety RESEARCH VESSEL - NEW ORLEANS

Certificate of Compliance. 1.2 ITEM NUMBER AND SIZES: ml, ml, ml, ml

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

REFRIGERANT PROCEDURE

Fire is No Accident Fire is No Accident It can be prevented.

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

A2L Refrigerants. Objectives 14/09/2017

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

3M Novec Fire Protection Fluid

HFID Heated Total Hydrocarbon Analyzer Module

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Superior by Design The Kidde ADS TM FM-200 System

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Low GWP Refrigerants for Air Conditioning Applications

An experimental study of the impact of tunnel suppression on tunnel ventilation

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Scroll Chillers Transition from HCFC-22 to HFCs

CO2 COCO GAS FLOODING SYSTEM

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

Fire Extinguishing Agents for Protection of Occupied Spaces in Military Ground Vehicles

QENOS ALTONA SAFETY CASE COMMUNITY INFORMATION BULLETIN 2012

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Available online at ScienceDirect. Synthesis and fire-extinguishing properties of monobromotrifluoropropene

Natural refrigerants - naturally efficient

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

NASA. Technical Support Package. Perfluorocarbons as Fire-Supression Agents. National Aeronautics and Space Administ rat ion

Portable Fire Extinguishers

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Safe, Effective, Environment-friendly

Unit 6: Fire Investigation

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

ISO INTERNATIONAL STANDARD. Hydrogen generators using fuel processing technologies Part 1: Safety

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Transcription:

United States National Risk Management Environmental Protection Research Laboratory Agency Research Triangle Park NC 27711 Research and Development EPA/600/SR-95/150b December 1995 Project Summary Low Ozone-Depleting Halocarbons As Total-Flood Agents: Volume 2 Laboratory- Scale Fire Suppression and Explosion Prevention Testing Stephanie R. Skaggs, Everett W. Heinonen, Ted A Moore, and Jon A. Kirst Adequate protection of enclosed facilities against explosions and fires involving flammable gases or streaming liquid fuels poses a major safety challenge for the Alaskan North Slope petroleum industry. At present, such facilities are protected by Halon 1301 total-flood systems. However, because of its depletion of stratospheric ozone, the production of Halon 1301 was halted under international treaty on December 31, 1993. The report gives results from flame suppression testing of potential Halon 1301 replacement chemicals in a cup burner using n-heptane fuel and inertion testing in a smallscale explosion sphere, with propane and methane as test fuels. Test equipment and techniques are described. Fire suppression test results are given for a wide range of halocarbon chemicals. For inertion testing, differences between Halon 1301 inerting concentrations, determined using the current test apparatus and previous testing, are briefly discussed. Agent performance is given in terms of the concentration required to achieve flame extinguishment or inertion, defined as an explosive overpressure of 1 psi (6.9 kpa) or less, and weight and storage volume equivalents, reflecting the weight and storage volume of a replacement agent required to achieve the same effectiveness performance as Halon 1301. This Project Summary was developed by EPA s National Risk Assessment Research Laboratory, Research Triangle Park, NC, to announce key findings of the research project that is fully documented in a separate report of the same title (see Project Report ordering information at back). Introduction Enclosed spaces containing flammable hydrocarbon fuels present challenging fire and explosion protection problems. Of particular concern are Alaskan North Slope petroleum handling facilities, where leaks of flammable gaseous and liquid hydrocarbons can occur, presenting both fire and explosion hazards. At present, the primary fire and explosion protection measure for such facilities is total-flood application of Halon 1301. However, due to depletion of stratospheric ozone, the production of halon fire extinguishing agents (including Halon 1301) was banned as a result of an international treaty, the Montreal Protocol. The report describes the laboratory-scale experimental evaluation of a number of halocarbon candidates as Halon 1301 replacements for total-flood application in enclosed facilities such as those found at the Alaskan North Slope. Two types of halocarbon chemicals were emphasized in this effort: (1) physical action agents (PAAs), which extinguish flames by physical means such as heat absorption, evaporative cooling, thermal dissociation, and separation and dilution of fuel and oxygen, and (2) chemical action agents (CAAs), which cause fire suppression primarily by free radicals catalytically interrupting the combustion chain reaction mechanism. CAAs generally are more effective at suppressing fires and explosions than PAAs. The designa-

tion of chemicals into these categories does not imply that agents operate exclusively by one mechanism or the other, rather that one action appears to be the predominant mode of extinguishment. A list of PAAs and CAAs was developed in a previous effort. Candidates were separated into categories based on availability and toxicity information. Those chemicals that are available in bulk now or apt to be in the near future and which have a significant amount of toxicological information known indicating that they are low in toxicity are given highest priority for testing. The results of testing these chemicals are presented here. Fire Suppression Testing Fire suppression effectiveness of 71 halocarbon chemicals was determined in the laboratory cup-burner apparatus using n-heptane as the fuel. A reduced-scale version of the widely known Hirst and Booth cup burner was used. Extinguishment values are calculated from molar flow rates for gases or volumetric flow rates for liquids and reported as volume percent concentration. The weight and storage volume equivalents are calculated relative to Halon 1301 in order to compare fire suppression performance to the reference agent. Results of the cup burner testing are presented in Table 1. Explosion Prevention Testing Explosion prevention or inertion testing was performed on 34 chemicals in an explosion sphere modeled after the Fenwal Safety Systems explosive sphere. The apparatus consisted of two 25-cm diameter stainless steel hemispheres hinged together to contain a volume of 7930 cm 3. A stoichiometric mixture of fuel (propane or methane), air, and inerting chemicals was introduced into the sphere using the partial pressure method. The mixture was ignited by a variable-power direct-current (dc) spark generated between two electrodes in the center of the sphere. The resulting overpressure was measured. The volume percent concentration at which the overpressure did not rise above 1 psi (6.9 kpa) was considered the inertion concentration for stoichiometric fuel and air mixtures (IC st ). Weight and storage volume equivalents were calculated using Halon 1301 as the reference chemical. The results of the inertion testing are presented in Table 2. Limited testing to determine the flammability diagrams or envelopes indicates that higher concentrations may be required to inert non-stoichiometric fuel and air mixtures. Therefore, testing at other than stoichiometric fuel-to-air ratios should be undertaken before setting design specifications for a particular agent. Conclusions Results obtained from this study represent laboratory-scale testing within controlled parameters. Methods employed in this effort proved to be reliable and repeatable for agent screening and ranking a number of halocarbons. However, care must be taken not to extrapolate these results to larger scale without verification. Results of the fire suppression and explosion prevention testing clearly demonstrated that those agents containing either bromine or iodine exhibited superior effectiveness. However, several considerations must be taken into account when recommending which chemicals should be investigated further as candidates for replacing Halon 1301. Since this effort emphasized protection of North Slope oil and gas facilities, the nature of the threat unique to these applications was of key importance. For the most part, the North Slope facilities are generally accessible to humans, although some areas are occupied only intermittently or infrequently. Because human occupancy is a major concern, the toxicity of the candidates must be sufficiently low to allow for human exposure at safe levels. With the production phaseout of new Halon 1301 at the end of 1993, the North Slope facilities will need to continue their fire and explosion protection measures using either Halon 1301 or other chemicals or technologies. To the extent that insufficient supplies of recycled Halon 1301 are available for North Slope use in the near-term, replacement agents will be needed. The need for a near-term replacement limits the number of chemicals that can be considered as candidates to only those which are available now or will be available in the near future. Also, a significant amount of toxicity information must be known about a chemical to allow its use in occupied areas. Additionally, a number of federal and state regulatory approvals must be obtained before new agents can be used. At the time of this project, the National Fire Protection Association (NFPA) had selected a number of Halon-1301 replacement candidates with potential for use in the near-term. Those candidates selected by the NFPA are shown in Table 3. All of these chemicals, including HCFC Blend A, were evaluated at laboratory scale by this study. The extinguishment and inertion concentrations for HCFC Blend A were found to be no different than for the major component, HCFC-22, and therefore results of this blend are not reported separately in Tables 1 and 2. The candidates in Table 3 did not exhibit the best performance for fire suppression or explosion prevention effectiveness in this laboratory evaluation. However, these agents are or will soon be available in bulk, and a significant amount of toxicity information exists that allows a determination of their safety. NFPA has established guidelines to specify agents that can be used in occupied areas. These guidelines specify that the fire suppression or inertion design concentration of agents must be below the cardiac sensitization No Observable Adverse Effect Level (NOAEL) of the agents. NOAEL levels for the Table 3 agents are listed in Table 4 along with the design concentrations for inertion and fire suppression as determined by this work. These minimum design concentrations represent the measured suppression or inertion concentration plus an additional 10% safety factor for inertion and 20% for fire suppression. From the values in Table 4, only FC-3-1-10 and HFC-23 would be acceptable based on NFPA standards for use in occupied areas designed for protection against propane explosions and fires. HFC- 227ea would also be acceptable for use in occupied areas for fire protection only. Of the other agents that are not commercially available in the near-term, CAAs offer the greatest potential for replacing Halon 1301 with equal or better performance. Of the CAAs, the fluoroiodocarbons, in particular the iodinated analog of Halon 1301 (FIC-1311), appear to be the most promising from an effectiveness perspective. 2

Table 1. Candidate Fire Suppression Effectiveness Ordered by Storage Volume Equivalents MW Liq. Dens. Exting. conc. Halocarbon No. (g/mole) (g/ml) (vol %) GVEq* WEq SVEq BFC-21B2 191.81 2.42 1.8 0.62 0.80 0.50 HBFC-123B2 241.81 2.22 1.9 0.66 1.06 0.72 HBFC-123aB2 241.81 2.17 2.0 0.69 1.12 0.78 FIC-13I1 195.91 2.36 3.0 1.03 1.36 0.87 FIC-115-I1 245.91 2.07 2.1 0.72 1.20 0.87 HBFC-124B1 180.92 1.85 2.9 1.00 1.22 0.99 Halon 1301 148.91 1.50 2.9 1.00 1.00 1.00 HBFC-22B1 130.90 1.55 4.4 1.52 1.33 1.29 FIC-217caI1 295.92 2.06 3.0 1.03 2.06 1.50 FIC-217baI1 295.92 2.10 3.2 1.10 2.19 1.57 HFC-32 52.02 0.98 8.8 3.03 1.06 1.62 FIC-319aI1 345.92 2.01 2.8 0.97 2.24 1.67 BTFB 206.96 1.36 3.5 1.21 1.68 1.85 FIC-5-1-13aI1 445.94 2.05 2.5 0.86 2.58 1.89 HFC-236fa 152.04 1.37 5.6 1.93 1.97 2.16 BCTFB # 233.40 1.68 4.5 1.55 2.43 2.16 HCFC-133a 118.50 1.39 7.6 2.62 2.09 2.25 FC-116 138.01 1.59 7.8 2.69 2.49 2.35 HFC-236ea 152.04 1.42 6.6 2.28 2.32 2.45 HFC-227ea 170.03 1.42 6.3 2.17 2.48 2.62 FC-3-1-10 238.03 1.52 5.0 1.72 2.76 2.72 HFC-227ca 170.03 1.39 6.5 2.24 2.56 2.76 HCFC-124 136.48 1.38 8.2 2.83 2.59 2.82 FC-218 188.02 1.35 6.1 2.10 2.66 2.95 HCFC-22 86.47 1.17 11.6 4.00 2.32 2.98 FC-5-1-14 338.03 1.68 4.4 1.52 3.44 3.08 HFC-134a 102.03 1.20 10.5 3.62 2.48 3.10 FC-6-1-16 388.03 1.73 4.0 1.38 3.59 3.12 FC-14 88.00 1.33 13.8 4.76 2.81 3.17 HFC-245cb 134.05 1.20 8.2 2.83 2.55 3.18 HFC-125 120.02 1.23 9.4 3.24 2.61 3.19 HFC-134 102.03 1.20 11.2 3.86 2.65 3.31 FC-C-318 200.04 1.48 7.2 2.48 3.34 3.38 HFC-23 70.01 0.67 12.6 4.34 2.04 4.57 * GVEq=Gas Volume Equivalent WEq=Weight and Equivalent SVEq=Storage Volume Equivalent 4-Bromo-3,3,4,4-tetrafluoro-1-butene # 4-Bromo-3-chloro-3,4,4-trifluoro-1-butene 3

Table 2. Explosion Prevention Performance Ordered by Storage Volume Equivalent, Propane As Fuel MW LD* ICst Chemical (g/mole) (g/ml) (vol %) GVEq WEq SVEq # Halon 1301 148.91 1.50(30) 4.3 1.00 1.00 1.00 FIC-13I1 195.91 2.36(-42) 5.2 1.21 1.59 1.01 HBFC-124B1 180.92 1.85** 5.8 1.35 1.64 1.33 HFC-152a 66.05 0.91 10.1 2.35 1.04 1.72 HBFC-22B1 130.92 1.55 8.8 2.05 1.80 1.74 BTFB 206.98 1.357 5.3 1.23 1.71 1.89 FIC-319I1 345.92 2.01(20) 4.9±0.6 1.14 2.65 1.98 HFC-32 52.02 0.98 17.8 4.14 1.45 2.21 HFCs-32/125 ## 67.3 1.07(21) 16.3 3.79 1.71 2.40 FIC-217cal1 295.92 2.06(20) 7.6±0.4 1.77 3.51 2.56 HFC-254cb 116.01 1.0** 9.7 2.26 1.76 2.64** HFC-236fa 152.04 1.37*** 10.5 2.44 2.49 2.73** HFC-245cb 134.05 1.20** 10.7 2.49 2.24 2.80** HFC-134a 102.03 1.20 14.1 3.28 2.25 2.81 HFC-134 102.03 1.20** 14.5 3.37 2.31 2.89 HCFC-124 136.48 1.38 12.6 2.93 2.69 2.92 HFC-236ea 152.04 1.42** 11.7 2.72 2.78 2.93** CO 2 44.0 1.03(-20) 29.7 6.91 2.04 2.97 FIC-115I1 245.91 2.07(28) 11.0 2.56 4.22 3.06 N 2 28.01 0.8 38.0 8.84 1.66 3.12 FC-4-1-12 288.03 1.63 7.6 1.77 3.42 3.15 FC-116 138.01 1.59(-73) 15.9 3.70 3.43 3.23 FC-14 88.01 1.33(-80) 21.1 4.91 2.90 3.27 HFC-227ea 170.03 1.42 11.9 2.77 3.16 3.34 HCFC-22 86.47 1.17 19.4 4.51 2.62 3.36 HFC-125 120.02 1.23(20)** 14.7 3.42 2.76 3.36 FC-5-1-14 338.03 1.68 7.2** 1.67** 3.80** 3.39** FC-6-1-16 388.03 1.73 6.5 1.51 3.94 3.42 FC-3-1-10 238.03 1.52 9.6 2.23 3.57 3.52 FC-218 118.02 1.35 11.2 2.60 3.29 3.65 HFC-227ca 170.03 1.39** 12.9 3.00 3.43 3.70 FC-C-318 200.04 1.48(11) 11.7 2.72 3.66 3.70 HCFC-142b 100.5 1.12 19.5 4.53 3.06 4.10 HFC-23 70.01 0.67 19.5 4.53 2.13 4.77 * Liquid density (LD) at 25 C unless noted in parentheses ICst = Stoichiometric inerting concentration GVEq.= Gas Volume Equivalent WEq = Weight Equivalent # SVEq = Storage Volume Equivalent ** Estimate Flammable compound 4-Bromo-3,3,4,4-tetrafluoro-1-butene Number of tests limited due to small sample amounts. IC is midpoint of concentrations resulting in an explosion (-value) and no explosion (+ value) ## 60% HFC-32/40% HFC-125 *** Measured. 4

Table 3. NFPA Near-Term Halon 1301 (Halocarbon) Replacement Candidates* Number designation Chemical name Chemical formula FC-3-1-10 Perfluorobutane C 4 F 10 HBFC-22B1 Bromodifluoromethane CHF 2 Br HCFC-124 Chlorotetrafluoroethane CHClFCF 3 HCFC Blend A Dichlorotrifluoroethane (HCFC-123), 4.75% CHCl 2 CF 3 Chlorodifluoromethane (HCFC-22), 82% CHClF 2 Chlorotetrafluoroethane (HCFC-124), 9.5% CHClFCF 3 4-Isopropenyl-1-methyl-1-cyclohexene (d-limonene), 3.75% C 6 H 10 HFC-23 Trifluoromethane CHF 3 HFC-125 Pentafluoroethane CHF 2 CF 3 HFC-227ea Heptafluoropropane CF 3 CHFCF 3 * NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems, National Fire Protection Association, 1994 Edition. Table 4. Cardiotoxicity Values and Inertion Design Concentrations for NFPA Near-Term Agents* Design concentration Number Inertion, Propane Fire Suppression NOAEL LOAEL Designation (vol %) (vol %) (vol %) (vol %) FC-3-1-10 10.6 6.0 40 >40 HBFC-22B1 9.7 5.3 2 3.9 HCFC-124 13.9 9.8 2.5 1.0 HCFC Blend A 19.8 7.2 (13.4) # 10 >10 HFC-23 21.5 15.1 50 >50 HFC-125 16.2 11.3 7.5 10 HFC-227ea 13.1 7.6 9.0 10.5 * NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems, National Fire Protection Association, 1994 Edition. Minimum design concentration is determined by the laboratory test plus 10% safety factor for inertion and 20% safety factor for fire suppression. Values from this work. NOAEL = Highest tested concentration at which no adverse cardiac effects were observed. Adverse cardiac effects generally refer to multiple irregular heart beats, arrhythmia, or death. LOAEL = Lowest tested concentration at which adverse cardiac effects were observed. # Manufacturer s design concentration determined by UL Canada as provided in NFPA 2001. Design concentration based on this work given in parentheses. 5

Stephanie R. Skaggs, Everett W. Heinonen, Ted A Moore, and Jon A. Kirst are with the University of New Mexico, Albuquerque, NM 87131-1376. N. Dean Smith is the EPA Project Officer (see below). The complete report, entitled Low Ozone-Depleting Halocarbons As Total-Flood Agents: Volume 2 Laboratory-Scale Fire Suppression and Explosion Prevention Testing, (Order No. PB96-109079; Cost: $27.00, subject to change) will be available only from National Technical Information Service 5285 Port Royal Road Springfield, VA 22161 Telephone: 703-487-4650 The EPA Project Officer can be contacted at National Risk Management Research Laboratory U.S. Environmental Protection Agency Research Triangle Park, NC 27711 United States Environmental Protection Agency National Risk Management Research Laboratory (G-72) Cincinnati, OH 45268 BULK RATE POSTAGE & FEES PAID EPA PERMIT No. G-35 Official Business Penalty for Private Use $300 EPA/600/SR-95/150b 6